Supersonic hot jet ablative testing and analysis of boron nitride nanotube hybrid composites

Boron nitride nanotubes (BNNTs) are high-strength, high-modulus nanotubes with high thermal and oxidative stabilities. Two hybrid composites were prepared with satin weave carbon fiber (CF) and resole-type phenolic resin: one with surface layers of BNNTs and one with alternating interlayers of BNNTs. The samples were subjected to hot jet tests that simulate realistic high-pressure-temperature conditions to understand the behavior of BNNTs under high-pressure erosion. Adding BNNTs to CF/phenolic laminates enhanced the ablation resistance by reinforcing the char material and mitigated localized thermal damage. Hybrid laminates exhibited up to 14% lower weight loss, 55% increase in flexural modulus, higher thermal diffusivity, and improved char yield and microstructure compared to CF/phenolic samples. The surface layer hybrid had many surviving nanotubes reinforcing the char and crystalline oxide structures that could mitigate further oxygen diffusion. Further, various characterization methods were used to deduce possible mechanisms and their products, indicating that BNNTs could serve as growth templates for direct crystalline boron oxide formation. Overall, hybrid BNNT/CF/phenolic laminates displayed better ablation resistance and favorable microstructure evolution under high-pressure conditions.

42 ENGINEERING↗

Vacuum probe surface sampler

A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

Zahlava, B. A.↗

Specific gravities of lunar materials using helium pycnometry

An existing technique, helium pycnometry, has been adapted for the measurement of specific gravities of lunar samples, where surface areas are low (less than 1 sq m/g) and crushing the sample to a fine powder is highly undesirable. The technique is superior to typical liquid immersion methods, in that it is noncontaminating and, where vuggy or porous samples are concerned, should provide a more accurate (higher) absolute density value. The experimental helium pycnometry measurements have been compared in three instances for two rocks with values calculated from a normative mineral composition. The comparison appears good, however, where differences occur, the direct experimental technique appears to provide the better value and to be capable of indicating density variations within a single rock sample.

Cadenhead, D. A.↗

Reflectance of metallic indium for solar energy applications

An investigation has been conducted in order to compile quantitative data on the reflective properties of metallic indium. The fabricated samples were of sufficiently high quality that differences from similar second-surface silvered mirrors were not apparent to the human eye. Three second-surface mirror samples were prepared by means of vacuum deposition techniques, yielding indium thicknesses of approximately 1000 A. Both hemispherical and specular measurements were made. It is concluded that metallic indium possesses a sufficiently high specular reflectance to be potentially useful in many solar energy applications.

Bouquet, F. L.↗

Mars Science Laboratory Sample Acquisition, Sample Processing and Handling: Subsystem Design and Test Challenges

The Sample Acquisition/Sample Processing and Handling subsystem for the Mars Science Laboratory is a highly-mechanized, Rover-based sampling system that acquires powdered rock and regolith samples from the Martian surface, sorts the samples into fine particles through sieving, and delivers small portions of the powder into two science instruments inside the Rover. SA/SPaH utilizes 17 actuated degrees-of-freedom to perform the functions needed to produce 5 sample pathways in support of the scientific investigation on Mars. Both hardware redundancy and functional redundancy are employed in configuring this sampling system so some functionality is retained even with the loss of a degree-of-freedom. Intentional dynamic environments are created to move sample while vibration isolators attenuate this environment at the sensitive instruments located near the dynamic sources. In addition to the typical flight hardware qualification test program, two additional types of testing are essential for this kind of sampling system: characterization of the intentionally-created dynamic environment and testing of the sample acquisition and processing hardware functions using Mars analog materials in a low pressure environment. The overall subsystem design and configuration are discussed along with some of the challenges, tradeoffs, and lessons learned in the areas of fault tolerance, intentional dynamic environments, and special testing

Jandura, Louise↗

Automation of Column-based Radiochemical Separations: A Comparison of Fluidic, Robotic, and Hybrid Architectures

Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on setting up samples and columns in parallel, and using disposable components so that no sample contacts any surface that any other sample has contacted. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL column bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions four rows of six vials below the columns. The samples are delivered to the columns via a manual 3-port valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is simpler and faster in performing anion exchange procedures for the recovery and purification of plutonium from samples.

99 GENERAL AND MISCELLANEOUS↗

Efficient CO2 and Natural Gas Refinery for Ethylene Production - Catalyst Development for Oxidative Coupling of Methane (OCM)

We designed a new electro-catalyst for oxidative coupling of methane (OCM) reaction, the structure of the Sc doped La0.3Sr0.7TiO3-d (LaSrTi) Sc doping to LaSrTi leading to lattice expansion and more distorted lattice, Investigated the effect of doping on the oxygen vacancy formation energy DFT calculations shows that Sc doping facilitate oxygen vacancy formation. Quantifying the surface basicity of the sample before and after Sc doping Sc doped sample exhibits high surface basicity.

catalysis↗

Analysis Of Tank 38H (HTF-38-14-6, 7) And Tank 43H (HTF-43-14-8, 9) Samples For Support Of The Enrichment Control And Corrosion Control Programs

SRNL performed analysis on Tanks 38H and 43H surface and subsurface supernate samples to support ECP and CCP. The U-235 mass divided by the total U mass ranged from 0.0059 to 0.0060. Uranium concentration ranged from 53.1 mg/L in the Tank 43H surface sample to the 85.1 mg/L in the Tank 38H subsurface sample. The U-235/U and uranium concentration are in line with the prior 2H-Evaporator System ECP samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WHONDRS-GUI: a web application for global survey of surface water metabolites

Background The Worldwide Hydrobiogeochemistry Observation Network for Dynamic River Systems (WHONDRS) is a consortium that aims to understand complex hydrologic, biogeochemical, and microbial connections within river corridors experiencing perturbations such as dam operations, floods, and droughts. For one ongoing WHONDRS sampling campaign, surface water metabolite and microbiome samples are collected through a global survey to generate knowledge across diverse river corridors. Metabolomics analysis and a suite of geochemical analyses have been performed for collected samples through the Environmental Molecular Sciences Laboratory (EMSL). The obtained knowledge and data package inform mechanistic and data-driven models to enhance predictions of outcomes of hydrologic perturbations and watershed function, one of the most critical components in model-data integration. To support efforts of the multi-domain integration and make the ever-growing data package more accessible for researchers across the world, a Shiny/R Graphical User Interface (GUI) called WHONDRS-GUI was created. Results The web application can be run on any modern web browser without any programming or operational system requirements, thus providing an open, well-structured, discoverable dataset for WHONDRS. Together with a context-aware dynamic user interface, the WHONDRS-GUI has functionality for searching, compiling, integrating, visualizing and exporting different data types that can easily be used by the community. The web application and data package are available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1484811 , which enables users to simultaneously obtain access to the data and code and to subsequently run the web app locally. The WHONDRS-GUI is also available for online use at Shiny Server ( https://xmlin.shinyapps.io/whondrs/ ).

59 BASIC BIOLOGICAL SCIENCES↗

Tank 241-AN-107 Study for Semi-Volatile Organics in 2017 Grab Samples and Carbonation of Composite for Solids Precipitation and Caustic Demand

Tank 241-AN-107 waste is known to contain high concentrations of complexing organics, and caustic sodium hydroxide has been added due to depleted free hydroxide in the waste. Eight grab samples were taken in August 2017 for routine chemical analyses. Investigations of the tank’s organic contents and solids precipitation at lower pH levels by CO 2 gas, as well as the performance of caustic demand testing at lower pH ranges were examined. Sub-micron particles were visible, suspended in the supernate, using scanning electron microscopy. Trace amounts of precipitation floating on the surface of the supernate were observed and were collected with the surface liquid samples for investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ISS External Microorganisms: A Payload to Close Planetary Protection Knowledge Gaps for Crewed Missions

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm2 /min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2 to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity)there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces(3). NASA is developing an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes. NASA has developed and tested a tool kit for collecting microbiological samples during EVA(4). This tool kit contains eight commercially available, 23 mm. diameter, foam swabs that can be used to aseptically collect samples while at vacuum. The swabs are individually housed in aluminum canisters that are equipped with 0.2 μm Teflon filters. These filters allow the canisters to equilibrate to pressure changes while preventing microbiological contamination. The canisters will be cleaned and sterilized before flight. Results from ground-based testing indicate that this tool kit is capable of aseptically collecting microbes while at vacuum without becoming contaminated during pressure changes(5). Based on the results of this ground testing we have modified the tool kit to meet NASA safety requirements and improve the ergonomics. We added additional mounting points to the tool kit to give astronauts more options for securing it during use. We also changed the opening mechanism to improve the precision with which swabs can be extracted from the tool kit. We plan to use this kit on an upcoming EVA to collect samples from non-propulsive vents and areas near the U.S. airlock on ISS. These samples will be frozen at -80 ̊C and stored on station until they can be returned to Earth. We will analyze these returned samples using next generation DNA sequencing to determine the community composition and function of external ISS environments. The results of this study will close planetary protection knowledge gaps for crewed missions and will help NASA determine appropriate planetary protection requirements for life support systems. The tool kit will also be useful for collecting aseptic samples on upcoming crewed or robotic missions and could easily be modified to collect samples with organic contamination control requirements as well.

A B Regberg↗

ISS External Microorganisms: A Payload to Close Planetary Protection Knowledge Gaps for Crewed Missions

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm2 /min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2 to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity)there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces(3). NASA is developing an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes. NASA has developed and tested a tool kit for collecting microbiological samples during EVA(4). This tool kit contains eight commercially available, 23 mm. diameter, foam swabs that can be used to aseptically collect samples while at vacuum. The swabs are individually housed in aluminum canisters that are equipped with 0.2 μm Teflon filters. These filters allow the canisters to equilibrate to pressure changes while preventing microbiological contamination. The canisters will be cleaned and sterilized before flight. Results from ground-based testing indicate that this tool kit is capable of aseptically collecting microbes while at vacuum without becoming contaminated during pressure changes(5). Based on the results of this ground testing we have modified the tool kit to meet NASA safety requirements and improve the ergonomics. We added additional mounting points to the tool kit to give astronauts more options for securing it during use. We also changed the opening mechanism to improve the precision with which swabs can be extracted from the tool kit. We plan to use this kit on an upcoming EVA to collect samples from non-propulsive vents and areas near the U.S. airlock on ISS. These samples will be frozen at -80 ̊C and stored on station until they can be returned to Earth. We will analyze these returned samples using next generation DNA sequencing to determine the community composition and function of external ISS environments. The results of this study will close planetary protection knowledge gaps for crewed missions and will help NASA determine appropriate planetary protection requirements for life support systems. The tool kit will also be useful for collecting aseptic samples on upcoming crewed or robotic missions and could easily be modified to collect samples with organic contamination control requirements as well.

A B Regberg↗

ISS External Microorganisms: A Planetary Protection Payload Ready-for-Flight

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm3/min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity) there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces (3). NASA has developed an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes.

M S Bell↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced photoacoustic detection using photonic crystal substrate

This paper demonstrates the enhanced photoacoustic sensing of surface-bound light absorbing molecules and metal nanoparticles using a one-dimensional photonic crystal (PC) substrate. The PC structure functions as an optical resonator at the wavelength where the analyte absorption is strong. The optical resonance of the PC sensor provides an intensified evanescent field with respect to the excitation light source and results in enhanced optical absorption by surface-immobilized samples. For the analysis of a light absorbing dye deposited on the PC surface, the intensity of photoacoustic signal was enhanced by more than 10-fold in comparison to an un-patterned acrylic substrate. The technique was also applied to detect gold nanorods and exhibited more than 40 times stronger photoacoustic signals. The demonstrated approach represents a potential path towards single molecule absorption spectroscopy with greater performance and inexpensive instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗