Search NASA⌕ Search

SEARCH · Search NASA

Results for “Renewable Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Energy Systems Integration Partnerships: NREL + GINER ELX

At current levels of renewable generation there are already periods when the supply of electrical power significantly exceeds the level of demand. The wide penetration of renewable energy sources (RES) requires an energy storage solution which can include hydrogen generated via Polymer Electrolyte Membrane (PEM) electrolysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE: Integrating Southwest Power Pool Wind Energy into Southeast Electricity Markets

Wind power development in the United States is outpacing previous estimates for many regions, particularly those with good wind resources. The pace of wind power deployment may soon outstrip regional capabilities to provide transmission and integration services to achieve the most economic power system operation. Conversely, regions such as the Southeastern United States do not have good wind resources and will have difficulty meeting proposed federal Renewable Portfolio Standards with local supply. There is a growing need to explore innovative solutions for collaborating between regions to achieve the least cost solution for meeting such a renewable energy mandate. The DOE-funded project 'Integrating Southwest Power Pool Wind Energy into Southeast Electricity Markets' aims to evaluate the benefits of coordination of scheduling and balancing for Southwest Power Pool (SPP) wind transfers to Southeastern Electric Reliability Council (SERC) Balancing Authorities (BAs). The primary objective of this project is to analyze the benefits of different balancing approaches with increasing levels of inter-regional cooperation. Scenarios were defined, modeled and investigated to address production variability and uncertainty and the associated balancing of large quantities of wind power in SPP and delivery to energy markets in the southern regions of the SERC. The primary analysis of the project is based on unit commitment (UC) and economic dispatch (ED) simulations of the SPP-SERC regions as modeled for the year 2022. The UC/ED models utilized for the project were developed through extensive consultation with the project utility partners, to ensure the various regions and operational practices are represented as accurately as possible realizing that all such future scenario models are quite uncertain. SPP, Entergy, Oglethorpe Power Company (OPC), Southern Company, and the Tennessee Valley Authority (TVA) actively participated in the project providing input data for the models and review of simulation results and conclusions. While other SERC utility systems are modeled, the listed SERC utilities were explicitly included as active participants in the project due to the size of their load and relative proximity to SPP for importing wind energy. The analysis aspects of the project comprised 4 primary tasks: (1) Development of SCUC/SCED model of the SPP-SERC footprint for the year 2022 with only 7 GW of installed wind capacity in SPP for internal SPP consumption with no intended wind exports to SERC. This model is referred to as the 'Non-RES' model as it does not reflect the need for the SPP or SERC BAs to meet a federal Renewable Energy Standard (RES). (2) Analysis of hourly-resolution simulation results of the Non-RES model for the year 2022 to provide project stakeholders with confidence in the model and analytical framework for a scenario that is similar to the existing system and more easily evaluated than the high-wind transfer scenarios that are analyzed subsequently. (3) Development of SCUC/SCED model of the SPP-SERC footprint for the year 2022 with sufficient installed wind capacity in SPP (approximately 48 GW) for both SPP and the participating SERC BAs to meet an RES of 20% energy. This model is referred to as the 'High-Wind Transfer' model with several different scenarios represented. The development of the High-Wind Transfer model not only included identification and allocation of SPP wind to individual SERC BAs, but also included the evaluation of various methods to allow the model to export the SPP wind to SERC without developing an actual transmission plan to support the transfers. (4) Analysis of hourly-resolution simulation results of several different High-Wind Transfer model scenarios for the year 2022 to determine balancing costs and potential benefits of collaboration among SPP and SERC BAs to provide the required balancing.

17 WIND ENERGY↗

Alternative Fuels Data Center and Related Technology Integration Tools

The U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy's Vehicle Technologies Office (VTO) facilitates national coordination of the Clean Cities coalitions through its Technology Integration Program. VTO's Technology Integration Program supports a broad technology portfolio that can reduce transportation energy costs for businesses and consumers. Fleets, cities, and regions can use the tools featured in this guide to implement alternative fuels and advanced vehicles. Also learn how Clean Cities coalitions and their stakeholders across the country have used the tools.

AFDC↗

Alternative Fuels Data Center and Related Technology Integration Tools

The U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy's Vehicle Technologies Office (VTO) facilitates national coordination of the Clean Cities coalitions through its Technology Integration Program. VTO's Technology Integration Program supports a broad technology portfolio that can reduce transportation energy costs for businesses and consumers. Fleets, cities, and regions can use the tools featured in this guide to implement alternative fuels and advanced vehicles. Also learn how Clean Cities coalitions and their stakeholders across the country have used the tools.

47 OTHER INSTRUMENTATION↗

Techno-Economic Analysis of Compressed Air Energy Storage and Hydrogen Production from Variable Renewable Energy

This study presents the techno-economic analysis (TEA) results of integrating electrolysis hydrogen (H 2 ) production, compressed air energy storage (CAES), and H 2 -fired combustion turbines in a high variable renewable energy (VRE) market environment. The inconsistent nature of VRE creates challenges for power producers in maintaining a stable electrical grid as it is increasingly utilized. The mission of the National Energy Technology Laboratory (NETL) is driving innovation and delivering energy solutions, and a multiangle approach involving H 2 production, energy storage, and next-level H 2 -fired combustion turbine generator (CTG) technologies could provide one solution for the nation’s growing electrical grid issues with increasing VRE sources. The H 2 production and CAES concept were investigated due to its ability to provide utility-scale H 2 -fueled power generation with large-scale energy storage capabilities. Two facilities with CAES and natural gas-fired CTGs (in McIntosh, Alabama, and Huntorf, Germany) have been operating for decades. In contrast, this study investigates the potential to replace the natural gas fuel with H 2 fuel. This concept has been publicly presented by both Siemens Energy and Bechtel Global Engineering, Construction & Project Management (Bechtel) at two different power generating levels. The CAES and air expansion/combustion turbine power generation in this study are primarily based on the Siemens Energy system (Bailie, Aug. 10-11, 2021) (Scheller, Feb. 21, 2023). The inclusion of a H 2 turboexpander generator is from Bechtel (Gülen, Sep. 6, 2022). A block flow diagram of the proposed process is illustrated in Exhibit ES-1.

08 HYDROGEN↗

Use of the Tool to Support Renewable Energy Auctions Processes (RE Data Explorer)

Renewable energy auctions are now a common competitive approach to procure low-cost renewable power around the world. Ensuring a successful auction process increasingly depends on the capabilities of auction designers and participants to identify actionable and defensible insights from large data sets (on renewable energy resources and complementary data) to both attract potential investors and address stakeholder concerns. The Renewable Energy (RE) Data Explorer is a user-friendly geospatial analysis tool for analyzing renewable energy potential and informing decisions. Developed by the National Renewable Energy Laboratory (NREL) and supported by the U.S. Agency for International Development (USAID), RE Data Explorer performs visualization and analysis of renewable energy potential that can be customized for different scenarios. RE Data Explorer can support prospecting, integrated planning, policymaking, and other decision-making activities to accelerate renewable energy deployment. The broader RE Explorer website provides guidance and information to link the RE Data Explorer geospatial analysis tool to key decision areas. This document provides information on how the RE Data Explorer can be used to support renewable energy auction processes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Use of the Tool to Support Renewable Energy Project Development (RE Data Explorer)

The Renewable Energy (RE) Data Explorer is a user-friendly, geospatial analysis tool for analyzing renewable energy potential and informing decisions. Developed by the National Renewable Energy Laboratory (NREL) and supported by the U.S. Agency for International Development (USAID), RE Data Explorer performs visualization and analysis of renewable energy potential that can be customized for different scenarios. RE Data Explorer can support prospecting, integrated planning, policymaking, and other decision-making activities to accelerate renewable energy deployment. This document provides information on how the RE Data Explorer can support private sector utility-scale renewable energy project development.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Renewable energy storage via efficient reversible hydrogenation of piperidine captured CO 2

The storage of renewable energy is the major hurdle during the transition of fossil resources to renewables. A possible solution is to convert renewable electricity to chemical energy carriers such as hydrogen for storage. In this paper, a highly efficient formate-piperidine-adduct (FPA) based hydrogen storage system was developed. This system has shown rapid reaction kinetics of both hydrogenation of piperidine-captured CO 2 and dehydrogenation of the FPA over a carbon-supported palladium nano-catalyst under mild operating conditions. Moreover, the FPA solution based hydrogen storage system is advantageous owing to the generation of high-purity hydrogen, which is free of carbon monoxide and ammonia. In situ ATR-FTIR characterization was performed in order to provide insight into the reaction mechanisms involved. Finally, by integrating this breakthrough hydrogen storage system with renewable hydrogen and polymer electrolyte membrane fuel cells (PEMFC), in-demand cost-effective rechargeable hydrogen batteries could be realized for renewable energy storage.

25 ENERGY STORAGE↗

Hydrogen Generation and Industrial Heat Opportunities for Nuclear Plants in the Gulf Coast

The United States (U.S.) nuclear-generation fleet stands as a critical national strategic asset, playing a pivotal role in achieving climate goals. Operating on light-water reactor (LWR) technologies, this fleet provides the largest share of U.S. carbon-free electrical generation, ensuring 24/7 clean-energy stability. With a proven track record of reliability while operating at high-capacity factors, consistently above 90%, the existing nuclear fleet serves as a cornerstone for sustainable energy. The Department of Energy’s (DOE’s) Light Water Reactor Sustainability (LWRS), Flexible Plant Operations and Generation pathway addresses U.S. nuclear power plant (NPP) grid integration challenges in the face of evolving energy landscapes. Research at Idaho National Laboratory (INL) highlights the potential synergy between high-temperature steam-electrolysis (HTSE) technology and nuclear steam and electricity during periods of high renewable grid penetration. Large-scale nuclear-integrated hydrogen production through HTSE presents significant potential for decarbonizing such energy-intensive sectors as oil refining, petrochemicals, ammonia, and fertilizers. The strategic advantage lies in the nuclear sector’s capability to deliver clean electrical and/or steam output during periods of low demand. Nuclear-produced hydrogen—with its ability to provide high-purity clean H 2 well below the national standard of 1 kg of CO 2 per kg of H 2 —represents a breakthrough methodology. This emphasizes the crucial role NPPs can fill in addressing the increasing need for clean hydrogen, establishing them as essential contributors to decarbonization. This report specifically delves into hydrogen-generation opportunities from the U.S. Gulf Coast region. This study aims to assess NPP capabilities for hydrogen production and to identify practical nearby industrial and pipeline-operator off-takers for nuclear-integrated hydrogen production as well as to present some specific case-study analysis showing the conditions under which nuclear hydrogen production and sale can be profitable. Also considered in this report is preliminary analysis of nuclear-heat opportunities accessible near Waterford NPP via transportation of hypothetical steam pipelines and heat-exchange equipment.

08 HYDROGEN↗

Refinery Integration Analysis: Pathways, Challenges, and Opportunities

Integrating biomass-derived intermediates into traditional petroleum refineries presents unique challenges and opportunities, requiring innovative analysis approaches that account for biofuel producers and refiners. Consequently, teams within the National Renewable Energy Laboratory (NREL) have developed a comprehensive refinery integration analysis framework that combines experimental data, detailed techno-economic analyses of bio-conversion pathways, and economic projections within refinery linear programming (LP) optimization models. These models enable the identification of promising bio-integration strategies tailored to specific refinery configurations, economic conditions, and production goals. They also capture upstream and downstream impacts, highlighting critical bottlenecks and research opportunities for increasing the share of biogenic feedstocks in traditional refining operations. Refinery models are also packaged into a broader bio-economy optimization framework which enables biofuel supply chain optimization with standalone biofuel production and refinery co-processing/repurposing options. This presentation discusses promising refinery bio-integration strategies along with key challenges and opportunities identified using NREL's refinery and bio-economy optimization frameworks.

09 BIOMASS FUELS↗

Solar Reforming of Carbon Dioxide to Produce Diesel Fuel

This project focused on the demonstration of an innovative technology, referred to as the Sunexus CO2 Solar Reformer, which utilizes waste CO2 as a feedstock for the efficient and economical production of synthetic diesel fuel using solar thermal energy as the primary energy input. The Sunexus technology employs a two stage process for the conversion of CO2 to diesel fuel. A solar reforming system, including a specially designed reactor and proprietary CO2 reforming catalyst, was developed and used to convert captured CO2 rich gas streams into syngas (primarily hydrogen and carbon monoxide) using concentrated solar energy at high conversion efficiencies. The second stage of the system (which has been demonstrated under other funding) involves the direct conversion of the syngas into synthetic diesel fuel using a proprietary catalyst (Terra) previously developed and validated by Pacific Renewable Fuels and Chemicals (PRFC). The overall system energy efficiency for conversion of CO2 to diesel fuel is 74%, due to the use of solar energy. The results herein describe modeling, design, construction, and testing of the Sunexus CO2 Solar Reformer. Extensive parametric testing of the solar reformer and candidate catalysts was conducted and chemical kinetic models were developed. Laboratory testing of the Solar Reformer was successfully completed using various gas mixtures, temperatures, and gas flow rates/space velocities to establish performance metrics which can be employed for the design of commercial plants. A variety of laboratory tests were conducted including dry reforming (CO2 and CH{sub 4}), combination dry/steam reforming (CO2, CH{sub 4} & H{sub 2}O), and tri-reforming (CO2, CH{sub 4}, H{sub 2}O & O{sub 2}). CH{sub 4} and CO2 conversions averaged 95-100% and 50-90% per reformer cycle, respectively, depending upon the temperatures and gas space velocities. No formation of carbon deposits (coking) on the catalyst was observed in any of these tests. A 16 ft. diameter, concentrating solar dish was modified to accommodate the Sunexus CO2 Solar Reformer and the integrated system was installed at the Pacific Renewable Fuels and Chemicals test site at McClellan, CA. Several test runs were conducted without catalyst during which the ceramic heat exchanger in the Sunexus Solar Reformer reached temperatures between 1,050 F (566 C) and 2,200 F (1,204 C) during the test period. A dry reforming mixture of CO2/CH{sub 4} (2.0/1.0 molar ratio) was chosen for all of the tests on the integrated solar dish/catalytic reformer during December 2010. Initial tests were carried out to determine heat transfer from the collimated solar beam to the catalytic reactor. The catalyst was operated successfully at a steady-state temperature of 1,125 F (607 C), which was sufficient to convert 35% of the 2/1 CO2/CH{sub 4} mixture to syngas. This conversion efficiency confirmed the results from laboratory testing of this catalyst which provided comparable syngas production efficiencies (40% at 1,200 F [650 C]) with a resulting syngas composition of 20% CO, 16% H{sub 2}, 39% CO2 and 25% CH{sub 4}. As based upon the laboratory results, it is predicted that 90% of the CO2 will be converted to syngas in the solar reformer at 1,440 F (782 C) resulting in a syngas composition of 50% CO: 43% H{sub 2}: 7% CO2: 0% CH{sub 4}. Laboratory tests show that the higher catalyst operating temperature of 1,440 F (782 C) for efficient conversion of CO2 can certainly be achieved by optimizing solar reactor heat transfer, which would result in the projected 90% CO2-to-syngas conversion efficiencies. Further testing will be carried out during 2011, through other funding support, to further optimize the solar dish CO2 reformer. Additional studies carried out in support of this project and described in this report include: (1) An Assessment of Potential Contaminants in Captured CO2 from Various Industrial Processes and Their Possible Effect on Sunexus CO2 Reforming Catalysts; (2) Recommended Measurement Methods for Assessing Contaminant Levels in Captured CO2 Streams; (3) An Assessment of Current Commercial Scale Fisher-Tropsch (F-T) Technologies for the Conversion of Syngas to Fuels; (4) An Overview of CO2 Capture Technologies from Various Industrial Sources; and (5) Lifecycle Analysis for the Capture and Conversion of CO2 to Synthetic Diesel Fuel. Commercial scale Sunexus CO2 Solar Reformer plant designs, proposed in this report, should be able to utilize waste CO2 from a wide variety of industrial sources to produce a directly usable synthetic diesel fuel that replaces petroleum derived fuel, thus improving the United States energy security while also sequestering CO2. Our material balance model shows that every 5.0 lbs of CO2 is transformed using solar energy into 6.26 lbs (1.0 U.S. gallon) of diesel fuel and into by-products, which includes water. Details are provided in the mass and energy model in this report.

03 NATURAL GAS↗

On Evaluating Cycling and Movement of Conventional Generators for Balancing Services with Large Solar Penetration

Abstract— The increasing uncertainty caused by a higher penetration level of renewable energy points to the need for sufficient balancing services to ensure secure operation. It is thus of necessity to accurately quantify these services and evaluate the cycling and movement of conventional generators providing load following and regulation services for optimally planning and scheduling multiple resources. This paper first introduces a systematic approach to calculating load following and regulation requirements with a large amount of solar integration. Then, two methods to quantitatively determine the cycling of conventional generators are proposed, including (1) mileage and number of direction changes in balancing service and (2) ramp statistics (or half-cycle) analysis. The proposed methods are tested on the NV Energy power system model. Simulation results demonstrate a significant impact of increased solar capacity on balancing service and cycling of conventional generators. Busy hours are identified for different study scenarios with various solar penetration levels. This study provides a basis for evaluating the wear and tear of the conventional generators in the solar integration process in the Nevada power system. Index Terms—balancing requirement, conventional generator, cycling and movement, load following, regulation, renewable energy, solar integration

ok↗

Advanced Energy Design Guide for K-12 School Buildings (AEDG) Training: Cooperative Research and Development Final Report, CRADA Number CRD-18-00761

U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO), Commercial Buildings Integration (CBI) Program supports the adoption of zero energy ready buildings design practices through targeted Science, Technology, Engineering, and Mathematics (STEM) workforce development. The National Renewable Energy Laboratory (NREL) identified the opportunity to provided targeted training to those professionals that have the greatest potential to impact adoption and successful design outcomes of zero energy ready buildings projects. In January 2018, ASHRAE released Achieving Zero Energy: Advanced Energy Design Guide for K-12 School Buildings (AEDG). The AEDG was developed in collaboration with NREL, American Institute of Architects (AIA), American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE), U.S. Green Building Council (USGBC), and Illuminating Engineers Society (IES). The purpose of this CRADA was to create a partnership between NREL, AIA, ASHRAE, USGBC, and IES to create and host on-demand, web-based training based on the AEDG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Considerations for Developing a Regulatory Roadmap for Distributed Energy Resource (DER) Integration in Colombia

The USAID-NREL Partnership in Colombia, in conjunction with SURE and USEA, selected four action plan teams from the Young Professionals Leadership Program to receive tailored NREL technical assistance to support action plan implementation. The four plans selected represent various aspects associated with planning for the efficient integration of DERs, including electric mobility, residential and commercial energy applications, distributed generation modeling, and regulatory considerations. In response to national grid modernization, decentralization, digitalization, and electrification trends, CREG is looking to update Colombia's electric distribution code, with an emphasis on the integration of electric vehicles and charging stations, but also energy storage systems, non-conventional sources of renewable energy, and other distributed energy resources (DERs). CREG aims to establish the general steps that must be carried out to update the distribution code for the integration of DERs, with a view to the design and development of new markets. The objective of the TA provided to CREG was to support them in identifying and outlining the general processes and approaches to consider when updating Colombia's distribution code for the integration of electric vehicles, distributed renewable energy systems, and energy storage systems, with a view to the design and development of new markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Faster Than You Think: Renewable Energy and Developing Countries

Since 2007, large and unexpected declines in generation costs for renewable energy systems, particularly solar but also wind, combined with policy measures designed to limit greenhouse gas emissions, have created a paradigm shift in energy systems. Variable renewable energy now dominates total investment in electricity power generation systems. This dominance of variable renewable energy in investment has thrust the systems integration task of matching electricity supply with demand to center stage, presenting new challenges for energy policy and planning as well as for the institutional organization of power systems. Despite these challenges, there is ample reason to believe that variable renewables will attain very high levels of penetration into energy systems, particularly in regions well endowed with solar and wind potential. Similar to their success with mobile phone telephony, many developing countries have a significant opportunity to leapfrog directly to more advanced energy technologies that are low cost, reliable, environmentally more benign, and well suited to serving dispersed rural populations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗