Search NASA⌕ Search

SEARCH · Search NASA

Results for “image sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Compact orthogonal NMR field sensor

A Compact Orthogonal Field Sensor for emitting two orthogonal electro-magnetic fields in a common space. More particularly, a replacement inductor for existing NMR (Nuclear Magnetic Resonance) sensors to allow for NMR imaging. The Compact Orthogonal Field Sensor has a conductive coil and a central conductor electrically connected in series. The central conductor is at least partially surrounded by the coil. The coil and central conductor are electrically or electro-magnetically connected to a device having a means for producing or inducing a current through the coil and central conductor. The Compact Orthogonal Field Sensor can be used in NMR imaging applications to determine the position and the associated NMR spectrum of a sample within the electro-magnetic field of the central conductor.

47 OTHER INSTRUMENTATION↗

Determining Biosignatures by Complexity Analysis in Antarctic Cryptoendolithic Communities

One of the most difficult problems of life detection is that of identifying biosignatures across a wide range of scales using multiple co-registered probes. The technique should be of equal utility across a wide range of search spaces from remote sensors probing volumes of space or planetary surfaces, visual eye or camera searches across the surface of a rock in Antarctica, low resolution microscopic scanning of a rock or a space craft in situ, or high resolution electron microscope and computerized tomography scanning of geobiological samples. We describe here an approach to this problem which derives in large part from past work done in the area of astrophysics - namely the analysis of complexity in galactic signals by data compression methods. This approach is a radically new one for geobiology and astrobiology, and allows us to assess the complexity (and thus potential biogenicity) of an object being examined. This is done by considering the information within pixels of an image (regardless the sensor used to gather the information) as an energetic system capable of description in terms of classical thermodynamics. The image data space is searched by an algorithm that judges complexity via data compression (e.g., the more compressible it is, the less complex, and vice versa) and maximum entropy as originally outlined by Shannon. At present we are implementing methods to utilize images from multiple sensors gathering different kinds of information (e.g., visible gray-scale data, color analyses, UV fluorescence, chemical information, etc). We present here preliminary data from deep UV fluorescence and ESEM (Environmental Scanning Electron Microscope) images from a layered cryptoendolithic community of an Antarctic rock.

Storrie-Lombardi, M. C.↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

An evaluation of three-dimensional sensors for the extravehicular activity helper/retreiver

The Extravehicular Activity Retriever/Helper (EVAHR) is a robotic device currently under development at the NASA Johnson Space Center that is designed to fetch objects or to assist in retrieving an astronaut who may have become inadvertently de-tethered. The EVAHR will be required to exhibit a high degree of intelligent autonomous operation and will base much of its reasoning upon information obtained from one or more three-dimensional sensors that it will carry and control. At the highest level of visual cognition and reasoning, the EVAHR will be required to detect objects, recognize them, and estimate their spatial orientation and location. The recognition phase and estimation of spatial pose will depend on the ability of the vision system to reliably extract geometric features of the objects such as whether the surface topologies observed are planar or curved and the spatial relationships between the component surfaces. In order to achieve these tasks, accurate sensing of the operational environment and objects in the environment will therefore be critical. The qualitative and quantitative results of empirical studies of three sensors that are capable of providing three-dimensional information to the EVAHR, but using completely different hardware approaches are documented. The first of these devices is a phase shift laser with an effective operating range (ambiguity interval) of approximately 15 meters. The second sensor is a laser triangulation system designed to operate at much closer range and to provide higher resolution images. The third sensor is a dual camera stereo imaging system from which range images can also be obtained. The remainder of the report characterizes the strengths and weaknesses of each of these systems relative to quality of data extracted and how different object characteristics affect sensor operation.

Magee, Michael↗

Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging

Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525x525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25x25 {mu}m pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10{sup 5} electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 {mu}m, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at {approx}0.44 {mu}C/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a:Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Report of subpanel on feature extraction

The state of knowledge in feature extraction for Earth resource observation systems is reviewed and research tasks are proposed. Issues in the subpixel feature estimation problem are defined as: (1) the identification of image models which adequately describe the data and the sensor it is using; (2) the construction of local feature models based on those image models; and (3) the problem of trying to understand these effects of preprocessing on the entire process. The development of ground control point (GCP) libraries for automated selection presents two concerns. One is the organization of these GCP libraries for rectification problems, i.e., the problems of automatically selecting by computer the specific GCP's for particular registration tasks. Second is the importance of integrating ground control patterns in a data base management system, allowing interface to a large number of sensor image types with an automatic selection system. The development of data validation criteria for the comparison of different extraction techniques is also discussed.

Source record↗

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

Performance of optical sensors for cloud measurements deployed by the ARM Aerial Facility during ACE-ENA

During the Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA), a variety of in situ optical sensors using shadow imaging, scattering and holography were deployed by the Atmospheric Radiation Measurement (ARM) Aerial Facility to determine cloud properties. Taking advantage of the wide, overlapping range of instrumentation, we compare in situ cloud data from several different measurement methods for droplets up to 100 µm. Further, data processing was tailored to the encountered conditions, leading to good agreement. Improvements include noise reduction for holography and better out-of-focus correction for shadow imaging. Comparison between direct liquid water content measurements and optical sensors showed better agreement at higher droplet number concentrations (>120/cm 3 ).

47 OTHER INSTRUMENTATION↗

Understanding the Global Water and Energy Cycle Through Assimilation of Precipitation-Related Observations: Lessons from TRMM and Prospects for GPM

Understanding the Earth's climate and how it responds to climate perturbations relies on what we know about how atmospheric moisture, clouds, latent heating, and the large-scale circulation vary with changing climatic conditions. The physical process that links these key climate elements is precipitation. Improving the fidelity of precipitation-related fields in global analyses is essential for gaining a better understanding of the global water and energy cycle. In recent years, research and operational use of precipitation observations derived from microwave sensors such as the Tropical Rainfall Measuring Mission (TRMM) Microwave Imager and Special Sensor Microwave/Imager (SSM/I) have shown the tremendous potential of using these data to improve global modeling, data assimilation, and numerical weather prediction. We will give an overview of the benefits of assimilating TRMM and SSM/I rain rates and discuss developmental strategies for using space-based rainfall and rainfall-related observations to improve forecast models and climate datasets in preparation for the proposed multi-national Global Precipitation Mission (GPM).

Hou, Arthur↗

Ammonium Fluoride Passivation of CdZnTeSe Sensors for Applications in Nuclear Detection and Medical Imaging

Cadmium zinc telluride selenide (Cd1−xZnxTe1−ySey or CZTS) is one of the emerging CdTe-based semiconductor materials for detecting X- and gamma-ray radiation at or near room temperature (i.e., without cryogenic cooling). Potential applications of CZTS sensors include medical imaging, X-ray detection, and gamma-ray spectroscopy. Chemical passivation of CZTS is needed to reduce the conductivity of Te-rich surfaces, which reduces the noise and improves the device performance. In this study, we focus on the effect of surface passivation of CZTS using a 10% aqueous solution of ammonium fluoride. The effects of the chemical treatment were studied on the leakage current, charge transport measured as the electron mobility-lifetime (µτ) product, and the spectral resolution measured as the full-width at half-maximum (FWHM) of specific peaks. After passivation, the leakage current increased and began to decrease towards pre-passivation levels. The energy resolutions were recorded for eight applied voltages between −35 V and −200 V. The results showed an average of 25% improvement in the detector’s energy resolution for the 59.6 keV gamma peak of Am-241. The electron µτ product was unchanged at 2 × 10−3 cm2/V. These results show that ammonium fluoride is effective for chemical passivation of CZTS detectors.

36 MATERIALS SCIENCE↗

New Sensor Technology

The three instruments on the Orbiter Boom Sensor System (OBSS) will use a mix of U.S. and Canadian developed laser, television, infrared, and 3D imaging technologies. The sensors are the: 1) Laser Dynamic Range Imager (LDRI); 2) Intensified Television Camera (ITVC); 3) Laser Camera System (LCS).

Covault, Craig↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The GOES-R GeoStationary Lightning Mapper (GLM)

The Geostationary Operational Environmental Satellite (GOES-R) is the next series to follow the existing GOES system currently operating over the Western Hemisphere. Superior spacecraft and instrument technology will support expanded detection of environmental phenomena, resulting in more timely and accurate forecasts and warnings. Advancements over current GOES capabilities include a new capability for total lightning detection (cloud and cloud-to-ground flashes) from the Geostationary Lightning Mapper (GLM), and improved capability for the Advanced Baseline Imager (ABI). The Geostationary Lighting Mapper (GLM) will map total lightning activity (in-cloud and cloud-to-ground lighting flashes) continuously day and night with near-uniform spatial resolution of 8 km with a product refresh rate of less than 20 sec over the Americas and adjacent oceanic regions. This will aid in forecasting severe storms and tornado activity, and convective weather impacts on aviation safety and efficiency among a number of potential applications. In parallel with the instrument development (a prototype and 4 flight models), a GOES-R Risk Reduction Team and Algorithm Working Group Lightning Applications Team have begun to develop the Level 2 algorithms (environmental data records), cal/val performance monitoring tools, and new applications using GLM alone, in combination with the ABI, merged with ground-based sensors, and decision aids augmented by numerical weather prediction model forecasts. Proxy total lightning data from the NASA Lightning Imaging Sensor on the Tropical Rainfall Measuring Mission (TRMM) satellite and regional test beds are being used to develop the pre-launch algorithms and applications, and also improve our knowledge of thunderstorm initiation and evolution. An international field campaign planned for 2011-2012 will produce concurrent observations from a VHF lightning mapping array, Meteosat multi-band imagery, Tropical Rainfall Measuring Mission (TRMM) Lightning Imaging Sensor (LIS) overpasses, and related ground and in-situ lightning and meteorological measurements in the vicinity of Sao Paulo. These data will provide a new comprehensive proxy data set for algorithm and application development.

Goodman, Steven J.↗

Proceedings of the Augmented VIsual Display (AVID) Research Workshop

The papers, abstracts, and presentations were presented at a three day workshop focused on sensor modeling and simulation, and image enhancement, processing, and fusion. The technical sessions emphasized how sensor technology can be used to create visual imagery adequate for aircraft control and operations. Participants from industry, government, and academic laboratories contributed to panels on Sensor Systems, Sensor Modeling, Sensor Fusion, Image Processing (Computer and Human Vision), and Image Evaluation and Metrics.

Kaiser, Mary K.↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

Chemo-Mechanical Instabilities in Lithium Cobalt Oxide at Higher State-Of-Charge in Li-Ion Batteries

Transition metal oxide cathodes are widely used in commercial Li-ion batteries. However, their practical charge capacity is limited due to severe chemo-mechanical instabilities at higher charge voltage, and state-of-charge condition. Here, in situ stress and strain measurements were synchronized to probe mechanical deformations in the lithium cobalt oxide (LCO) cathode via a multi-beam stress sensor and digital image correlation, respectively. In situ mechanical measurements revealed how Li removal from the electrode structure induces deformations on the LCO composite cathodes during cycling. The structure and morphology of the LCO cathodes were further investigated by X-ray diffraction (XRD) and scanning electron microscopy (SEM) studies. Two distinct electrochemical and mechanical behaviors were identified when the LCO was charged up to 4.65 V. The LCO undergoes a compressive stress generation when charged up to 4.2 V and surface fractures on the LCO particles were detected by SEM. LCO cathode experienced significantly large contractions (negative strains) when charged up to 4.65 V, where intergranular crack formation and phase transformation were detected on the LCO particles via SEM and XRD, respectively. Overall, the study bridges complicated structural deformations with in situ analysis of mechanical degradations in LCO cathodes charged at higher voltages. The correlation is vital to understanding instability mechanisms in transition metal oxides at high voltages for alkali metal ion batteries.

higher state-of-charge↗