Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverted data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

HOLLOTRON switch for megawatt lightweight space inverters

The feasibility of satisfying the switching requirements for a megawatt ultralight inverter system using HOLLOTRON switch technology was determined. The existing experimental switch hardware was modified to investigate a coaxial HOLLOTRON switch configuration and the results were compared with those obtained for a modified linear HOLLOTRON configuration. It was concluded that scaling the HOLLOTRON switch to the current and voltage specifications required for a megawatt converter system is indeed feasible using a modified linear configuration. The experimental HOLLOTRON switch operated at parameters comparable to the scaled coaxial HOLLOTRON. However, the linear HOLLOTRON data verified the capability for meeting all the design objectives simultaneously including current density (greater than 2 A/sq cm), voltage (5 kV), switching frequency (20 kHz), switching time (300 ns), and forward voltage drop (less than or equal to 20 V). Scaling relations were determined and a preliminary design was completed for an engineering model linear HOLLOTRON switch to meet the megawatt converter system specifications.

Poeschel, R. L.↗

The Mean Seasonal Cycle in Relative Sea Level From Satellite Altimetry and Gravimetry

Satellite altimetry and gravimetry are used to determine the mean seasonal cycle in relative sea level, a quantity relevant to coastal flooding and related applications. The main harmonics (annual, semiannual, terannual) are estimated from 25 years of gridded altimetry, while several conventional altimeter “corrections” (gravitational tide, pole tide, and inverted barometer) are restored. To transform from absolute to relative sea levels, a model of vertical land motion is developed from a high-resolution seasonal mass inversion estimated from satellite gravimetry. An adjustment for annual geocenter motion accounts for use of a center-of-mass reference frame in satellite orbit determination. A set of 544 test tide gauges, from which seasonal harmonics have been estimated from hourly measurements, is used to assess how accurately each adjustment to the altimeter data helps converge the results to true relative sea levels. At these gauges, the median annual and semiannual amplitudes are 7.1 cm and 2.2 cm, respectively. The root-mean-square differences with altimetry are 3.24 and 1.17 cm, respectively, which are reduced to 1.93 and 0.86 cm after restoration of corrections and adjustment for land motion. Example outliers highlight some limitations of present-day coastal altimetry owing to inadequate spatial resolution: upwelling and currents off Oregon and wave setup at Minamitori Island.

Richard D Ray↗

PV Reliability Lessons from 100,000 Systems

Despite the importance of reliability to the cost competitiveness of PV, large data sets enabling high-level investigation of the technology’s performance in the field are relatively scarce. Dirk C. Jordan, Chris Deline, Bill Marion and Teresa Barnes of the National Renewable Energy Laboratory, and Mark Bolinger of the Lawrence Berkeley National Laboratory study a unique data set of 100,000 PV systems in the US, drawing out tips for better reliability that have relevance to other parts of the world.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Existing Whole-House Solutions Case Study: Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California

In this project, the Building America research team, IBACOS, worked with K. Hovnanian Homes to monitor the effectiveness of the space conditioning system in a 2,253-ft single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home.

air distribution system↗

Software-Based Challenges of Developing the Future Distribution Grid

The software that the utility industry currently uses may be insufficient to analyze the distribution grid as it rapidly modernizes to include active resources such as distributed generation, switch and voltage control, automation, and increasingly complex loads. Although planners and operators have traditionally viewed the distribution grid as a passive load, utilities and consultants increasingly need enhanced analysis that incorporates active distribution grid loads in order to ensure grid reliability. Numerous commercial and open-source tools are available for analyzing distribution grid systems. These tools vary in complexity from providing basic load-flow and capacity analysis under steady-state conditions to time-series analysis and even geographical representations of dynamic and transient events. The need for each type of analysis is not well understood in the industry, nor are the reasons that distribution analysis requires different techniques and tools both from those now available and from those used for transmission analysis. In addition, there is limited understanding of basic capability of the tools and how they should be practically applied to the evolving distribution system. The study reviews the features and state of the art capability of current tools, including usability and visualization, basic analysis functionality, advanced analysis including inverters, and renewable generation and load modeling. We also discuss the need for each type of distribution grid system analysis. In addition to reviewing basic functionality current models, we discuss dynamics and transient simulation in detail and draw conclusions about existing software?s ability to address the needs of the future distribution grid as well as the barriers to modernization of the distribution grid that are posed by the current state of software and model development. Among our conclusions are that accuracy, data transfer, and data processing abilities are key to future distribution grid modeling, and measured data sources are a key missing element . Modeling tools need to be calibrated based on measured grid data to validate their output in varied conditions such as high renewables penetration and rapidly changing topology. In addition, establishing a standardized data modeling format would enable users to transfer data among tools to take advantage of different analysis features. ?

99 GENERAL AND MISCELLANEOUS↗

Two Variable Radio Sources Near the Position of GRB 940301

We report on the results of a search for a radio counterpart to the strong gamma-ray burst GRB 940301. Observations with the Westerbork Synthesis Radio Telescope of the Compton Telescope error box region of GRB 940301 began on March 4, 1994, at 21 cm and April 2, 1994, at 92 cm. No flux density variations were detected at 92 cm above S= 10 mJy (5 (sigma)) within a period of 1 to 4 months after the burst. However, when we compared the field with Westerbork Northern Sky Survey data, taken two years prior to GRB 940301, we found two radio sources with significantly increased flux densities. These sources, only 17 min. apart, are located at the 2.3 and 2.6(sigma) Compton Telescope confidence contours. Their separation from the Inter Planetary Network annulus virtually excludes association with GRB 940301. Further observations in January 1996 reveal that the sources continued to change in flux density. The relatively large flux density variations at 92 cm, compared to those at higher frequencies, and the inverted spectra in the frequency range from 325-38O MHz make the sources somewhat unusual. Because the sources were already detected at 5 GHz in 1986 most, if not all, of the radio emission is probably associated with activity in Active Galactic Nuclei in distant galaxies.

Galama, T. J.↗

Distributed Energy Communications & Controls, Lab Activities - Summary

The purpose is to develop controls for inverter-based renewable and non-renewable distributed energy systems to provide local voltage, power and power quality support for loads and the power grid. The objectives are to (1) develop adaptive controls for inverter-based distributed energy (DE) systems when there are multiple inverters on the same feeder and (2) determine the impact of high penetration high seasonal energy efficiency ratio (SEER) air conditioning (A/C) units on power systems during sub-transmission faults which can result in an A/C compressor motor stall and assess how inverter-based DE can help to mitigate the stall event. The Distributed Energy Communications & Controls Laboratory (DECC) is a unique facility for studying dynamic voltage, active power (P), non-active power (Q) and power factor control from inverter-based renewable distributed energy (DE) resources. Conventionally, inverter-based DE systems have been designed to provide constant, close to unity power factor and thus not provide any voltage support. The DECC Lab interfaces with the ORNL campus distribution system to provide actual power system testing of the controls approach. Using mathematical software tools and the DECC Lab environment, we are developing and testing local, autonomous and adaptive controls for local voltage control and P & Q control for inverter-based DE. We successfully tested our active and non-active power (P,Q) controls at the DECC laboratory along with voltage regulation controls. The new PQ control along with current limiter controls has been tested on our existing inverter test system. We have tested both non-adaptive and adaptive control modes for the PQ control. We have completed several technical papers on the approaches and results. Electric power distribution systems are experiencing outages due to a phenomenon known as fault induced delayed voltage recovery (FIDVR) due to air conditioning (A/C) compressor motor stall. Local voltage collapse from FIDVR is occurring in part because modern air-conditioner and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip than older motors. These motors can stall in less than three cycles (0.05 s) when a fault, for example, on the sub-transmission system, causes voltage on the distribution system to sag to 70% or less of nominal. We completed a new test system for A/C compressor motor stall testing at the DECC Lab. The A/C Stall test system is being used to characterize when and how compressor motors stall under low voltage and high compressor pressure conditions. However, instead of using air conditioners, we are using high efficiency heat pumps. We have gathered A/C stall characterization data for both sustained and momentary voltage sags of the test heat pump. At low enough voltage, the heat pump stalls (compressor motor stops and draws 5-6 times normal current in trying to restart) due to low inertia and low torque of the motor. For the momentary sag, we are using a fast acting contactor/switch to quickly switch from nominal to the sagged voltage in cycles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Smoothers for Extreme-Scale Computing

Patch-based relaxation refers to a family of methods for solving linear systems which partitions the matrix into smaller pieces often corresponding to groups of adjacent degrees of freedom residing within patches of the computational domain. The two most common families of patch-based methods are block-Jacobi and Schwarz methods, where the former typically corresponds to non-overlapping domains and the later implies some overlap. We focus on cases where each patch consists of the degrees of freedom on a finite element method mesh cell. Patch methods often capture complex local physics much more effectively than simpler point-smoothers such as Jacobi; however, forming, inverting, and applying each patch can be prohibitively expensive in terms of both storage and computation time. To this end, we propose several approaches for performing analysis on these patches and constructing a reduced representation. The compression techniques rely on either matrix norm comparisons or unsupervised learning via a clustering approach. We illustrate how it is frequently possible to retain/factor less than 5% of all patches and still develop a method that converges only a little slower than when all patches are stored/factored.

97 MATHEMATICS AND COMPUTING↗

Direct Measurement of Diffusion Coefficients: Evidence for Diffusive Stochastic Heating in Collisionless Plasmas

Open questions in collisionless plasma dissipation can be addressed using space-based observations in different astrophysical environments, with implications for both astrophysical and laboratory plasma systems. We study a low-𝛽, highly imbalanced, sub-Alfvénic stream observed by Parker Solar Probe (PSP) to identify and distinguish between signatures of stochastic heating (SH) and resonant heating (RH) by parallel ion cyclotron waves (∥-ICWs). Prior work studying this stream [Trevor A. Bowen et al., Stochastic heating in the sub-Alfvénic solar wind, Phys. Rev. Lett. 135, 255201 (2025)] showed that the SH rate, accounting for intermittency, matched the amplitude of the local energy transfer (LET) rate, while the RH rate did not. This comparison relied on a number of assumptions regarding the nature of the diffusive process and the calculation of the LET rate. We introduce a novel technique of inverting the proton guiding center equation to empirically measure velocity-space diffusion coefficients using three-dimensional proton velocity distribution functions, from the ion electrostatic analyzer (the Solar Probe Analyzer for Ions) on PSP. Measured diffusion coefficients are used to determine phase-space heating rates, leading to a calculation of a fully kinetic heating rate independent of assumptions made in prior work. We show that scale-dependent analytic expressions for SH via noncoherent fluctuations match the empirical measurements from PSP data, provided that we account for intermittency in the heating calculation. In contrast, the derived heating rates for SH that accounts for the effects of the helicity barrier and heating rates for RH via ∥-ICWs do not peak in the same region of velocity space as the empirical measurements, nor do they reach the required magnitude. Our approach provides novel methodology to uniquely identify and constrain heating processes in collisionless plasmas and shows evidence of a Fokker-Planck-like diffusive process in the near-Sun solar wind.

Plasma kinetic theory↗

An equipotential model for auroral arcs

Shaped charge barium release data and high-speed auroral image data show the likely existence of anomalously large (about 1 V/m referred to the 100-km level) electric fields at distances the order of one earth radius above the earth. A model of the electrostatic field above an auroral arc is proposed in which the magnetic field lines are not all equipotentials. Use is made of recent theoretical work on oblique current-driven electrostatic shocks to demonstrate the plausibility of nonequipotential field lines. The model is addressed to the structure of inverted-V electron spectra, current continuity between magnetosphere and ionosphere, and the results of recent shaped charge barium experiments. The model is used to identify specific gaps in our understanding of auroral phenomena.

Swift, D. W.↗

Dynamic Characterization of the Crew Module Uprighting System for NASA’s Orion Crew Module

The Orion Crew Module Uprighting System is a set of five airbag that are responsible for the uprighting of the crew module in the case of an inverted splashdown. A series of tests during the Underway Recovery Test 7 (URT-7) were run in preparation for the Artemis I mission, where the dynamic characterization of the CMUS in an ocean wave environment was performed. A Datawell Waverider DWR-G4 wave buoy was deployed to the characterize the wave environment during these tests. The heave measurements from this buoy were projected to the Orion Crew Module Buoyancy Test Article location by two different methods: (1) directly time-shifting the data, and (2) performing a frequency-domain, phase-shifting operation. Results demonstrate that the phase-shifting operation led to better correlation with the true crew module response to wave excitation as compared with the purely time-shifted method. Additionally, a novel approach to localize an object in a bidirectional wave field based on its heave response is presented and validated with URT- 7 data. Given a wave measurement device at a known location, one can estimate the relative distance to another object based solely off its heave response. Results show that if signals have sufficiently good correlation, this method can be used to estimate the relative separation between two objects in the same wave field.

Vertaska, Ivan Bertaska↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Seismotectonic evidence for subduction beneath the Eastern Greater Caucasus

SUMMARY We generated high-resolution 3-D seismic velocity models as well as a relocated earthquake catalogue across the eastern Greater Caucasus and Kura basins. This work was done using data from the recently upgraded Republic Seismological Survey Center's (RSSC) seismic network. We generated our tomographic images of crustal velocity structure in Azerbaijan using double-difference inversions (i.e. tomoDD and hypoDD). Earthquake catalogues from the RSSC between 2011 and 2016 were used; these catalogues include absolute arrival times of 103 288 P- and 120 952 S-wave traveltime picks for 7574 events recorded at 35 stations in Azerbaijan. Beginning with a layered, 1-D velocity model that was estimated using VELEST, we inverted simultaneously for relative location, Vp and Vs on a 3-D grid with dimensions 670 × 445 × 45 km, with a uniform grid spacing of 55 × 55 × 5 km for all of Azerbaijan. We observe that the relocated hypocentres cluster into two depth ranges, at the surface and at depth, that appear to correspond to major fault zones and the top of a subducting plate. Additionally, we note intermediate depth seismicity (∼50–60 km) beneath the Kura Basin, and a northward deepening of earthquake depths. Seismic velocities vary significantly throughout the study region; we observe very slow velocities throughout the Kura Basin between 5 and 15 km, and elevated velocities at 20–35 km. The wholesale velocity structure and seismic structure of Kura Basin strongly mirrors that of the Caspian Sea, which suggests that the geodynamics of the Caspian continue westwards into Azerbaijan. The key results of this study suggest that the northward subduction observed in the Caspian Sea continues beneath the Eastern Greater Caucasus, as well as provides evidence for active faulting along the southern margin of the mountain range.

Gunnels, Michael↗

Geophysical Interpretation of Venus Gravity Data

The subsurface distribution of Venus was investigated through the analysis of the data from Pioneer Venus Orbiter (PVO). In particular, the Doppler tracking data were used to map the gravitational potential. These were compared to the topographic data from the PVO radar (ORAD). In order to obtain an unbiased comparison, the topography data obtained from the PVO-ORAD were filtered to introduce distortions which are the same as those of the gravity models. Both the gravity and filtered topography maps are derived by two stage processes with a common second stage. In the first stage, the topography was used to calculate a corresponding spacecraft acceleration under the assumptions that the topography has a uniform given density and no compensation. In the second stage, the acceleration measures found in the first stage were passed through a linear inverter to yield maps of gravity and topography. Because these maps are the result of the same inversion process, they contain the same distortion; a comparison between them is unbiased to first order.

Reasenberg, R. D.↗

Aircraft automatic-flight-control system with inversion of the model in the feed-forward path using a Newton-Raphson technique for the inversion

A new automatic flight control system concept suitable for aircraft with highly nonlinear aerodynamic and propulsion characteristics and which must operate over a wide flight envelope was investigated. This exact model follower inverts a complete nonlinear model of the aircraft as part of the feed-forward path. The inversion is accomplished by a Newton-Raphson trim of the model at each digital computer cycle time of 0.05 seconds. The combination of the inverse model and the actual aircraft in the feed-forward path alloys the translational and rotational regulators in the feedback path to be easily designed by linear methods. An explanation of the model inversion procedure is presented. An extensive set of simulation data for essentially the full flight envelope for a vertical attitude takeoff and landing aircraft (VATOL) is presented. These data demonstrate the successful, smooth, and precise control that can be achieved with this concept. The trajectory includes conventional flight from 200 to 900 ft/sec with path accelerations and decelerations, altitude changes of over 6000 ft and 2g and 3g turns. Vertical attitude maneuvering as a tail sitter along all axes is demonstrated. A transition trajectory from 200 ft/sec in conventional flight to stationary hover in the vertical attitude includes satisfactory operation through lift-cure slope reversal as attitude goes from horizontal to vertical at constant altitude. A vertical attitude takeoff from stationary hover to conventional flight is also demonstrated.

Smith, G. A.↗

Determination of the area and mass distribution of orbital debris fragments

A technique is described to estimate the area-to-mass ratio of debris fragments using orbital fragments obtained by radar. The area-to-mass ratio of about 2600 fragments arising from the breakup of 24 artificial satellites was determined; an analysis of the data on about 200 objects with known mass, size, and shape has been made, and a calibration of the observed radar cross-section (RCS) to the effective area of these objects has provided a method to estimate the effective area of debris fragments. From the knowledge of the effective area and the estimated area-to-mass ratio, the mass and area distribution of each of the known breakup has been obtained. As a function of time, the orbital elements can be used to invert any propagation algorithm to yield the area-to-mass ratio of an orbiting object.

Badhwar, Gautam D.↗

Supply Chain for Photovoltaics in the United States: 2024 in Review

Solar photovoltaic (PV) and battery energy storage system (BESS) technologies are two immediately available options for meeting U.S. electricity demands, which are increasing due to expansion of loads from end uses including data centers, buildings, vehicles, and factories. Globally, PV and BESS supply chains are dominated by products manufactured in China and elsewhere by Chinese companies. However, U.S. PV and BESS manufacturing have recently grown, with some capacity in each step of the PV supply chain, albeit not enough to currently meet demand with domestic manufacturing alone. This study analyzes U.S. PV supply chains and costs in 2024, for the crystalline silicon and cadmium telluride module supply chains. The full report additionally addresses the PV balance of system, inverter and BESS supply chains. The study concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗