SU-E-T-575: Isocenter Shifts in Treatment Planning and Its Clinical Implications

Purpose: To investigate causes of isocenter shifts in treatment planning and its clinical impact on patient treatment efficiency and safety. Methods/Materials: Treatment planning data of 340 patients under treatment over 8 weeks period were gathered to identify isocenter shifts according to site of the treatment, types of treatment plan or types of the machine used. Treatment plans included inversed and forward IMRT, as well as 3D plans. Treatment sites included pelvis, chest, abdomen, breasts, head and necks and extremities. Re-planning were performed without the isocenter shift for pelvis and chest plans, the dosimetric parameters such as PTV coverage, and dose sparing of OARs of these plans were analyzed and compared. Results/Discussions: Results showed that the isocenter shift was always necessary for some of sites such as breasts, two or more distinctive PTVs, or special cases such as large PTV treated with enhanced dynamic wedge. Many other cases, the re-planning results indicated 53% of the plans that the same quality of the plan can be achieved without the shift of the isocenter. Repositioning patients on a daily basis demanded unambiguous instructions for therapists for patient setups, and additional time to perform the shifts before treatment. Opportunities for error propagation exist during the communication and hand-over of such plans. Conclusion: Isocenter shifts demanded unambiguous instructions and times for therapists for daily patient setups, therefore it impacted both safety and efficiency of the patient treatment. Based on the analysis, the isocenter shifts were unavoidable for cases such as treatment of multiple sites, overcoming limitations of treatment machines, and/or sometime better dosimetry. However, we found many initially proposed shifts may have been eliminated either by careful planning or by improved CT simulation process such as detailed review of the images and localization of the PTV during simulation.

60 APPLIED LIFE SCIENCES↗

Novel Applications of the Multi-Beam SEM [Abstract Only]

The Zeiss Multi-Beam Scanning Electron Microscope (MultiSEM) was used to image a wide array samples using non-standard operating conditions. The ability of this new, high-throughput imaging technique to produce high-quality images was assessed during this one year LDRD. In addition to exploring new imaging conditions, sample preparation techniques, coupled with theoretical simulations, were explored to optimize the MultiSEM images. To obtain details about the devices imaged, as well as the experimental details, please refer to the classified report from the project manager, Bradley Gabel, or the Cyber IA lead, Justin Ford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution versus speckle relative to geologic interpretability of spaceborne radar images - A survey of user preference

A survey conducted to evaluate user preference for resolution versus speckle relative to the geologic interpretability of spaceborne radar images is discussed. Thirteen different resolution/looks combinations are simulated from Seasat synthetic-aperture radar data of each of three test sites. The SAR images were distributed with questionnaires for analysis to 85 earth scientists. The relative discriminability of geologic targets at each test site for each simulation of resolution and speckle on the images is determined on the basis of a survey of the evaluations. A large majority of the analysts respond that for most targets a two-look image at the highest simulated resolution is best. For a constant data rate, a higher resolution is more important for target discrimination than a higher number of looks. It is noted that sand dunes require more looks than other geologic targets. At all resolutions, multiple-look images are preferred over the corresponding single-look image. In general, the number of multiple looks that is optimal for discriminating geologic targets is inversely related to the simulated resolution.

Ford, J. P.↗

Predicting the stability of surface phases of molybdenum selenides

The selenization of molybdenum might become an important step in the production of nanostructures based on the layered compound MoSe{sub 2}. It is already technologically relevant for the production of thin film chalcopyrite solar cells. However, the control of the process is still very poor, due to the lack of basic knowledge of the surface thermodynamics of the system. Here, we present a theoretical study on the stability of surface adlayers of Se on the Mo(110) surface, predicting surface patterns and their stability range in terms of temperature and selenium partial pressure. Our results, based on density functional theory, show that the attainable Se coverages range from 1/4 to 3/4 of a monolayer for systems in equilibrium with a gas formed of Se molecules. We provide simulated scanning tunneling microscopy images to help the experimental characterization of adsorbed surface patterns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Machine learning–aided real-time detection of keyhole pore generation in laser powder bed fusion

Porosity defects are currently a major factor that hinders the widespread adoption of laser-based metal additive manufacturing technologies. One common porosity occurs when an unstable vapor depression zone (keyhole) forms because of excess laser energy input. With simultaneous high-speed synchrotron x-ray imaging and thermal imaging, coupled with multiphysics simulations, we discovered two types of keyhole oscillation in laser powder bed fusion of Ti-6Al-4V. Amplifying this understanding with machine learning, we developed an approach for detecting the stochastic keyhole porosity generation events with submillisecond temporal resolution and near-perfect prediction rate. Finally, the highly accurate data labeling enabled by operando x-ray imaging allowed us to demonstrate a facile and practical way to adopt our approach in commercial systems.

42 ENGINEERING↗

Practical Three-Dimensional Curvilinear Aperture Monopulse Synthetic Aperture Radar

When collected over a curved path, Synthetic Aperture Radar (SAR) contains information about the three-dimensional content of a scene that can aid interpretation of this difficult imaging modality. In a point scatterer simulation with amplitudes and heights derived from a real SAR image pair, we supplement confocal processing with a monopulse-based algorithm to compute heights of certain bright points, which we find automatically. In SAR, bright points often reflect man-made infrastructure central to scene interpretation.

Story, Mark [ORNL] (ORCID:0000000289148911)↗

Gamma-Ray Point-Source Localization and Sparse Image Reconstruction using Poisson Likelihood

Gamma-ray imaging trys to reconstruct the spatial and intensity distribution of gamma-emitting radionuclides from a set of measurements. Wholly, this problem is solved by discretizing the spatial dimensions and employing the maximum likelihood expectation maximization (ML-EM) algorithm, with or without some form of regularization. While the generality of this formulation enables use in a wide variety of scenarios, it is susceptible to overfitting, limited by the discretization of spatial coordinates, and can be computationally expensive. We present a novel approach to 3D gamma-ray image reconstruction for scenarios where sparsity may be assumed, for example radiological source search. In this work we first formulate a point-source localization (PSL) approach as an optimization problem where both position and source intensity are continuous variables. We then extend and generalize this formulation to an iterative algorithm called additive point-source localization (APSL) for sparse parametric image reconstruction. A set of simulated source search scenarios using a single non-directional detector are considered, finding improved image accuracy and computational efficiency with APSL over traditional grid-based methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographical imaging using uniformly redundant arrays

An investigation is conducted of the behavior of two types of uniformly redundant array (URA) when used for close-up imaging. One URA pattern is a quadratic residue array whose characteristics for imaging planar sources have been simulated by Fenimore and Cannon (1978), while the second is based on m sequences that have been simulated by Gunson and Polychronopulos (1976) and by MacWilliams and Sloan (1976). Close-up imaging is necessary in order to obtain depth information for tomographical purposes. The properties of the two URA patterns are compared with a random array of equal open area. The goal considered in the investigation is to determine if a URA pattern exists which has the desirable defocus properties of the random array while maintaining artifact-free image properties for in-focus objects.

Cannon, T. M.↗

Optical Modeling Activities for NASA's James Webb Space Telescope (JWST): V. Operational Alignment Updates

This paper is part five of a series on the ongoing optical modeling activities for the James Webb Space Telescope (JWST). The first two papers discussed modeling JWST on-orbit performance using wavefront sensitivities to predict line of sight motion induced blur, and stability during thermal transients. The third paper investigates the aberrations resulting from alignment and figure compensation of the controllable degrees of freedom (primary and secondary mirrors), which may be encountered during ground alignment and on-orbit commissioning of the observatory, and the fourth introduced the software toolkits used to perform much of the optical analysis for JWST. The work here models observatory operations by simulating line-of-sight image motion and alignment drifts over a two-week period. Alignment updates are then simulated using wavefront sensing and control processes to calculate and perform the corrections. A single model environment in Matlab is used for evaluating the predicted performance of the observatory during these operations.

Howard, Joseph M.↗

WE-G-204-01: BEST IN PHYSICS (IMAGING): Effect of Image Processing Parameters On Nodule Detectability in Chest Radiography

Purpose: To investigate the effect of varying system image processing parameters on lung nodule detectability in digital radiography. Methods: An anthropomorphic chest phantom was imaged in the posterior-anterior position using a GE Discovery XR656 digital radiography system. To simulate lung nodules, a polystyrene board with 6.35mm diameter PMMA spheres was placed adjacent to the phantom (into the x-ray path). Due to magnification, the projected simulated nodules had a diameter in the radiographs of approximately 7.5 mm. The images were processed using one of GE’s default chest settings (Factory3) and reprocessed by varying the “Edge” and “Tissue Contrast” processing parameters, which were the two user-configurable parameters for a single edge and contrast enhancement algorithm. For each parameter setting, the nodule signals were calculated by subtracting the chest-only image from the image with simulated nodules. Twenty nodule signals were averaged, Gaussian filtered, and radially averaged in order to generate an approximately noiseless signal. For each processing parameter setting, this noise-free signal and 180 background samples from across the lung were used to estimate ideal observer performance in a signal-known-exactly detection task. Performance was estimated using a channelized Hotelling observer with 10 Laguerre-Gauss channel functions. Results: The “Edge” and “Tissue Contrast” parameters each had an effect on the detectability as calculated by the model observer. The CHO-estimated signal detectability ranged from 2.36 to 2.93 and was highest for “Edge” = 4 and “Tissue Contrast” = −0.15. In general, detectability tended to decrease as “Edge” was increased and as “Tissue Contrast” was increased. A human observer study should be performed to validate the relation to human detection performance. Conclusion: Image processing parameters can affect lung nodule detection performance in radiography. While validation with a human observer study is needed, model observer detectability for common tasks could provide a means for optimizing image processing parameters.

60 APPLIED LIFE SCIENCES↗

Study of the Imaging Capabilities of SPIRIT/SPECS Concept Interferometers

Several new space science mission concepts under development at NASA-GSFC for astronomy are intended to carry out synthetic imaging using Michelson interferometers or direct (Fizeau) imaging with sparse apertures. Examples of these mission concepts include the Stellar Imager (SI), the Space Infrared Interferometric Telescope (SPIRIT), the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS), and the Fourier-Kelvin Stellar Interferometer (FKSI). We have been developing computer-based simulators for these missions. These simulators are aimed at providing a quantitative evaluation of the imaging capabilities of the mission by modeling the performance on different realistic targets in terms of sensitivity, angular resolution, and dynamic range. Both Fizeau and Michelson modes of operation can be considered. Our work is based on adapting a computer simulator called imSIM which was initially written for the Space Interferometer Mission in order to simulate the imaging mode of new missions such as those listed. This report covers the activities we have undertaken to provide a preliminary version of a simulator for the SPIRIT mission concept.

Allen, Ronald J.↗

Towards a quantitative description of tunneling conductance of superconductors: Application to LiFeAs

Since the discovery of iron-based superconductors, a number of theories have been put forward to explain the qualitative origin of pairing, but there have been few attempts to make quantitative, material-specific comparisons to experimental results. The spin-fluctuation theory of electronic pairing, based on first-principles electronic structure calculations, makes predictions for the superconducting gap. Within the same framework, the surface wave functions may also be calculated, allowing, e.g., for detailed comparisons between theoretical results and measured scanning tunneling topographs and spectra. We present such a comparison between theory and experiment on the Fe-based superconductor LiFeAs. Our results for the homogeneous surface as well as impurity states are presented as a benchmark test of the theory. For the homogeneous system, we argue that the maxima of topographic image intensity may be located at positions above either the As or Li atoms, depending on tip height and the setpoint current of the measurement. We further report the experimental observation of transitions between As- and Li-registered lattices as functions of both tip height and setpoint bias, in agreement with this prediction. Next, we give a detailed comparison between the simulated scanning tunneling microscopy images of transition-metal defects with experiment. Finally, we discuss possible extensions of the current framework to obtain a theory with true predictive power for scanning tunneling microscopy in Fe-based systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-I-20: Comprehensive Quality Assurance Test of Second Generation Toshiba Aquilion Large Bore CT Simulator Based On AAPM TG-66 Recommendations

Purpose: AAPM radiation therapy committee task group No. 66 (TG-66) published a report which described a general approach to CT simulator QA. The report outlines the testing procedures and specifications for the evaluation of patient dose, radiation safety, electromechanical components, and image quality for a CT simulator. The purpose of this study is to thoroughly evaluate the performance of a second generation Toshiba Aquilion Large Bore CT simulator with 90 cm bore size (Toshiba, Nasu, JP) based on the TG-66 criteria. The testing procedures and results from this study provide baselines for a routine QA program. Methods: Different measurements and analysis were performed including CTDIvol measurements, alignment and orientation of gantry lasers, orientation of the tabletop with respect to the imaging plane, table movement and indexing accuracy, Scanogram location accuracy, high contrast spatial resolution, low contrast resolution, field uniformity, CT number accuracy, mA linearity and mA reproducibility using a number of different phantoms and measuring devices, such as CTDI phantom, ACR image quality phantom, TG-66 laser QA phantom, pencil ion chamber (Fluke Victoreen) and electrometer (RTI Solidose 400). Results: The CTDI measurements were within 20% of the console displayed values. The alignment and orientation for both gantry laser and tabletop, as well as the table movement and indexing and scanogram location accuracy were within 2mm as specified in TG66. The spatial resolution, low contrast resolution, field uniformity and CT number accuracy were all within ACR’s recommended limits. The mA linearity and reproducibility were both well below the TG66 threshold. Conclusion: The 90 cm bore size second generation Toshiba Aquilion Large Bore CT simulator that comes with 70 cm true FOV can consistently meet various clinical needs. The results demonstrated that this simulator complies with the TG-66 protocol in all aspects including electromechanical component, radiation safety component, and image quality component. Employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-01: Performance Characterization of Regularized-Reconstruction Algorithm for 90Y PET/CT Images

Purpose: {sup 90}Y PET/CT imaging and quantification have recently been suggested as an approach of treatment verification. However, due to low positron yield (32ppm), the {sup 90}Y-PET/CT images are very noisy. Iterative reconstruction techniques that employ regularization, e.g. block sequential regularized expectation maximization (BSREM) algorithm (recently implemented on GE scanners – QClear™), has the potential to increase quantitative accuracy with lower noise penalty compared to OSEM. Our aim is to investigate the performance of RR algorithms in {sup 90}Y PET/CT studies. Methods: A NEMA IEC phantom filled with 3GBq {sup 90}YCl{sub 2} (to simulate patient treatment) was imaged on GE-D690 for 1800s/bed. The sphere-to-background ratio of 7. The data were reconstructed using OSEM and BSREM with PSF modeling and TOF correction while varying the iterations (IT) from 1–6 with fixed 24subsets. For BSREM, the edge-preservation parameter (γ ) was 2 and the penalty-parameters (β) was varied 350–950. In all cases a post-reconstruction filter of 5.2mm (2pixel) transaxial and standard z-axis were used. Sphere average activity concentration (AC) and background standard deviation (SD) were then calculated from VOIs drawn in the spheres and background. Results: Increasing IT from 1to6, the %SD in OSEM increased from 30% to 80%, whereas %SD in BSREM images increased by <5% for all βs. BSREM with β=350 didn’t offer any improvement over OSEM (convergence of mean achieved at 2 IT, in this study). Increasing β from 350 to 950 reduced the AC accuracy of small spheres (<20mm) by 10% and noise from 40% to 20%, which resulted in CNR increase from 11 to 17. Conclusion: In count-limited studies such as {sup 90}Y PET/CT, BSREM can be used to suppress image noise and increase CNR at the expense of a relatively small decrease of quantitative accuracy. The BSREM parameters need to be optimized for each study depending on the radionuclides and count densities. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA13898 and was also partly supported by General Electric.

60 APPLIED LIFE SCIENCES↗

SU-E-J-226: Propagation of Pancreas Target Contours On Respiratory Correlated CT Images Using Deformable Image Registration

Purpose: Respiratory Correlated CT (RCCT) scans to assess intra-fraction motion among pancreatic cancer patients undergoing radiotherapy allow for dose sparing of normal tissues, in particular for the duodenum. Contour propagation of the gross tumor volume (GTV) from one reference respiratory phase to 9 other phases is time consuming. Deformable image registration (DIR) has been successfully used for high contrast disease sites but lower contrast for pancreatic tumors may compromise accuracy. This study evaluates the accuracy of Fast Free Form (FFF) registration-based contour propagation of the GTV on RCCT scans of pancreas cancer patients. Methods: Twenty-four pancreatic cancer patients were retrospectively studied; 20 had tumors in the pancreatic head/neck, 4 in the body/tail. Patients were simulated with RCCT and images were sorted into 10 respiratory phases. A radiation oncologist manually delineated the GTV for 5 phases (0%, 30%, 50%, 70% and 90%). The FFF algorithm was used to map deformations between the EE (50%) phase and each of the other 4 phases. The resultant deformation fields served to propagate GTV contours from EE to the other phases. The Dice Similarity Coefficient (DSC), which measures agreement between the DIR-propagated and manually-delineated GTVs, was used to quantitatively examine DIR accuracy. Results: Average DSC over all scans and patients is 0.82 and standard deviation is 0.09 (DSC range 0.97–0.57). For GTV volumes above and below the median volume of 20.2 cc, a Wilcoxon rank-sum test shows significantly different DSC (p=0.0000002). For the GTVs above the median volume, average +/− SD is 0.85 +/− 0.07; and for the GTVs below, the average +/− SD is 0.75 +/−0.08. Conclusion: For pancreatic tumors, the FFF DIR algorithm accurately propagated the GTV between the images in different phases of RCCT, with improved performance for larger tumors.

60 APPLIED LIFE SCIENCES↗

Remote Sensing of Radiative and Microphysical Properties of Clouds During TC (sup 4): Results from MAS, MASTER, MODIS, and MISR

The Moderate Resolution Imaging Spectroradiometer (MODIS) Airborne Simulator (MAS) and MODIS/Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) Airborne Simulator (MASTER) were used to obtain measurements of the bidirectional reflectance and brightness temperature of clouds at 50 discrete wavelengths between 0.47 and 14.2 microns (12.9 microns for MASTER). These observations were obtained from the NASA ER-2 aircraft as part of the Tropical Composition, Cloud and Climate Coupling (TC4) experiment conducted over Central America and surrounding Pacific and Atlantic Oceans between 17 July and 8 August 2007. Multispectral images in eleven distinct bands were used to derive a confidence in clear sky (or alternatively the probability Of cloud) over land and ocean ecosystems. Based on the results of individual tests run as part of the cloud mask, an algorithm was developed to estimate the phase of the clouds (liquid water, ice, or undetermined phase). The cloud optical thickness and effective radius were derived for both liquid water and ice clouds that were detected during each flight, using a nearly identical algorithm to that implemented operationally to process MODIS Cloud data from the Aqua and Terra satellites (Collection 5). This analysis shows that the cloud mask developed for operational use on MODIS, and tested using MAS and MASTER data in TC(sup 4), is quite capable of distinguishing both liquid water and ice clouds during daytime conditions over both land and ocean. The cloud optical thickness and effective radius retrievals use five distinct bands of the MAS (or MASTER), and these results were compared with nearly simultaneous retrievals of marine liquid water clouds from MODIS on the Terra spacecraft. Finally, this MODIS-based algorithm was adapted to Multiangle Imaging SpectroRadiometer (MISR) data to infer the cloud optical thickness Of liquid water clouds from MISR. Results of this analysis are compared and contrasted.

King, Michael D.↗

Hybrid Large Eddy Simulation/Reynolds-Averaged Navier–Stokes Analysis of a Premixed Ethylene-Fueled Dual-Mode Scramjet Combustor

Hydrocarbon fuels offer optimal high energy per volume for scramjet applications for sustained hypersonic flight but require additional residence time due to slower ignition delays (compared with hydrogen fuel). The injection of ethylene at the start of the isolator of a dual-mode scramjet combustor, operating in ramjet mode, allows sufficient mixing to achieve efficient premixed turbulent combustion. A cavity flameholder anchors the flame, supplying sufficient radicals to sustain a stable flame in the high-speed environment. This work investigates flame structure and stabilization limits of a new configuration with a scaled-down cavity embedded in the flow path of the combustor with a strut and insert. The cavity is reduced in size by one-third to enable eventual direct numerical simulations of the flame stabilization process. This work, however, focuses on modeling the full isolator/combustor geometry using a hybrid large eddy simulation/Reynolds-averaged Navier–Stokes simulation strategy. Additionally, particle image velocimetry, planar laser-induced fluorescence, coherent anti-Stokes Raman spectroscopy, and pressure measurements are compared with numerical predictions to analyze and characterize the conditions within the combustor, including flame structure, flow velocities, species composition, and wall pressure. An adjustable air throttle in the extender is able to control the placement of the shock train in the isolator and maintain a stable flame at various equivalence ratios. The simulations show reasonably good agreement with the experimental scalar and velocity data and predict a flame angle consistent with premixed turbulent flame-speed correlations.

42 ENGINEERING↗

The simulated space proton environment for radiation effects on Space Telescope Imaging Spectrograph (STIS)

The space telescope imaging spectrograph (STIS) is a second generation instrument planned for the Hubble Space Telescope (HST) which is currently in orbit. Candidate glasses and other transmitting materials are being considered for order sorters, in-flight calibration filters, detector windows, and calibration lamps. The glasses for in-flight calibration filters showed significant drop in UV transmission, but can probably still be used on STIS. The addressed topics include the Hubble radiation environment, simulation of orbital exposure at Harvard Cyclotron Laboratory, measurement of spectral transmission, and comments on individual samples.

Becher, Jacob↗