Advanced In-Furnace NO x Control for Wall and Cyclone-Fired Boilers

A NO x minimization strategy for coal-burning wall-fired and cyclone boilers was developed that included deep air staging, innovative oxygen use, reburning, and advanced combustion control enhancements. Computational fluid dynamics modeling was applied to refine and select the best arrangements. Pilot-scale tests were conducted by firing an eastern high-volatile bituminous Pittsburgh No.8 coal at 5 million Btu/hr in a facility that was set up with two-level overfire air (OFA) ports. In the wall-fired mode, pulverized coal was burned in a geometrically scaled down version of the B and W DRB-4Z® low-NO x burner. At a fixed overall excess air level of 17%, NO x emissions with single-level OFA ports were around 0.32 lb/million Btu at 0.80 burner stoichiometry. Two-level OFA operation lowered the NO x levels to 0.25 lb/million Btu. Oxygen enrichment in the staged burner reduced the NO x values to 0.21 lb/million Btu. Oxygen enrichment plus reburning and 2-level OFA operation further curbed the NO x emissions to 0.19 lb/million Btu or by 41% from conventional air-staged operation with single-level OFA ports. In the cyclone firing arrangement, oxygen enrichment of the cyclone combustor enabled high-temperature and deeply staged operation while maintaining good slag tapping. Firing the Pittsburgh No.8 coal in the optimum arrangement generated 112 ppmv NO x (0.15 lb/million Btu) and 59 ppmv CO. The optimum emissions results represent 88% NO x reduction from the uncontrolled operation. Levelized costs for additional NO x removal by various in-furnace control methods in reference wall-fired or cyclone-fired units already equipped with single-level OFA ports were estimated and compared with figures for SCR systems achieving 0.1 lb NO x /10 6 Btu. Two-level OFA ports could offer the most economical approach for moderate NO x control, especially for smaller units. O 2 enrichment in combination with 2-level OFA was not cost effective for wall-firing. For cyclone units, NO x removal by two-level OFA plus O 2 enrichment but without coal reburning was economically attractive.

01 COAL, LIGNITE, AND PEAT↗

Analysis Of 2h-Evaporator Scale Wall [HTF-13-82] And Pot Bottom [HTF-13-77] Samples

Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material has been performed so that uranium and plutonium isotopic analysis can be input into a Nuclear Criticality Safety Assessment (NCSA) for scale removal by chemical cleaning. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2Hevaporator pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from the bottom cone sections of the 2H-evaporator pot [Sample HTF-13-77] and the wall 2H-evaporator [sample HTF-13-82]. X-ray diffraction analysis (XRD) confirmed that both the 2H-evaporator pot scale and the wall samples consist of nitrated cancrinite (a crystalline sodium aluminosilicate solid) and clarkeite (a uranium oxy-hydroxide mineral). On “as received” basis, the bottom pot section scale sample contained an average of 2.59E+00 ± 1.40E-01 wt % total uranium with a U-235 enrichment of 6.12E-01 ± 1.48E-02 %, while the wall sample contained an average of 4.03E+00 ± 9.79E-01 wt % total uranium with a U-235 enrichment of 6.03E-01% ± 1.66E-02 wt %. The bottom pot section scale sample analyses results for Pu-238, Pu-239, and Pu-241 are 3.16E- 05 ± 5.40E-06 wt %, 3.28E-04 ± 1.45E-05 wt %, and <8.80E-07 wt %, respectively. The evaporator wall scale samples analysis values for Pu-238, Pu-239, and Pu-241 averages 3.74E-05 ± 6.01E-06 wt %, 4.38E-04 ± 5.08E-05 wt %, and <1.38E-06 wt %, respectively. The Pu-241 analyses results, as presented, are upper limit values. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241. The applicable method for calculation of equivalent U-235 will be determined in the NCSA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Performance Evaluation of Walls with Gas Filled Panel Insulation

Gas filled insulation panels (GFP) are very light weight and compact (when uninflated) advanced insulation products. GFPs consist of multiple layers of thin, low emittance (low-e) metalized aluminum. When expanded, the internal, low-e aluminum layers form a honeycomb structure. These baffled polymer chambers are enveloped by a sealed barrier and filled with either air or a low-conductivity gas. The sealed exterior aluminum foil barrier films provide thermal resistance, flammability protection, and properties to contain air or a low conductivity inert gas. This product was initially developed with a grant from the U.S. Department of Energy. The unexpanded product is nearly flat for easy storage and transport. Therefore, transportation volume and weight of the GFP to fill unit volume of wall cavity is much smaller compared to that of other conventional insulation products. This feature makes this product appealing to use at Army Contingency Basing, when transportation cost is significant compared to the cost of materials. The objective of this study is to evaluate thermal performance of walls, similar to those used at typical Barracks Hut (B-Hut) hard shelters, when GFPs are used in the wall cavities. Oak Ridge National Laboratory (ORNL) tested performance of the wall in the rotatable guarded hotbox (RGHB) according to the ASTM C 1363 standard test method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Durability Assessment of Selected Well-insulated Wall Assemblies

This report presents the results from studying the hygrothermal performance of two well-insulated wall assemblies, both complying with and exceeding international building codes (IECC 2015 2014, IRC 2015). The hygrothermal performance of walls is affected by a large number of influential parameters (e.g., outdoor and indoor climates, workmanship, material properties). This study was based on a probabilistic risk assessment in which a number of these influential parameters were simulated with their natural variability. The purpose of this approach was to generate simulation results based on laboratory chamber measurements that represent a variety of performances and thus better mimic realistic conditions. In total, laboratory measurements and 6,000 simulations were completed for five different US climate zones. A mold growth indicator (MGI) was used to estimate the risk of mold which potentially can cause moisture durability problems in the selected wall assemblies. Analyzing the possible impact on the indoor climate due to mold was not part of this study. The following conclusions can be reached from analyzing the simulation results. In a hot-humid climate, a higher R-value increases the importance of the airtightness because interior wall materials are at lower temperatures. In a cold climate, indoor humidity levels increase with increased airtightness. Air leakage must be considered in a hygrothermal risk assessment, since air efficiently brings moisture into buildings from either the interior or exterior environment. The sensitivity analysis of this study identifies mitigation strategies. Again, it is important to remark that MGI is an indicator of mold, not an indicator of indoor air quality and that mold is the most conservative indicator for moisture durability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approximate Augmentation of Turbulent Law-of-the-Wall by Periodic Free-Stream Disturbances

We examine the role of periodic sinusoidal free-stream disturbances on the inner law law-of-the-wall (log-law) for turbulent boundary layers. This model serves a surrogate for the interaction of flight vehicles with atmospheric disturbances. The approximate skin friction expression that is derived suggests that free-stream disturbances can cause enhancement of the mean skin friction. Considering the influence of grid generated free stream turbulence in the laminar sublayer/log law region (small scale/high frequency) the model recovers the well-known shear layer enhancement suggesting an overall validity for the approach. The effect on the wall shear associated with the lower frequency due to the passage of the vehicle through large (vehicle scale) atmospheric disturbances is likely small i.e. on the order 1% increase for turbulence intensities on the order of 2%. The increase in wall pressure fluctuation which is directly proportional to the wall shear stress is correspondingly small.

42 ENGINEERING↗

Dissecting the functional significance of non-catalytic carbohydrate binding modules in the deconstruction of plant cell walls

The project seeks to investigate the mechanism by which CBMs potentiate the activity of glycoside hydrolases against complete plant cell walls. The project is based on the hypothesis that the wide range of CBMs present in bacterial enzymes maximize the potential target substrates by directing the cognate enzymes not only to different regions of a specific plant cell wall, but also increases the range of plant cell walls that can be degraded. In addition to maximizing substrate access, it was also proposed that CBMs can target specific subsets of hydrolases with complementary activities to the same region of the plant cell wall, thereby maximizing the synergistic interactions between these enzymes. This synergy is based on the premise that the hydrolysis of a specific polysaccharide will increase the access of closely associated polymers to enzyme attack. In addition, it is unclear whether the catalytic module and appended CBM of modular enzymes have evolved unique complementary activities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A status review on DNB prediction using CASL baseline boiling model and possible suggestions regarding wall boiling closures

The main goal of FY18 THM’s focus task is to evaluate where the current CASL boiling model stands for DNB predictive performance, to identify which components should be improved or calibrated to enhance DNB performance. Over the past three year’s validation tests, Gen1A boiling model has presented an under-predictive behavior for DNB at the high pressure of interest for PWR application. With this in mind, this year’s task is to focus on 1) best practice guidelines on DNB detection criteria, 2) interfacial momentum transfer closure tests, and 3) wall boiling closure sensitivity on DNB. Best practice guidelines on DNB detection criteria are demonstrated by the following three monitoring variables: 1) max wall temperature, 2) K-value and 3) energy balance. Interfacial momentum transfer closure govern the bubble distribution, especially in lateral direction, as well as bubble mean diameter. A clear correlation between interfacial momentum closure and DNB prediction is not observed in the current tests. However, void distributions are changed with different interfacial momentum closure tests which requires further validation with corresponding experimental measurement. From a variety of wall boiling closure tests, bubble departure diameter seems the most sensitive for DNB performance while fulfilling numerical robustness in DNB simulation. Tolubinski’s bubble departure diameter model was calibrated to see if any improvement is observed in DNB performance. Notable DNB improvement was observed as the bubble departure diameter is reduced. However, reduced bubble departure diameter by calibrated Tolubinski’s model seemed to lead to relatively high wall superheat temperature prediction which requires further validation with associated experimental measurement It should be noted that lack of experimental measurement close to DNB condition hampers this boiling closure sensitivity study significantly. This situation directly reflects some of limitations of the CASL boiling model development. With this in mind, the implementation of improved boiling closure on 5x5 NMVG and MVG tests will be pursued in FY19, the associated DNB best practice guidelines and possible limitations will be addressed for industry DNB application.

42 ENGINEERING↗

In situ scanning probe microscopy studies of cross-coupled domains and domain walls. Final technical report

The objective of this project is to explore the nanoscale emergent phenomena and to understand the unconventional properties of cross-coupled domains and domain walls in multiferroics, where both ferroelectricity and magnetism coexist. The giant magnetoelectric effect due to coupled ferroic orders in multiferroics is of both fundamental and technological interest and is promising for energy-efficient multifunctional applications. The presence of domains and domain walls is a distinguishing feature of any ferroic order; their responses to external stimuli determine the macroscopic properties and the functionalities of ferroic materials. To address the challenges and to directly visualize the cross-coupled domains and domain walls and their responses to the applied electric and magnetic fields, this project will develop a unique, high-resolution and high-sensitivity in situ scanning force microscopy (SFM). The real space imaging of domains and domain walls by SFM aims to fundamentally understand the nature of magnetoelectric cross-coupling in representative multiferroic and magnetoelectric materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗

High-Temperature Tensile and Creep Test Results on Thin Wall Tube Specimens of ODS Alloys 14YWT and OFRAC

High-temperature tensile and strain rate jump (SRJ) creep tests were conducted on axial specimens fabricated from thin wall tubes of the oxide dispersion strengthened (ODS) alloys 14YWT and OFRAC. The dimensions of the 14YWT thin wall tube was 10.7 mm OD, 0.5 mm WT and 0.92 m and of the OFRAC thin wall tube was 8.5 mm OD + 0.5 mm WT and 1.78 m in length. The axial specimens fabricated from the thin wall tubes were based on a dual-gauge design with gauge dimensions of 4 mm long and 2 mm wide. The tensile tests were conducted in air at 800ºC, 900ºC and 1,000ºC and the SRJ creep tests were conducted in air at 800ºC. Two axial specimens were used in each tensile and SRJ creep tests. The results of the tensile tests showed much lower yield stress (YS) compared to ultimate tensile strength (UTS) indicative of large work hardening properties. The results showed the UTS of OFRAC was higher than that of 14YWT by ~35 MPa at 800ºC. At 900ºC, the UTS of OFRAC and 14YWT was similar at 900ºC and at 1000ºC, the UTS of 14YWT was higher than that of OFRAC by ~10 MPa. The ductility properties of OFRAC were greater than that of 14YWT with higher values of uniform elongation (UE) and total elongation (TE) at all tensile test temperatures. The creep properties of 14YWT and OFRAC were evaluated by the strain rate jump test method at 800ºC. The stress exponent (n) for creep was obtained from the SRJ test data by plotting the values of the log strain rate against the log stress, which is measured from the stress-strain curve generated during the SRJ test. The results showed the highest stress exponents of n = 19.8 and n = 35.0 were measured from the two SRJ tests on 14YWT. The stress exponent measured from one successful SRJ test on OFRAC was n = 13.3, which was lower than that of 14YWT. Nevertheless, these high values of stress exponent are consistent with ODS ferritic alloys such as 14YWT and OFRAC since they indicate dislocation-particle interactions are the dominant creep mechanism for specific ranges of temperature and stress. The results obtained from the tensile and SRJ creep tests conducted on axial specimens in this study indicate that 14YWT and OFRAC retain high strengths at temperatures up to 1,000ºC and good creep performance at 800ºC.

36 MATERIALS SCIENCE↗

Wall Upgrades for Energy Retrofits: A Techno-Economic Study

Homes built before 1992, when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of the residential building stock in the country. Up to 43% of these homes have little to no insulation in the walls and have very high air leakage rates of 10 or more air changes per hour at 50 pascals of pressure (ACH50). These issues can represent a substantial portion of unnecessary money spent on utility bills for homeowners, especially in the colder climates. There is a significant need for cost-effective, reliable retrofit methods for these homes that include air, moisture, and vapor controls which are considered best practices for high-performance new home construction. Well-tested and documented wall retrofit systems can help to achieve substantial energy savings and also improve durability, comfort, health, and resilience. In 2018, DOE’s Building Technologies Office awarded Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota funding to complete a 3-year project to compare a range of residential wall retrofit systems that prioritized affordability, durability and energy savings potential. In addition to these core criteria, the ease-of-construction and the wide-scale applicability of the solutions also were considered. In this project, the research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updates to Nek5000: RANS wall functions, NRC support, and documentation

As a key part of the U.S. Department of Energy’s Nuclear Energy Advanced Modeling and Simulation program (NEAMS), the next generation of tools for nuclear reactor design are being developed. A primary metric for success of this program is the adoption of those tools by industry stakeholders. To help meet this metric for Nek5000, development efforts this year have focused on the expansion of the available Reynolds-averaged Navier-Stokes (RANS) turbulence models to include wall function models, continued support of the U.S. Nuclear Regulatory Commission in simulating a hydrogen mitigation benchmark experiment, and expansion of the Nek5000 documentation to enhance the code’s usability. The implementation of wall functions is intended to significantly decrease time to-solution for a wide range of problems and it has been identified as an important feature by stakeholders across the nuclear community. The initial implementation of standard and pressure corrected wall functions has been tested in Nek5000 on the classical problems of channel flow and a backward facing step. It has also been tested on a 2D molten salt fast reactor core and a T-junction. The recommended formulation of choosing y + = 30 as a boundary value combined with a Neumann-Neumann formulation of the boundary condition for k and τ produces the most consistent results compared to a wall resolved approach. The collaboration with the NRC is a continuing exercise that has been ongoing for multiple years. This year we have concluded investigations into appropriate inlet conditions, showing that fully developed turbulent conditions are adequate for the full PANDA domain. We have also concluded simulations for an unobstructed jet and are now refocusing to the original obstructed jet case. The expansion of the code documentation has also been an ongoing effort over the past few years to address feedback from the various stakeholders. The documentation now more fully covers many of the available features and closes identified SQA gaps. Finally we report on three training sessions that were offered over the past year in an effort to expand the Nek5000 user base.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. This report, Performance of Windows in Walls with Continuous Insulation , explores the common method for installing windows in walls with continuous insulation and presents acceptance criteria for evaluating the performance of windows installed in walls with and without continuous insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Evaluation of flame propagation of retrofit energy efficient wall assemblies

Leveraging safety science experience and industry relationships, UL Solutions and the International Association of Fire Fighters (IAFF) initiated a joint project in 2022 under an agreement with the US Department of Energy to evaluate the flame propagation of retrofit energy efficient wall assemblies. A draft of the protocol from the ASTM work was used to test and comparatively study various retrofit energy efficient designs to gain a better understanding of their fire behavior. The goals of this study were as follows: Develop an understanding of fire propagation across new, cost effective, and energy efficient exterior retrofit wall assemblies. Refine the flame propagation draft test method for exterior wall assemblies based on ASTM E2707. Identify conditions that create fire propagation hazards in exterior wall assemblies and educate the fire service on the findings.

42 ENGINEERING↗

Impact of particle size and particle-flow-wall coupling on pressurized oxy-combustion in the down-fired burner

Concerns over climate change have led to numerous efforts in developing low-carbon energy technologies. Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Designing an effective burner plays a vital role in developing new coal combustion technologies. Because of the high pressure, the volume fraction of coal particles at the fuel inlet of the burner of a pressurized oxy-combustor is close or even higher than the maximum limit that commercial CFD codes (e.g., ANSYS FLUENT) can handle. At this high particle volume fraction, the interactions among particles, fluid flow, and wall need to be re-evaluated. The present computational work is the first step of a systematic analysis of the particle influence, like releasing method, releasing locating, and particle size, in a pilot-scale POC combustor, developed at Washington University in St. Louis (WUSTL). In a POC process, pulverized coal is burned under elevated pressure and O2-CO2 environment. Specifically, a 15-bar, 100 kWth, POC combustor is modeled employing ANSYS FLUENT, using Reynolds-averaged Navier-Stokes (RANS) modeling. It is revealed that for this pilot-scale, pressurized burner, velocity profiles of the near-wall region in this POC facility exhibit some discrepancy against the near-wall turbulent flow velocity profile. In order to investigate the particle influence in the near-wall region, particle releasing location will be investigated. Numerical simulation results exhibit the coupling effect of turbulence flow and particles in this case. The particle size also demonstrates a great effect on particle trajectory, then further has an impact on flame stability and temperature.