At least 1,297 records · Page 72

Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads

Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.

36 MATERIALS SCIENCE↗

Results of a landing gear loads test using a 0.0405-scale model (16-0) of the space shuttle orbiter in the Rockwell International NAAL wind tunnel (OA163B), volume 1

Aerodynamic loads on a sting mounted 0.045-scale representation of the 140C outer mold line space shuttle orbiter configuration were measured to verify orbiter landing gear system pressure loading and hinge moment levels. Pressure, force, and hinge moment data, recorded over smaller increments of the landing gear deployment schedule to insure data accuracy and to investigate the effects of asymmetric gear deployment on all parameters, are presented. Tests were conducted at a Mach number of 0.17, and freestream dynamic pressure of 42.5 psf, and a Reynolds number per unit length of 1.2 million foot. Angle of attack variation was -2 to 10 degrees while angles of sideslip varied from -5 to 5 degrees.

Mennell, R. C.↗

Double noding technique for mixed mode crack propagation studies

A simple dynamic finite element algorithm for analyzing a propagating mixed mode crack tip is presented. A double noding technique, which can be easily incorporated into existing dynamic finite element codes, is used together with a corrected J integral to extract modes I and II dynamic stress intensity factors of a propagating crack. The utility of the procedure is demonstrated by analyzing test problems involving a mode I central crack propagating in a plate subjected to uniaxial tension, a mixed mode I and II stationary, slanted central crack in a plate subjected to uniaxial impact loading, and a mixed mode I and II extending, slanted single edge crack in a plate subjected to uniaxial tension.

Liaw, B. M.↗

Ames Research Center Life Sciences Payload Project for Spacelab Mission 3

The Research Animal Holding Facility, developed to support rodent and squirrel monkey animal husbandry in the Spacelab environment, is to be tested during the Spacelab Mission 3 flight. The configuration and function of the payload hardware elements, the assembly and test program, the operational rationale, and the scientific approach of this mission are examined. Topics covered include animal life support systems, the squirrel monkey restraint, the camera-mirror system, the dynamic environment measurement system, the biotelemetry system, and the ground support equipment. Consideration is also given to animal pretests, loading the animals during their 12 hour light cycle, and animal early recovery after landing. This mission will be the first time that relatively large samples of monkeys and rats will be flown in space and also cared for and observed by man.

Callahan, P. X.↗

Double noding technique for mixed mode crack propagation studies

A simple dynamic finite element algorithm for analyzing a propagating mixed mode crack tip is presented. A double noding technique, which can be easily incorporated into existing dynamic finite element codes, is used together with a corrected J integral to extract modes I and II dynamic stress intensity factors of a propagating crack. The utility of the procedure is demonstrated by analyzing test problems involving a mode I central crack propagating in a plate subjected to uniaxial tension, a mixed mode I and II stationary, slanted central crack in a plate subjected to uniaxial impact loading, and a mixed mode I and II extending, slanted single edge crack in a plate subjected to uniaxial tension. Previously announced in STAR as N83-13491

Liaw, B. M.↗

Development of gas-to-gas lift pad dynamic seals, volumes 1 and 2

Dynamic tests were performed on self acting (hydrodynamic) carbon face rotary shaft seals to assess their potential, relative to presently used labyrinth seals, for improving performance of aircraft gas turbine engines by reducing air leakage flow rate at compressor end seal locations. Three self acting bearing configurations, designed to supply load support at the interface of the stationary carbon seal and rotating seal race, were tested. Two configurations, the shrouded taper and shrouded flat step, were incorporated on the face of the stationary carbon seal element. The third configuration, inward pumping spiral grooves, was incorporated on the hard faced surface of the rotating seal race. Test results demonstrated seal leakage air flow rates from 75 to 95% lower that can be achieved with best state-of-the-art labyrinth designs and led to identification of the need for a more geometrically stable seal design configuration which is presently being manufactured for subsequent test evaluation.

Pope, A. N.↗

Wind-tunnel evaluation of an advanced main-rotor blade design for a utility-class helicopter

An investigation was conducted in the Langley Transonic Dynamics Tunnel to evaluate differences between an existing utility-class main-rotor blade and an advanced-design main-rotor blade. The two rotor blade designs were compared with regard to rotor performance oscillatory pitch-link loads, and 4-per-rev vertical fixed-system loads. Tests were conducted in hover and over a range of simulated full-scale gross weights and density altitude conditions at advance ratios from 0.15 to 0.40. Results indicate that the advanced blade design offers performance improvements over the baseline blade in both hover and forward flight. Pitch-link oscillatory loads for the baseline rotor were more sensitive to the test conditions than those of the advanced rotor. The 4-per-rev vertical fixed-system load produced by the advanced blade was larger than that produced by the baseline blade at all test conditions.

Yeager, William T., Jr.↗

The HL-20 Personnel Launch System

A lifting-body approach to the design of a personnel launch system spacecraft for Space Station crew rotation missions is presented. Recent study findings in the areas of wind tunnel tests, landing dynamics, handling qualities, and abort are summarized. HL-20, which is designed for safe and reliable operations, has improved operability, maintainability, and affordability as compared to current manned transportation operations. The high lift-to-drag ratio of the HL-20 provides significant advantages in reduced g-loads during entry, high crossrange capability, ability to fly to landing sites over an extensive part of the earth, and multiple landing opportunities per day at specific landing sites. Pilot ratings of the flying qualities are at level 1 on the Cooper-Harper scale. Attention is also given to a streamlined management approach to HL-20 PLS development and operations which are presently under study.

Talay, Theodore A.↗

Blood Analyzer

In the 1970's, NASA provided funding for development of an automatic blood analyzer for Skylab at the Oak Ridge National Laboratory (ORNL). ORNL devised "dynamic loading," which employed a spinning rotor to load, transfer, and analyze blood samples by centrifugal processing. A refined, commercial version of the system was produced by ABAXIS and is marketed as portable ABAXIS MiniLab MCA. Used in a doctor's office, the equipment can perform 80 to 100 chemical blood tests on a single drop of blood and report results in five minutes. Further development is anticipated.

Source record↗

Vestibular and Somatosensory Covergence in Postural Equilibrium Control: Insights from Spaceflight and Bed Rest Studies

The goal of the Functional Task Test study is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. We are currently conducting studies on both International Space Station (ISS) astronauts experiencing up to 6 months of microgravity and subjects experiencing 70 days of 6head-down bed-rest as an analog for space flight. Bed-rest provides the opportunity for us to investigate the role of prolonged axial body unloading in isolation from the other physiological effects produced by exposure to the microgravity environment of space flight. This allows us to parse out the contribution of the body unloading somatosensory component on functional performance. Both ISS crewmembers and bed-rest subjects were tested using a protocol that evaluated functional performance along with tests of postural and locomotor control before and after space flight and bed-rest, respectively. Functional tests included ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall, and object translation tasks. Astronauts were tested three times before flight, and on 1, 6, and 30 days after landing. Bed-rest subjects were tested three times before bed-rest and immediately after getting up from bed-rest as well as 1, 6, and 12 days after re-ambulation. A comparison of bed-rest and space flight data showed a significant concordance in performance changes across all functional tests. Tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability showed less reduction in performance. Results indicate that body unloading resulting from prolonged bed-rest impacts functional performance particularly for tests with a greater requirement for postural equilibrium control. These changes in functional performance were paralleled by similar decrement in tests designed to specifically assess postural equilibrium and dynamic gait control. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. These data also support the concept that space flight may cause central adaptation of converging body-load somatosensory and vestibular input during gravitational transitions.

Mulavara, A. P.↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗

Insights from a workplace SARS-CoV-2 specimen collection program, with genomes placed into global sequence phylogeny

In 2020, the Department of Energy established the National Virtual Biotechnology Laboratory (NVBL) to address key challenges associated with COVID-19. As part of that effort, Pacific Northwest National Laboratory (PNNL) established a capability to collect and analyze specimens from employees who self-reported symptoms consistent with the disease. During the spring and fall of 2021, 688 specimens were screened for SARS-CoV-2, with 64 (9.3%) testing positive using reverse-transcriptase quantitative PCR (RT-qPCR). Of these, 36 samples were released for research. All 36 positive samples released for research were sequenced and genotyped. Here, the relationship between patient age and viral load as measured by Ct values was measured and determined to be only weakly significant. Consensus sequences for each sample were placed into a global phylogeny and transmission dynamics were investigated, revealing that the closest relative for many samples was from outside of Washington state, indicating mixing of viral pools within geographic regions.

59 BASIC BIOLOGICAL SCIENCES↗

An Overview of the Guided Parafoil System Derived from X-38 Experience

The NASA Johnson Space Center built a 4200 sq ft parafoil for the U.S. Army Natick Soldier Center to demonstrate autonomous flight using a guided parafoil system to deliver 10,000 lbs of useable payload. The parafoil's design was based upon that developed during the X-38 program. The drop test payload consisted of a standard 20-foot Type V airdrop platform, a standard 12-foot weight tub, a 60 ft drogue parachute, a 4200 ft2 parafoil, an instrumentation system, and a Guidance, Navigation, and Control (GN&C) system. Instrumentation installed on the load was used to gather data to validate simulation models and preflight loads predictions and to perform post flight trajectory and performance reconstructions. The GN&C system, developed during NASA's X-38 program, consisted of a flight computer, modems for uplink commands and downlink data, a compass, laser altimeter, and two winches. The winches were used to steer the parafoil and to perform the dynamic flare maneuver for a soft landing. The laser was used to initiate the flare. The GN&C software was originally provided to NASA by the European Space Agency. NASA incorporated further software refinements based upon the X-38 flight test results. Three full-scale drop tests were conducted, with the third being performed during the Precision Airdrop Technology Conference and Demonstration (PATCAD) Conference at the U.S. Army Yuma Proving Ground (YPG) in November of 2003. For the PATCAD demonstration, the parafoil and GN&C software and hardware performed well, concluding with a good flare and the smallest miss distance ever experienced in NASA's parafoil drop test program. This paper describes the 4200 sq ft parafoil system, simulation results, and the results of the drop tests.

Stein, Jenny M.↗

Finite element analyses of continuous filament ties for masonry applications : final report for the Arquin Corporation.

Finite-element analyses were performed to simulate the response of a hypothetical vertical masonry wall subject to different lateral loads with and without continuous horizontal filament ties laid between rows of concrete blocks. A static loading analysis and cost comparison were also performed to evaluate optimal materials and designs for the spacers affixed to the filaments. Results showed that polypropylene, ABS, and polyethylene (high density) were suitable materials for the spacers based on performance and cost, and the short T-spacer design was optimal based on its performance and functionality. Simulations of vertical walls subject to static loads representing 100 mph winds (0.2 psi) and a seismic event (0.66 psi) showed that the simulated walls performed similarly and adequately when subject to these loads with and without the ties. Additional simulations and tests are required to assess the performance of actual walls with and without the ties under greater loads and more realistic conditions (e.g., cracks, non-linear response).

42 ENGINEERING↗

Sugar loading is not required for phloem sap flow in maize plants

We report phloem transport of photoassimilates from leaves to non-photosynthetic organs, such as the root and shoot apices and reproductive organs, is crucial to plant growth and yield. For nearly 90 years, evidence has been generally consistent with the theory of a pressure-flow mechanism of phloem transport. Central to this hypothesis is the loading of osmolytes, principally sugars, into the phloem to generate the osmotic pressure that propels bulk flow. Here we used genetic and light manipulations to test whether sugar import into the phloem is required as the driving force for phloem sap flow. Using carbon-11 radiotracer, we show that a maize sucrose transporter1 (sut1) loss-of-function mutant has severely reduced export of carbon from photosynthetic leaves (only ~4% of the wild type level). Yet, the mutant remarkably maintains phloem pressure at ~100% and sap flow speeds at ~50–75% of those of wild type. Potassium (K+) abundance in the phloem was elevated in sut1 mutant leaves. Fluid dynamic modelling supports the conclusion that increased K+ loading compensated for decreased sucrose loading to maintain phloem pressure, and thereby maintained phloem transport via the pressure-flow mechanism. Furthermore, these results suggest that sap flow and transport of other phloem-mobile nutrients and signalling molecules could be regulated independently of sugar loading into the phloem, potentially influencing carbon–nutrient homoeostasis and the distribution of signalling molecules in plants encountering different environmental conditions.

36 MATERIALS SCIENCE↗

Reinforcement Learning-based Output Structured Feedback for Distributed Multi-Area Power System Frequency Control

Load frequency control (LFC) is a key factor to maintain the stable frequency in multi-area power systems. As the modern power systems evolve from centralized to decentralized paradigm, LFC needs to consider the decentralized scheme that considers limited information from the information-exchange graph for the generator control of each interconnected area. This paper aims to solve a data-driven constrained LQR problem with mean-variance risk constraints and output structured feedback, and applies this framework to solve the LFC problem in multi-area power systems. By reformulating the constrained optimization problem into a minimax problem, the stochastic gradient descent max-oracle (SGDmax) algorithm with zero-order policy gradient (ZOPG) is adopted to find the optimal feedback gain from the learning, while guaranteeing the convergence. In addition, to improve the adaptation of the proposed learning method to new or varying models, we construct an emulator grid that approximates the dynamics of a physical grid and performs training based on this model. Once the feedback gain is obtained from the emulator grid, it is applied to the physical grid with a robustness test to check whether the controller from the approximated emulator applies to the actual system. Numerical tests show that the obtained feedback controller can successfully control the frequency of each area, while mitigating the uncertainty from the loads, with reliable robustness that ensures the adaptability of the obtained feedback gain to the actual physical grid.

Kwon, Kyung-bin↗

Model Fidelity Study of Dynamic Transient Loads in a Wind Turbine Gearbox: Preprint

Transient events cause high loads in the drivetrain components so measuring and calculating these loads can improve confidence in drivetrain design. This paper studies the Gearbox Reliability Collaborative 750kW wind turbine gearbox response during transient events using a combined experimental and modeling approach. The transient events include emergency shut-downs and start-ups measured during a field testing period in 2009. The drivetrain model is established in the multibody simulation tool Simpack. A detailed study of modeling fidelity required for accurate load prediction is performed and results are compared against measured loads. A high fidelity model that includes shaft and housing flexibility and accurate bearing stiffnesses is important for the higher-speed stage bearing loads. Each of the transient events has different modeling requirements.

17 WIND ENERGY↗

Dynamic Deformation in Nuclear Graphite and Underlying Mechanisms

Time-dependent deformation in nuclear graphite is influenced by the creation and migration of radiation-induced defects in the reactor environment. This study investigates the role of pre-existing defects such as point defect clusters and Mrozowski cracks in nuclear graphite IG-110. Separate specimens were irradiated with a 2.8 MeV Au 2+ beam with a fluence of 4.38 × 10 14 cm −2 and an 8 MeV C 2+ beam with a fluence of 1.24 × 10 16 cm −2 . Microscopic specimens were either mechanically loaded inside a transmission electron microscope (TEM) or subjected to ex situ indentation-based creep loading. In situ TEM tests showed significant plasticity in regions highly localized around the Mrozowski cracks, resembling slip or ripplocation bands. Slip bands were also seen near regions without pre-existing defects but at very high stresses. Ex situ self-ion irradiation embrittled the specimens and decreased the creep displacement and rate, while heavy ion irradiation resulted in the opposite behavior. We hypothesize that the large-sized gold ions (compared to the carbon atoms) induced interplanar swelling as well as cross-plane channels for increased defect mobility. These findings illustrate the role of pre-existing defects in the dynamic relaxation of stresses during irradiation and the need for more studies into the radiation environment’s impact on the mechanical response of nuclear graphite.

creep deformation↗