SU-E-T-483: In Vivo Dosimetry of Conventional and Rotational Intensity Modulated Radiotherapy Using Integral Quality Monitor (IQM)

Purpose: To investigate the accuracy, sensitivity and constancy of integral quality monitor (IQM), a new system for in vivo dosimetry of conventional intensity modulated radiation therapy (IMRT) or rotational volumetric modulated arc therapy (VMAT) Methods: A beta-version IQM system was commissioned on an Elekta Infinity LINAC equipped with 160-MLCs Agility head. The stationary and rotational dosimetric constancy of IQM was evaluated, using five-field IMRT and single-or double-arc VMAT plans for prostate and head-and-neck (H&N) patients. The plans were delivered three times over three days to assess the constancy of IQM response. Picket fence (PF) fields were used to evaluate the sensitivity of detecting MLC leaf errors. A single leaf offset was intentionally introduced during delivery of various PF fields with segment apertures of 3×1, 5×1, 10×1, and 24×1cm2. Both 2mm and 5mm decrease in the field width were used. Results: Repeated IQM measurements of prostate and H&N IMRT deliveries showed 0.4 and 0.5% average standard deviation (SD) for segment-by-segment comparison and 0.1 and 0.2% for cumulative comparison. The corresponding SDs for VMAT deliveries were 6.5, 9.4% and 0.7, 1.3%, respectively. Statistical analysis indicates that the dosimetric differences detected by IQM were significant (p < 0.05) in all PF test deliveries. The largest average IQM signal response of a 2 mm leaf error was found to be 2.1% and 5.1% by a 5mm leaf error for 3×1 cm2 field size. The same error in 24×1 cm2 generates a 0.7% and 1.4% difference in the signal. Conclusion: IQM provides an effective means for real-time dosimetric verification of IMRT/ VMAT treatment delivery. For VMAT delivery, the cumulative dosimetry of IQM needs to be used in clinical practice.

60 APPLIED LIFE SCIENCES↗

WE-H-BRC-08: Examining Credentialing Criteria and Poor Performance Indicators for IROC Houston’s Anthropomorphic Head and Neck Phantom

Purpose: To analyze the most recent results of IROC Houston’s anthropomorphic H&N phantom to determine the nature of failing irradiations and the feasibility of altering pass/fail credentialing criteria. Methods: IROC Houston’s H&N phantom, used for IMRT credentialing for NCI-sponsored clinical trials, requires that an institution’s treatment plan must agree with measurement within 7% (TLD doses) and ≥85% pixels must pass 7%/4 mm gamma analysis. 156 phantom irradiations (November 2014 – October 2015) were re-evaluated using tighter criteria: 1) 5% TLD and 5%/4 mm, 2) 5% TLD and 5%/3 mm, 3) 4% TLD and 4%/4 mm, and 4) 3% TLD and 3%/3 mm. Failure/poor performance rates were evaluated with respect to individual film and TLD performance by location in the phantom. Overall poor phantom results were characterized qualitatively as systematic (dosimetric) errors, setup errors/positional shifts, global but non-systematic errors, and errors affecting only a local region. Results: The pass rate for these phantoms using current criteria is 90%. Substituting criteria 1-4 reduces the overall pass rate to 77%, 70%, 63%, and 37%, respectively. Statistical analyses indicated the probability of noise-induced TLD failure at the 5% criterion was <0.5%. Using criteria 1, TLD results were most often the cause of failure (86% failed TLD while 61% failed film), with most failures identified in the primary PTV (77% cases). Other criteria posed similar results. Irradiations that failed from film only were overwhelmingly associated with phantom shifts/setup errors (≥80% cases). Results failing criteria 1 were primarily diagnosed as systematic: 58% of cases. 11% were setup/positioning errors, 8% were global non-systematic errors, and 22% were local errors. Conclusion: This study demonstrates that 5% TLD and 5%/4 mm gamma criteria may be both practically and theoretically achievable. Further work is necessary to diagnose and resolve dosimetric inaccuracy in these trials, particularly for systematic dose errors. This work is funded by NCI Grant CA180803.

60 APPLIED LIFE SCIENCES↗

Improving multiwell petrophysical interpretation from well logs via machine learning and statistical models

Well-log interpretation estimates in situ rock properties along well trajectory, such as porosity, water saturation, and permeability, to support reserve-volume estimation, production forecasts, and decision making in reservoir development. However, due to measurement errors, variability of well logs caused by multiple measurement vendors, different borehole tools, and nonuniform drilling/borehole conditions, estimations of rock properties with original well logs without proper preprocessing may not be accurate, especially in the context of multiwell estimation. Well-log normalization techniques such as two-point scaling and mean-variance normalization are commonly used to improve the robustness of multiwell rock-property estimation. However, these techniques do not consider the correlation between well logs and require subjective knowledge for their effective implementation. To reduce uncertainties and processing time associated with multiwell rock-property estimation from well logs, we develop discriminative adversarial (DA) and linear constraint models for well-log normalization and rock-property estimation. The DA neural network model developed for well-log normalization and interpretation can perform linear and nonlinear well-log normalization while considering the joint distribution of each well log and rock properties. However, the linear constraint model uses an ensemble of predictions from linear models to constrain well-log normalization and rock-property estimation. We also develop a divergence-based type well identification method to select type (training) wells for a test well based on the statistical similarity of associated well-log distributions instead of the interwell distance. We apply the DA model to perform well-log normalization and prediction of permeability for the Seminole San Andres Unit carbonate reservoir. Compared with the permeability predicted with the classical machine learning model without well-log normalization and models with two-point scaling normalization, the DA model yields the most accurate permeability prediction by decreasing the mean-squared error of permeability prediction by 20%–50%.

Geochemistry & Geophysics↗

Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. Conclusions: The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

60 APPLIED LIFE SCIENCES↗

Hierarchical Modeling and Statistical Calibration for Photometric Redshifts

The cosmological exploitation of modern photometric galaxy surveys requires both accurate (unbiased) and precise (narrow) redshift probability distributions derived from broadband photometry. Existing methodologies do not meet these requirements. Standard template fitting delivers interpretable models and errors, but lacks the flexibility to learn inaccuracies in the observed photometry or spectral templates. Machine learning addresses those issues, but requires representative training data, and the resulting models and uncertainties cannot be interpreted in the context of a physical model or outside of the training data. We present a hierarchical modeling approach simultaneously addressing the issues of flexibility, interpretability, and generalization. It combines template fitting with flexible (machine-learning-like) models to correct the spectral templates, model their redshift distributions, and recalibrate the photometric observations. By optimizing the full posterior distribution of the model and solving for its (thousands of) parameters, one can perform a global statistical calibration of the data and the spectral energy distribution (SED) model. We apply this approach to the public Dark Energy Survey Science Verification data and show that it provides more accurate and compact redshift posterior distributions than existing methods, as well as insights into residual photometric and SED systematics. Here, the model is causal and makes predictions for future data (e.g., additional photometric bandpasses), and its internal parameters and components are interpretable. This approach does not formally require the training data to be complete or representative; in principle, it can even work in regimes in which few or no spectroscopic redshifts are available.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupling localized Noah-MP-Crop model with the WRF model improved dynamic crop growth simulation across Northeast China

Croplands play a critical role in regulating the energy and moisture exchanges between the land surface and atmosphere. However, the interactions between cropland and climate are usually poorly represented due to a lack of detailed representation in crop types and field management. Here, we coupled the Noah-MP-Crop model with the state-of-the-art Weather Research and Forecasting (WRF) model to explore and evaluate the crop growth dynamics in response to climate variations across Northeast China. The default parameters of the crop model were not exactly suitable for the agricultural ecosystems in Northeast China. The detailed cropland distribution, and crop phenology parameters including growing degree days (GDD) and planting (harvesting) date were first created using multi-source remote sensing products and reanalysis data, and was then successfully used to simulate the growth and yield for corn and soybean and associated energy exchanges. We also optimized and calibrated other crop parameters using the time-series of the Moderate Resolution Imaging Spectroradiometer (MODIS) land surface products. The modified crop model substantially improved the simulation of crop growth, plant physiology, and biomass accumulation for both corn and soybean. Coupling the localized dynamic crop model into the WRF led to considerable decreases in the simulated mean-absolute-errors (MAEs) and biases of the leaf area index, evapotranspiration, and gross primary production compared with the MODIS observed values. Compared with the statistical yield from each province, the modified crop model underestimated the corn yield from 11.1% to 48.6%, whereas overestimated the soybean yield from 16.5% to 162.6%.

54 ENVIRONMENTAL SCIENCES↗

Microscopic theory of onset of decaging and bond-breaking activated dynamics in ultradense fluids with strong short-range attractions

We theoretically study thermally activated “in cage” elementary dynamical processes that precede full structural relaxation in ultra-dense particle liquids interacting via strong short range attractive forces. The analysis is based on a microscopic theory formulated at the particle trajectory level built on the dynamic free energy concept and an explicit treatment of how attractive forces control the formation and lifetime of physical bonds. Mean time scales for bond breaking, the early stage of cage escape, and non-Fickian displacement by a fixed amount are analyzed in the repulsive glass, bonded repulsive (attractive) glass, fluid, and dense gel regimes. The theory predicts a strong length-scale-dependent growth of these time scales with attractive force strength at fixed packing fraction, a much weaker slowing down with density at fixed attraction strength, and a strong decoupling of the shorter bond breaking time with the other two time scales that are controlled mainly by perturbed steric caging. All results are in good accord with simulations, and additional testable predictions are made. In conclusion, the classic statistical mechanical projection approximation of replacing all bare attractive and repulsive forces with a single effective force determined by pair structure incurs major errors for describing processes associated with thermally activated escape from transiently localized states.

36 MATERIALS SCIENCE↗

Hanford low-activity waste glass composition-temperature-melt viscosity relationships

This study developed a model for predicting viscosity of alkali-alumino-borosilicate glass melts as functions of composition and temperature. The model is based on a total of 3935 viscosity-temperature data from 574 glasses with viscosity values ranging from 2.53 to 7260 Poise (P) in the temperature range of 900–1260°C. Several different model forms were surveyed, including those based on Arrhenius, Vogel-Fulcher-Tammann, Avramov-Milchev, and Mauro-Yue-Ellison-Gupta-Allen. For each of these models, combinations of the temperature-independent parameters were fitted to composition. It was found that generally fitting more than one temperature-independent parameter as functions of composition resulted in overfitting. The Avramov-Milchev-based model was found to best represent the Hanford low-activity waste glass melt viscosity data based on model fit and validation statistics. A 21-term partial quadratic mixture model was recommended for use. This model predicts melt viscosity with a root-mean square error of .1736 ln(P), which is similar to the error in viscosity measurements from replicate glass analyses of .1383 ln(P). Viscosity was found to be most increased by SiO 2 > Al 2 O 3 > ZrO 2 > SnO 2 and most decreased by Li 2 O > Na 2 O > B 2 O 3 > CaO > K 2 O > MgO, at temperatures from 900 to 1260°C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-E-18A-09: Application of a Channelized Hotelling Observer Model to Evaluate Angiographic Imaging Equipment

Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm{sup 2} and 0.1842 mm{sup 2}, respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model provides a framework to evaluate angiographic system performance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-672: Real-Time In Vivo Dosimeters Using LiPCDA and Optical Fibers

Purpose: To investigate dosimeter prototypes made with lithium pentacosa-10,12-diynoate (LiPCDA, the material used in GafChromic EBT films) and optical fibers for their suitability in real-time in vivo measurements. Methods: The prototypes, made with 500 µm plastic optical fibers and 8.5 µm thickness of LiPCDA at fiber tip, were irradiated with a 6 MV beam. To investigate the efficacy of pre-irradiation calibration, the probes were irradiated to 2 Gy twice, with 5 minutes in between. Net optical density values (netOD) around the main absorbance peak were compared, and effect of correcting second measurement by the first was assessed. Ageing was assessed by irradiating two prototypes to 2 Gy and comparing the netOD to that obtained for 15 prototypes from the same batch 12–14 months earlier. To measure angular dependence, the probes were pre-irradiated with beam perpendicular to fiber axis and then, 5 minutes later either perpendicular or parallel to fiber axes. The thickness-corrected netOD measurements were compared. Results: Standard deviation of netOD for probes of the same batch was measured to be 5–6%. When netOD was corrected for material thickness by using results from the first irradiation, the standard deviation decreased to 1.3%. This was comparable to the uncertainty in measurements observed with a single probe and is attributed to variations in light output, spectrometer noise and splitter-to-probe connection variations. Comparison of netOD values obtained a year apart failed to illustrate statistically significant decrease in sensitivity due to ageing (0.38 ± 0.03 and 0.3656 ± 0.0003). NetOD measured with MV beam parallel to fiber was within error of netOD measured with MV beam perpendicular to fiber. Conclusion: Current prototype construction allows for shelf life of at least one year. With material thickness corrected for, the prototypes can measure dose with an uncertainty below 2% at a given energy and dose rate. This work has been funded by the Ontario Centres of Excellence Market Readiness grant. The authors have no conflict of interest to declare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 03: Energy dependence of a clinical probe-format calorimeter and its pertinence to absolute photon and electron beam dosimetry

Purpose: To evaluate the intrinsic and absorbed-dose energy dependence of a small-scale graphite calorimeter probe (GPC) developed for use as a routine clinical dosimeter. The influence of charge deposition on the response of the GPC was also assessed by performing absolute dosimetry in clinical linac-based electron beams. Methods: Intrinsic energy dependence was determined by performing constant-temperature calorimetry dose measurements in a water-equivalent solid phantom, under otherwise reference conditions, in five high-energy photon (63.5 < %dd(10){sub X} < 76.3), and five electron (2.3 cm < R{sub 50} < 8.3 cm) beams. Reference dosimetry was performed for all beams in question using an Exradin A19 ion chamber with a calibration traceable to national standards. The absorbed-dose component of the overall energy dependence was calculated using the EGSnrc egs-chamber user code. Results: A total of 72 measurements were performed with the GPC, resulting in a standard error on the mean absorbed dose of better than 0.3 % for all ten beams. For both the photon and electron beams, no statistically-significant energy dependence was observed experimentally. Peak-to-peak, variations in the relative response of the GPC across all beam qualities of a given radiation type were on the order of 1 %. No effects, either transient or permanent, were attributable to the charge deposited by the electron beams. Conclusions: The GPC’s apparent energy-independence, combined with its well-established linearity and dose rate independence, make it a potentially useful dosimetry system capable measuring photon and electron doses in absolute terms at the clinical level.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Day Building Load Predictions based on Limited Input Features Using an On-Line Laterally Primed Adaptive Resonance Theory Artificial Neural Network.

Optimal integration of thermal energy storage within commercial building applications requires accurate load predictions. Several methods exist that provide an estimate of a buildings future needs. Methods include component-based models and data-driven algorithms. This work implemented a previously untested algorithm for this application that is called a Laterally Primed Adaptive Resonance Theory (LAPART) artificial neural network (ANN). The LAPART algorithm provided accurate results over a two month period where minimal historical data and a small amount of input types were available. These results are significant, because common practice has often overlooked the implementation of an ANN. ANN have often been perceived to be too complex and require large amounts of data to provide accurate results. The LAPART neural network was implemented in an on-line learning manner. On-line learning refers to the continuous updating of training data as time occurs. For this experiment, training began with a singe day and grew to two months of data. This approach provides a platform for immediate implementation that requires minimal time and effort. The results from the LAPART algorithm were compared with statistical regression and a component-based model. The comparison was based on the predictions linear relationship with the measured data, mean squared error, mean bias error, and cost savings achieved by the respective prediction techniques. The results show that the LAPART algorithm provided a reliable and cost effective means to predict the building load for the next day.

25 ENERGY STORAGE↗

{gamma}-RAY SPECTRAL EVOLUTION OF NGC 1275 OBSERVED WITH FERMI LARGE AREA TELESCOPE

We report on a detailed investigation of the high-energy {gamma}-ray emission from NGC 1275, a well-known radio galaxy hosted by a giant elliptical located at the center of the nearby Perseus cluster. With the increased photon statistics, the center of the {gamma}-ray-emitting region is now measured to be separated by only 0.46 arcmin from the nucleus of NGC 1275, well within the 95% confidence error circle with radius {approx_equal}1.5 arcmin. Early Fermi Large Area Telescope (LAT) observations revealed a significant decade-timescale brightening of NGC 1275 at GeV photon energies, with a flux about 7 times higher than the one implied by the upper limit from previous EGRET observations. With the accumulation of one year of Fermi-LAT all-sky-survey exposure, we now detect flux and spectral variations of this source on month timescales, as reported in this paper. The average >100 MeV {gamma}-ray spectrum of NGC 1275 shows a possible deviation from a simple power-law shape, indicating a spectral cutoff around an observed photon energy of {epsilon}{sub {gamma}} = 42.2 {+-} 19.6 GeV, with an average flux of F{sub {gamma}} = (2.31 {+-} 0.13) x 10{sup -7} photons cm{sup -2} s{sup -1} and a power-law photon index, {Gamma}{sub {gamma}} = 2.13 {+-} 0.02. The largest {gamma}-ray flaring event was observed in 2009 April-May and was accompanied by significant spectral variability above {epsilon}{sub {gamma} {approx}}> 1-2 GeV. The {gamma}-ray activity of NGC 1275 during this flare can be described by a hysteresis behavior in the flux versus photon index plane. The highest energy photon associated with the {gamma}-ray source was detected at the very end of the observation, with the observed energy of {epsilon}{sub {gamma}} = 67.4 GeV and an angular separation of about 2.4 arcmin from the nucleus. In this paper we present the details of the Fermi-LAT data analysis, and briefly discuss the implications of the observed {gamma}-ray spectral evolution of NGC 1275 in the context of {gamma}-ray blazar sources in general.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Kitaev honeycomb model on a neutral-atom quantum computer

Quantum simulations of many-body systems are among the most promising applications of quantum computers. In particular, models based on strongly correlated fermions are central to our understanding of quantum chemistry and materials problems, and can lead to exotic, topological phases of matter. However, owing to the non-local nature of fermions, such models are challenging to simulate with qubit devices. Here we realize a digital quantum simulation architecture for two-dimensional fermionic systems based on reconfigurable atom arrays. We utilize a fermion-to-qubit mapping based on Kitaev’s model on a honeycomb lattice, in which fermionic statistics are encoded using long-range entangled states. We prepare these states efficiently using measurement and feedforward, realize subsequent fermionic evolution through Floquet engineering with tunable entangling gates interspersed with atom rearrangement, and improve results with built-in error detection. Leveraging this fermion description of the Kitaev spin model, we efficiently prepare topological states across its complex phase diagram and verify the non-Abelian spin-liquid phase by evaluating an odd Chern number. We further explore this two-dimensional fermion system by realizing tunable dynamics and directly probing fermion exchange statistics. Finally, we simulate strong interactions and study the dynamics of the Fermi–Hubbard model on a square lattice. These results pave the way for digital quantum simulations of complex fermionic systems for materials science, chemistry and high-energy physics.

atomic and molecular physics↗

Quantitative metrics for evaluating thermonuclear design codes and physics models applied to the National Ignition Campaign

In this study, physics models and design codes for hot dense plasmas undergoing thermonuclear burn are evaluated objectively using statistical metrics that compare the difference between calculations and data relative to the experimental uncertainties. The analysis is applied to the National Ignition Campaign (NIC) because it is relevant, comprehensive, and well documented. The statistics confirm that a key process afflicting NIC performance is mix driven by hydrodynamic instabilities as approximated here using the KL model [G. Dimonte and R. Tipton, Phys. Fluids 18, 085101 (2006)]. New physics models are also presented for instability-driven magnetic fields [B. Srinivasan et al., Phys. Rev. Lett. 108, 165002 (2012)] and the Coulomb logarithm for electron–ion thermal relaxation [G. Dimonte and J. Daligault, Phys. Rev. Lett. 101, 135001 (2008)]. The plasma-generated magnetic fields improve the agreement between code and data in a statistically significant manner by reducing the electron thermal conduction in the hot-spot via the Hall term. The Coulomb logarithm is presented in a numerically practical form that incorporates recent theoretical advances. However, it does not improve the agreement between the code and data because the thermal relaxation is so fast in non-ignited NIC plasmas that the typical 20% error does not change the tight coupling between electrons and ions. Even with these improved physics models, the one-dimensional simulations presented here are not able to describe the high-convergence NIC implosions in a statistically acceptable manner. Of the heroic multi-dimensional simulations of Clark et al. [Phys. Plasmas 23, 056302 (2016)], only those in three-dimensions satisfy the statistical acceptance criterion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DABAM: An open-source database of X-ray mirrors metrology

An open-source database containing metrology data for X-ray mirrors is presented. It makes available metrology data (mirror heights and slopes profiles) that can be used with simulation tools for calculating the effects of optical surface errors in the performances of an optical instrument, such as a synchrotron beamline. A typical case is the degradation of the intensity profile at the focal position in a beamline due to mirror surface errors. This database for metrology (DABAM) aims to provide to the users of simulation tools the data of real mirrors. The data included in the database are described in this paper, with details of how the mirror parameters are stored. An accompanying software is provided to allow simple access and processing of these data, calculate the most usual statistical parameters, and also include the option of creating input files for most used simulation codes. In conclusion, some optics simulations are presented and discussed to illustrate the real use of the profiles from the database.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗