Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Room temperature continuous wave operation of quantum cascade lasers with 12.5% wall plug efficiency

An InP based quantum cascade laser heterostructure emitting at 4.6 {mu}m was grown with gas-source molecular beam epitaxy. The wafer was processed into a conventional double-channel ridge waveguide geometry with ridge widths of 19.7 and 10.6 {mu}m without semi-insulating InP regrowth. An uncoated, narrow ridge device with a 4.8 mm cavity length was epilayer down bonded to a diamond submount and exhibits 2.5 W maximum output power with a wall plug efficiency of 12.5% at room temperature in continuous wave operation.

36 MATERIALS SCIENCE↗

Use of the absolute phase in frequency modulated continuous wave plasma reflectometry

In frequency modulated continuous wave reflectometry, used for density profile measurement in fusion plasmas, it is usual to measure the beat frequency between the launched wave and the reflected wave, and from this to calculate the position of the reflecting layer in the plasma. The absolute phase of the beat signal is usually neglected. The reason is that the phase shift between sweeps is usually comparable with or more than 2{pi}, leading to an ambiguity that is impossible to resolve. However, recent observations on the MAST tokamak have shown that, under quiet plasma conditions (this term has to be defined), the phase shift between sweeps is small compared with 2{pi} and the phase ambiguity can be readily resolved. The reflectometer signal is then being analyzed as an interferometer signal would normally be, and there is a substantial improvement in spatial resolution. The method is illustrated by application to small edge localized mode precursor and allows what is believed to be the first quantitative measurement of the displacement of the plasma boundary by such a precursor mode. The errors in both the absolute phase measurement and the more conventional frequency measurement are also estimated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First density profile measurements using frequency modulation of the continuous wave reflectometry on JET

We present the main design options and implementation of an X-mode reflectometer developed and successfully installed at JET using an innovative approach. It aims to prove the viability of measuring density profiles with high spatial and temporal resolution using broadband reflectometry operating in long and complex transmission lines. It probes the plasma with magnetic fields between 2.4 and 3.0 T using the V band [{approx}(0-1.4)x10{sup 19} m{sup -3}]. The first experimental results show the high sensitivity of the diagnostic when measuring changes in the plasma density profile occurring ITER relevant regimes, such as ELMy H-modes. The successful demonstration of this concept motivated the upgrade of the JET frequency modulation of the continuous wave (FMCW) reflectometry diagnostic, to probe both the edge and core. This new system is essential to prove the viability of using the FMCW reflectometry technique to probe the plasma in next step devices, such as ITER, since they share the same waveguide complexity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid-state continuous Lyman-alpha source for laser-cooling of antihydrogen

Cooling antihydrogen atoms is important for future experiments both to test the fundamental CPT symmetry by high-resolution laser spectroscopy and also to measure the gravitational acceleration of antimatter. Laser-cooling of antihydrogen can be done on the strong 1 S-2 P transition at the wavelength of Lyman-alpha (121.6 nm). Ongoing work to set up a solid-state continuous-wave laser source at Lyman-alpha is described.

74 ATOMIC AND MOLECULAR PHYSICS↗

Linearized semiclassical initial value time correlation functions with maximum entropy analytic continuation

The maximum entropy analytic continuation (MEAC) method is used to extend the range of accuracy of the linearized semiclassical initial value representation (LSC-IVR)/classical Wigner approximation for real time correlation functions. The LSC-IVR provides a very effective 'prior' for the MEAC procedure since it is very good for short times, exact for all time and temperature for harmonic potentials (even for correlation functions of nonlinear operators), and becomes exact in the classical high temperature limit. This combined MEAC+LSC/IVR approach is applied here to two highly nonlinear dynamical systems, a pure quartic potential in one dimensional and liquid para-hydrogen at two thermal state points (25K and 14K under nearly zero external pressure). The former example shows the MEAC procedure to be a very significant enhancement of the LSC-IVR, for correlation functions of both linear and nonlinear operators, and especially at low temperature where semiclassical approximations are least accurate. For liquid para-hydrogen, the LSC-IVR is seen already to be excellent at T = 25K, but the MEAC procedure produces a significant correction at the lower temperature (T = 14K). Comparisons are also made to how the MEAC procedure is able to provide corrections for other trajectory-based dynamical approximations when used as priors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous phase transition in the region of the vacuum arc cathode spot

A model for the near-cathode region of electric arcs is presented to investigate the liquid-plasma phase transition in the cathode spot region. Due to the high values of pressure and temperature after spot ignition, a 'continuous phase transition' occurs in the liquid-vapor interface. A set of fluid equations with suitable boundary conditions have been solved to obtain diagrams of the spot plasma in the temperature-density plane during the spot evolution for a typical spot. To evaluate the model, the magnitude of some essential quantities such as the mean ion charge state of plasma and current density have been calculated, which are in accordance with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Experiments with a Continuous L{sub 2}-exponential Merit Function for Semi-Infinite Programming

Here, we present some numerical experiments with a reduction method for solving nonlinear semi-infinite programming (SIP) problems. The method relies on a line search technique to ensure a sufficient decrease of a L{sub 2}-exponential merit function. The proposed merit function is continuous for SIP and improves the algorithm efficiency when compared with other previously tested merit functions. A comparison with other reduction methods is also included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On exchangeable continuous variable systems

We investigate permutation-invariant continuous variable quantum states and their covariance matrices. We provide a complete characterization of the latter with respect to permutation invariance and exchangeability and representing convex combinations of tensor power states. On the level of the respective density operators this leads to necessary criteria for all these properties which become necessary and sufficient for Gaussian states. For these we use the derived results to provide de Finetti-type theorems for various distance measures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A continuous kilohertz Cu K{alpha} source produced by submillijoule femtosecond laser pulses for phase contrast imaging

We report a continuously operated Cu K{alpha} x-ray source produced by a commercial kilohertz submillijoule femtosecond laser system. The source has an x-ray conversion of {approx}4x10{sup -5} into K{alpha} line emission at 8.05 keV. The microplasma x-ray source has a size of 8 {mu}m (full width at half maximum) produced by focusing 260 {mu}J laser pulses on a moving Cu-wire target. An average photon flux of {approx}1.1x10{sup 9} photons/sr/s is obtained using the above laser pulses. The source has been used to record phase contrast images of test samples. This compact x-ray source can serve as a low cost operating system for phase contrast imaging in clinical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Growth of silver nanoparticles of variable and controlled diameter in silica-based and soda-lime glasses by simultaneous continuous ultraviolet irradiation and heat treatment

We report on the space-selective precipitation of silver nanoparticles in silica-based and silver-exchanged soda-lime glasses by simultaneous continuous wave ultraviolet exposure and heat treatment. In silica-based glasses, we explain that simultaneous treatments lead to much higher silver nanoparticles concentration than similar treatments performed into two separated steps by minimizing the detrimental influence of oxidation on the nanoparticles' growth. In the case of silver-exchanged soda-lime glasses, nanoparticles are observed with both small and larger diameters of about 1 and 7 nm, whose concentrations depend both on the laser power density and on the heating temperature.

36 MATERIALS SCIENCE↗

The consequence of continuous current branching on current-noise spectra in field-effect and high-electron mobility transistors

The problems related with the intrinsic noise in FET/HEMT channels induced by continuous branching of the total current between channel and gate are considered in the framework of a simple analytical model and its predictions on the current-noise spectra. Main branching-induced effects such as the appearance of an additional noise related to the excitation of plasma waves, its dependence on FET/HEMT embedding circuits, interference properties, etc. are analysed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of film texture on magnetization reversal and switching field in continuous and patterned (Co/Pd) multilayers

We studied the reversal properties of perpendicular anisotropy (Co/Pd) multilayers with different crystallographic textures. In case of continuous films, an increase in the coercivity and reduction in the switching field distribution (SFD) were observed as the growth is improved. From magnetic force microscopy, a stripe-type domain configuration was observed in films deposited at low gas pressure while a bubble-type domain was observed in high pressure deposited films. In patterned films, the SFD did not vary significantly for samples with different textures although a 2 kOe increase in the switching field was measured. In patterned structures, the controllability of SFD may not be related to the improvement of film crystallographic growth as was observed for unpatterned films. The results from this study indicate that local variation in the intrinsic film properties plays a major role in the SFD.

36 MATERIALS SCIENCE↗

Quantum regression formula and luminescence spectra of two coupled modes under incoherent continuous pumping

We study the quantum regression formula for two coupled dissipative modes in the steady state under incoherent continuous pumping. We analyze the equations for one and two-time correlators, needed to compute the spectra of emission of the system, for two coupled harmonic oscillators (linear model), on the one hand, and two coupled two-level systems, on the other hand. We present a comparison between them, on the basis of fully analytical results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Off-axis stability of intense continuous relativistic beams

This paper investigates the stability of off-axis continuous intense relativistic beams propagating inside a circular conducting pipe. The equations of motion for the centroid and the envelope of slightly off-axis beams are derived and used to determine equilibrium and stability conditions for the beam transport. It is shown that depending on the parameters of the system, beams propagating along the pipe axis may become unstable due to the presence of the wall, imposing a fundamental limitation in the effective area that an equilibrium beam can occupy inside the conductor.

43 PARTICLE ACCELERATORS↗

3 W continuous-wave room temperature single-facet emission from quantum cascade lasers based on nonresonant extraction design approach

A strain-balanced, InP-based quantum cascade laser structure, designed for light emission at 4.6 {mu}m using a new nonresonant extraction design approach, was grown by molecular beam epitaxy. Removal of the restrictive two-phonon resonant condition, currently used in most structure designs, allows simultaneous optimization of several design parameters influencing laser performance. Following the growth, the structure was processed in buried heterostructure. Maximum single-ended continuous-wave optical power of 3 W was obtained at 293 K for devices with stripe dimensions of 5 mmx11.6 {mu}m. Corresponding maximum wallplug efficiency and threshold current density were measured to be 12.7% and 0.86 kA/cm{sup 2}.

36 MATERIALS SCIENCE↗

Continuous wavelet transform based time-scale and multifractal analysis of the nonlinear oscillations in a hollow cathode glow discharge plasma

Continuous wavelet transform (CWT) based time-scale and multifractal analyses have been carried out on the anode glow related nonlinear floating potential fluctuations in a hollow cathode glow discharge plasma. CWT has been used to obtain the contour and ridge plots. Scale shift (or inversely frequency shift), which is a typical nonlinear behavior, has been detected from the undulating contours. From the ridge plots, we have identified the presence of nonlinearity and degree of chaoticity. Using the wavelet transform modulus maxima technique we have obtained the multifractal spectrum for the fluctuations at different discharge voltages and the spectrum was observed to become a monofractal for periodic signals. These multifractal spectra were also used to estimate different quantities such as the correlation and fractal dimension, degree of multifractality, and complexity parameters. These estimations have been found to be consistent with the nonlinear time series analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 {mu}s. Accordingly, the sample is under excitation in 10{sup -4} part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 10{sup 10} V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗