Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Certification of RadICS FPGA-based platform under US NRC requirements - 386

The paper discusses approach, applicable to certify digital instrumentation and control (I and C) platform under US Nuclear Regulatory Commission (NRC) requirements. Currently, Radics LLC is certifying its Field-Programmable Gate Array (FPGA)-based RadICS Platform using Platform-based test specimen. The Platform has been recently certified under IEC 61508 to meet Safety Integrity Level (SIL) 3 requirements. Up to now Radics LLC has developed a number of FPGA-based I and C applications based on RadICS Platform. Those applications include applications based on customer's specification and reverse engineering applications (Fit, Form and Function reproduction of existing equipment). The life cycles of applications include independent verification and validation of FPGA-based I and C systems/components, Commercial Grade Dedication of components for FPGA-based I and C systems, turnkey implementation of I and C project, supply of hardware, engineering tools and application design process. The paper also describes in details certification approach, which is based on Digital I and C-ISG- 06 and includes the following stages: general agreement with the US NRC, Topical Report submittal, timely responses and successful audits, and timely issuance of approved Topical Report. Such approach is supported by 10 CFR 50 Appendix B Quality Management System, which is also discussed in the paper. In addition, an overview of RadICS Platform Topical Report is presented, including its overview and structure, certification scope and obligatory appendixes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-630: Commissioning for SRS Planning Systems

Purpose: This study will try to find optimal procedures to collect small fields beam data for commissioning in treatment planning systems (TPS), and to provide a protocol to collect output factors for very small field sizes: 0.5 cm × 0.5 cm to 4.0 cm × 4.0 cm.This will help in determining the correct beam configuration methods in TPS planning intensity modulated radiation therapy (IMRT), and stereotactic radiosurgery SRS using mini multileaf collimation (mMLC). Methods: Data has been collected for a mMLC linear accelerator (linac) Novalis from 0.5 cm × 0.5 cm to 10 cm × 10 cm (its maximum field size). The TPS chosen is BrainLab, Eclipse and Cyberknife. The beam data collected was modeled and imported in the TPS. Verification plans were generated in solid water to confirm the goodness of the data. 3D and IMRT plans on regular CT scans were generated and verified using Mapcheck. All 3D plans with field sizes above 4 cm × 4 cm verified excellent using a distance to agreement of 2 mm and a 2% tolerance. IMRT plans gave an error of -8%. New scans with new detectors have been taken, new field sizes were introduced, and focus has been applied on determining the dosimetric leaf gap. Results: Although this is still a work in progress, this study brings several issues to light: the importance of the correct technique in beam data collection from the correct watertank to the correct detectors. Readings for rectangular fields have to be taken especially for fields which one side is under 4 cm. Conclusion: The use of equivalent square fields will not provide correct readings for the fields with large differences between the length and the width.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation dose delivery verification in the treatment of carcinoma-cervix

The accurate dose delivery to the clinical target volume in radiotherapy can be affected by various pelvic tissues heterogeneities. An in-house heterogeneous woman pelvic phantom was designed and used to verify the consistency and computational capability of treatment planning system of radiation dose delivery in the treatment of cancer cervix. Oncentra 3D-TPS with collapsed cone convolution (CCC) dose calculation algorithm was used to generate AP/PA and box field technique plan. the radiation dose was delivered by Primus Linac (Siemens make) employing high energy 15 MV photon beam by isocenter technique. A PTW make, 0.125cc ionization chamber was used for direct measurements at various reference points in cervix, bladder and rectum. The study revealed that maximum variation between computed and measured dose at cervix reference point was 1% in both the techniques and 3% and 4% variation in AP/PA field and 5% and 4.5% in box technique at bladder and rectum points respectively.

60 APPLIED LIFE SCIENCES↗

Tuning and Verification of an Internal Flooding Model for Dynamic PRA

In probabilistic risk assessment (PRA), the likelihoods and consequences of basic events are combined to determine possible system level outcomes and the likelihood of each outcome given an initial event. Both the consequences and likelihoods of basic events may be informed by the use of mathematical models or experimental data regarding the phenomena of interest. In either case, the impact of uncertainties on the results need to be evaluated. If a model is used to predict the evolution of an initiating event, uncertainty quantification can be computationally challenging for complex phenomena with many epistemic (e.g., model) uncertainties. In this work, a reduced order model is introduced for the flooding analysis of a multi-room building at a nuclear power plant under uncertainties which can require long run times using high fidelity computer models. The reduced order model focuses on macro-level transfer of water between rooms and tracks the water level within each room. In order to verify the model's fidelity, its results for the phenomena involved in a scenario of interest are compared to those of a computational fluid dynamics (CFD) code, which are taken to represent reality. This work does not focus on the overall fidelity of the flooding model, as the goal of the project for which it was developed is to develop a methodology rather than to analyze a particular case. The focus instead is on the tunability and verifiability of the reduced order model for relevant physical measures. In analyzing a particular case, the model may be required to incorporate more realistic description of phenomena; however, the procedure described in this work may be used to verify its performance as well. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A numerical study on bow shocks around the lightning return stroke channel

Bow shock structures are important to various hydrodynamics and magnetohydrodynamics (MHD) phenomena in geophysics and astrophysics. The formation and propagation of bow shocks around the lightning return stroke channel are investigated based on the self-similar motion theory and simulated with a two-dimensional Eulerian finite volume resistive radiation MHD code. In this framework, as verification of theoretical models, the evolving structures of many quantities, such as the plasma density, temperature, pressure, shock velocity, and magnetic field, can be obtained, which present all the characteristics of bow shocks in the lightning return stroke processes. The evolution characteristics and the configuration of the curved return stroke channels, e.g., the non-ideal effects and the scaling laws, are discussed in detail. The results may have applications for some observed features of the return stroke channels and other phenomena in the lightning discharge plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI

Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21CA165384-01A1.

60 APPLIED LIFE SCIENCES↗

Radiocarbon as a Reactive Tracer for Tracking Permanent CO 2 Storage in Basaltic Rocks

In view of concerns about the long-term integrity and containment of CO 2 storage in geologic reservoirs, many efforts have been made to improve the monitoring, verification and accounting methods for geologically stored CO 2 . Our project aimed to demonstrate that carbon-14 ( 14 C) could be used as a reactive tracer to monitor geochemical reactions and evaluate the extent of mineral trapping of CO 2 in basaltic rocks. The capacity of a storage reservoir for mineral trapping of CO 2 is largely a function of host rock composition. Mineral carbonation involves combining CO 2 with divalent cations including Ca 2+ , Mg 2+ and Fe 2+ . The most abundant geological sources for these cations are basaltic rocks. Based on initial storage capacity estimates, we know that basalts have the necessary capacity to store million to billion tons of CO 2 via in situ mineral carbonation. However, little is known about CO2-fluid-rock reactions occurring in a basaltic storage reservoir during and post-CO 2 injection. None of the common monitoring and verification techniques have been able to provide a surveying tool for mineral trapping. The most direct method for quantitative monitoring and accounting involves the tagging of the injected CO 2 with 14C because 14C is not present in deep geologic reservoirs prior to injection. Accordingly, we conducted two CO 2 injection tests at the CarbFix pilot injection site in Iceland to study the feasibility of 14C as a reactive tracer for monitoring CO 2 -fluid-rock reactions and CO 2 mineralization. Our newly developed monitoring techniques, using 14C as a reactive tracer, have been successfully demonstrated. For the first time, permanent and safe disposal of CO 2 as environmentally benign carbonate minerals in basaltic rocks could be shown. Over 95% of the injected CO 2 at the CarbFix pilot injection site was mineralized to carbonate minerals in less than two years after injection. Our monitoring results confirm that CO 2 mineralization in basaltic rocks is far faster than previously postulated.

01 COAL, LIGNITE, AND PEAT↗

Fibulin-4 is a novel Wnt/β-Catenin pathway activator in human osteosarcoma

Fibulin-4, an extracellular glycoprotein implicated in connective tissue development and elastic fiber formation, draws increasing focuses in cancer research. However, little is known about the underlying oncogenic roles of Fibulin-4 in human osteosarcoma (OS). In this study, by immunohistochemical analysis, upregulated expression of Fibulin-4 was found in the OS clinical specimens and cell lines compared to their normal counterparts. Fibulin-4 was positively correlated with the T stage of OS patients, and the proliferation index Ki67. Based on informatics analysis and functional verification, microRNA-137 was identified as a potential upstream regulator of Fibulin-4. Knockdown of Fibulin-4 or introduction of microRNA-137 inhibited cell proliferation and promoted cell apoptosis, and adverse effects were observed by overexpression of Fibulin-4. Furthermore, the tumor-suppressive functions of microRNA-137 were markedly abolished by restoration of Fibulin-4 expression in OS cells. Mechanistically, Fibulin-4 activated Wnt/β-Catenin pathway and promoted the expression of its downstream targets, including CCND2, c-Myc and VEGF. Taken together, Fibulin-4 plays critical neoplastic roles in tumor growth of human OS by activating Wnt/β-Catenin signaling and may represent a potential therapeutic target. -- Highlights: •Upregulated Fibulin-4 correlates tumor growth in human OS. •MicroRNA-137 is a critical regulator of Fibulin-4 expression. •Deregulated miR-137/Fibulin-4 axis promotes tumor growth of human OS. •Wnt/β-Catenin pathway is activated by Fibulin-4 stimulation.

60 APPLIED LIFE SCIENCES↗

Complete genome sequence and the expression pattern of plasmids of the model ethanologen Zymomonas mobilis ZM4 and its xylose-utilizing derivatives 8b and 2032

Zymomonas mobilis is a natural ethanologen being developed and deployed as an industrial biofuel producer. To date, eight Z. mobilis strains have been completely sequenced and found to contain 2-8 native plasmids. However, systematic verification of predicted Z. mobilis plasmid genes and their contribution to cell fitness has not been hitherto addressed. Moreover, the precise number and identities of plasmids in Z. mobilis model strain ZM4 have been unclear. The lack of functional information about plasmid genes in ZM4 impedes ongoing studies for this model biofuel-producing strain. In this study, we determined the complete chromosome and plasmid sequences of ZM4 and its engineered xylose-utilizing derivatives 2032 and 8b. Compared to previously published and revised ZM4 chromosome sequences, the ZM4 chromosome sequence reported here contains 65 nucleotide sequence variations as well as a 2400-bp insertion. Four plasmids were identified in all three strains, with 150 plasmid genes predicted in strain ZM4 and 2032, and 153 plasmid genes predicted in strain 8b due to the insertion of heterologous DNA for expanded substrate utilization. Plasmid genes were then annotated using Blast2GO, InterProScan, and systems biology data analyses, and most genes were found to have apparent orthologs in other organisms or identifiable conserved domains. To verify plasmid gene prediction, RNA-Seq was used to map transcripts and also compare relative gene expression under various growth conditions, including anaerobic and aerobic conditions, or growth in different concentrations of biomass hydrolysates. Overall, plasmid genes were more responsive to varying hydrolysate concentrations than to oxygen availability. Additionally, our results indicated that although all plasmids were present in low copy number (about 1-2 per cell), the copy number of some plasmids varied under specific growth conditions or due to heterologous gene insertion. The complete genome of ZM4 and two xylose-utilizing derivatives is reported in this study, with an emphasis on identifying and characterizing plasmid genes. Furthermore, plasmid gene annotation, validation, expression levels at growth conditions of interest, and contribution to host fitness are reported for the first time.

09 BIOMASS FUELS↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗

Pebble bed modular reactor safeguards: developing new approaches and implementing safeguards by design

The design of the Pebble Bed Modular Reactor (PBMR) does not fit or seem appropriate to the IAEA safeguards approach under the categories of light water reactor (LWR), on-load refueled reactor (OLR, i.e. CANDU), or Other (prismatic HTGR) because the fuel is in a bulk form, rather than discrete items. Because the nuclear fuel is a collection of nuclear material inserted in tennis-ball sized spheres containing structural and moderating material and a PBMR core will contain a bulk load on the order of 500,000 spheres, it could be classified as a 'Bulk-Fuel Reactor.' Hence, the IAEA should develop unique safeguards criteria. In a multi-lab DOE study, it was found that an optimized blend of: (i) developing techniques to verify the plutonium content in spent fuel pebbles, (ii) improving burn-up computer codes for PBMR spent fuel to provide better understanding of the core and spent fuel makeup, and (iii) utilizing bulk verification techniques for PBMR spent fuel storage bins should be combined with the historic IAEA and South African approaches of containment and surveillance to verify and maintain continuity of knowledge of PBMR fuel. For all of these techniques to work the design of the reactor will need to accommodate safeguards and material accountancy measures to a far greater extent than has thus far been the case. The implementation of Safeguards-by-Design as the PBMR design progresses provides an approach to meets these safeguards and accountancy needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Systematic Literature Review: How is Model-Based Systems Engineering Justified?

The genesis for this systematic literature review was to search for industry case studies that could inform a decision of whether or not to support the change process, investment, training, and tools needed to implement an MBSE approach across the engineering enterprise. The question asked was, how the change from a document - based systems engineering approach (DBSE) to a model-based systems engineering approach (MBSE) is justified? The methodology employed for this systematic literature review was to conduct a document search of electronically published case studies by authors from the defense, space, and complex systems product engineering industries. The 67 case studies without metrics mainly attributed success to completeness, consistency, and communication of requirements. The 21 case studies with metrics on cost and schedule primarily attributed success to the ability of an MBSE approach to improve defect prevention strategies. The primary conclusion is that there is a significant advantage to project performance by applying an MBSE approach. An MBSE approach made the engineering processes on a complex system development effort more efficient by improving requirements completeness, consistency, and communication. These were seen in engineering processes involved in requirements management, concept exploration, design reuse, test and qualification, Verification and Validation, and margins analyses. An MBSE approach was most effective at improving defect prevention strategies. The approach was found to enhance the capability to find defects early in the system development life cycle (SDLC), when they could be fixed with less impact and prevented rework in later phases, thus mitigating risks to cost, schedule, and mission. However, if a program only employed an MBSE approach for requirements management, advantages from finding defects early could not be leveraged in later phases, where the savings in cost and schedule from rework prevention is realized. Significant performance success was achieved when the systems engineer (SE) held a leadership role over engineering process es. A number of the case studies addressed a general lack of skilled MBSE engineers as a major hindrance to implementing an MBSE approach successfully.

42 ENGINEERING↗

A review of human-system interface design issues observed during analog-to-digital and digital-to-digital migrations in U.S. nuclear power plants - 312

The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is developing a scientific basis through targeted research and development (R and D) to support the U.S. nuclear power plant (NPP) fleet in extending their existing licensing period and ensuring their long-term reliability, productivity, safety, and security. Over the last several years, human factors engineering (HFE) professionals at the Idaho National Laboratory (INL) have supported the LWRS Advanced Instrumentation, Information, and Control (II and C) System Technologies pathway across several U.S. commercial NPPs in analog-to-digital migrations (i.e., turbine control systems) and digital-to-digital migrations (i.e., Safety Parameter Display System). These efforts have included in-depth human factors evaluation of proposed human-system interface (HSI) design concepts against established U.S. Nuclear Regulatory Commission (NRC) design guidelines from NUREG-0700, Rev 2 to inform subsequent HSI design prior to transitioning into Verification and Validation. This paper discusses some of the overarching design issues observed from these past HFE evaluations. In addition, this work presents some observed challenges such as common tradeoffs utilities are likely to face when introducing new HSI technologies into NPP hybrid control rooms. The primary purpose of this work is to distill these observed design issues into general HSI design guidance that industry can use in early stages of HSI design. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prompt gamma timing range verification for scattered proton beams

Range verification is a very important point in order to fully exploit the physical advantages of protons compared to photons in cancer irradiation. Recently, a simple method has been proposed which makes use of the time of fight of protons in tissue and the promptly emitted secondary photons along the proton path (Prompt Gamma Timing, PGT). This has been considered so far for monoenergetic pencil beams only. In this work, it has been studied whether this technique can also be applied in passively formed irradiation fields with a so called spread out Bragg peak. Time correlated profiles could be recorded, which show a trend that is consistent with theoretical predictions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MOCUM Verification with a Heterogeneous MOX Whole Core C5G7 Benchmark Problem

Recent advancements in computer technology has allowed for the possibility to solve complex reactor problems without homogenization, but the present benchmark problems are all limited to small scale with few fuel assemblies and homogeneity at the core level. Therefore, to verify the capabilities of the advanced neutronics codes, heterogeneous full core model shall be developed. Recently several whole-core benchmark problems such as BEAVRS and VERA are developed with measured data to which computational codes can be compared. With a particular research interest on the MOX fuel, this study develops a two-dimensional (2-D) whole core MOX neutronics benchmark based on the C5G7 benchmark concept. The developed MOX core benchmark will then be used to verify the accuracy of the MOCUM code, which is developed using the method of characteristic (MOC) as the flux solver with an advanced geometry processor designed for arbitrary core geometries. MOCUM results will be compared against MCNP5 results as the reference solutions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of the shift Monte Carlo code with the C5G7 reactor benchmark

Shift is a new hybrid Monte Carlo/deterministic radiation transport code being developed at Oak Ridge National Laboratory. At its current stage of development, Shift includes a parallel Monte Carlo capability for simulating eigenvalue and fixed-source multigroup transport problems. This paper focuses on recent efforts to verify Shift's Monte Carlo component using the two-dimensional and three-dimensional C5G7 NEA benchmark problems. Comparisons were made between the benchmark eigenvalues and those output by the Shift code. In addition, mesh-based scalar flux tally results generated by Shift were compared to those obtained using MCNP5 on an identical model and tally grid. The Shift-generated eigenvalues were within three standard deviations of the benchmark and MCNP5-1.60 values in all cases. The flux tallies generated by Shift were found to be in very good agreement with those from MCNP. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Novel Physiologically Based Model of Creatinine Renal Disposition to Integrate Current Knowledge of Systems Parameters and Clinical Observations

Creatinine is the most common clinical biomarker of renal function. As a substrate for renal transporters, its secretion is susceptible to inhibition by drugs, resulting in transient increase in serum creatinine and false impression of damage to kidney. Novel physiologically based models for creatinine were developed here and (dis)qualified in a stepwise manner until consistency with clinical data. Data from a matrix of studies were integrated, including systems data (common to all models), proteomics‐informed in vitro – in vivo extrapolation of all relevant transporter clearances, exogenous administration of creatinine (to estimate endogenous synthesis rate), and inhibition of different renal transporters (11 perpetrator drugs considered for qualification during creatinine model development and verification on independent data sets). The proteomics‐informed bottom‐up approach resulted in the underprediction of creatinine renal secretion. Subsequently, creatinine‐trimethoprim clinical data were used to inform key model parameters in a reverse translation manner, highlighting best practices and challenges for middle‐out optimization of mechanistic models.

Scotcher, Daniel↗

Groundwater flow and heat transport for systems undergoing freeze-thaw: Intercomparison of numerical simulators for 2D test cases

In high-elevation, boreal and arctic regions, hydrological processes and associated water bodies can be strongly influenced by the distribution of permafrost. Recent field and modeling studies indicate that a fully-coupled multidimensional thermo-hydraulic approach is required to accurately model the evolution of these permafrost-impacted landscapes and groundwater systems. However, the relatively new and complex numerical codes being developed for coupled non-linear freeze-thaw systems require verification. Here in this paper, this issue is addressed by means of an intercomparison of thirteen numerical codes for two-dimensional test cases with several performance metrics (PMs). These codes comprise a wide range of numerical approaches, spatial and temporal discretization strategies, and computational efficiencies. Results suggest that the codes provide robust results for the test cases considered and that minor discrepancies are explained by computational precision. However, larger discrepancies are observed for some PMs resulting from differences in the governing equations, discretization issues, or in the freezing curve used by some codes.

54 ENVIRONMENTAL SCIENCES↗