Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

A high-resolution coherent transition radiation diagnostic for laser-produced electron transport studies (invited)

High-resolution images of the rear-surface optical emission from high-intensity (I{approx}10{sup 19} W/cm{sup 2}) laser illuminated metal foils have been recorded using coherent transition radiation (CTR). CTR is generated as relativistic electrons, generated in high-intensity laser-plasma interactions, exit the target's rear surface and move into vacuum. A transition radiation diagnostic (TRD) records time-integrated images in a 24 nm bandwidth window around {lambda}=529 nm. The optical transmission at {lambda}=1053 nm, the laser wavelength, is 15 orders of magnitude lower than the transmission at the wavelength of interest, {lambda}=527 nm. The detector is a scientific grade charge-coupled device (CCD) camera that operates with a signal-to-noise ratio of 10{sup 3} and has a dynamic range of 10{sup 4}. The TRD has demonstrated a spatial resolution of 1.4 {mu}m over a 1 mm field of view, limited only by the CCD pixel size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-pinch x-ray sources driven by a 1 {mu}s capacitor discharge

X pinches formed from tungsten, molybdenum, titanium, aluminum, and alloys, such as constantan and nichrome with diameters of 13-25 {mu}m, have been imploded with a 300 kA, 1 {mu}s quarter-period capacitor discharge and observed with an array of diagnostics including time-integrated optical photography, x-ray pinhole cameras, x-ray Si photodiodes, a flat crystal spectrograph, and a Nd:YAG laser interferometry/schlieren system. The results of these comprehensive observations are presented. When a single, central hot spot is formed with the right choice of wire and x-ray filter, it is observed to be highly localized, very bright and small enough that point projection radiography can be routinely demonstrated for a simple biological specimen. For an aluminum X pinch, spectroscopic measurements indicate that the hot spots have a plasma density and electron temperature consistent with {approx}10{sup 20} cm{sup -3} and {approx}320-350 eV, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation Of The Seismic Performance Of Masonry Buildings Of The Type 'Gaioleiro', Lisbon (Portugal)

This paper presents a numerical study that aims at the seismic evaluation of the performance of typical Portuguese 'gaioleiro' 19{sup th} century buildings. Numerical analysis was performed using a finite element model and was calibrated with experimental results obtained in 1:3 reduced scale tests done in the LNEC 3D shaking table.With the purpose of defining an adequate strategy for seismic performance evaluation, nonlinear dynamical analysis with time integration and pushover analyses were carried out. In the dynamic analysis, each earthquake is composed by two uncorrected artificial accelerograms compatible with the design response spectrum of EC8. In the pushover analyses it was considered that the seismic action is simulated through a set of horizontal forces proportional to the mass of structure and to the 1{sup st} vibration mode according to the direction being studied.

58 GEOSCIENCES↗

OZSPEC-2: An improved broadband high-resolution elliptical crystal x-ray spectrometer for high-energy density physics experiments (invited)

A novel time, space, and energy-resolved x-ray spectrometer has been developed which produces, in a single snapshot, a broadband and relatively calibrated spectrum of the x-ray emission from a high-energy density laboratory plasma. The opacity zipper spectrometer (OZSPEC-1) records a nearly continuous spectrum for x-ray energies from 240 to 5800 eV in a single shot. The second-generation OZSPEC-2, detailed in this work, records fully continuous spectra on a single shot from any two of these three bands: 270-650, 660-1580, and 1960-4720 eV. These instruments thus record thermal and line radiation from a wide range of plasmas. These instruments' single-shot bandwidth is unmatched in a time-gated spectrometer; conversely, other broadband instruments are either time-integrated (using crystals or gratings), lack spectral resolution (diode arrays), or cover a lower energy band (gratings). The OZSPECs are based on the zipper detector, a large-format (100x35 mm) gated microchannel plate detector, with spectra dispersed along the 100 mm dimension. OZSPEC-1 and -2 both use elliptically bent crystals of OHM, RAP, and/or PET. Individual spectra are gated in 100 ps. OZSPEC-2 provides one-dimensional spatial imaging with 30-50 {mu}m resolution over a 1500 {mu}m field of view at the source. The elliptical crystal design yields broad spectral coverage with resolution E/{delta}E>500, strong rejection of hard x-ray backgrounds, and negligible source broadening for extended sources. Near-term applications include plasma opacity measurements, detailed spectra of inertial fusion Hohlraums, and laboratory astrophysics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical beam profile monitor and residual gas fluorescence at the relativistic heavy ion collider polarized hydrogen jet

A gas fluorescence beam profile monitor has been implemented at the relativistic heavy ion collider (RHIC) using the polarized atomic hydrogen gas jet, which is part of the polarized proton polarimeter. RHIC proton beam profiles in the vertical plane of the accelerator are obtained as well as measurements of the width of the gas jet in the beam direction. For gold ion beams, the fluorescence cross section is sufficiently large so that profiles can be obtained from the residual gas alone, albeit with long light integration times. We estimate the fluorescence cross sections that were not known in this ultrarelativistic regime and calculate the beam emittance to provide an independent measurement of the RHIC beam. This optical beam diagnostic technique, utilizing the beam induced fluorescence from injected or residual gas, offers a noninvasive particle beam characterization and provides visual observation of proton and heavy ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrally Resolved Intensities of Ultra-Dense Hot Aluminum Plasmas

We present a first study of spectroscopic determination of electron temperature and density spatial profiles of aluminum K-shell line emission spectra from laser-shocked aluminum experiments performed at LULI. The radiation emitted by the aluminum plasma was dispersed with an ultra-high resolution spectrograph ({lambda}/{delta}{lambda}{approx_equal}6000). From the recorded films one can extract a set of time-integrated emission lineouts associated with the corresponding spatial region of the plasma. The observed spectra include the Ly{alpha}, He{beta}, He{gamma}, Ly{beta} and Ly{gamma} line emissions and their associated He- and Li-like satellites thus covering a photon energy range from 1700 eV to 2400 eV approximately. The data analysis rely on the ABAKO/RAPCAL computational package, which has been recently developed at the University of Las Palmas de Gran Canaria and takes into account non-equilibrium collisional-radiative atomic kinetics, Stark broadened line shapes and radiation transport calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of ignition scale backlit thin-shell implosions to hohlraum symmetry in the foot of the drive pulse

A necessary condition for igniting indirectly driven inertial confinement fusion spherical capsules on the National Ignition Facility (NIF) is controlling drive flux asymmetry to the 1% level time-integrated over the pulse and with <10%/ns swings during the pulse [J. D. Lindl, P. Amendt, R. L. Berger et al., Phys. Plasmas 11, 339 (2003)]. While drive symmetry during the first 2 ns of the pulse can be inferred by using the re-emission pattern from a surrogate high Z sphere and symmetry during the last 5 ns inferred from the shape of fully imploded capsules, the midportion ({approx_equal}2-10 ns) has been shown to be amenable to detection by the in-flight shape of x-ray backlit thin-shell capsules. In this paper, we present sensitivity studies conducted on the University of Rochester's OMEGA laser [J. Soures, R. L. McCrory, C. P. Verdon et al., Phys. Plasmas 3, 2108 (1996)] of the thin-shell symmetry measurement technique at near NIF-scale for two candidate capsule ablator materials: Ge-doped CH and Cu-doped Be. These experiments use both point and area backlighting to cast 4.7 keV radiographs of thin 1.4 mm initial-diameter Ge-doped CH and Cu-doped Be shells when converged by a factor of {approx_equal}0.5 in radius. Distortions in the position of the transmission limb of the shells resulting from drive asymmetries are measured to an accuracy of a few micrometers, meeting requirements. The promising results to date allow us to compare measured and predicted distortions and by inference drive asymmetries for the first four asymmetry modes as a function of hohlraum illumination conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A broadband absorption spectrometer using light emitting diodes for ultrasensitive, in situ trace gas detection

A broadband absorption spectrometer has been developed for highly sensitive and target-selective in situ trace gas measurements. The instrument employs two distinct modes of operation: (i) broadband cavity enhanced absorption spectroscopy (BBCEAS) is used to quantify the concentration of gases in sample mixtures from their characteristic absorption features, and (ii) periodic measurements of the cavity mirrors' reflectivity are made using step-scan phase shift cavity ringdown spectroscopy (PSCRDS). The latter PSCRDS method provides a stand-alone alternative to the more usual method of determining mirror reflectivities by measuring BBCEAS absorption spectra for calibration samples of known composition. Moreover, the instrument's two modes of operation use light from the same light emitting diode transmitted through the cavity in the same optical alignment, hence minimizing the potential for systematic errors between mirror reflectivity determinations and concentration measurements. The ability of the instrument to quantify absorber concentrations is tested in instrument intercomparison exercises for NO{sub 2} (versus a laser broadband cavity ringdown spectrometer) and for H{sub 2}O (versus a commercial hygrometer). A method is also proposed for calculating effective absorption cross sections for fitting the differential structure in BBCEAS spectra due to strong, narrow absorption lines that are under-resolved and hence exhibit non-Beer-Lambert law behavior at the resolution of the BBCEAS measurements. This approach is tested on BBCEAS spectra of water vapor's 4v+{delta} absorption bands around 650 nm. The most immediate analytical application of the present instrument is in quantifying the concentration of reactive trace gases in the ambient atmosphere. The instrument's detection limits for NO{sub 3} as a function of integration time are considered in detail using an Allan variance analysis. Experiments under laboratory conditions produce a 1{sigma} detection limit of 0.25 pptv for a 10 s acquisition time, which improves with further signal averaging to 0.09 pptv in 400 s. Finally, an example of the instrument's performance under field work conditions is presented, in this case of measurements of the sum of NO{sub 3}+N{sub 2}O{sub 5} concentrations in the marine boundary layer acquired during the Reactive Halogens in the Marine Boundary Layer field campaign.

36 MATERIALS SCIENCE↗

Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Field Measurements in Plasmas: Beyond the Traditional Zeeman Spectroscopy

We discuss a new approach to measure magnetic fields in situations where the magnetic-field properties and/or the plasma regime make the traditional Zeeman spectroscopy inapplicable. The approach is particularly useful when the field direction and/or magnitude vary significantly in the region viewed or during the diagnostic system's integration time, and hence no Zeeman splitting can be observed. Similar difficulty may also occur for high-energy-density conditions, where the Zeeman pattern is often completely smeared, regardless of the field distribution, due to the dominant contributions of the Stark and Doppler broadenings to the spectral-line shapes. In the new approach, the magnetic field is inferred from the comparison of the line-shapes of different fine-structure components of the same multiplet, which practically have the same Stark and Doppler broadenings, but different magnetic-field-induced contributions. Limitations of the new method are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic based modeling for determining absolute atomic oxygen densities in atmospheric pressure helium-oxygen plasmas

Absolute atomic oxygen ground state densities in a radio-frequency driven atmospheric pressure plasma jet, operated in a helium-oxygen mixture, are determined using diagnostic based modeling. One-dimensional numerical simulations of the electron dynamics are combined with time integrated optical emission spectroscopy. The population dynamics of the upper O 3p {sup 3}P ({lambda}=844 nm) atomic oxygen state is governed by direct electron impact excitation, dissociative excitation, radiation losses, and collisional induced quenching. Absolute values for atomic oxygen densities are obtained through comparison with the upper Ar 2p{sub 1} ({lambda}=750.4 nm) state. Results for spatial profiles and power variations are presented and show excellent quantitative agreement with independent two-photon laser-induced fluorescence measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Boron ion source based on planar magnetron discharge in self-sputtering mode

An ion source based on a planar magnetron sputtering device with thermally isolated target has been designed and demonstrated. For a boron sputtering target, high target temperature is required because boron has low electrical conductivity at room temperature, increasing with temperature. The target is well-insulated thermally and can be heated by an initial low-current, high-voltage discharge mode. A discharge power of 16 W was adequate to attain the required surface temperature (400 C), followed by transition of the discharge to a high-current, low-voltage mode for which the magnetron enters a self-sputtering operational mode. Beam analysis was performed with a time-of-flight system; the maximum boron ion fraction in the beam is greater than 99%, and the mean boron ion fraction, time-integrated over the whole pulse length, is about 95%. We have plans to make the ion source steady state and test with a bending magnet. This kind of boron ion source could be competitive to conventional boron ion sources that utilize compounds such as BF3, and could be useful for semiconductor industry application.

43 PARTICLE ACCELERATORS↗

Mapping the ionization state of laser-irradiated Ar gas jets with multiwavelength monochromatic x-ray imaging

Two-dimensional monochromatic images of fast-electron stimulated Ar K{alpha} and He-{alpha} x-ray self-emission have recorded a time-integrated map of the extent of Ar{sup {approx_equal}6+} and Ar{sup 16+} ions, respectively, within a high density (10{sup 20} cm{sup -3} atomic density) Ar plasma. This plasma was produced by irradiating a 2 mm wide clustering Ar gas jet with an ultrahigh intensity (10{sup 19} W/cm{sup 2}, 50 TW) Ti:sapphire laser operating at 800 nm. Spherically bent quartz crystals in the 200 (for K{alpha}) and 201 (for He-{alpha}) planes were used as near-normal incidence reflective x-ray optics. We see that a large (830 {mu}m long) region of plasma emits K{alpha} primarily along the laser axis, while the He-{alpha} emission is confined to smaller hot spot (230 {mu}m long) region that likely corresponds to the focal volume of the f/8 laser beam. X-ray spectra from a Bragg spectrometer operating in the von Hamos geometry indicate that the centroids of the K{alpha} and He-{alpha} emission regions are separated by approximately 330 {mu}m along the laser axis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Wavelets to Search Swift GRBs for QPOs

Motivated by discussion of possible quasi-periodic oscillations in GRB090709A, we examine the wavelet transform of GRB090709A for evidence of the purported QPO. Our approach accounts for both white noise and red noise, with the red noise based on the auto-correlation function of the GRB090709A lightcurve. Encouraged by the robustness of the result, we repeat the analysis on all Swift-triggered GRBs, treating the red noise properties of each GRB individually. We find that time-integrated wavelet peak power agrees well with peak power derived from FFT techniques but the wavelet technique suggests the power is often localized early in the burst.

79 ASTRONOMY AND ASTROPHYSICS↗

Signals of Warped Extra Dimensions at the LHC

We discuss the signatures of the spin-2 graviton excitations predicted by the Randall-Sundrum model with one warped extra dimension, in dilepton and diphoton production at LHC. By using a specific angular analysis, we assess the ranges in mass and coupling constant where such gravitons can be discriminated against competitor spin-1 and spin-0 objects, that potentially could manifest themselves in these processes with the same mass and rate of events. Depending on the value of the coupling constant to quarks and leptons, the numerical results indicate graviton identification mass ranges up to 1.1-2.4 TeV and 1.6-3.2 TeV for LHC nominal energy of 14 TeV and time-integrated luminosity of 10 and 100fb{sup -1}, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stimulated backward Brillouin scattering in two ion-species plasmas

Stimulated Brillouin back-scattering in mixed carbon and hydrogen plasmas is studied using one-dimensional Vlasov-Maxwell simulation. It is found that both the fast and slow ion acoustic waves can scatter the incident light. Carbon ions can be trapped in the slow ion acoustic wave, and the hydrogen ions can be trapped in both the fast and slow waves. The trapped ions tend to reduce the Landau damping of the ion acoustic waves, and both the fast and slow ion acoustic waves can be excited. From the time-integrated scattering spectra, the scattering peaks of the fast and slow ion acoustic waves can be clearly distinguished.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Laser Wavelength and Fluence in Pulsed Laser Deposition of Ge Films

Nanosecond lasers with ultra-violet, visible and infrared wavelengths: KrF (248 nm, 25 ns) and Nd:YAG (1064 nm, 532 nm, 355 nm, 5 ns) were used to ablate polycrystalline Ge target and deposit Ge films in vacuum (<10-6 Torr). Time-integrated optical emission spectra were obtained for laser fluence from 0.5-10 J/cm{sup 2}. Neutrals and ionized Ge species in the plasma plume were detected by optical emission spectroscopy. Ge neutrals dominated the plasma plume at low laser fluence while Ge{sup +} ions above some threshold fluence. The deposited amorphous thin-film samples consisted of particulates of size from nano to micron. The relation of the film properties and plume species at different laser fluence and wavelengths were discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of x-ray radiant characteristics and thermal radiation redistribution in CH foam filling cylindrical cavities

Experiments are presented, which demonstrate the properties of x-ray radiation and redistribution of radiant thermal energy in high Z cylindrical cavities filled with low Z CH foam. Time integrated spectra records were obtained by a calibrated space-resolved transmission grating spectrometer. The x-ray radiation became weaker in intensity and was changed to a softer near-Planckian radiation light after a 1500 {mu}m long transport in the foam filling cavity. The experimental redistribution of the radiant thermal energy was plotted and compared to the numerical results of a simplified model. Good agreements have been achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗