Search NASA⌕ Search

SEARCH · Search NASA

Results for “clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

High Precision Time Transfer in Space with a Hydrogen Maser on MIR

An atomic hydrogen maser clock system designed for long term operation in space will be installed on the Russian space station Mir, in late 1997. The H-maser's frequency stability will be measured using pulsed laser time transfer techniques. Daily time comparisons made with a precision of better than 100 picoseconds will allow an assessment of the long term stability of the space maser at a level on the order of 1 part in 10(sup 15) or better. Laser pulse arrival times at the spacecraft will be recorded with a resolution of 10 picoseconds relative to the space clock's time scale. Cube corner reflectors will reflect the pulses back to the Earth laser station to determine the propagation delay and enable comparison with the Earth-based time scale. Data for relativistic and gravitational frequency corrections will be obtained from a Global Positioning System (GPS) receiver.

Mattison, Edward M.↗

Performance Improvement Through Indexing of Turbine Airfoils: Numerical Simulation - Part 2

An experimental/analytical study has been conducted to determine the performance improvements achievable by circumferentially indexing succeeding rows of turbine stator airfoils. A series of tests was conducted to experimentally investigate stator wake clocking effects on the performance of the space shuttle main engine (SSME) alternate turbopump development (ATD) fuel turbine test article (TTA). The results from this study indicate that significant increases in stage efficiency can be attained through application of this airfoil clocking concept. Details of the experiment and its results are documented in part 1 of this paper. In order to gain insight into the mechanisms of the performance improvement, extensive computational fluid dynamics (CFD) simulations were executed. The subject of the present paper is the initial results from the CFD investigation of the configurations and conditions detailed in part 1 of the paper. To characterize the aerodynamic environments in the experimental test series, two-dimensional (2D), time accurate, multistage, viscous analyses were performed at the TTA midspan. Computational analyses for five different circumferential positions of the first stage stator have been completed. Details of the computational procedure and the results are presented. The analytical results verify the experimentally demonstrated performance improvement and are compared with data whenever possible. Predictions of time-averaged turbine efficiencies as well as gas conditions throughout the flow field are presented. An initial understanding of the turbine performance improvement mechanism based on the results from this investigation is described.

Griffin, Lisa W.↗

A Method to Analyze and Optimize the Load Sharing of Split Path Transmissions

Split-path transmissions are promising alternatives to the common planetary transmissions for rotorcraft. Heretofore, split-path designs proposed for or used in rotorcraft have featured load-sharing devices that add undesirable weight and complexity to the designs. A method was developed to analyze and optimize the load sharing in split-path transmissions without load-sharing devices. The method uses the clocking angle as a design parameter to optimize for equal load sharing. In addition, the clocking angle tolerance necessary to maintain acceptable load sharing can be calculated. The method evaluates the effects of gear-shaft twisting and bending, tooth bending, Hertzian deformations within bearings, and movement of bearing supports on load sharing. It was used to study the NASA split-path test gearbox and the U.S. Army's Comanche helicopter main rotor gearbox. Acceptable load sharing was found to be achievable and maintainable by using proven manufacturing processes. The analytical results compare favorably to available experimental data.

Krantz, Timothy L.↗

Spacecraft Tests of General Relativity

Current spacecraft tests of general relativity depend on coherent radio tracking referred to atomic frequency standards at the ground stations. This paper addresses the possibility of improved tests using essentially the current system, but with the added possibility of a space-borne atomic clock. Outside of the obvious measurement of the gravitational frequency shift of the spacecraft clock, a successor to the suborbital flight of a Scout D rocket in 1976 (GP-A Project), other metric tests would benefit most directly by a possible improved sensitivity for the reduced coherent data. For purposes of illustration, two possible missions are discussed. The first is a highly eccentric Earth orbiter, and the second a solar-conjunction experiment to measure the Shapiro time delay using coherent Doppler data instead of the conventional ranging modulation.

Anderson, John D.↗

Robust Real-Time Wide-Area Differential GPS Navigation

The present invention provides a method and a device for providing superior differential GPS positioning data. The system includes a group of GPS receiving ground stations covering a wide area of the Earth's surface. Unlike other differential GPS systems wherein the known position of each ground station is used to geometrically compute an ephemeris for each GPS satellite. the present system utilizes real-time computation of satellite orbits based on GPS data received from fixed ground stations through a Kalman-type filter/smoother whose output adjusts a real-time orbital model. ne orbital model produces and outputs orbital corrections allowing satellite ephemerides to be known with considerable greater accuracy than from die GPS system broadcasts. The modeled orbits are propagated ahead in time and differenced with actual pseudorange data to compute clock offsets at rapid intervals to compensate for SA clock dither. The orbital and dock calculations are based on dual frequency GPS data which allow computation of estimated signal delay at each ionospheric point. These delay data are used in real-time to construct and update an ionospheric shell map of total electron content which is output as part of the orbital correction data. thereby allowing single frequency users to estimate ionospheric delay with an accuracy approaching that of dual frequency users.

Yunck, Thomas P.↗

It's About Time!

Everything we do in VLBI is connected to time. In this contribution, we review 28 orders of magnitude of the spectrum of time ranging from a few hundred femtoseconds (i.e. one degree of phase at X-band - Pi x 10(exp -13) seconds) upwards to tens of millions of years (i.e. ten million years Pi x 10(exp 14) seconds). In this discussion, we will pay special attention to the relation between the underlying oscillator (the frequency standard that defines a clock's rate) and the time kept by the clock (which counts the oscillations of the frequency standard). We will consider two different types of time - time kept by counting an atomic frequency standard (Hydrogen Maser or Cesium), and time reckoned by the rotation of the Earth underneath the stars and sun.

Clark, Tom↗

Iodine-Xenon Dating: Sensitive Chronometer for Reprocessing in the Primitive Solar System

The I-Xe chronometer is based upon decay of I-129 to Xe-129 in the early Solar System. Recent comparison of I-Xe system in individual mineral separates from twelve different meteorites with independent Pb-Pb data has demonstrated that I-Xe clock is a reliable sensitive chronometer when applied to a single mineral system. Since most iodine hosts are secondary minerals, the I-Xe clock generally records post-formational processing, providing the information on early meteorite evolution. Absolute I-Xe ages can be found by normalization using the measured I-Xe and Pb-Pb ages of Acapulco phosphate (4.557 plus or minus 0.002 Ga). Absolute ages for the I-Xe internal standards Shallow water and Bjurbole, 4.566 plus or minus 0.002 Ga and 4.565 plus or minus 0.003 Ga, respectively, provide absolute I-Xe ages for all other samples. The I-Xe age of bulk meteorite is meaningful and interpretable only when the carrier of primordial iodine is a major mineral phase (e. g., enstatite chondrites). Using the "monomineral" approach, separated phases from the Richardton H5 chondrite provide a case history of post-formational alteration in this object. This work applies the I-Xe chronometer to determine the times of reprocessing of selected minerals in single meteorite types. A preliminary account of this work was recently reported. Additional information is contained in the original extended abstract.

Pravdivtseva, O. V.↗

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

Gravitational Physics Research

Gravitational physics research at ISPAE is connected with NASA's Relativity Mission (Gravity Probe B (GP-B)) which will perform a test of Einstein's General Relativity Theory. GP-B will measure the geodetic and motional effect predicted by General Relativity Theory with extremely stable and sensitive gyroscopes in an earth orbiting satellite. Both effects cause a very small precession of the gyroscope spin axis. The goal of the GP-B experiment is the measurement of the gyroscope precession with very high precision. GP-B is being developed by a team at Stanford University and is scheduled for launch in the year 2001. The related UAH research is a collaboration with Stanford University and MSFC. This research is focussed primarily on the error analysis and data reduction methods of the experiment but includes other topics concerned with experiment systems and their performance affecting the science measurements. The hydrogen maser is the most accurate and stable clock available. It will be used in future gravitational physics missions to measure relativistic effects such as the second order Doppler effect. The HMC experiment, currently under development at the Smithsonian Astrophysical Observatory (SAO), will test the performance and capability of the hydrogen maser clock for gravitational physics measurements. UAH in collaboration with the SAO science team will study methods to evaluate the behavior and performance of the HMC. The GP-B data analysis developed by the Stanford group involves complicated mathematical operations. This situation led to the idea to investigate alternate and possibly simpler mathematical procedures to extract the GP-B measurements form the data stream. Comparison of different methods would increase the confidence in the selected scheme.

Wu, S. T.↗

Computational Analyses of Propulsion Aeroacoustics for Mixed Flow Nozzle Pylon Installation at Takeoff

A CFD analyses is presented for a set of baseline and noise suppression mixed flow nozzles with and without a pylon installation. The five model configurations are as follows; a baselinecore/fan dual-stream nozzle with an external plug, a chevron mixer nozzle with a peak on the symmetry plane with external plug, both of the above nozzles with an installed bifurcatingpylon and lastly a clocked chevron mixer nozzle such that a trough is aligned with the center of the pylon. The fluid flow is simulated by solving the asymptotically steady, compressible, Reynolds-averaged Navier-Stokes equations using an implicit, up-wind, flux-difference splitting finite volume scheme and standard two equation k-epsilon turbulence model with a linear stress representation. All computations are performed using the multiblock, parallel, structuredcode PAB3D. Results indicate that the clocked chevron with pylon case achieves the most optimal levels of average and peak turbulence kinetic energy and vorticity and therefore is expected to be the quietest of the five configurations tested. Further study is required to refine expressions which are indicative of noise and mate these with rigorous noise prediction models.

Massey, Steven J.↗

Applications Performance Under MPL and MPI on NAS IBM SP2

On July 5, 1994, an IBM Scalable POWER parallel System (IBM SP2) with 64 nodes, was installed at the Numerical Aerodynamic Simulation (NAS) Facility Each node of NAS IBM SP2 is a "wide node" consisting of a RISC 6000/590 workstation module with a clock of 66.5 MHz which can perform four floating point operations per clock with a peak performance of 266 Mflop/s. By the end of 1994, 64 nodes of IBM SP2 will be upgraded to 160 nodes with a peak performance of 42.5 Gflop/s. An overview of the IBM SP2 hardware is presented. The basic understanding of architectural details of RS 6000/590 will help application scientists the porting, optimizing, and tuning of codes from other machines such as the CRAY C90 and the Paragon to the NAS SP2. Optimization techniques such as quad-word loading, effective utilization of two floating point units, and data cache optimization of RS 6000/590 is illustrated, with examples giving performance gains at each optimization step. The conversion of codes using Intel's message passing library NX to codes using native Message Passing Library (MPL) and the Message Passing Interface (NMI) library available on the IBM SP2 is illustrated. In particular, we will present the performance of Fast Fourier Transform (FFT) kernel from NAS Parallel Benchmarks (NPB) under MPL and MPI. We have also optimized some of Fortran BLAS 2 and BLAS 3 routines, e.g., the optimized Fortran DAXPY runs at 175 Mflop/s and optimized Fortran DGEMM runs at 230 Mflop/s per node. The performance of the NPB (Class B) on the IBM SP2 is compared with the CRAY C90, Intel Paragon, TMC CM-5E, and the CRAY T3D.

Saini, Subhash↗

Non-Intrusive Pressure/Multipurpose Sensor and Method

Method and apparatus are provided for determining pressure using a non-intrusive sensor that is easily attachable to the plumbing of a pressurized system. A bent mode implementation and a hoop mode implementation of the invention are disclosed. Each of these implementations is able to nonintrusively measure pressure while fluid is flowing. As well, each implementation may be used to measure mass flow rate simultaneously with pressure. An ultra low noise control system is provided for making pressure measurements during gas flow. The control system includes two tunable digital bandpass filters with center frequencies that are responsive to a clock frequency. The clock frequency is divided by a factor of N to produce a driving vibrational signal for resonating a metal sensor section.

Smith, William C.↗

Use of Novel Light Sources and Melatonin Delivery Systems in the Maintenance of Temporal Organization of Physiological and Behavioral Circadian Rhythms

The synchronization of physiological and behavioral rhythms are controlled by an endogenous biological clock. It is generally accepted that environmental lighting is the strongest entrainer of this clock. The pineal gland is an important physiological transducer of environmental lighting via systemic melatonin secretion. We have used a novel light source using light emitting diode (LED) technology to entrain circadian rhythms in rats, and propose a novel percutaneous exogenous melatonin delivery system to entrain rat rhythms. We used 5 groups of Sprague-Dawley rats (175-350 g; N = 8/group) and showed normal entrainment of gross locomotor activity, feeding, and drinking circadian rhythms at light intensities varying from 80 lux to 0.1 lux (22.4 to 0.03 sq cm). To improve the delivery of melatonin across the skin stratum corneum it was formulated in a suitable vehicle in a transdermal drug delivery system. Various saturated and unsaturated fatty acids were used E, akin penetration enhancers. Our best vehicle formulation was achieved with a combination-of ethano1:water (60:40) along with 5% oleic acid as the enhancer. This formulation mixture was studied using Franz diffusion cell (0.636 sq cm diffusional area) and 1 cu cm dorsal skin isolated from Sprague Dawley rats. Our results showed that oleic acid in combination with the water ethanol mixture improved the flux of melatonin by more than 18 fold. The lag time for melatonin permeation was 2-3 hrs and the peak concentrations were achieved in 8-10 hrs. Our approaches in the future will involve the use of our transdermal melatonin delivery system and under the influence of LED light and microgravity.

Winget, C. M.↗

Self-Timed Digital System Design

A timing and control strategy that can be used to realize synchronous systems with a level of performance that approaches that of asynchronous circuits or systems was developed in this work. This approach is based upon a single-phase synchronous circuit/system architecture with a variable period clock. The handshaking signals required for asynchronous self-timed circuits are not needed. Dynamic power supply current monitoring is used to generate the timing information, that is comparable to the completion signal found in self-timed circuits; this timing information is used to modify the circuit clock period.

Walker, Alvernon↗

An Approach for Self-Timed Synchronous CMOS Circuit Design

In this letter we present a timing and control strategy that can be used to realize synchronous systems with a level of performance that approaches that of asynchronous circuits or systems. This approach is based upon a single-phase synchronous circuit/system architecture with a variable period clock. The handshaking signals required for asynchronous self-timed circuits are not needed. Dynamic power supply current monitoring is used to generate the timing information, that is comparable to the completion signal found in self-timed circuits; this timing information is used to modi@ the circuit clock period. This letter is concluded with an example of the proposed approach applied to a static CMOS ripple-carry adder.

Walker, Alvernon↗

Food-anticipatory activity and liver per1-luc activity in diabetic transgenic rats

The mammalian Per1 gene is an important component of the core cellular clock mechanism responsible for circadian rhythms. The rodent liver and other tissues rhythmically express Per1 in vitro but typically damp out within a few cycles. In the liver, the peak of this rhythm occurs in the late subjective night in an ad lib-fed rat, but will show a large phase advance in response to restricted availability of food during the day. The relationship between this shift in the liver clock and food-anticipatory activity (FAA), the circadian behavior entrained by daily feeding, is currently unknown. Insulin is released during feeding in mammals and could serve as an entraining signal to the liver. To test the role of insulin in the shift in liver Per1 expression and the generation of FAA, per-luciferase transgenic rats were made diabetic with a single injection of streptozotocine. Following 1 week of restricted feeding and locomotor activity monitoring, liver was collected for per-luc recording. In two separate experiments, FAA emerged and liver Per1 phase-shifted in response to daytime 8-h food restriction. The results rule out insulin as a necessary component of this system.

NASA Discipline Space Human Factors↗

Association of intrinsic circadian period with morningness-eveningness, usual wake time, and circadian phase

The biological basis of preferences for morning or evening activity patterns ("early birds" and "night owls") has been hypothesized but has remained elusive. The authors reported that, compared with evening types, the circadian pacemaker of morning types was entrained to an earlier hour with respect to both clock time and wake time. The present study explores a chronobiological mechanism by which the biological clock of morning types may be set to an earlier hour. Intrinsic period, a fundamental property of the circadian system, was measured in a month-long inpatient study. A subset of participants also had their circadian phase assessed. Participants completed a morningness-eveningness questionnaire before study. Circadian period was correlated with morningness-eveningness, circadian phase, and wake time, demonstrating that a fundamental property of the circadian pacemaker is correlated with the behavioral trait of morningness-eveningness.

Non-NASA Center↗

A Unified Fault-Tolerance Protocol

Davies and Wakerly show that Byzantine fault tolerance can be achieved by a cascade of broadcasts and middle value select functions. We present an extension of the Davies and Wakerly protocol, the unified protocol, and its proof of correctness. We prove that it satisfies validity and agreement properties for communication of exact values. We then introduce bounded communication error into the model. Inexact communication is inherent for clock synchronization protocols. We prove that validity and agreement properties hold for inexact communication, and that exact communication is a special case. As a running example, we illustrate the unified protocol using the SPIDER family of fault-tolerant architectures. In particular we demonstrate that the SPIDER interactive consistency, distributed diagnosis, and clock synchronization protocols are instances of the unified protocol.

Miner, Paul↗