Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Soil Water and Temperature System (SWATS) Instrument Handbook

The soil water and temperature system (SWATS) provides vertical profiles of soil temperature, soil-water potential, and soil moisture as a function of depth below the ground surface at hourly intervals. The temperature profiles are measured directly by in situ sensors at the Central Facility and many of the extended facilities of the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) site. The soil-water potential and soil moisture profiles are derived from measurements of soil temperature rise in response to small inputs of heat. Atmospheric scientists use the data in climate models to determine boundary conditions and to estimate the surface energy flux. The data are also useful to hydrologists, soil scientists, and agricultural scientists for determining the state of the soil.

54 ENVIRONMENTAL SCIENCES↗

Combining multi-objective optimization and bayesian model averaging to calibrate forecast ensembles of soil hydraulic models

Most studies in vadose zone hydrology use a single conceptual model for predictive inference and analysis. Focusing on the outcome of a single model is prone to statistical bias and underestimation of uncertainty. In this study, we combine multi-objective optimization and Bayesian Model Averaging (BMA) to generate forecast ensembles of soil hydraulic models. To illustrate our method, we use observed tensiometric pressure head data at three different depths in a layered vadose zone of volcanic origin in New Zealand. A set of seven different soil hydraulic models is calibrated using a multi-objective formulation with three different objective functions that each measure the mismatch between observed and predicted soil water pressure head at one specific depth. The Pareto solution space corresponding to these three objectives is estimated with AMALGAM, and used to generate four different model ensembles. These ensembles are post-processed with BMA and used for predictive analysis and uncertainty estimation. Our most important conclusions for the vadose zone under consideration are: (1) the mean BMA forecast exhibits similar predictive capabilities as the best individual performing soil hydraulic model, (2) the size of the BMA uncertainty ranges increase with increasing depth and dryness in the soil profile, (3) the best performing ensemble corresponds to the compromise (or balanced) solution of the three-objective Pareto surface, and (4) the combined multi-objective optimization and BMA framework proposed in this paper is very useful to generate forecast ensembles of soil hydraulic models.

58 GEOSCIENCES↗

A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps

A simplified method of verifying intensity modulated radiation therapy (IMRT) fields using a Varian aS500 amorphous silicon electronic portal imaging device (EPID) is demonstrated. Unlike previous approaches, it does not involve time consuming or complicated analytical processing of the data. The central axis pixel response of the EPID, as well as the profile characteristics obtained from images acquired with a 6 MV photon beam, was examined as a function of field size. Ion chamber measurements at various depths in a water phantom were then collected and it was found that at a specific depth d{sub ref}, the dose response and profile characteristics closely matched the results of the EPID analysis. The only manipulation required to be performed on the EPID images was the multiplication of a matrix of off axis ratio values to remove the effect of the flood field calibration. Similarly, d{sub ref} was found for 18 MV. Planar dose maps at d{sub ref} in a water phantom for a bar pattern, a strip pattern, and 14 clinical IMRT fields from two patient cases each being from a separate anatomical region, i.e., head and neck as well as the pelvis, for both energies were generated by the Pinnacle planning system (V7.4). EPID images of these fields were acquired and converted to planar dose maps and compared directly with the Pinnacle planar dose maps. Radiographic film dosimetry and a MapCHECK dosimetry device (Sun Nuclear Corporation, Melbourne, FL) were used as an independent verification of the dose distribution. Gamma analysis of the EPID, film, and Pinnacle planar dose maps generated for the clinical IMRT fields showed that approximately 97% of all points passed using a 3% dose/3mm DTA tolerance test. Based on the range of fields studied, the author's results appear to justify using this approach as a method to verify dose distributions calculated on a treatment planning system, including complex intensity modulated fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling of streamflow in a 30 km long reach spanning 5 years using OpenFOAM 5.x

Abstract. Developing accurate and efficient modeling techniques for streamflow at the tens-of-kilometers spatial scale and multi-year temporal scale is critical for evaluating and predicting the impact of climate- and human-induced discharge variations on river hydrodynamics. However, achieving such a goal is challenging because of limited surveys of streambed hydraulic roughness, uncertain boundary condition specifications, and high computational costs. We demonstrate that accurate and efficient three-dimensional (3-D) hydrodynamic modeling of natural rivers at 30 km and 5-year scales is feasible using the following three techniques within OpenFOAM, an open-source computational fluid dynamics platform: (1) generating a distributed hydraulic roughness field for the streambed by integrating water-stage observation data, a rough wall theory, and a local roughness optimization and adjustment strategy; (2) prescribing the boundary condition for the inflow and outflow by integrating precomputed results of a one-dimensional (1-D) hydraulic model with the 3-D model; and (3) reducing computational time using multiple parallel runs constrained by 1-D inflow and outflow boundary conditions. Streamflow modeling for a 30 km long reach in the Columbia River (CR) over 58 months can be achieved in less than 6 d using 1.1 million CPU hours. The mean error between the modeled and the observed water stages for our simulated CR reach ranges from −16 to 9 cm (equivalent to approximately ±7 % relative to the average water depth) at seven locations during most of the years between 2011 and 2019. We can reproduce the velocity distribution measured by the acoustic Doppler current profiler (ADCP). The correlation coefficients of the depth-averaged velocity between the model and ADCP measurements are in the range between 0.71 and 0.83 at 75 % of the survey cross sections. With the validated model, we further show that the relative importance of dynamic pressure versus hydrostatic pressure varies with discharge variations and topography heterogeneity. Given the model's high accuracy and computational efficiency, the model framework provides a generic approach to evaluate and predict the impacts of climate- and human-induced discharge variations on river hydrodynamics at tens-of-kilometers and decadal scales.

58 GEOSCIENCES↗

Predicting the liquefaction phenomena from shear velocity profiling: Empirical approach to 6.3 Mw, May 2006 Yogyakarta earthquake

The liquefactions phenomena have been reported after a shocking 6.5Mw earthquake hit Yogyakarta province in the morning at 27 May 2006. Several researchers have reported the damage, casualties, and soil failure due to the quake, including the mapping and analyzing the liquefaction phenomena. Most of them based on SPT test. The study try to draw the liquefaction susceptibility by means the shear velocity profiling using modified Multichannel Analysis of Surface Waves (MASW). This paper is a preliminary report by using only several measured MASW points. The study built 8-channel seismic data logger with 4.5 Hz geophones for this purpose. Several different offsets used to record the high and low frequencies of surface waves. The phase-velocity diagrams were stacked in the frequency domain rather than in time domain, for a clearer and easier dispersion curve picking. All codes are implementing in Matlab. From these procedures, shear velocity profiling was collected beneath each geophone’s spread. By mapping the minimum depth of shallow water table, calculating PGA with soil classification, using empirical formula for saturated soil weight from shear velocity profile, and calculating CRR and CSR at every depth, the liquefaction characteristic can be identify in every layer. From several acquired data, a liquefiable potential at some depth below water table was obtained.

58 GEOSCIENCES↗

Subsoil Potassium in Central Iowa Soils: Status and Future Challenges

A reevaluation of plant-available K within central Iowa soils is needed, especially if crop residues are harvested for animal feed or cellulosic feedstock. This study evaluated plant-available K concentrations to depths of 120 cm (n = 2433) within soil profiles at 10 experimental sites. Data from 0- to 5-, 5- to 15-, 0- to 15-, 15- to 30-, 30- to 60-, 60- to 90-, and 90- to 120-cm depths were compiled and evaluated. Based on over 400 samples collected from each depth increment below 15 cm, a reference value of 100 mg kg –1 appears common for central Iowa subsoils. Sixty-four percent of all samples had soil-test K levels below the 120 mg kg –1 threshold for very low nutrient status for crop production in Iowa. Only 28% of surface soil samples (<15-cm depth) were considered to have at least optimum nutrient status with concentrations greater than 160 mg kg –1 . As K is not an environmentally sensitive nutrient, its management in central Iowa soils has generally been neglected in recent years, particularly when compared with N and P management initiatives. Building awareness of soil K profile concentrations, rather than focusing only on surface concentrations, will be necessary to meet nutrient requirements for 21st century agricultural production.

54 ENVIRONMENTAL SCIENCES↗

OBSERVATIONS AND MODELING OF H{sub 2} FLUORESCENCE WITH PARTIAL FREQUENCY REDISTRIBUTION IN GIANT PLANET ATMOSPHERES

Partial frequency redistribution (PRD), describing the formation of the line profile, has negligible observational effects for optical depths smaller than {approx}10{sup 3}, at the resolving power of most current instruments. However, when the spectral resolution is sufficiently high, PRD modeling becomes essential in interpreting the line shapes and determining the total line fluxes. We demonstrate the effects of PRD on the H{sub 2} line profiles observed at high spectral resolution by the Far-Ultraviolet Spectroscopic Explorer (FUSE) in the atmospheres of Jupiter and Saturn. In these spectra, the asymmetric shapes of the lines in the Lyman (v''-6) progression pumped by the solar Ly{beta} are explained by coherent scattering of the photons in the line wings. We introduce a simple computational approximation to mitigate the numerical difficulties of radiative transfer with PRD and show that it reproduces the exact radiative transfer solution to better than 10%. The lines predicted by our radiative transfer model with PRD, including the H{sub 2} density and temperature distribution as a function of height in the atmosphere, are in agreement with the line profiles observed by FUSE. We discuss the observational consequences of PRD and show that this computational method also allows us to include PRD in modeling the continuum pumped H{sub 2} fluorescence treating about 4000 lines simultaneously.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of zinc oxide thin film using atomic force microscopy and optimized X-ray reflectivity by genetic algorithm

For the nanostructured thin films, the study of surface physical parameters is often of crucial importance. For example, the transport properties of ZnO thin film are strongly affected by the geometry of this film. In this study sol—gel ZnO thin film was spin coated on glass substrate. The inverse problem of thin film characterization is formulated as a parameter identification problem in which a set of parameters corresponding to the thin film property can be found by minimizing fitness functions formulated using theoretical and experimental X-ray reflectivity. Atomic force microscopy (AFM) measurements used as an independent procedure for extracting structural parameters of the film and accurate interpretation of X-ray reflectivity data. After applying Fractal calculations on the AFM measured data the Genetic algorithm (GA) method was applied for extracting other important structural parameters. Optimization of specular X-ray reflectivity by GA method gives information along the depth such as thickness, roughness, and electron density profile of layers in the film.

36 MATERIALS SCIENCE↗

SU-F-T-216: Evaluating Dosimetry Accuracy of a Treatment Planning System On Small Proton Fields

Purpose: This study is aiming to identify the smallest field size for which a treatment planning system (TPS) can accurately calculate the relative dose distribution. The finding would be used as a guideline to choose the smallest proton field for clinical treatment. Methods: Mevion S250™ double scattering proton delivery system and Eclipse™ TPS (Varian) with pencil beam convolution (PBC) dose algorithm were used in this study. Square sized fields of 1 cm, 2 cm, 3 cm, 4 cm, 5 cm, and 10 cm were planned on a cubical water phantom with iso-center placed at 10 cm depth. All beams used the same proton beam option: range 15 cm and modulation 10 cm. Dose in water was calculated without any compensator. Gafchromic™ EBT3 film and diode detectors were used to measure the central axis dose distribution and lateral dose profiles at 5 cm, 10 cm, and 14 cm depth. Results: The preliminary film measurement shows good agreement between Eclipse calculated lateral dose profiles for all tested field sizes. The differences on full width half maximum were ≤ 1 mm while the differences on the penumbras were between 1 mm and 2 mm between Eclipse and film. For the depth dose, Eclipse results matched well with film measurements for field sizes down to 2 cm{sup 2}. With smaller field size of 1 cm{sup 2}, Eclipse was able to predict the decreasing of SOBP due to the lack of lateral charged particle equilibrium in depth. However, it did not match the film measurement. Diode measurement results will be available at the time of presentation. Conclusion: The PBC dose algorithm in Eclipse can accurately calculate relative dose distribution in double scattered proton system for field size down to 2 cm{sup 2}.

60 APPLIED LIFE SCIENCES↗

SU-E-T-52: Beam Data Comparison for 20 Linear Accelerators in One Network

Purpose: To compare photon beam data for the 20 Varian linear accelerators (TrueBeam, iX, and EX models) in use at five centers in the same network with the intent to model with one set of beam data in Eclipsec. Methods: Varian linear accelerators, TrueBeam (3), 21 EX, iX, and Trilogy (14), and 6 EX (3), installed between 1999 and 2014 have their 6 MV and 15 MV x-ray beams reevaluated. Full commissioning, including output factors (St), percent depth doses (PDD), and off-axis profiles, was recently performed for a TrueBeam with a cc04 ion chamber in an IBA Blue phantom. Similarly, a subset of beam data for each of the other accelerators was measured recently as follows: for 3×3, 10×10, and 30×30 cm{sup 2} field sizes, flatness and penumbra (80–20%) were measured at dmax and 10 cm depths, PDD were measured at 10 and 20 cm depths, and St were measured at 5 cm depth. Measurement results for all machines were compared. Results: For 15 high-energy (6 and 15 MV) and 3 low-energy machines (6MV only): 1) PDD agreed within 1.4% at 10 and 20 cm depths; 2) penumbra agreed within 1.0 mm at dmax and 10 cm depths; 3) flatness was within 1.3% at dmax and 10 cm depths; and 4) with exception of the three low energy machines, output factors were within 1.1% and 0.5% for 3×3 and 30×30 cm{sup 2}, respectively. Measurement uncertainty, not quantified here, accounts for some of these differences. Conclusion: Measured beam data from 15 high-energy Varian linacs are consistent enough that they can be classified using one beam data set in Eclipse. Two additional high-energy machines are removed from this group until their data are further confirmed. Three low-energy machines will be in a separate class based upon differences in output factors (St)

07 ISOTOPE AND RADIATION SOURCES↗

Time and space resolved current density mapping in three dimensions using magnetic field probe array in a high voltage coaxial gap

We present an experimental analysis of the symmetry of current density in a coaxial geometry, diagnosed using a magnetic field probe array and calculations of the Fowler-Nordheim enhancement factor. Data were collected on the coaxial gap breakdown device (240 A, 25 kV, 150 ns, ~0.1 Hz), and data from experiments using 2 different gap sizes and different penetration depths are compared over runs comprising 50 shots for each case. The magnetic field probe array quantifies the distribution of current density at three axial locations, on either sides of a vacuum breakdown, and tracks the evolution with time and space. The results show asymmetries in current density, which can be influenced by changes in the gap size and the penetration depth (of the center electrode into the outer electrode). For smaller gap sizes (400 μm), symmetric current profiles were not observed, and the change in the penetration depth changes both the symmetric behavior of the current density and the enhancement factor. For larger gaps (900 μm), current densities were typically more uniform and less influenced by the penetration depth, which is reflected in the enhancement factor values. Furthermore it is possible that the change in inductance caused by the localization of current densities plays a role in the observed behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction factors for saturation effects in white light and laser absorption spectroscopy for application to low pressure plasmas

In white light absorption spectroscopy, the broadening of the absorption signal due to the apparatus profile of the spectrometer may lead to an underestimation of the determined density as one measures an apparent optical depth. This is in particular true for high optical depth where saturation effects of the transmitted intensity occur. Provided that the line profile of the absorption line is known, the apparent optical depth effect can be accounted for by introducing a correction factor. The impact of the saturation and the approach of considering the effect are demonstrated for argon and indium lines in low pressure plasmas where correction factors of one order of magnitude or even higher are reached very easily. For the indium line, the hyperfine splitting has been taken into account. In laser absorption, the line profile is resolved. However, the weak but rather broad background emission of the laser diode can cause a saturation signal at the photo diode resulting also in an underestimation of the density obtained from the analysis. It is shown that this can be taken into account by fitting the theoretical line profile to the measured absorption signal which yields also a correction factor. The method is introduced and demonstrated at the example of the cesium resonance line including the hyperfine splitting. Typical correction factors around two are obtained for the cesium ground state density at conditions of a low pressure negative hydrogen ion source in which cesium is evaporated to enhance the negative ion production.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-T-428: An Optimization-Based Commissioning Tool for Finite Size Pencil Beam Dose Calculations

Purpose: Finite size pencil beam (FSPB) algorithms are commonly used to pre-calculate the beamlet dose distribution for IMRT treatment planning. FSPB commissioning, which usually requires fine tuning of the FSPB kernel parameters, is crucial to the dose calculation accuracy and hence the plan quality. Yet due to the large number of beamlets, FSPB commissioning could be very tedious. This abstract reports an optimization-based FSPB commissioning tool we have developed in MatLab to facilitate the commissioning. Methods: A FSPB dose kernel generally contains two types of parameters: the profile parameters determining the dose kernel shape, and a 2D scaling factors accounting for the longitudinal and off-axis corrections. The former were fitted using the penumbra of a reference broad beam’s dose profile with Levenberg-Marquardt algorithm. Since the dose distribution of a broad beam is simply a linear superposition of the dose kernel of each beamlet calculated with the fitted profile parameters and scaled using the scaling factors, these factors could be determined by solving an optimization problem which minimizes the discrepancies between the calculated dose of broad beams and the reference dose. Results: We have commissioned a FSPB algorithm for three linac photon beams (6MV, 15MV and 6MVFFF). Dose of four field sizes (6*6cm2, 10*10cm2, 15*15cm2 and 20*20cm2) were calculated and compared with the reference dose exported from Eclipse TPS system. For depth dose curves, the differences are less than 1% of maximum dose after maximum dose depth for most cases. For lateral dose profiles, the differences are less than 2% of central dose at inner-beam regions. The differences of the output factors are within 1% for all the three beams. Conclusion: We have developed an optimization-based commissioning tool for FSPB algorithms to facilitate the commissioning, providing sufficient accuracy of beamlet dose calculation for IMRT optimization.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-359: Measurement of Various Metrics to Determine Changes in Megavoltage Photon Beam Energy

Purpose: To examine the relationship between photon beam energy and various metrics for energy on the flattened and flattening filter free (FFF) beams generated by the Varian TrueBeam. Methods: Energy changes were accomplished by adjusting the bending magnet current ±10% from the nominal value for the 4, 6, 8, and 10 MV flattened and 6 and 10 MV FFF beams. Profiles were measured for a 30×30 cm{sup 2} field using a 2D ionization chamber array and a 3D water Scanner which was also used to measure PDDs. For flattened beams we compared several energy metrics; PDD at 10 cm depth in water (PDD(10)); the variation over the central 80% of the field (Flat); and the average of the highest reading along each diagonal divided by the CAX value, diagonal normalized flatness (FDN). For FFF beams we examined PDD(10), FDN, and the width of a chosen isodose level in a 30×30 cm{sup 2} field (W(d%)). Results: Changes in PDD(10) were nearly linear with changes in energy for both flattened and FFF beams as were changes in FDN. Changes in W(d%) were also nearly linear with energy for the FFF beams. PDD(10) was not as sensitive to changes in energy compared to the other metrics for either flattened or FFF beams. Flat was not as sensitive to changes in energy compared to FDN for flattened beams and its behavior depends on depth. FDN was the metric that had the highest sensitivity to the changes in energy for flattened beams while W(d%) was the metric that had highest sensitivity to the changes in energy for FFF beams. Conclusions: The metric FDN was found to be most sensitive to energy changes for flattened beams, while the W(d%) was most sensitive to energy changes for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗

Response of Strontium Titanate to Ion and Electron Irradiation

Response of strontium titanate (SrTiO3) to ion and electron irradiation is studied at room temperature. For an accurate energy to depth conversion and a better determination of ion-induced disorder profile from Rutherford backscattering spectrometry measurement, a detailed iterative procedure is described and applied to ion channeling spectra to determine the dechanneling yield and the disorder profiles for the Sr and Ti sublattices. The result shows a large underestimation in disorder depth, ~ 40% at the damage peak, which indicates a large overestimation of the electronic stopping power for 1.0 MeV Au ions in SrTiO3 predicted by the SRIM (Stopping and Range of Ions in Matter) code. Overestimation of heavy ion stopping power may lead to an overestimation of the critical dose for amorphization. The current study also demonstrates possible ionization effects in SrTiO3 under ion and electron irradiation. Pre-amorphized SrTiO3 exhibits strong ionization-induced epitaxial recovery at the amorphous/crystalline interface under electron irradiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-J-12: Dosimetrical Characteristics of a 2.5 MV Megavoltage Photon Beam

Purpose: To evaluate the accuracy of modeling scatter factor (SF) and primary off-axis ratio (POAR) for 2.5 MV megavoltage photon beams using an empirical model, which can be used as a dose calculation model for low energy EPID imaging. Methods: Scatter photon parameters were calculated for 2.5 MV photon beam from a Varian TrueBeam by fitting the product of depth dose, PDD, and the phantom scatter factor, Sp, for a range of square field sizes between 2 and 40 cm and depths between 0 and 30 cm. The model is then applied to off-axis profiles measured for a slit field (3cm ×35 cm) for 5 depths: 0.6, 5, 10, and 20, 30 cm. Primary off-axis ratio (POAR) values were determined based on the fitting to data using the empirical model. Results: The fitting to PDD*Sp has a maximum error of 14%, mostly near surface, where backscattering of photons dominate and has a standard deviation of 4.7%. The attenuation coefficient and beam-hardening coefficient of the beam is determined to be 0.095 1/cm and 0.0038 1/cm, respectively. POAR for 2.5 MV has a peak in the center, corresponding to a beam without sufficient material to flatten the beam. Conclusion: This work illustrates a deficiency of the current empirical model to fit SF for a 2.5 MV photon beams. Most of the errors are near the surface region and an improved model that incorporate better modeling of backscattering can be developed to improve the model accuracy.

60 APPLIED LIFE SCIENCES↗

DISCOVERY OF CARBON RADIO RECOMBINATION LINES IN M82

Carbon radio recombination lines (RRLs) at low frequencies (≲ 500 MHz) trace the cold, diffuse phase of the interstellar medium, which is otherwise difficult to observe. We present the detection of carbon RRLs in absorption in M82 with the Low Frequency Array in the frequency range of 48-64 MHz. This is the first extragalactic detection of RRLs from a species other than hydrogen, and below 1 GHz. Since the carbon RRLs are not detected individually, we cross-correlated the observed spectrum with a template spectrum of carbon RRLs to determine a radial velocity of 219 km s{sup –1}. Using this radial velocity, we stack 22 carbon-α transitions from quantum levels n = 468-508 to achieve an 8.5σ detection. The absorption line profile exhibits a narrow feature with peak optical depth of 3 × 10{sup –3} and FWHM of 31 km s{sup –1}. Closer inspection suggests that the narrow feature is superimposed on a broad, shallow component. The total line profile appears to be correlated with the 21 cm H I line profile reconstructed from H I absorption in the direction of supernova remnants in the nucleus. The narrow width and centroid velocity of the feature suggests that it is associated with the nuclear starburst region. It is therefore likely that the carbon RRLs are associated with cold atomic gas in the direction of the nucleus of M82.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-149: Electron Beam Profile Differences Between Elekta MLCi2 and Elekta Agility Treatment Heads

Purpose: To report and investigate observed differences in electron beam profiles at various energies/applicators between Elekta MLCi2 and Agility treatment head on Elekta Infinity LINAC Methods: When we upgraded from MLCi2 to Agility on one of our Elekta Infinity LINAC's, electron beam PDDs and profiles were acquired for comparison purpose. All clinical electron energies (6/9/12/15/12/18 MeV) and electron applicators (6/10/14/20/25 square) were included in measurement. PDDs were acquired at 100 SSD in water (PTW MP3 water tank) with a plane-parallel ion chamber (PTW Roos). X and Y Profiles were acquired using IC Profiler (Sun Nuclear Corp.) at 1cm and maximum PDD depths (water equivalent). Results: All PDD curves match very well between MLCi2 and Agility treatment head. However, some significant differences on electron profiles were found. On Agility, even after increasing the default auto-tracking offset values for backup diaphragms in Y and MLC in X by 2.8 cm (the maximum allowed change is 3.0 cm), electron profiles still have rounder shoulders comparing to corresponding MLCi2 profiles. This difference is significantly more pronounced at larger applicators (20 and 25 square), for all electron energies. Conclusion: The significant design change between MLCi2 and Agility beam limiting device seems to affect exit electron beam profiles. In IEC1217 X direction, the main change on Agility is the removal of the original MLCi2 X backup diaphragms and replacing it with MLC leaves; In Y direction, the main change is the radius and materials on Y backup diaphragms.

07 ISOTOPE AND RADIATION SOURCES↗