Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP Report 147 is still sufficient for the Hologic DBT system given the workload from a previous survey at MGH. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improvement of the optical image reconstruction based on multiplexed quantum ghost images

Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward Measuring Prompt Fission Products in Coincidence

Despite the discovery of fission nearly 80 years ago and its importance to nuclear energy, national security, and astrophysics, there are very few measurements of the correlations between multiple fission products. An experiment is underway at Oak Ridge National Laboratory to measure the energy and angle correlations between prompt fission neutrons, γ rays, and fragments. These measurements could reveal the existence of scission neutrons, the energy balance between these products, and other details needed for benchmarking advanced fission models. The setup includes an array of VANDLE neutron detectors and a γ-ray detector positioned opposite a suite of detectors to determine the mass of one fragment. Preliminary results with a spontaneous 252Cf source show expected correlations between prompt fragments and neutrons along the fission axis. Further refinements will improve the resolution of the fragment mass and increase efficiency for triple-coincident events. Future experiments could be done with a neutron beam to study induced fission on thin targets.

Peters, William A.↗

GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of open and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results from the Cuore Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO 2 crystals arranged in a cylindrical compact structure of 19 towers, each of them made of 52 crystals. Here, the construction of the experiment was completed in August 2016 and the data taking started in spring 2017 after a period of commissioning and tests. In this work we present the neutrinoless double beta decay results of CUORE from examining a total TeO 2 exposure of 86.3 kg yr , characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/(keV kg yr) . In this physics run, CUORE placed a lower limit on the decay half-life of neutrinoless double beta decay of 130 Te > 1.3 • 10 25 yr (90% C.L.). Moreover, an analysis of the background of the experiment is presented as well as the measurement of the 130 Te 2 νββ decay with a resulting half-life of T 2ν 1/2 = [7.9 ± 0.1(stat.) ± 0.2(syst.)] × 10 20 yr which is the most precise measurement of the half-life and compatible with previous results.

79 ASTRONOMY AND ASTROPHYSICS↗

A Unified Model of Cosmic-Ray Propagation and Radio Extreme Scattering Events from Intermittent Interstellar Structures

Intermittent magnetic structures are a plausible candidate for explaining cosmic-ray (CR) diffusion rates derived from observed CR energy spectra. Independently, studies of extreme scattering events (ESEs) of radio quasars and pulsar scintillation have hinted that very straight, large aspect ratio magnetic current sheets may be responsible for the localized large scattering of radio waves. The required shortest axis of the typical structures producing ESEs is of the same scale (∼au) as the gyroradii of ∼GeV CRs. In this Letter, we propose that the same magnetic/density sheets can produce large scattering of both CRs and radio waves. We demonstrate that the geometry and volume-filling factor of the sheets derived from quasar ESEs can explain the observed mean free path of GeV CRs without introducing free parameters. The model places constraints on the sheet geometry, such as straightness and large aspect ratio, and assumes that the statistics of the sheets are similar throughout the Galactic volume. We therefore discuss observational tests of the sheet model, which includes observations of echoes in pulsars and fast radio bursts, gravitationally lensed quasars, the distribution of ESE durations, and spatial correlations between ESE events and rotation measure fluctuations. Such tests will be enabled by upcoming wide-field radio instruments, including the Canadian Hydrogen Observatory and Radio-transient Detector and Deep Synoptic Array 2000 Antennas.

Kempski, Philipp [Princeton Univ., NJ (United Stat↗

MPACT FY2011 Advanced Time-Correlated Measurement Research at INL

Simulations and experiments have been carried out to investigate advanced time-correlated measurement methods for characterizing and assaying nuclear material for safeguarding the nuclear fuel cycle. These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control Technologies (MPACT) program. For fiscal year 2011 work focused on examining the practical experimental aspects of using a time-tagged, associated-particle electronic neutron generator for interrogating low-enrichment uranium in combination with steady-state interrogation using a moderated 241Am-Li neutron source. Simulation work for the project involved the use of the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and the time-of-flight energy spectra of different sample materials under irradiation. Work also took place to develop a post-processor parser code to extract comparable data from the MCNP5&6 codes. Experiments took place using a commercial deuterium-tritium associated-particle electronic neutron generator to irradiate a number of uranium-bearing material samples. Time-correlated measurements of neutron and photon signatures of these measurements were made using five liquid scintillator detectors in a novel array, using high-speed waveform digitizers for data collection. This report summarizes the experiments that took place in FY2011, presents preliminary analyses that have been carried out to date for a subpart of these experiments, and describes future activities planned in this area. The report also describes support Idaho National Laboratory gave to Oak Ridge National Laboratory in 2011 to facilitate 2-dimensional imagery of mixed-oxide fuel pins for safeguards applications as a part of the MPACT program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO 2 crystals, for a total mass of 742 kg. CUORE is presently in data taking, searching for the neutrinoless double beta decay of 130 Te. CUORE is operational since the spring of 2017. The initial science run already allowed to provide the most stringent limit on the neutrinoless double beta decay half-life of 130 Te, and to perform the most precise measurement of the two-neutrino double beta decay half-life. Up to date, we have more than doubled the collected exposure. In this talk, we presented the most recent results and discuss the present status of the CUORE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Spin Asymmetries of the Proton

The Spin Asymmetries of the Nucleon Experiment (SANE) measured the parallel, $A_\parallel$, and near-perpendicular, $A_{80}$, double spin asymmetries of the proton in inclusive electron scattering. Longitudinally polarized electrons were scattered from an ammonia target which provided polarized protons via dynamic nuclear polarization. The scattered electrons were detected using the Big Electron Telescope Array, BETA, which was centered at 40$^\circ$ and covered a large solid angle. BETA consisted of a scintillator hodoscope, gas Cherenkov, lucite hodoscope and a large array of lead glass detectors. The data was taken at the Thomas Jefferson National Accelerator Facility's Hall C at beam energies of $4.7$ and $5.9~GeV$ and covered $2.5~GeV^2 < Q^2 < 6.5~GeV^2$. From the $A_\parallel$ and $A_{80}$ measurements, the proton's spin asymmetries, $A_1$ and $A_2$, and the spin structure functions of the proton, $g_1$ and $g_2$, can be extracted. The measurements are in a range of Bjorken $x$, $0.3 < x < 0.8$, where extraction of the twist three matrix element $d_2^p $ (an integral of $g_1$ and $g_2$ weighted by $x^2$) is most sensitive.

Jones, Mark↗

Timing Resolution tests of Silicon Photomultipliers for use at the Jefferson Lab

Silicon Photomultipliers are currently under much scrutiny at the Jefferson Lab. Their small size, and ability to operate unshielded in strong magnetic fields make them ideal for use in particle accelerators. At the Jefferson Lab these SiPMs are slated for possible use in several detector systems in the new 12GeV upgrade. One such project is the Central Time of Flight (CTOF) detector in CLAS Hall B, whose goal is to identify and distinguish between particle species using Timing and Momentum calculations. The Photomultipliers in this detector will experience magnetic fields of up to 5 T and require timing resolutions of 50ps, the smallest of any detector in the lab. Currently this role is filled by Hammamatsu R2083 PMTs, which require robust magnetic shielding. Resolution tests were performed with directed LED light at various frequencies and intensities. The SiPMs were found to have a resolution of 76ps at usable surface areas, 50{\%} greater than the required maximum of 50ps for CTOF, but well below that necessary for other detector systems, such as the Central Neutron Detector and Photon Tagger arrays.

Reustle, Alexander↗

Measurement of elastic 12C+alpha scattering: details of the experiment, analysis, and discussion of phase shifts

Recent global analyses of {sup 12}C({alpha},{gamma}){sup 16}O have incorporated both elastic-scallering and {beta}-decay data in addition to direct measurements. In that context, it has been shown that an improvement in the available elastic-scallering data could help determine the contribution of the two subthreshold states, 6.92(2{sup +}) and 7.12(1{sup -}) MeV, and with excellent statistics could restrict resonance parameters above the threshold. To this end angular distributions of {sup 12}C({alpha}, {alpha}){sup 12}C in the {alpha}-energy range of 2.6-8.2 MeV, at angles from 24 to 166 have been measured at the University of Notre Dame using an array of 32 silicon detectors. Details of the experiment are reported. In the present analysis, the phase shifts have been determined from our previously reported R-matrix fit to these data. The uncertainties in the R-matrix phase shifts ({ell} = 0...6) are derived by a new Monte Carlo analysis technique as described in the article. We provide these phase shifts here for general use, in particular for the improved analysis and extrapolation of the {alpha} radiative capture to low energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Subspace Detectors to 2012 Sumatera Earthquake Sequence

In this report the aftershock sequence of the 2012 Sumatra earthquake is used to study the performance of subspace detectors (Harris, 2006) to detect and classify the events. The ground truth used for this study is 1222 aftershock solutions from the LLNL database drawn mostly from the Reviewed Event Bulletin (REB). Subspace detectors are built using several spawning strategies with waveforms recorded by the Makanchi Array (MKAR). Because we desire the subspace detectors to have a very low false alarm rate, the subspace templates are required to be about 50 seconds long (most of the P-bundle). For the same reason, the power detections used to create the subspace templates are restricted to have high SNR. Because of these restrictions, none of the subspace detectors are able to reproduce the entire ground truth catalog. They do have a very low false alarm rate, however, and so can reliably be used as single-array detection classifiers. Because of their reliability, in a suitably designed system, these detectors could be used to segregate detections from regions of high seismicity such as aftershock sequences, and allow processing of those detections in isolation from routine seismicity. It may also be possible to use these detectors to process groups of detections simultaneously. This leads to the concept of “analyst workload reduction factor”; a measure of the reduction in effort achieved by processing N detections in M groups instead of individually. If M is much smaller than N, a significant reduction factor is achieved.

58 GEOSCIENCES↗

Demonstration of the neutron tracking capability of NEXT array in time-of-flight measurements to improve energy resolution

Precise neutron-energy measurements are required to probe the nuclear structure effects of neutron-rich nuclei, where β-delayed neutron emission becomes a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) array has been designed and constructed to measure β-delayed neutrons with better energy resolution. The new design localizes the neutron interaction position by optically segmenting the detector along the direction of the neutron flight path, reducing the associated uncertainties in the neutron time-of-flight measurements. This significantly improves the energy resolution without losing the necessary detection efficiency. The proof-of-principle and efficiency measurements showed promising results. Herein, this article details the implementation of the neutron tracking capability of NEXT array in time-of-flight measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded FPGA developments in 130 nm and 28 nm CMOS for machine learning in particle detector readout

Embedded field programmable gate array (eFPGA) technology allows the implementation of reconfigurable logic within the design of an application-specific integrated circuit (ASIC). This approach offers the low power and efficiency of an ASIC along with the ease of FPGA configuration, particularly beneficial for the use case of machine learning in the data pipeline of next-generation collider experiments. An open-source framework called "FABulous" was used to design eFPGAs using 130 nm and 28 nm CMOS technology nodes, which were subsequently fabricated and verified through testing. The capability of an eFPGA to act as a front-end readout chip was assessed using simulation of high energy particles passing through a silicon pixel sensor. A machine learning-based classifier, designed for reduction of sensor data at the source, was synthesized and configured onto the eFPGA. A successful proof-of-concept was demonstrated through reproduction of the expected algorithm result on the eFPGA with perfect accuracy. Finally, further development of the eFPGA technology and its application to collider detector readout is discussed.

47 OTHER INSTRUMENTATION↗

The Majorana low-noise low-background front-end electronics

The Majorana Demonstrator will search for the neutrinoless double beta decay (ββ(0ν)) of the isotope ⁷⁶Ge with a mixed array of enriched and natural germanium detectors. In view of the next generation of tonne-scale germanium-based ββ(0ν)-decay searches, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039-keV Q-value of the ⁷⁶Ge ββ(0ν)-decay. Such a requirement on the background level significantly constrains the design of the readout electronics, which is further driven by noise and energy resolution performances. We present here the low-noise low-background front-end electronics developed for the low-capacitance p-type point contact (P-PC) germanium detectors of the Majorana Demonstrator. This resistive-feedback front-end, specifically designed to have low mass, is fabricated on a radioassayed fused-silica substrate where the feedback resistor consists of a sputtered thin film of high purity amorphous germanium and the feedback capacitor is based on the capacitance between gold conductive traces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Characterization and Performance of the Luminosity Monitors for the Qweak Experiment at Jefferson Lab

The $Q_{weak}$ experiment at Jefferson Lab is a precision measurement of the weak charge of the proton using parity-violating electron scattering. To make this measurement the experiment uses diagnostic detectors with small counting statistical errors that provide information about beam and target properties. The $Q_{weak}$ luminosity monitors were designed to provide this information. The luminosity monitors are arrays of quartz \v Cerenkov detectors coupled with air lightguides to photomultiplier tubes operating in unity gain mode and read out in current mode. There are two sets of luminosity monitors, a ``downstream'' array at a mean laboratory scattering angle of 0.5 degrees that detects an equal mixture of elastic e-p and M\o ller scattered electrons and an ``upstream'' array at a mean scattering angle of 5 degrees that primarily detects low energy M\o ller scattered electrons. The monitors can also be equipped with high gain bases to operate in pulse counting mode for use as beam monitors in special low beam current diagnostic runs. The characterization and performance of the luminosity monitors will be presented.

Leacock, John↗