Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Representativeness and repeatability of microenvironmental personal and head exposures to radio-frequency electromagnetic fields

Highlights: • First time assessment of head exposure to RF-EMF in uncontrolled environments, in 15 microenvironments in Melbourne, Australia. • We show that our measurement protocol is repeatable over time. • We show that the paths selected in our protocol are representative for the larger areas in which they are defined. • Exposure to RF-EMF is higher in more dense urban areas than in less populated suburban areas in the outskirts of the city. The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r{sup 2} > 0.66 for two paths in the same area) and a high repeatability over time (r{sup 2} > 0.87 for repetitions of the same path). The median head exposure in the 900 MHz downlink band ranged between 0.06 V/m and 0.31 V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r{sup 2} < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89 V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05 V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Analysis of the Durability of PEM FC Membrane Electrode Assemblies in Automotive Applications through the Fundamental Understanding of Membrane and MEA Degradation Pathways

The Project focused on mitigation of degradation processes on membrane electrode assemblies. The approach was to develop a model to improve understanding of the mechanisms, and to use it to focus mitigation strategies. The detailed effects of various accelerated stress tests (ASTs) were evaluated to determine the best subset to use in model development. A combination of ASTs developed by the Fuel Cell Commercialization Conference of Japan and the Fuel Cell Tech Team were selected for use. The ASTs were compared by measuring effects on performance, running in-situ diagnostics, and performing microscopic analyses of the membrane electrode assemblies after the stress tests were complete. Nissan ran FCCJ AST protocols and performed in situ and ex-situ electrochemical testing. DuPont ran FCTT and USFCC AST protocols, performed scanning and transmission electron microscopy and ran in-situ electrochemical tests. Other ex-situ testing was performed by IIT, along with much of the data analysis and model development. These tests were then modified to generate time-dependent data of the degradation mechanisms. Three different catalyst types and four membrane variants were then used to generate data for a theoretically-based degradation model. An important part of the approach was to use commercially available materials in the electrodes and membranes made in scalable semiworks processes rather than lab-based materials. This constraint ensured all materials would be practicable for full-scale testing. The initial model for the electrode layer was tested for internal consistency and agreement with the data. A Java-based computer application was developed to analyze the time-dependent AST data using polarization curves with four different cathode gas feeds and generate model parameters. Data showed very good reproducibility and good consistency as cathode catalyst loadings were varied. At the point of termination of the project, a basic electrode model was in hand with several areas identified for improvement. Time dependence and the membrane portion of the model were not addressed due to cancellation of Phase 2 of the Project.

08 HYDROGEN↗

Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients

AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Value of Metabolic Tumor Volume and Velocity in Predicting Head-and-Neck Cancer Outcomes

Purpose: We previously showed that metabolic tumor volume (MTV) on positron emission tomography-computed tomography (PET-CT) predicts for disease recurrence and death in head-and-neck cancer (HNC). We hypothesized that increases in MTV over time would correlate with tumor growth and biology, and would predict outcome. We sought to examine tumor growth over time in serial pretreatment PET-CT scans. Methods and Materials: From 2006 to 2009, 51 patients had two PET-CT scans before receiving HNC treatment. MTV was defined as the tumor volume {>=}50% of maximum SUV (SUV{sub max}). MTV was calculated for the primary tumor, nodal disease, and composite (primary tumor + nodes). MTV and SUV velocity were defined as the change in MTV or SUV{sub max} over time, respectively. Cox regression analyses were used to examine correlations between SUV, MTV velocity, and outcome (disease progression and overall survival). Results: The median follow-up time was 17.5 months. The median time between PET-CT scans was 3 weeks. Unexpectedly, 51% of cases demonstrated a decrease in SUV{sub max} (average, -0.1 cc/week) and MTV (average, -0.3 cc/week) over time. Despite the variability in MTV, primary tumor MTV velocity predicted disease progression (hazard ratio 2.94; p = 0.01) and overall survival (hazard ratio 1.85; p = 0.03). Conclusions: Primary tumor MTV velocity appears to be a better prognostic indicator of disease progression and survival in comparison to nodal MTV velocity. However, substantial variability was found in PET-CT biomarkers between serial scans. Caution should be used when PET-CT biomarkers are integrated into clinical protocols for HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Drug-Eluting Bead TACE Enhance the Local Effect of IRE? Imaging and Histopathological Evaluation in a Porcine Model

Objectives: We conducted an in vivo trial on swine to compare the ablation volumes of irreversible electroporation (IRE) followed by drug-eluting beads transarterial chemoembolization (DEB-TACE) versus IRE only. Materials and Methods: Nine swine underwent CT-guided IRE in one liver lobe and IRE immediately followed by DEB-TACE in a different liver lobe. For DEB-TACE, 100–300 µm beads (DC-Beads{sup ®}) were loaded with 50 mg doxorubicin. For IRE, the NanoKnife{sup ®} was used employing two electrodes according to the vendor’s protocol. Imaging follow-up was performed including CT-based lesion volume assessment using contrast-enhanced CT (venous phase) on days 1, 3, and 7 after the procedure. Three animals were killed for histopathological analysis after each follow-up. Results: Ablation volumes in CT in the IRE + DEB-TACE group were 15.4 ± 10.5 ml on day 1, 8.7 ± 5.6 ml on day 3, and 1.6 ± 0.7 ml on day 7. In the IRE group, the corresponding values were 5.2 ± 5.2 ml on day 1, 1.0 ± 1.2 ml on day 3, and 0.1 ± 0.1 ml on day 7. On day 1 and day 3, ablation volumes of IRE + TACE group were significantly larger than in the IRE group (p < 0.05). 96% of beads were depicted in or around ablative lesions. 69% of these beads were found in the surrounding hemorrhagic infiltration and 31% within the ablative lesion itself. Conclusions: Combination of IRE immediately followed by DEB-TACE resulted in larger ablation volumes compared to IRE alone, suggesting that local efficacy of IRE can be enhanced by post-IRE DEB-TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A feasibility study of using advanced external beam techniques to create a vaginal cuff brachytherapy-like endometrial boost plan

The purpose of this study was to explore the feasibility of using advanced external beam radiation therapy (EBRT) planning techniques for creating plans that could be used as a possible alternative for high-dose rate (HDR) vaginal cuff brachytherapy (VCBT) boost in treating endometrial cancer. The computed tomography (CT) images of a total of 4 female patients who had endometrial cancer treated with HDR-VCBT were selected for this study. A typical HDR-VCBT target volume, 0.5-cm-thick shell volume around the cylinder applicator in the prescribed treatment length was contoured and used as the planning target volume (PTV) in both the HDR VCBT and the EBRT VCBT-like plans. HDR-VCBT plans were made based on the clinical protocol, 6 Gy given at the cylinder surface. The EBRT plans were generated using either a 7-field intensity-modulated radiation therapy (IMRT) or a 2-arc volumetric-modulated arc therapy (VMAT) techniques for different cylinder sizes and treatment lengths, with the prescription dose of 5 Gy. Organs at risk (OARs) such as bladder, femoral heads, rectum, and sigmoid were also contoured and used in dosimetric evaluations. Dose-to-target metrics included mean dose, the dose covering 90% of target volume (D90) and the percentage of target volume covered by 90% of prescription dose (V90 or V13.5 Gy). Dose to OAR metrics included the maximum dose received by 0.1 cc (D0.1cc), 1.0 cc (D1.0cc), and 2.0 cc (D2.0cc) of OARs. These metrics were calculated and compared between all techniques. After the EBRT plans were normalized to achieve a comparable mean dose to target as HDR-VCBT, the EBRT plans were found to have superior target coverage and increased dose homogeneity compared with HDR-VCBT. V90s of EBRT plans were 95%, compared with 50% to 58% of the HDR plans. However, D0.1cc, D1.0cc, and D2.0cc of OARs were 2% to 38% lower in HDR-VCBT than in EBRT. Although HDR-VCBT plans demonstrated superior normal tissue sparing, both EBRT and HDR-VCBT plans produce plans that met clinical dose constraints on normal tissues. Advanced EBRT techniques such as IMRT and VMAT are capable of making plans, which closely resemble HDR-VCBT. Although the doses of OARs are greater in EBRT than in HDR-VCBT, the prescription dose coverage and dose homogeneity of the EBRT plans are greater than that of HDR-VCBT plans at the similar mean dose, and the OAR dose is still acceptable with EBRT plans. The detailed dosimetric approaches are provided in the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating water content in an active landfill with the aid of GPR

Highlights: • Limited information in the literature on the use of GPR to measure in situ water content in a landfill. • Developed GPR method allows measurement of in situ water content in a landfill. • Developed GPR method is appealing to waste management professionals operating landfills. - Abstract: Landfill gas (LFG) receives a great deal of attention due to both negative and positive environmental impacts, global warming and a green energy source, respectively. However, predicting the quantity of LFG generated at a given landfill, whether active or closed is difficult due to the heterogeneities present in waste, and the lack of accurate in situ waste parameters like water content. Accordingly, ground penetrating radar (GPR) was evaluated as a tool for estimating in situ water content. Due to the large degree of subsurface heterogeneity and the electrically conductive clay cap covering landfills, both of which affect the transmission of the electromagnetic pulses, there is much scepticism concerning the use of GPR to quantify in situ water content within a municipal landfill. Two landfills were studied. The first landfill was used to develop the measurement protocols, while the second landfill provided a means of confirming these protocols. GPR measurements were initially completed using the surface GPR approach, but the lack of success led to the use of borehole (BH) GPR. Both zero offset profiling (ZOP) and multiple offset gathers (MOG) modes were tried, with the results indicating that BH GPR using the ZOP mode is the most simple and efficient method to measure in situ water content. The best results were obtained at a separation distance of 2 m, where higher the water content, smaller the effective separation distance. However, an increase in water content did appear to increase the accuracy of the GPR measurements. For the effective separation distance of 2 m at both landfills, the difference between GPR and lab measured water contents were reasonable at 33.9% for the drier landfill and 18.1% for the wetter landfill. Infiltration experiments also showed the potential to measure small increases in water content.

54 ENVIRONMENTAL SCIENCES↗

UrbanScaping: Community Spatial Data Visualization & Analytics

Evaluating the electrification potential of buildings through retrofitting is crucial for reducing carbon emissions and the carbon footprint of built environments. This study leverages the Automatic Building Energy Modeling (AutoBEM) software, integrating the Model America database to create an urban context-based spatial analysis platform for community engagement and development. We selected Camp Hill Borough, PA, as a case study to analyze building-specific energy performance and evaluate the electrification potential of each building by switching to different Heating, Ventilation, and Air Conditioning (HVAC) systems and measurement components. The simulation results generated by the workflow provide retrofitting suggestions to help mitigate the carbon footprint as well as energy saving statistics of buildings. Additionally, the developed web-based interface serves as a community engagement platform, allowing residents to provide feedback and further develop interactive communication protocols. The outcomes of this project offer a baseline for community electrification planning and contribute to the design of low-carbon communities.

Chowdhury, Shovan [ORNL]↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Effects of Rapid High Temperature Cyclic Aging on a Fully-Formulated Lean NOx Trap Catalyst

In this study, high-temperature deactivation of a fully-formulated lean NOx trap (LNT) is investigated with an accelerated aging protocol where accelerated aging is accomplished by rapid temperature cycling and by higher temperatures. Thermal aging is carried out in a bench-flow reactor at nominal temperatures of 700, 800, 900, and 1000 C using an aging cycle consisting of a 130s lean-phase and a 50s rich-phase. After a prescribed number of lean/rich aging cycles, the NOx conversion of the aged LNT is evaluated at 200, 300, and 400 C. The NOx performance is obtained at a GHSV of 30,000 h-1 using an evaluation cycle consisting of a 60s lean-phase and 5s rich-phase. The effects of aging on the LNT washcoat are determined with EPMA, XRD, STEM/EDS, and BET. Aging at 700 and 800 C has a minimal effect on LNT performance and material properties. However, at aging temperatures of 900 and 1000 C reduction in surface area and sintering of PGM particles are observed and result in a drastic reduction in NOx conversion. Additionally, after aging at 900 C and 1000 C the NOx storage medium, BaCO3, is no longer visible in the XRD patterns, even though a Ba-phase identified by EPMA still exists in all aged samples. BaAl2O4 is not identified at any aging temperatures; possibly due to stabilization effects provided by washcoat additives present in this particular LNT.

33 ADVANCED PROPULSION SYSTEMS↗

Repetitive Pediatric Anesthesia in a Non-Hospital Setting

Purpose: Repetitive sedation/anesthesia (S/A) for children receiving fractionated radiation therapy requires induction and recovery daily for several weeks. In the vast majority of cases, this is accomplished in an academic center with direct access to pediatric faculty and facilities in case of an emergency. Proton radiation therapy centers are more frequently free-standing facilities at some distance from specialized pediatric care. This poses a potential dilemma in the case of children requiring anesthesia. Methods and Materials: The records of the Indiana University Health Proton Therapy Center were reviewed for patients requiring anesthesia during proton beam therapy (PBT) between June 1, 2008, and April 12, 2012. Results: A total of 138 children received daily anesthesia during this period. A median of 30 fractions (range, 1-49) was delivered over a median of 43 days (range, 1-74) for a total of 4045 sedation/anesthesia procedures. Three events (0.0074%) occurred, 1 fall from a gurney during anesthesia recovery and 2 aspiration events requiring emergency department evaluation. All 3 children did well. One aspiration patient needed admission to the hospital and mechanical ventilation support. The other patient returned the next day for treatment without issue. The patient who fell was not injured. No patient required cessation of therapy. Conclusions: This is the largest reported series of repetitive pediatric anesthesia in radiation therapy, and the only available data from the proton environment. Strict adherence to rigorous protocols and a well-trained team can safely deliver daily sedation/anesthesia in free-standing proton centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Beam Quality Determination Through Fricke Xylenol Gel Dosimeter

According to the IAEA TRS-398 protocol, a parallel plate ionization chamber is recommended to be used in electron dosimetry. The important dosimetric parameters such as R{sub 100} and R{sub 50}, inferred from the percentage depth dose (PDD) curve, allow to obtain the electron beam average energy at the water phantom surface (material equivalent to the soft tissue). In this work, a chemical dosimeter based on the Fe(II) to Fe(III) oxidation was used to obtain the average energies from electrons beams (from nominal energies of 5, 8 and 10 MeV) and related parameters of R{sub 100}, R{sub 50} and z{sub ref}. These energies obtained through the Fricke Xylenol Gel (FXG) were compared to those with a parallel plate ionization chamber, following the cited protocol, which showed no significant differences. From these measurements one can conclude the FXG applicability for R{sub 100}, R{sub 50} and electron beam average energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

UV-black rutile TiO{sub 2}: An antireflective photocatalytic nanostructure

This work presents an experimental study on the specific quantitative contributions of antireflective and effective surface areas on the photocatalytic and antibacterial properties of rutile TiO{sub 2} nanospikes. They are studied when continuously distributed over the whole surface and when integrated into well-defined microstructures. The nanospikes were produced following MeV ion beam irradiation of bulk rutile TiO{sub 2} single crystals and subsequent chemical etching. The ion beam irradiation generated embedded isolated crystalline nanoparticles inside an etchable amorphous TiO{sub 2} layer, and nanospikes fixed to the not etchable TiO{sub 2} bulk substrate. The produced nanospikes are shown to resist towards aggressive chemical environments and act as an efficient UV antireflective surface. The photocatalytic activity experiments were performed under the ISO 10678:2010 protocol. The photonic and quantum efficiency are reported for the studied samples. The combined micro- and nanostructured surface triples the photonic efficiency compared to the initial flat surface. Results also revealed that the antireflective effect, due to the nanostructuring, is the dominating factor compared to the increase of surface area, for the observed photocatalytic response. The obtained results may be taken as a general strategy to design and precisely evaluate photoactive nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Impact of Forest Seral Stage on use of Ant Communities for Rapid Assessment of Terrestrial Ecosystem Health

Bioassessment evaluates ecosystem health by using the responses of a community of organisms that integrate all aspects of the ecosystem. A variety of bioassessment methods have been applied to aquatic ecosystems; however, terrestrial methods are less advanced. The objective of this study was to examine baseline differences in ant communities at different seral stages from clear cut to mature pine plantation as a precursor to developing a broader terrestrial bioassessment protocol. Comparative sampling was conducted at nine sites having four seral stages: clearcut, 5 year recovery, 15 year recovery, and mature stands. Soil and vegetation data were also collected at each site. Ants were identified to genus. Analysis of the ant data indicated that ants respond strongly to habitat changes that accompany ecological succession in managed pine forests, and both individual genera and ant community structure can be used as indicators of successional change. Ants exhibited relatively high diversity in both early and mature seral stages. High ant diversity in mature seral stages was likely related to conditions on the forest floor favoring litter dwelling and cold climate specialists. While ants may be very useful in identifying environmental stress in managed pine forests, adjustments must be made for seral stage when comparing impacted and unimpacted forests.

54 ENVIRONMENTAL SCIENCES↗

Benchmarking Microscale Ductility Measurements (Final Report of the Project DE-NE0008799)

Conventional macroscale experimentation is generally considered to be straightforward with few limitations. Conversely, micro/nanoscale experimentation presents numerous challenges in loading device design, sample preparation and handling, as well as accurate understanding of grain size and local texture effects on recorded measurements. Despite these challenges, nanopillar compression, MEMs based micro-tension, and nanoindentation approaches have been able to provide fundamental contributions to the understanding of material behavior at small lengthscales. However, the overarching shortcoming of these micro/nanoscale experimentation approaches, is the inability to directly translate measurements evaluated at the nm and µm length scales (e.g., hardness) to macroscale tensile material behavior (i.e., elastic modulus, yield strength, and ductility). The objectives of the proposed study are, 1) to establish best practices for obtaining tensile microscale ductility measurements, and 2) to validate methodologies to for comparing microscale ductility measurements to macroscale ductility measurements. In order to achieve these objectives, a multi-lengthscale, multi-temperature testing protocol and simulation framework are executed first on copper as a model material to validate the following approach, and second on reactor grade Zircaloy-2. Experiments are conducted on specimens extracted from the same test piece to ensure nominally identical grain size and texture from specimens to specimen. Motivated by the need to isolate the contribution of size-effects on obtained mechanical property measurements, specimens are manufactured with thicknesses at the micro- (1-10 µm), meso- (10-100's µm), and macroscales (sub-sized ASTM E8). In-situ full-field deformation techniques (scanning electron microscopy (SEM) grid methods and optical DIC) are incorporated into testing at each specimen length-scale to capture plasticity localization and evolution. Experimental testing for all specimens is conducted at both room temperature and elevated temperatures to probe the role of thermal activation on plastic deformation accommodation processes. Simulation efforts focus on examining the mechanical behavior of microscale specimens using a finite element approach with explicitly resolved grain morphologies, and an embedded crystal plasticity model. The cost-efficient implementation method allows for the modeling of a statistically significant number of both real (i.e., digital twin) and generated microstructures to obtain an understanding of the interrelationships between specimen microstructure and geometric variables (grain size, texture, specimen geometry, etc.) on microscale mechanical behavior.

36 MATERIALS SCIENCE↗

Reining in an Agentic Harness for High Energy Physics

Agentic systems now address tasks across theoretical, phenomenological, and experimental high energy physics (HEP), but their scientific capabilities remain difficult to reuse across different large language models, providers, and harnesses. We argue that stable parts of these workflows should be promoted into versioned scientific operations and exposed through common protocols. Existing general-purpose harnesses can then be specialized for HEP through task-specific sets of tools and skills, while community-maintained registries would make these capabilities discoverable and citable. We identify mismatches in conventions, assumptions, and domains of validity among independently developed operations as a potential obstacle to their composition, and discuss machine-readable scientific contracts as one possible solution. These design principles and evaluation guidelines provide a near-term path toward a portable and community-maintained agentic harness for HEP.

Menzo, Tony [Alabama U.; Fermilab] (ORCID:00000002↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗