Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Hubble Space Telescope Program on STS-95 Supported by Space Acceleration Measurement System for Free Flyers

John Glenn's historic return to space was a primary focus of the STS 95 space shuttle mission; however, the 83 science payloads aboard were the focus of the flight activities. One of the payloads, the Hubble Space Telescope Orbital System Test (HOST), was flown in the cargo bay by the NASA Goddard Space Flight Center. It served as a space flight test of upgrade components for the telescope before they are installed in the shuttle for the next Hubble Space Telescope servicing mission. One of the upgrade components is a cryogenic cooling system for the Near Infrared Camera and Multi-Object Spectrometer (NICMOS). The cooling is required for low noise in the receiver's sensitive electronic instrumentation. Originally, a passive system using dry ice cooled NICMOS, but the ice leaked away and must be replaced. The active cryogenic cooler can provide the cold temperatures required for the NICMOS, but there was a concern that it would create vibrations that would affect the fine pointing accuracy of the Hubble platform.

Kacpura, Thomas J.↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The STARDUST Discovery Mission: Data from the Encounter with Comet Wild 2 and the Expected Sample Return

On January 2,2004, the STARDUST spacecraft made the closest ever flyby (236 km) of the nucleus of a comet - Comet Wild 2. During the fly by the spacecraft collected samples of dust from the coma of the comet. These samples will be returned to Earth on January 15,2006. After a brief preliminary examination to establish the nature of the returned samples, they will be made available to the general scientific community for study. In addition to its aerogel dust collector, the STARDUST spacecraft was also equipped with instruments that made in situ measurements of the comet during the flyby. These included several dust impact monitors, a mass spectrometer, and a camera. The spacecraft's communication system was also used to place dynamical constraints on the mass of the nucleus and the number of impacts the spacecraft had with large particles. The data taken by these instruments indicate that the spacecraft successfully captured coma samples. These instruments, particularly the camera, also demonstrated that Wild 2 is unlike any other object in the Solar System previously visited by a spacecraft. During my talk I will discuss the scientific goals of the STARDUST mission and provide an overview of its design and flight to date. I will then end with a description of the exciting data returned by the spacecraft during the recent encounter with Wild 2 and discuss what these data tell us about the nature of comets. It will probably come as no surprise that the encounter data raise as many (or more) new questions as they answer old ones.

Sandford, Scott A.↗

Telescope With A Two-Color Camera And Two Imaging Spectrometers

Proposed remote-sensing optical instrument system includes two charge-coupled-device (CCD) video cameras sensitive to different colors of light; line-imaging infrared spectrometer; and line-imaging ultraviolet spectrometer; all sharing common telescope foreoptics. Principal advantages: compactness and light weight.

Chrisp, Michael P.↗

Photogrammetry System and Method for Determining Relative Motion Between Two Bodies

A photogrammetry system and method provide for determining the relative position between two objects. The system utilizes one or more imaging devices, such as high speed cameras, that are mounted on a first body, and three or more photogrammetry targets of a known location on a second body. The system and method can be utilized with cameras having fish-eye, hyperbolic, omnidirectional, or other lenses. The system and method do not require overlapping fields-of-view if two or more cameras are utilized. The system and method derive relative orientation by equally weighting information from an arbitrary number of heterogeneous cameras, all with non-overlapping fields-of-view. Furthermore, the system can make the measurements with arbitrary wide-angle lenses on the cameras.

Miller, Samuel A.↗

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

An investigation of optical feedback to extend the frequency response of solid-state detector systems

A primary limitation of many solid-state photodetectors used in electro-optical systems such as the facsimile camera is their slow response in converting light intensities into electrical signals. An optical feedback technique is presented which can extend the frequency response of systems that use these detectors by orders of magnitude without significantly degrading their signal-to-noise performance. This technique is analyzed to predict improvement, implemented, and evaluated to verify analytical results.

Katzberg, S. J.↗

Estimation of the absolute position of mobile systems by an optoelectronic processor

A method that determine the absolute position of a mobile system with a hybrid optoelectronic processor has been developed. Position estimates are based on an analysis of circular landmarks that are detected by a TV camera attached to the mobile system. The difference between the known shape of the landmark and its image provides the information needed to determine the absolute position of the mobile system. For robust operation, the parameters of the landmark image are extracted at high speeds using an optical processor that performs an optical Hough transform. The coordinates of the mobile system are computed from these parameters in a digital co-processor using fast algorithms. Different sources of position estimation errors have also been analyzed, and consequent algorithms to improve the navigation performance of the mobile system have been developed and evaluated by both computer simulation and experiments.

Feng, Liqiang↗

Skylab's photographic workhorse

There are ten Data Acquisition Cameras (DAC) aboard the Skylab workshop, and one additional is aboard each of the three command modules that ferry astronauts to Skylab. These cameras will transport approximately 40,000 feet of 16-mm film at frame rates from time exposures to 24 frames per second (fps). The heart of the 16-mm DAC system is a unique sequence camera. Approximately 80% of the Skylab 16-mm film will be exposed at 2 fps to maximize data acquisition time and remain within spacecraft return weight limitations. Of the approximately 225 accessories, the most unique item is the 400-foot magazine system.-

Gerlach, R.↗

Video Camera Improvements to Support Hanford Tank Farms - 17141

Hanford Tank Farms consist of 177 underground storage tanks that contain 56 million gallons of radioactive waste. The current mission is to safely manage this waste in preparation to feed the Waste Treatment Plant. Fulfilling this mission includes inspecting each tank regularly to ensure tank integrity and support ongoing operations such as transferring waste from older single-shell tanks to the newer double-shell tanks. Video cameras derived from commercially available equipment have provided the ability to remotely see inside the tanks, reducing some of the challenges of fulfilling this mission. However, there are many challenges and limitations with the currently used video systems. Among some of the challenges are limited tank interior entry points for camera deployment, high radiation dose rates, limited equipment longevity in the environmental conditions, need for high resolution image quality, low light conditions, and in-tank obstructions. Washington River Protection Solutions (WRPS) has identified and tested new video systems that will effectively manage these challenges and increase capability, efficiency, and improve safety. The new camera systems are planned for deployment to support the next Single Shell Tank Retrieval Project in the A/AX tank Farm complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Fault-Controlled Topography on Fluvio-Deltaic Sedimentary Systems in Eberswalde Crater, Mars

Eberswalde crater was selected as a candidate landing site for the Mars Science Laboratory (MSL) mission based on the presence of a fan-shaped sedimentary deposit interpreted as a delta. We have identified and mapped five other candidate fluvio -deltaic systems in the crater, using images and digital terrain models (DTMs) derived from the Mars Reconnaissance Orbiter (MRO) High Resolution Imaging Science Experiment (HiRISE) and Context Camera (CTX). All of these systems consist of the same three stratigraphic units: (1) an upper layered unit, conformable with (2) a subpolygonally fractured unit, unconformably overlying (3) a pitted unit. We have also mapped a system of NNE-trending scarps interpreted as dip-slip faults that pre-date the fluvial -lacustrine deposits. The post-impact regional faulting may have generated the large-scale topography within the crater, which consists of a Western Basin, an Eastern Basin, and a central high. This topography subsequently provided depositional sinks for sediment entering the crater and controlled the geomorphic pattern of delta development.

Rice, Melissa S.↗

Imaging vs. non-imaging in long range neutron detection scenarios.

Standoff neutron detection technology has advanced in recent years, primarily for counterterrorism applications. Sandia National Laboratories has developed the Neutron Scatter Camera -- a fast neutron imaging system using liquid scintillator with potential applications in long range neutron detection. This talk will explore the pros, cons and practical uses of the Neutron Scatter Camera versus more traditional neutron detectors such as He-3 proportional counters. Several applications for neutron detection and imaging will be explored. We will perform predictive calculations of the response of the Neutron Scatter Camera and traditional He-3 detectors. The applications range from counterterrorism to arms control to safeguards. We will discuss future evolution of the scatter camera to enhance long range detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗

Final Scientific/Technical Report: Real Time Particle Size and Settling Velocity for In-Situ Monitoring of Deep-Sea Polymetallic Nodule Mining

In the coming decade, it is anticipated that deep-sea mining activities will commence throughout the deep ocean, at depths around 4000-6000m where vast deposits of baseball-sized rocks called polymetallic nodules lay on the seabed. These nodules contain resources such as cobalt, copper and nickel which are needed to produce batteries for electric vehicles. Collector machines driving on the seabed and gathering these nodules will stir up clouds of sediment, and there is concern about how the resulting concentration of sediment in the near-bottom ocean water will affect deep and mid-ocean biology. There is currently no technology capable of comprehensively monitoring the concentrations and properties of stirred up sediment in the deep. This project addressed this critical gap by developing a deep-sea particle measurement system (Real-Time Size and Settling Velocity, RTSSV) that uses a multi-camera high-resolution video imaging system, with accompanying image processing, to measure the concentration, size distribution and settling speed of sediment. Importantly, these measurements are made in-situ, so that delicate sediment aggregates will not be disturbed, as is the case when collecting samples at depth to be measured in the lab. The instrument can be mounted on a variety of established deep-sea platforms such as moorings, AUVs and ROVs, providing data in near real time, where the key measurements need to be made—from the source of the sediment disturbance and throughout the resulting plume—vital for determining if deep-sea mining can be done in an environmentally responsible manner. The developed system (RTSSV) will possess the only such capability worldwide, giving a US-based group a substantial competitive advantage as this newly evolving global industry develops. As added value, the technology will also have widespread application to the offshore oil and gas industry, dredging industry, and to sediment science research.

47 OTHER INSTRUMENTATION↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗

Stereoscopic Machine-Vision System Using Projected Circles

A machine-vision system capable of detecting obstacles large enough to damage or trap a robotic vehicle is undergoing development. The system includes (1) a pattern generator that projects concentric circles of laser light forward onto the terrain, (2) a stereoscopic pair of cameras that are aimed forward to acquire images of the circles, (3) a frame grabber and digitizer for acquiring image data from the cameras, and (4) a single-board computer that processes the data. The system is being developed as a prototype of machine- vision systems to enable robotic vehicles ( rovers ) on remote planets to avoid craters, large rocks, and other terrain features that could capture or damage the vehicles. Potential terrestrial applications of systems like this one could include terrain mapping, collision avoidance, navigation of robotic vehicles, mining, and robotic rescue. This system is based partly on the same principles as those of a prior stereoscopic machine-vision system in which the cameras acquire images of a single stripe of laser light that is swept forward across the terrain. However, this system is designed to afford improvements over some of the undesirable features of the prior system, including the need for a pan-and-tilt mechanism to aim the laser to generate the swept stripe, ambiguities in interpretation of the single-stripe image, the time needed to sweep the stripe across the terrain and process the data from many images acquired during that time, and difficulty of calibration because of the narrowness of the stripe. In this system, the pattern generator does not contain any moving parts and need not be mounted on a pan-and-tilt mechanism: the pattern of concentric circles is projected steadily in the forward direction. The system calibrates itself by use of data acquired during projection of the concentric-circle pattern onto a known target representing flat ground. The calibration- target image data are stored in the computer memory for use as a template in processing terrain images. During operation on terrain, the images acquired by the left and right cameras are analyzed. The analysis includes (1) computation of the horizontal and vertical dimensions and the aspect ratios of rectangles that bound the circle images and (2) comparison of these aspect ratios with those of the template. Coordinates of distortions of the circles are used to identify and locate objects. If the analysis leads to identification of an object of significant size, then stereoscopicvision algorithms are used to estimate the distance to the object. The time taken in performing this analysis on a single pair of images acquired by the left and right cameras in this system is a fraction of the time taken in processing the many pairs of images acquired in a sweep of the laser stripe across the field of view in the prior system. The results of the analysis include data on sizes and shapes of, and distances and directions to, objects. Coordinates of objects are updated as the vehicle moves so that intelligent decisions regarding speed and direction can be made. The results of the analysis are utilized in a computational decision-making process that generates obstacle-avoidance data and feeds those data to the control system of the robotic vehicle.

Mackey, Jeffrey R.↗

Electro optical system to measure strains at high temperature

The goals of this proposal were to develop a prototype of an electro-optics system for the measurement of strains in structures at high temperatures and to perform a test under field conditions. In the research task section, the topics addressed include: (1) correction of the effect of vibrations and thermal currents by means of an active compensation system; (2) reduction of the speckle noise by means of electronic filter and TV signal reconstruction circuit; (4) compensation of the rigid body motions by mounting the camera in a universal motion system; and (5) removal of phase errors left by the active compensation system by dynamic reading. In the design and construction section, the topics addressed include: (1) preliminary design; (2) final design; (3) software development; (4) signal conditioning; (5) data processing; (6) recorrelation of two holograms in the presence of rigid body motions; and (7) phase extraction using a computer generated image. Testing in the high temperature oven is also addressed.

Sciammarella, Cesar A.↗