Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Asynchronous timing and Doppler recovery in DSP based DPSK modems for fixed and mobile satellite applications

While conventional analog modems employ some kind of clock wave regenerator circuit for synchronous timing recovery, in sampled modem receivers the timing is recovered asynchronously to the incoming data stream, with no adjustment being made to the input sampling rate. All timing corrections are accomplished by digital operations on the sampled data stream, and timing recovery is asynchronous with the uncontrolled, input A/D system. A good timing error measurement algorithm is a zero crossing tracker proposed by Gardner. Digital, speech rate (2400 - 4800 bps) M-PSK modem receivers employing Gardner's zero crossing tracker were implemented and tested and found to achieve BER performance very close to theoretical values on the AWGN channel. Nyguist pulse shaped modem systems with excess bandwidth factors ranging from 100 to 60 percent were considered. We can show that for any symmetric M-PSK signal set Gardner's NDA algorithm is free of pattern jitter for any carrier phase offset for rectangular pulses and for Nyquist pulses having 100 percent excess bandwidth. Also, the Nyquist pulse shaped system is studied on the mobile satellite channel, where Doppler shifts and multipath fading degrade the pi/4-DQPSK signal. Two simple modifications to Gardner's zero crossing tracker enable it to remain useful in the presence of multipath fading.

Koblents, B.↗

Analysis of crustal structure of Venus utilizing residual Line-of-Sight (LOS) gravity acceleration and surface topography data. A trial of global modeling of Venus gravity field using harmonic spline method

To construct Venus' gravity disturbance field (or gravity anomaly) with the spacecraft-observer line of site (LOS) acceleration perturbation data, both a global and a local approach can be used. The global approach, e.g., spherical harmonic coefficients, and the local approach, e.g., the integral operator method, based on geodetic techniques are generally not the same, so that they must be used separately for mapping long wavelength features and short wavelength features. Harmonic spline, as an interpolation and extrapolation technique, is intrinsically flexible to both global and local mapping of a potential field. Theoretically, it preserves the information of the potential field up to the bound by sampling theorem regardless of whether it is global or local mapping, and is never bothered with truncation errors. The improvement of harmonic spline methodology for global mapping is reported. New basis functions, a singular value decomposition (SVD) based modification to Parker & Shure's numerical procedure, and preliminary results are presented.

Fang, Ming↗

Mechanical failure probability of glasses in Earth orbit

Results of five years of earth-orbital exposure on mechanical properties of glasses indicate that radiation effects on mechanical properties of glasses, for the glasses examined, are less than the probable error of measurement. During the 5 year exposure, seven micrometeorite or space debris impacts occurred on the samples examined. These impacts were located in locations which were not subjected to effective mechanical testing, hence limited information on their influence upon mechanical strength was obtained. Combination of these results with micrometeorite and space debris impact frequency obtained by other experiments permits estimates of the failure probability of glasses exposed to mechanical loading under earth-orbit conditions. This probabilistic failure prediction is described and illustrated with examples.

Kinser, Donald L.↗

Comparison of Stress Relief Procedures for Cryogenic Aluminum Mirrors

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter) and an engineering prototype for a potential design for the Next Generation Space Telescope/Multi-Object Spectrograph. IRMOS is a low-to mid-resolution (R = lambda/delta-lambda = 300-3800), near-IR (0.8-2.5 micron) spectrograph which produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arcmin field of view using a commercial MEMS multimirror array device. The instrument operating temperature is 80 K and the design is athermal --- the optical bench and mirrors are machined from aluminum 6061-T651. In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress, which, unless relieved during fabrication, may relieve and distort mirror figure to unacceptable levels at the operating temperature. Other cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of a test program designed to empirically determine the best stress relief procedure for the IRMOS mirrors. Identical test mirrors with spherical and flat optical prescriptions are processed with five different heat treatment formulae from the literature and compared to samples with out any additional processing. After figuring via diamond turning, the mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for several thermal cycles. The heat treatment procedure for the mirrors that yielded the least and most repeatable change in figure error and radius is applied to the IRMOS mirror blanks. We correlate the results of our optical testing with heat treatment and metallographic data.

Ohl, Raymond G.↗

Estimating Random Errors Due to Shot Noise in Backscatter Lidar Observations

In this paper, we discuss the estimation of random errors due to shot noise in backscatter lidar observations that use either photomultiplier tube (PMT) or avalanche photodiode (APD) detectors. The statistical characteristics of photodetection are reviewed, and photon count distributions of solar background signals and laser backscatter signals are examined using airborne lidar observations at 532 nm using a photon-counting mode APD. Both distributions appear to be Poisson, indicating that the arrival at the photodetector of photons for these signals is a Poisson stochastic process. For Poisson-distributed signals, a proportional, one-to-one relationship is known to exist between the mean of a distribution and its variance. Although the multiplied photocurrent no longer follows a strict Poisson distribution in analog-mode APD and PMT detectors, the proportionality still exists between the mean and the variance of the multiplied photocurrent. We make use of this relationship by introducing the noise scale factor (NSF), which quantifies the constant of proportionality that exists between the root-mean-square of the random noise in a measurement and the square root of the mean signal. Using the NSF to estimate random errors in lidar measurements due to shot noise provides a significant advantage over the conventional error estimation techniques, in that with the NSF uncertainties can be reliably calculated from/for a single data sample. Methods for evaluating the NSF are presented. Algorithms to compute the NSF are developed for the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) lidar and tested using data from the Lidar In-space Technology Experiment (LITE). OCIS Codes:

Liu, Zhaoyan↗

Multichannel Networked Phasemeter Readout and Analysis

Netmeter software reads a data stream from up to 250 networked phasemeters, synchronizes the data, saves the reduced data to disk (after applying a low-pass filter), and provides a Web server interface for remote control. Unlike older phasemeter software that requires a special, real-time operating system, this program can run on any general-purpose computer. It needs about five percent of the CPU (central processing unit) to process 20 channels because it adds built-in data logging and network-based GUIs (graphical user interfaces) that are implemented in Scalable Vector Graphics (SVG). Netmeter runs on Linux and Windows. It displays the instantaneous displacements measured by several phasemeters at a user-selectable rate, up to 1 kHz. The program monitors the measure and reference channel frequencies. For ease of use, levels of status in Netmeter are color coded: green for normal operation, yellow for network errors, and red for optical misalignment problems. Netmeter includes user-selectable filters up to 4 k samples, and user-selectable averaging windows (after filtering). Before filtering, the program saves raw data to disk using a burst-write technique.

Edmonds, Karina↗

Validation of IASI Satellite Ammonia Observations at the Pixel Scale Using In Situ Vertical Profiles

Satellite ammonia (NH 3 ) observations provide unprecedented insights into NH3 emissions, spatiotemporal variabilities and trends, but validation with in situ measurements remains lacking. Here, total columns from the Infrared Atmospheric Sounding Interferometer (IASI) were intercompared to boundary layer NH 3 profiles derived from aircraft- and surface-based measurements primarily in Colorado, USA, in the summer of 2014. IASI-NH 3 version 3 near real-time data set compared well to in situ derived columns (windows ±15 km around centroid, ±1 h around overpass time) with a correlation of 0.58, a slope of 0.78 ± 0.14 and an intercept of 2.1 × 10 15 ±1.5 × 10 15 molecules cm −2 . Agreement degrades at larger spatiotemporal windows, consistent with the short atmospheric lifetime of NH 3 . We also examined IASI version 3R data, which relies on temperature retrievals from the ERA Reanalysis, and a third product generated using aircraft-measured temperature profiles. The overall agreement improves slightly for both cases, and neither is biased within their combined measurement errors. Thus, spatiotemporal averaging of IASI over large windows can be used to reduce retrieval noise. Nonetheless, sampling artifacts of airborne NH 3 instruments result in significant uncertainties of the in situ-derived columns. For example, large validation differences exist between ascent and descent profiles, and the assumptions of the free tropospheric NH 3 profiles used above the aircraft ceiling significantly impact the validation. Because short-lived species like NH 3 largely reside within the boundary layer with complex vertical structures, more comprehensive validation is needed across a wide range of environments. More accurate and widespread in situ NH 3 data sets are therefore required for improved validations of satellite products.

Ammonia↗

Fast-neutron Multiplicity Counter for Passive and Active Measurements of Special Nuclear Material

We developed a fast-neutron multiplicity counter (FNMC) based on organic scintillators (liquid and stilbene). The system is able to detect correlated photon and neutron multiplets emitted by fission reactions. We tested the system both in passive and active operation mode, and present the results of the experiments, both carried out at the Zero Power Physics Reactor of Idaho National Laboratory. The system was operated in coincidence mode (with a gate time of 50 nanoseconds) and two calibration-based approaches were used to estimate the 240Pu effective (240Pueff) and 235U mass of the samples. In passive mode, we assayed two types of plutonium metal plates, i.e. PAHN and PANN, with a 240Pueff mass of 4.7 g and 25.05 g per plate, respectively. The 239Pu mass percentage was 74% for the PAHN and 95% for the PANN series. We measured neutrons emitted in coincidence by several plate assemblies, having an overall 240Pueff mass in the 4.7 g to 500 g range. In active mode, we characterized several uranium samples. We used two AmLi sources (~50000 neutrons emitted per second) to induce fission in the samples. The first six measured samples were certified reference materials (CRM, set 149), having a constant enrichment, i.e. 93.2 wt%, and mass in the range between 0.5 and 4 kg. Additionally, we assayed three CRM-146 samples, with constant total mass of 500 g and an enrichment of 20.1 wt%, 52.8 wt% and 93.2 wt%. In both configurations, the system succeeded in estimating the fissile mass of an unknown sample with a statistical uncertainty lower than 1% (4-minute assay) and 7% (10-minute assay), in passive and active mode, respectively. In passive mode, the statistical uncertainty is lower than the one achieved by standard 3He counters for plutonium metal samples of similar mass. The difference between the estimated and the declared 240Pueff mass, i.e., the bias error, measured by the fast neutron multiplicity counter was consistently lower compared to the bias error of a standard thermal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The design and safe operation of experiments in ATR is aided by the operation of the ATR-Critical Facility (ATR-C), a lower-power reactor with the same size and geometry of the ATR. Short, low-power irradiations at the ATR-C are used to study the effects of control devices and test assemblies on the overall power distribution of various core loadings and to compare calculated data for reactor models. A technique was developed at INL to measure fission rates in fuel plate assembly reactors utilizing small, enriched uranium-aluminum (U-Al) alloy monitors, and to support ATR-C irradiations for forty years. Several hundred monitor wires placed throughout the reactor provide fine spatial resolution of the fission rates. A direct correlation exists between the fission rates of the U-Al monitors and the immediately adjacent reactor region. Extensive calibration was previously performed to determine the conversion factor for beta-particle activity of the irradiated U-Al monitors. The fission rate in the U-Al monitors can thus be determined by measuring the beta-particle decay of fission-products following irradiation of the monitors. The American Society for Testing and Materials (ASTM International) has established a standard practice for determining neutron fluence rate by radioactivation of depleted uranium. The ASTM standard practice also measures the concentration of fission-products in the uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of the ASTM standard practice was investigated for ATR-C irradiations and compared to the present method. The need to analyze hundreds of samples for each irradiation posed several challenges. Therefore, practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the expected sources of error for each method were investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating Photocatalysts Using Gamma Radiation

A large amount of attention has been given to photocatalysts using UV radiation as the source of excitation; however, little work has been done to study photocatalysis using higher energy excitation sources, such as gamma or x-rays. During excitation, the photocatalyst absorbs light to produce electron-hole pairs (excitons). These excitons can react with absorbed species to yield reactive radical species that can degrade compounds or induce redox (oxidation-reduction) reactions. Common examples of semiconductor photocatalysts include: TiO{sub 2}, ZnO, Fe{sub 2}O{sub 3}, ZrO{sub 2}, and SnS. This project was conducted to investigate the photocatalytic oxidation of iron using gamma irradiation and several different semiconductor photocatalysts. Photometric Measurements: Photometric determination of Fe{sup II} and Fe{sup III} were made using a Cary 60 UV-Vis Spectrometer over a range of 800 - 200 nm at a scan rate of 60 nm/sec. Ferric (Fe{sup III}) ions have no detectable UV-vis spectrum, thus the absence of a peak in iron-based samples was taken as evidence of Fe{sup III} formation. Solution Preparation: Iron II (Fe{sup II}) standards were made by dissolving FeCl{sub 2}.6H{sub 2}O in deionized water using a sonicator. A solution of 1,10- phenanthroline was made by adding 40 mg of 1,10-phenanthroline to 20 mL of deionized water and sonicating for 60 minutes until a clear solution was obtained. Gamma Radiation Tests: Irradiated samples were exposed to Co-60 gamma radiation (1.17 MeV gamma) at a dose rate of ∼1 x 10{sup 5} Rad/hr Co-60. All samples were irradiated in glass scintillation vials. The presence of 30 mg of SnS reduces the amount of Fe{sup II} in solutions under gamma irradiation relative to samples with no SnS added. Fe{sup II} concentration decreases as irradiation time increases. This effect is enhanced when SnS is present. Fe{sup II} appears to decrease linearly with time. We found that the addition of SnS semiconductor, when combined with gamma radiation, oxidized more Fe{sup II} in the FeCl{sub 2} solution than gamma radiation alone. This suggests that SnS can be used as a photocatalyst using gamma radiation as the excitation source, although more detailed experiments are needed to confirm this belief. The next phase of this project would be to refine the preliminary results by determining exact quantities of SnS semiconductor and gamma radiation that induce sufficient redox. Repeated experiments with more samples could also give more data points for a chance at more representative and accurate data with error bars and standard deviations. Also, other semiconductors could possibly be tested to see how their effect on redox chemistry compares to that of SnS. The scope of this project could also be extended to include other metal or organic solutions to see if similar redox could be obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

State estimation Kalman filter using optical processings Noise statistics known

Reference is made to a study by Casasent et al. (1983), which gave a description of a frequency-multiplexed acoustooptic processor and showed how it was capable of performing all the individual operations required in Kalman filtering. The data flow and organization of all required operations however, were not detailed in that study. Consideration is given here to a simpler Kalman filter state estimation problem. Equally spaced time-sampled intervals (k times T sub s, with k the iterative time index) are assumed. It is further assumed that the system noise vector w and the measurement noise vector v are uncorrelated and Gaussian distributed and that the noise statistics (Q and R) and the system model (Phi, Gamma, H) are known. The error covariance matrix P and the extrapolated error covariance matrix M can thus be precomputed and the Kalman gain matrix K sub k can be precomputed and stored for each input time sample.

Jackson, J.↗

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra is described. The fluorescent intensity If is linearly proportional to the absorption coefficient μ. For studies of surface structures around an element (κ) the fluorescence detection is often the mode of choice. However, the measurement may suffer from a self-absorption (SA) effect which nonlinearly distorts the spectra. The effect is severe when κ is concentrated or the measurements are carried out in certain geometries. Here, the correlations among emission events in compounds are examined following resonance X-ray core-electron excitation within κ. Under conditions leading to SA, If emitted from κ apparently has a conjugated relationship with the fluorescent intensities simultaneously emitted from other elements (ξ). Normalizing the former (κ) by the latter (ξ) will largely remove SA effects and reduce this nonlinear problem to a tractable linear problem. This does result in a moderate reduction of the spectral amplitude due to the so-called secondary emission from ξ excited by the emission from κ. Nonetheless, the resulting spectra will allow one to accurately determine bond distances and disorder and, in some respects, can be superior to spectra obtained via the absorption channel. For μξ < μκ and grazing incidence geometry, the amplitude reduction can be small and simple normalization is sufficient to restore the spectral integrity with remarkable accuracy. This has been instrumental in unravelling the surface and subsurface structures around cations in amorphous Ga–In–O and Zn–Sn–O films which are otherwise inaccessible due to severe SA effects. This method has also been applied to several samples with μξ ≃ μκ to examine its applicability. For these samples, the amplitude reduction is 12 ± 4% versus their standards for the data measured with the classical 45°/45° geometry. This experimental method is easy to implement. Since If from κ and ξ are measured by the same detector system, it is also superior to other methods in removing systematic errors such as detector system nonlinearity, electronic noise, and some beam instabilities, and in removing spectral imperfections due to, for example, SA effects, diffraction effects and sample inhomogeneity. The distortions resulting from the latter can be severe in the spectra measured in transmission mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure Analysis for LAVA-OVEN

The Lunar Advanced Volatiles Analysis (LAVA) and the Oxygen Volatiles Extraction Node (OVEN) are subsystems included in the Regolith Environment Science, and Oxygen Lunar Volatiles Extraction (RESOLVE) payload bound for the Moon in 2019. This Resource Prospector Mission (RPM) has the objective of landing on a shadowed region of the Moons South Pole to collect data and determine whether the resources could be effectively used for space exploration systems. The quantification of the resources will help understand if it can adequately minimize materials carried from Earth by: providing life support, propellants, construction materials or energy supply to the payload or crew. This paper outlines the procedures done for the pressure analysis of the LAVA-OVEN (LOVEN) Integration Testing. The pressure analysis quantifies how much gases and water are present in the sample tested during the Engineering Testing Unit (ETU) phase of instrument development. Ultimately the purpose of these tests is to improve the estimate of the amount of water in each Lunar sample and reduce the time necessary for this estimate. The governing principle that was used for the analysis is the Ideal Gas Law, PV=nRT where P stands for pressure, V for volume, n for number of moles, R being the gas constant and T for temperature. We also estimate the errors involved in these measured and derived quantities since a key objective of the mission is to estimate the quantity of volatiles present in the lunar samples introduced into OVEN.

Lunar↗

Effects of model error on control of large flexible space antenna with comparisons of decoupled and linear quadratic regulator control procedures

An analysis was performed to determine the effects of model error on the control of a large flexible space antenna. Control was achieved by employing two three-axis control-moment gyros (CMG's) located on the antenna column. State variables were estimated by including an observer in the control loop that used attitude and attitude-rate sensors on the column. Errors were assumed to exist in the individual model parameters: modal frequency, modal damping, mode slope (control-influence coefficients), and moment of inertia. Their effects on control-system performance were analyzed either for (1) nulling initial disturbances in the rigid-body modes, or (2) nulling initial disturbances in the first three flexible modes. The study includes the effects on stability, time to null, and control requirements (defined as maximum torque and total momentum), as well as on the accuracy of obtaining initial estimates of the disturbances. The effects on the transients of the undisturbed modes are also included. The results, which are compared for decoupled and linear quadratic regulator (LQR) control procedures, are shown in tabular form, parametric plots, and as sample time histories of modal-amplitude and control responses. Results of the analysis showed that the effects of model errors on the control-system performance were generally comparable for both control procedures. The effect of mode-slope error was the most serious of all model errors.

Hamer, H. A.↗

Comparative analysis of techniques for evaluating the effectiveness of aircraft computing systems

Performability analysis is a technique developed for evaluating the effectiveness of fault-tolerant computing systems in multiphase missions. Performability was evaluated for its accuracy, practical usefulness, and relative cost. The evaluation was performed by applying performability and the fault tree method to a set of sample problems ranging from simple to moderately complex. The problems involved as many as five outcomes, two to five mission phases, permanent faults, and some functional dependencies. Transient faults and software errors were not considered. A different analyst was responsible for each technique. Significantly more time and effort were required to learn performability analysis than the fault tree method. Performability is inherently as accurate as fault tree analysis. For the sample problems, fault trees were more practical and less time consuming to apply, while performability required less ingenuity and was more checkable. Performability offers some advantages for evaluating very complex problems.

Hitt, E. F.↗

A geostatistical analysis of small-scale spatial variability in bacterial abundance and community structure in salt marsh creek bank sediments

Small-scale variations in bacterial abundance and community structure were examined in salt marsh sediments from Virginia's eastern shore. Samples were collected at 5 cm intervals (horizontally) along a 50 cm elevation gradient, over a 215 cm horizontal transect. For each sample, bacterial abundance was determined using acridine orange direct counts and community structure was analyzed using randomly amplified polymorphic DNA fingerprinting of whole-community DNA extracts. A geostatistical analysis was used to determine the degree of spatial autocorrelation among the samples, for each variable and each direction (horizontal and vertical). The proportion of variance in bacterial abundance that could be accounted for by the spatial model was quite high (vertical: 60%, horizontal: 73%); significant autocorrelation was found among samples separated by 25 cm in the vertical direction and up to 115 cm horizontally. In contrast, most of the variability in community structure was not accounted for by simply considering the spatial separation of samples (vertical: 11%, horizontal: 22%), and must reflect variability from other parameters (e.g., variation at other spatial scales, experimental error, or environmental heterogeneity). Microbial community patch size based upon overall similarity in community structure varied between 17 cm (vertical) and 35 cm (horizontal). Overall, variability due to horizontal position (distance from the creek bank) was much smaller than that due to vertical position (elevation) for both community properties assayed. This suggests that processes more correlated with elevation (e.g., drainage and redox potential) vary at a smaller scale (therefore producing smaller patch sizes) than processes controlled by distance from the creek bank. c2002 Federation of European Microbiological Societies. Published by Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

Effect of sample quantity on the results of ferromagnetic resonance studies of lunar samples

Quantitative ferromagnetic resonance (FMR) measurements at 9.5 and 35 GHz were made on lunar fines in order to determine the amount of single domain FE(0) and to ascertain the effect of sample quantity on the results of these experiments. Samples containing more than 10 micrograms of Fe(0) in an X-band TE(104) cavity, or more than 0.11 micrograms in a Ka-band cavity can cause errors greater than 1% in the quantitative determination of Fe(0), as well as cause anomalous broadening of the FMR line. Theoretical calculations were derived to show this effect which results from a nonlinear response of the FMR experiment with the sample quantity. Using samples of nominal weights, the amount of Fe(0) determined at 34 GHz was 1.1-1.8 times greater than at 9.5 GHz, while the linewidths increased by a factor of 1.2. As the particle size increases, the ratio of Fe(0) determined at 35 GHz to that determined at 9.5 GHz increases, suggesting that the additional iron is due to larger spheroidal particles which change from multidomain to single domain at the larger fields.

Goldberg, J. B.↗

Tracer techniques for urine volume determination and urine collection and sampling back-up system

The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

Ramirez, R. V.↗