Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

cclib 2.0: An updated architecture for interoperable computational chemistry

Interoperability in computational chemistry is elusive, impeded by the independent development of software packages and idiosyncratic nature of their output files. The cclib library was introduced in 2006 as an attempt to improve this situation by providing a consistent interface to the results of various quantum chemistry programs. The shared API across programs enabled by cclib has allowed users to focus on results as opposed to output and to combine data from multiple programs or develop generic downstream tools. Initial development, however, did not anticipate the rapid progress of computational capabilities, novel methods, and new programs; nor did it foresee the growing need for customizability. Here, we recount this history and present cclib 2, focused on extensibility and modularity. We also introduce recent design pivots—the formalization of cclib’s intermediate data representation as a tree-based structure, a new combinator-based parser organization, and parsed chemical properties as extensible objects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 {+-} 1.5% error, 4.4 {+-} 3.0% error for CT, and 3.1 {+-} 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of the OECD-NEA Working Party on International Nuclear Data Evaluation Cooperation (WPEC)

The OECD Nuclear Energy Agency (NEA) Working Party on International Nuclear Data Evaluation Cooperation (WPEC) was established in 1989 to facilitate collaboration in nuclear data activities. Over its thirty year history, different Subgroups have been created to address topics in nearly every aspect of nuclear data, including: experimental measurements, evaluation, validation, model development, quality assurance of databases and the development of software tools. WPEC has recently completed activities on fission yield evaluation, the general nuclear database structure (GNDS) to replace the ENDF-6 format, methods to provide feedback to evaluation, studies of specific capture cross sections, new methods in thermal scattering kernel evaluation and the Collaborative International Evaluated Library Organisation (CIELO) Pilot Project. Ongoing activities in GNDS application programming interface (API) development, methods for covariance evaluation and quality assurance in nuclear data validation using the International Criticality Safety Benchmark Evaluation Project (ICSBEP) database are complemented by the work of two Expert Groups that oversee the High-Priority Request List (HPRL) for Nuclear Data and the continuous development of the GNDS. New activities on the use of integral experiments for nuclear data validation and adjustment, as well as the use of the Shielding Integral Benchmark Archive and Database (SINBAD) for validation have begun and will be coordinated alongside future Subgroups. After three decades we will review the status of WPEC, how it integrates other collections and activities organised by the NEA and how it dovetails with the initiatives of the IAEA and other bodies to effectively coordinate international activities in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Simulation Tools for Muon-Based Accelerators

The project developed new software tools incorporating the most accurate theoretical calculations and experimental data available for crucial and not-yet-considered physics processes specific to muon accelerators. These new tools were applied to modeling muon ionization cooling channels for a muon collider or a neutrino factory, the facilities that have the potential to discover and explore new exciting fundamental physics but require the development of demanding technologies and innovative concepts. G4beamline, COSY Infinity, and WARP computer codes are particularly well-suited for addressing muon accelerator modeling problems. G4beamline was chosen for its flexibility and modularity, and for being one of the de facto standard codes used by the muon accelerator community. COSY was selected for speed, ability to take into account high-order nonlinear effects essential for the large beams under consideration, and availability of built-in optimization tools. WARP was chosen for its space charge calculation capabilities, speed and flexibility of implementing new lattice elements such as RF cavities. This final technical report summarizes the efforts on implementing advanced new tools in these computer codes addressing the shortcomings in modeling muon physics processes and using these tools to model muon ionization cooling channels.

43 PARTICLE ACCELERATORS↗

Using an EPID for patient-specific VMAT quality assurance

Purpose: A patient-specific quality assurance (QA) method was developed to verify gantry-specific individual multileaf collimator (MLC) apertures (control points) in volumetric modulated arc therapy (VMAT) plans using an electronic portal imaging device (EPID). Methods: VMAT treatment plans were generated in an Eclipse treatment planning system (TPS). DICOM images from a Varian EPID (aS1000) acquired in continuous acquisition mode were used for pretreatment QA. Each cine image file contains the grayscale image of the MLC aperture related to its specific control point and the corresponding gantry angle information. The TPS MLC file of this RapidArc plan contains the leaf positions for all 177 control points (gantry angles). In-house software was developed that interpolates the measured images based on the gantry angle and overlays them with the MLC pattern for all control points. The 38% isointensity line was used to define the edge of the MLC leaves on the portal images. The software generates graphs and tables that provide analysis for the number of mismatched leaf positions for a chosen distance to agreement at each control point and the frequency in which each particular leaf mismatches for the entire arc. Results: Seven patients plans were analyzed using this method. The leaves with the highest mismatched rate were found to be treatment plan dependent. Conclusions: This in-house software can be used to automatically verify the MLC leaf positions for all control points of VMAT plans using cine images acquired by an EPID.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beowulf v2.5.3 User Guide: Revision 5

This document is a user guide for the Beowulf (rebranding of Watchmen) tool. It describes how operators can access and utilize the application's functionality. Beowulf is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. These stations are part of a worldwide network to monitor for nuclear explosions, and the data they produce are critical to make the determination of whether a sample is from a nuclear explosion or some other source (i.e., nuclear reactor or medical isotope production facility). Stations deliver their measurements and system status to the International Monitoring System (IMS), which forwards it via email to all subscribers. Beowulf is capable of processing data from several radioxenon station types and development is in progress on a solution for particulate stations. Screening of data in Beowulf may be done by a number of different users such as radionuclide analysts, evaluators, and data quality experts. This guide is provided to assist those users in navigating the application. The term Beowulf is used generically throughout this document to refer to any of the various components in the software application. The user interface that is viewed with a web browser is the primary focus of this user guide. Other components include a database to store measurements and state of health (SOH) data; and the data loader that monitors incoming emails, parses the data, populates the database, does the initial analysis, and routes data for review.

97 MATHEMATICS AND COMPUTING↗

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

54 ENVIRONMENTAL SCIENCES↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

58 GEOSCIENCES↗

SUMMIT v2.1 Summary Report

Standard Unified Modeling Mapping and Integration Toolkit (SUMMIT) is a software capability developed by Sandia National Laboratories (SNL) under the direction and funding of the Department of Homeland Security (DHS), Science and Technology Directorate (S&T). SUMMIT is a scalable platform technology for linking together “best-in-class” models, data, and simulation tools to enable analysts, emergency planners and incident managers to more effectively, economically, and rapidly prepare, analyze, train, and respond to real or potential incidents. The SUMMIT software architecture was created under the Integrated Modeling, Mapping, and Simulation (IMMS) Project and was motivated by the issuance of Homeland Security Presidential Directive 8 (HSPD-8) which called for continuous improvement of our Nation’s preparedness to respond to catastrophic events. Furthermore, a state-of-the-art training and exercise facility called the National Exercise Simulation Center (NESC) was established within the Federal Emergency Management Agency (FEMA) headquarters.

97 MATHEMATICS AND COMPUTING↗

Reduced Models for Chemical Kinetics derived from Parallel Ensemble Simulations of Stirred Reactors

Detailed chemical kinetic models are essential to improve the predictive capability of computational fluid dynamics (CFD) simulations and to impact the development of next generation combustion technologies. However, such detailed kinetic models are beyond the reach of CFD codes due to the computational cost of transporting additional chemical degrees of freedom. Reduced order models for combustion kinetics exploit the presence of lower dimensional manifolds in the state space and require far fewer number of scalars to be transported as part of CFD simulations. In this paper, we describe the software infrastructure developed to allow large ensembles of stirred reactor configurations with detailed chemical kinetics. The canonical reactor simulations are incorporated in a workflow with sparse grid and data reduction methodologies aimed at development of reduced order models. We present results from analyzing the results of the stirred reactor calculations for syngas mixture using principal component analysis (PCA) and neural network methodologies. The results show that nonlinear autoencoder model can surpass PCA in representing the original dataset with far fewer degrees of freedom.

Zhang, Pei↗

Document Set Differentiability Analyzer v. 0.1

Software is a JMP Scripting Language (JSL) script designed to evaluate the differentiability of a set of documents that exhibit some conceptual commonalities but are expected to describe substantially different – thus differentiable – categories. The script imports the document set, a subset of which may be partitioned into an additions pool. The bulk of the documents form a basis pool. Text analysis is applied to the basis pool to extract a mathematical representation of its conceptual content, referred to as the document concept space. A bootstrapping approach is applied to that mathematical representation in order to generate a representation of a large population of randomly designed documents that could be written within the concept space, notably without actually writing the text of those documents.The Kolmogorov-Smirnov test is applied to determine whether the basis pool document set exhibits superior differentiation relative to the randomly designed virtual documents produced by bootstrapping. If an additions pool exists, the documents are incrementally added to the basis pool, choosing the best differentiated remaining document at each step. In this manner the impact of additional categories to overall document set differentiability may be assessed.The software was developed to assess the differentiability of job description document sets. Differentiability is key to meaningful categorization. Poor job differentiation may have economic, ethical, and/or legal implications for an organization. Job categories are used in the assignment of market-based salaries; consequently, poor differentiation of job duties may set the stage for legal challenges if very similar jobs pay differently depending on title, a circumstance that also invites economic waste.The software can be applied to ensure job description set differentiability, reducing legal, economic, and ethical risks to an organization and its people. The extraction of the conceptual space to a mathematical representation enables identification of exceedingly similar documents. In the event of redundancy, two jobs may be collapsed into one. If in the judgment of the subject matter experts the jobs are truly different, the conceptual similarities are highlighted, inviting inclusion of appropriate descriptive content to explicitly characterize those differences. When additional job categories may be needed as the organization changes, the software enables evaluation of proposed additions to ensure that the resulting document set remains adequately differentiated.

Osborn, Thor D.↗

Managing Critical Infrastructures C.I.M. Suite

See how a new software package developed by INL researchers could help protect infrastructure during natural disasters, terrorist attacks and electrical outages. For more information about INL research, visit http://www.facebook.com/idahonationallaboratory.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Software Package Using a Mesh-grid Method for Simulating HPGe Detector Efficiencies

Traditional ways of determining the absolute full-energy peak efficiencies of high-purity germanium (HPGe) detectors are often time consuming, cost prohibitive, or not feasible. A software package, KMESS (Kevin’s Mesh Efficiency Simulator Software), was developed to assist in predicting these efficiencies. It uses a semiempirical mesh-grid method and works for arbitrary source shapes and counting geometries. The model assumes that any gamma-ray source shape can be treated as a large enough collection of point sources. The code is readily adaptable, has a web-based graphical front-end, and could easily be coupled to a 3D scanner. As will be shown, this software can estimate absolute full-energy peak efficiencies with good accuracy in reasonable computation times. It has applications to the field of gamma-ray spectroscopy because it is a quick and accurate way to assist in performing quantitative analyses using HPGe detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BMX: Biological modelling and interface exchange

Abstract High performance computing has a great potential to provide a range of significant benefits for investigating biological systems. These systems often present large modelling problems with many coupled subsystems, such as when studying colonies of bacteria cells. The aim to understand cell colonies has generated substantial interest as they can have strong economic and societal impacts through their roles in in industrial bioreactors and complex community structures, called biofilms, found in clinical settings. Investigating these communities through realistic models can rapidly exceed the capabilities of current serial software. Here, we introduce BMX, a software system developed for the high performance modelling of large cell communities by utilising GPU acceleration. BMX builds upon the AMRex adaptive mesh refinement package to efficiently model cell colony formation under realistic laboratory conditions. Using simple test scenarios with varying nutrient availability, we show that BMX is capable of correctly reproducing observed behavior of bacterial colonies on realistic time scales demonstrating a potential application of high performance computing to colony modelling. The open source software is available from the zenodo repository https://doi.org/10.5281/zenodo.8084270 under the BSD-2-Clause licence.

97 MATHEMATICS AND COMPUTING↗

Analysis, testing, and operation of the MAGI thermal control system

The Aerospace Corporation has completed the development of the Mineral and Gas Identifier (MAGI) sensor - an airborne multi-spectral infrared instrument that is designed to discriminate surface composition and to detect gas emissions from the environment. Sensor performance was demonstrated in a series of flights aboard a Twin Otter aircraft in December 2011 as a stepping stone to a future satellite sensor design. To meet sensor performance requirements the thermal control system was designed to operate the HgCdTe focal plane array (FPA) at 50 K with a 1.79 W heat rejection load to a 44.7 K sink and the optical assembly at 100 K with a 7.5 W heat load to a 82.3 K sink. Two commercial off-theshelf (COTS) Sunpower Stirling cryocoolers were used to meet the instrument’s cooling requirements. A thermal model constructed in Thermal Desktop was used to run parametric studies that guided the mechanical design and sized the two cryocoolers. This paper discusses the development, validation, and operation of the MAGI thermal control system. Detailed energy balances and temperature predictions are presented for various test cases to demonstrate the utility and accuracy of the thermal model. Model inputs included measured values of heat lift as a function of input power and cold tip temperature for the two cryocoolers. These measurements were also used to make predictions of the cool-down behavior from ambient conditions. Advanced heater software was developed to meet unique requirements for both sensor cool-down rate and stability at the set point temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A pencil beam algorithm for helium ion beam therapy

Purpose: To develop a flexible pencil beam algorithm for helium ion beam therapy. Dose distributions were calculated using the newly developed pencil beam algorithm and validated using Monte Carlo (MC) methods. Methods: The algorithm was based on the established theory of fluence weighted elemental pencil beam (PB) kernels. Using a new real-time splitting approach, a minimization routine selects the optimal shape for each sub-beam. Dose depositions along the beam path were determined using a look-up table (LUT). Data for LUT generation were derived from MC simulations in water using GATE 6.1. For materials other than water, dose depositions were calculated by the algorithm using water-equivalent depth scaling. Lateral beam spreading caused by multiple scattering has been accounted for by implementing a non-local scattering formula developed by Gottschalk. A new nuclear correction was modelled using a Voigt function and implemented by a LUT approach. Validation simulations have been performed using a phantom filled with homogeneous materials or heterogeneous slabs of up to 3 cm. The beams were incident perpendicular to the phantoms surface with initial particle energies ranging from 50 to 250 MeV/A with a total number of 10{sup 7} ions per beam. For comparison a special evaluation software was developed calculating the gamma indices for dose distributions. Results: In homogeneous phantoms, maximum range deviations between PB and MC of less than 1.1% and differences in the width of the distal energy falloff of the Bragg-Peak from 80% to 20% of less than 0.1 mm were found. Heterogeneous phantoms using layered slabs satisfied a {gamma}-index criterion of 2%/2mm of the local value except for some single voxels. For more complex phantoms using laterally arranged bone-air slabs, the {gamma}-index criterion was exceeded in some areas giving a maximum {gamma}-index of 1.75 and 4.9% of the voxels showed {gamma}-index values larger than one. The calculation precision of the presented algorithm was considered to be sufficient for clinical practice. Although only data for helium beams was presented, the performance of the pencil beam algorithm for proton beams was comparable. Conclusions: The pencil beam algorithm developed for helium ions presents a suitable tool for dose calculations. Its calculation speed was evaluated to be similar to other published pencil beam algorithms. The flexible design allows easy customization of measured depth-dose distributions and use of varying beam profiles, thus making it a promising candidate for integration into future treatment planning systems. Current work in progress deals with RBE effects of helium ions to complete the model.

60 APPLIED LIFE SCIENCES↗

File format for normalizing radiological concentration exposure rate and dose rate data for the effects of radioactive decay and weathering processes

This report specifies the electronic file format that was agreed upon to be used as the file format for normalized radiological data produced by the software tool developed under this TI project. The NA-84 Technology Integration (TI) Program project (SNL17-CM-635, Normalizing Radiological Data for Analysis and Integration into Models) investigators held a teleconference on December 7, 2017 to discuss the tasks to be completed under the TI program project. During this teleconference, the TI project investigators determined that the comma-separated values (CSV) file format is the most suitable file format for the normalized radiological data that will be outputted from the normalizing tool developed under this TI project. The CSV file format was selected because it provides the requisite flexibility to manage different types of radiological data (i.e., activity concentration, exposure rate, dose rate) from other sources [e.g., Radiological Assessment and Monitoring System (RAMS), Aerial Measuring System (AMS), Monitoring and Sampling). The CSV file format also is suitable for the file format of the normalized radiological data because this normalized data can then be ingested by other software [e.g., RAMS, Visual Sampling Plan (VSP)] used by the NA-84’s Consequence Management Program.

97 MATHEMATICS AND COMPUTING↗