Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Measurement of jet substructure in boosted $t\overline{t}$ events with the ATLAS detector using 140 fb -1 of 13 TeV $pp$ collisions

Measurements of the substructure of top-quark jets are presented, using 140 fb -1 of 13 TeV pp collision data recorded with the ATLAS detector at the LHC. Top-quark jets reconstructed with the anti-k t algorithm with a radius parameter R = 1.0 are selected in top-quark pair ($t\overline{t}$) events where one top quark decays semileptonically and the other hadronically, or where both top quarks decay hadronically. The top-quark jets are required to have transverse momentum p T > 350 GeV, yielding large samples of data events with jet p T values between 350 and 600 GeV. One- and two-dimensional differential cross sections for eight substructure variables, defined using only the charged components of the jets, are measured in a particle-level phase space by correcting for the smearing and acceptance effects induced by the detector. The differential cross sections are compared with the predictions of several Monte Carlo simulations in which top-quark pair-production quantum chromodynamic matrix-element calculations at next-to-leading-order precision in the strong coupling constant α S are passed to leading-order parton shower and hadronization generators. The Monte Carlo predictions for measures of the broadness, and also the two-body structure, of the top-quark jets are found to be in good agreement with the measurements, while variables sensitive to the three-body structure of the top-quark jets exhibit some tension with the measured distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗

Fracture toughness of plasma-sprayed thermal barrier ceramics: Influence of processing, microstructure, and thermal aging

Fracture toughness has become one of the dominant design parameters that dictates the selection of materials and their microstructure to obtain durable thermal barrier coatings (TBCs). Much progress has been made in characterizing the fracture toughness of relevant TBC compositions in bulk form, and it has become apparent that this property is significantly affected by process-induced microstructural defects. In this investigation, a systematic study of the influence of coating microstructure on the fracture toughness of atmospheric plasma sprayed (APS) TBCs has been carried out. Yttria partially stabilized zirconia (YSZ) coatings were fabricated under different spray process conditions inducing different levels of porosity and interfacial defects. Fracture toughness was measured on free standing coatings in as-processed and thermally aged conditions using the double torsion technique. Results indicate significant variance in fracture toughness among coatings with different microstructures including changes induced by thermal aging. Comparative studies were also conducted on an alternative TBC composition, Gd 2 Zr 2 O 7 (GDZ), which as anticipated shows significantly lower fracture toughness compared to YSZ. Furthermore, the results from these studies not only point towards a need for process and microstructure optimization for enhanced TBC performance but also a framework for establishing performance metrics for promising new TBC compositions.

36 MATERIALS SCIENCE↗

Noise suppression in reconstruction of low-Z target megavoltage cone-beam CT images

Purpose: To improve the image contrast-to-noise (CNR) ratio for low-Z target megavoltage cone-beam CT (MV CBCT) using a statistical projection noise suppression algorithm based on the penalized weighted least-squares (PWLS) criterion. Methods: Projection images of a contrast phantom, a CatPhan{sup Registered-Sign} 600 phantom and a head phantom were acquired by a Varian 2100EX LINAC with a low-Z (Al) target and low energy x-ray beam (2.5 MeV) at a low-dose level and at a high-dose level. The projections were then processed by minimizing the PWLS objective function. The weighted least square (WLS) term models the noise of measured projection and the penalty term enforces the smoothing constraints of the projection image. The variance of projection data was chosen as the weight for the PWLS objective function and it determined the contribution of each measurement. An anisotropic quadratic form penalty that incorporates the gradient information of projection image was used to preserve edges during noise reduction. Low-Z target MV CBCT images were reconstructed by the FDK algorithm after each projection was processed by the PWLS smoothing. Results: Noise in low-Z target MV CBCT images were greatly suppressed after the PWLS projection smoothing, without noticeable sacrifice of the spatial resolution. Depending on the choice of smoothing parameter, the CNR of selected regions of interest in the PWLS processed low-dose low-Z target MV CBCT image can be higher than the corresponding high-dose image.Conclusion: The CNR of low-Z target MV CBCT images was substantially improved by using PWLS projection smoothing. The PWLS projection smoothing algorithm allows the reconstruction of high contrast low-Z target MV CBCT image with a total dose of as low as 2.3 cGy.

60 APPLIED LIFE SCIENCES↗

Visibility and artifacts of gold fiducial markers used for image guided radiation therapy of pancreatic cancer on MRI

Purpose: In radiation therapy of pancreatic cancer, tumor alignment prior to each treatment fraction is improved when intratumoral gold fiducial markers (from here onwards: markers), which are visible on computed tomography (CT) and cone beam CT, are used. Visibility of these markers on magnetic resonance imaging (MRI) might improve image registration between CT and magnetic resonance (MR) images for tumor delineation purposes. However, concomitant image artifacts induced by markers are undesirable. The extent of visibility and artifact size depend on MRI-sequence parameters. The authors’ goal was to determine for various markers their potential to be visible and to generate artifacts, using measures that are independent of the MRI-sequence parameters. Methods: The authors selected ten different markers suitable for endoscopic placement in the pancreas and placed them into a phantom. The markers varied in diameter (0.28–0.6 mm), shape, and iron content (0%–0.5%). For each marker, the authors calculated T{sub 2}{sup ∗}-maps and ΔB{sub 0}-maps using MRI measurements. A decrease in relaxation time T{sub 2}{sup ∗} can cause signal voids, associated with visibility, while a change in the magnetic field B{sub 0} can cause signal shifts, which are associated with artifacts. These shifts inhibit accurate tumor delineation. As a measure for potential visibility, the authors used the volume of low T{sub 2}{sup ∗}, i.e., the volume for which T{sub 2}{sup ∗} differed from the background by >15 ms. As a measure for potential artifacts, the authors used the volume for which |ΔB{sub 0}| > 9.4 × 10{sup −8} T (4 Hz). To test whether there is a correlation between visibility and artifact size, the authors calculated the Spearman’s correlation coefficient (R{sub s}) between the volume of low T{sub 2}{sup ∗} and the volume of high |ΔB{sub 0}|. The authors compared the maps with images obtained using a clinical MR-sequence. Finally, for the best visible marker as well as the marker that showed the smallest artifact, the authors compared the phantom data with in vivo MR-images in four pancreatic cancer patients. Results: The authors found a strong correlation (R{sub s} = 1.00, p < 0.01) between the volume of low T{sub 2}{sup ∗} and the volume with high |ΔB{sub 0}|. Visibility in clinical MR-images increased with lower T{sub 2}{sup ∗}. Signal shift artifacts became worse for markers with high |ΔB{sub 0}|. The marker that was best visible in the phantom, a folded marker with 0.5% iron content, was also visible in vivo, but showed artifacts on diffusion weighted images. The marker with the smallest artifact in the phantom, a small, stretched, ironless marker, was indiscernible on in vivo MR-images. Conclusions: Changes in T{sub 2}{sup ∗} and ΔB{sub 0} are sequence-independent measures for potential visibility and artifact size, respectively. Improved visibility of markers correlates strongly to signal shift artifacts; therefore, marker choice will depend on the clinical purpose. When visibility of the markers is most important, markers that contain iron are optimal, preferably in a folded configuration. For artifact sensitive imaging, small ironless markers are best, preferably in a stretched configuration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-134: Optimizing Technical Parameters for Using Atlas Based Automatic Segmentation for Evaluation of Contour Accuracy Experience with Cardiac Structures From NRG Oncology/RTOG 0617

Purpose: Accurate contour delineation is crucial for radiotherapy. Atlas based automatic segmentation tools can be used to increase the efficiency of contour accuracy evaluation. This study aims to optimize technical parameters utilized in the tool by exploring the impact of library size and atlas number on the accuracy of cardiac contour evaluation. Methods: Patient CT DICOMs from RTOG 0617 were used for this study. Five experienced physicians delineated the cardiac structures including pericardium, atria and ventricles following an atlas guideline. The consistency of cardiac structured delineation using the atlas guideline was verified by a study with four observers and seventeen patients. The CT and cardiac structure DICOM files were then used for the ABAS technique.To study the impact of library size (LS) and atlas number (AN) on automatic contour accuracy, automatic contours were generated with varied technique parameters for five randomly selected patients. Three LS (20, 60, and 100) were studied using commercially available software. The AN was four, recommended by the manufacturer. Using the manual contour as the gold standard, Dice Similarity Coefficient (DSC) was calculated between the manual and automatic contours. Five-patient averaged DSCs were calculated for comparison for each cardiac structure.In order to study the impact of AN, the LS was set 100, and AN was tested from one to five. The five-patient averaged DSCs were also calculated for each cardiac structure. Results: DSC values are highest when LS is 100 and AN is four. The DSC is 0.90±0.02 for pericardium, 0.75±0.06 for atria, and 0.86±0.02 for ventricles. Conclusion: By comparing DSC values, the combination AN=4 and LS=100 gives the best performance. This project was supported by NCI grants U24CA12014, U24CA180803, U10CA180868, U10CA180822, PA CURE grant and Bristol-Myers Squibb and Eli Lilly.

60 APPLIED LIFE SCIENCES↗

SU-F-R-06: Traumatic Brachial Plexus Injury Imaging, Developing a Coherent Clinical Protocol From Literature Review Through Practice

Purpose: Medical Physics teams can now play a critical role to help plan and provide studied approaches for traumatic brachial plexus MR imaging (tbpMRI). This is especially important for coordination with uncommon applications, since it is challenging to select the right modality, parameters, and train technologists on the essential components. For this work, we started with a review of the medical literature, performed crossover/volunteer studies to bring tbpMRI to practice with greater image QC and protocol management. Methods: To the best of our knowledge, we reviewed the known searchable domain for tbpMRI. We found 69 total articles since 2000. Articles were evaluated with our published protocol for literature management (LIMES3). Two physicists and two radiologists condensed the information from all articles into a knowledgebase. Results: The initial literature demonstrated great heterogeneity, which was a sign that this area needed greater consistency. Despite inconsistency and imprecision, we extracted the most relevant targets using our long-term experience with protocol development in MSK. We ran volunteers on six different magnets of various field strengths with multiple receiver coils, and rebuilt a coherent protocol for tbpMRI. Our radiologists rated LIMES3 work as superior. We have received referrals from the ER and have conducted four patient evaluations. Conclusion: Traumatic brachial plexus MRI has great possible benefits for patients. This work supports the complexity of tbpMRI scanning. As this is rarely performed, it requires a more diligent protocol workflow, coordination of caregivers, and education within multiple clinical departments. Choosing the correct imaging exam can be critical, as patients can have significant neuropathy and/or paralysis. The LIMES3 protocol is well liked at our institution, and forms the cornerstone of understanding for our work. Our literature management led to a better clinical protocol creation despite the diffuse and inconclusive information presented in the existing medical literature.

60 APPLIED LIFE SCIENCES↗

SU-F-I-32: Organ Doses from Pediatric Head CT Scan

Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the top of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)

60 APPLIED LIFE SCIENCES↗

Determination of asymptotic normalization coefficients for the channel 16 O→ α+ 12 C: excited state 16 O(0 + ; 6.05 MeV)

Asymptotic normalization coefficients (ANC) determine the overall normalization of cross sections of peripheral radiative capture reactions. In the present paper, we treat the ANC C for the virtual decay 16 O(0 + ; 6.05 MeV)→ α+ 12 C(g.s.), the known values of which are characterized by a large spread (0.29 - 1.65) × 10 3 fm -1/2 . The ANC C is found by analytic continuation in energy of the α 12 C s-wave scattering amplitude, known from the phase-shift analysis of experimental data, to the pole corresponding to the 16O bound state and lying in the unphysical region of negative energies. To determine C, two different methods of analytic continuation are used. In the first method, the scattering data are approximated by the sum of polynomials in energy in the physical region and then extrapolated to the pole. The best way of extrapolation is chosen on the basis of the exactly solvable model. Within the second approach, the ANC C is found by solving the Schrödinger equation for the two-body α 12 C potential, the parameters of which are selected from the requirement of the best description of the phase-shift analysis data at a fixed experimental binding energy of 16 O(0 + ; 6.05 MeV) in the α+ 12 C channel. The values of the ANC C obtained within these two methods lie in the interval (886–1139) fm -1/2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematics of the chemical freeze-out line in the high baryon density regime explored at SIS100

The systematic uncertainties of chemical freeze-out fits at SIS100 energies (Au+Au reactions at $\sqrt{s_{NN}}$ = 3 – 5 GeV) are studied using UrQMD simulations. Although hadron production in UrQMD does not occur on a sharp chemical freeze-out hyper-surface, the extracted fit quality is shown to be very good. The extracted chemical parameters depend on the selected hadron species as well as the underlying equation of state (EoS) of the matter. Including light nuclei and anti-protons in the fit increases the expected freeze-out temperature, while a stiffer EoS increases the obtained chemical potential. Similarly, the baryon densities extracted by the thermal fits depend on the choice of hadrons as well as the underlying equation of state. These results are important for the upcoming CBM@FAIR physics program and highlight that a degree of caution is advised when one relates the chemical freeze-out curve to features on the QCD phase diagram like the critical endpoint or a possible phase transition.

Hofmann, Emma Lilith [GSI Helmholtzzentrum für Sch↗

Infrared Optical Constants from Pressed Pellets of Powders: I. Improved n and k Values of (NH4)(2)SO(4)from Single-Angle Reflectance

In combination with other parameters, the real, n(?), and imaginary, k(?), components of the complex refractive index, = n + ik, can be used to simulate the optical properties of a material in different forms, e.g. its infrared spectra. But obtaining reliable values of the optical constants n/k for solid materials is challenging due to the lack of optical quality specimens, usually crystals, large enough to measure. An alternative to crystals is to press the powder into a uniform disk. We have produced pellets from ammonium sulfate, (NH4)2SO4, powder and derived the pellets’ n and k values via single-angle reflectance using a specular reflectance device in combination with a Fourier transform infrared spectrometer. The single-angle technique measures amplitude of light reflected from the material as a function of wavelength over a wide spectral domain; the optical constants are determined from the reflectance data using the Kramers-Kronig relationship. We investigate several parameters associated with the pellets and pellet formation and their effects upon delivering the most reliable n/k values. Parameters studied include pellet diameter, mass and density (void space), drying, grinding, sieving and particle size in the pellet formation, as well as pressing pressure and duration. Of these parameters, using size-selected mixtures of dried, small (< 100 µm) particles and pressing at = 10 tons for at least 30 minutes were found key to forming highly reflective samples. Comparison to two sets of previous literature n(?) and k(?) values obtained from crystalline (NH4)2SO4 both as crystal reflectance as well as extinction spectra of aerosols measured in a flow tube show reasonable agreement, but suggests the present values, as confirmed from two independent techniques, represent a substantial improvement for n/k values for (NH4)2SO4, also demonstrating promise to measure the optical constants of other materials.

Optical constants, index of refraction, single-ang↗

Modeling the Effects of Artificial Drainage on Agriculture-dominated Watersheds using a Fully Distributed Integrated Hydrology Model: Datasets, scripts, model files

This model-data archive supports the research paper that demonstrates the integration of agricultural drainage features—specifically, narrow engineered ditches and tile drains—into a fully distributed, basin-scale integrated surface-subsurface hydrology model (ISSHM), Amanzi-ATS. The model employs innovative computational meshes aligned with agricultural ditches and incorporates the physically based Hooghoudt's drainage equation to simulate tile drainage, offering a novel strategy that enhances the accuracy of hydrological simulations.The archived dataset includes input parameters, model configurations, and select simulation outputs for the Amanzi-ATS model that successfully captured the streamflow patterns in the Portage River Watershed as validated by USGS gauge readings. Jupyter notebook for the preparation of model inputs and post-processing of outputs are also included. The model's predictive performance achieved a normalized Kling-Gupta Efficiency (KGE) of 0.81, surpassing SWAT without the necessity for site-specific calibration.The Amanzi-ATS model presented in this modeL-data archive allows for numerical experiments to explore the shifts in the flow structure under different drainage scenarios. As a tool for advancing the understanding of distributed hydrological responses and nutrient cycling, this archived model provides valuable insights for researchers, modelers, and decision-makers involved in watershed management and environmental modeling.The Watershed Workflow package is implemented in Python3. The Jupyter notebooks can be executed through multiple open-source tools, for example, Anaconda Jupyter Lab, VS Studio Code, etc. Other data files include CSV and HDF5 files, which can be read through Python scripts. The input files for the ATS model, open-source integrated hydrology, and transport model, are in XML format and can be edited in any commonly used text editors.

54 ENVIRONMENTAL SCIENCES↗

Scale-Up Information for Gas-Phase Ammonia Treatment of Uranium in the Vadose Zone at the Hanford Site Central Plateau

Uranium is present in the vadose zone at the Hanford Central Plateau and is of concern for protection of groundwater. The Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau identified gas-phase treatment and geochemical manipulation as potentially effective treatment approaches for uranium and technetium in the Hanford Central Plateau vadose zone. Based on laboratory evaluation, use of ammonia vapor was selected as the most promising uranium treatment candidate for further development and field testing. While laboratory tests have shown that ammonia treatment effectively reduces the mobility of uranium, additional information is needed to enable deployment of this technology for remediation. Of importance for field applications are aspects of the technology associated with effective distribution of ammonia to a targeted treatment zone, understanding the fate of injected ammonia and its impact on subsurface conditions, and identifying effective monitoring approaches. In addition, information is needed to select equipment and operational parameters for a field design. As part of development efforts for the ammonia technology for remediation of vadose zone uranium contamination, field scale-up issues were identified and have been addressed through a series of laboratory and modeling efforts. This report presents a conceptual description for field application of the ammonia treatment process, engineering calculations to support treatment design, ammonia transport information, field application monitoring approaches, and a discussion of processes affecting the fate of ammonia in the subsurface. The report compiles this information from previous publications and from recent research and development activities. The intent of this report is to provide technical information about these scale-up elements to support the design and operation of a field test for the ammonia treatment technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Climate Change Impacts at Department of Defense

This project is aimed at providing the U.S. Department of Defense (DoD) with a comprehensive analysis of the uncertainty associated with generating climate projections at the regional scale that can be used by stakeholders and decision makers to quantify and plan for the impacts of future climate change at specific locations. The merits and limitations of commonly used downscaling models, ranging from simple to complex, are compared, and their appropriateness for application at installation scales is evaluated. Downscaled climate projections are generated at selected DoD installations using dynamic and statistical methods with an emphasis on generating probability distributions of climate variables and their associated uncertainties. The sites selection and selection of variables and parameters for downscaling was based on a comprehensive understanding of the current and projected roles that weather and climate play in operating, maintaining, and planning DoD facilities and installations.

54 ENVIRONMENTAL SCIENCES↗

Technology Implementation Plan: Irradiation Testing and Qualification for Nuclear Thermal Propulsion Fuel

This document is a notional technology implementation plan (TIP) for the development, testing, and qualification of a prototypic fuel element to support design and construction of a nuclear thermal propulsion (NTP) engine, specifically its pre-flight ground test. This TIP outlines a generic methodology for the progression from non-nuclear out-of-pile (OOP) testing through nuclear in-pile (IP) testing, at operational temperatures, flows, and specific powers, of an NTP fuel element in an existing test reactor. Subsequent post-irradiation examination (PIE) will occur in existing radiological facilities. Further, the methodology is intended to be nonspecific with respect to fuel types and irradiation or examination facilities. The goals of OOP and IP testing are to provide confidence in the operational performance of fuel system concepts and provide data to program leadership for system optimization and fuel down-selection. The test methodology, parameters, collected data, and analytical results from OOP, IP, and PIE will be documented for reference by the NTP operator and the appropriate regulatory and oversight authorities. Final full-scale integrated testing would be performed separately by the reactor operator as part of the preflight ground test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Throughput Combinatorial Development of High-Entropy Alloys For Light-Weight Structural Applications

The primary limitation of today’s lightweight structural alloys is that specific yield strengths (SYS) higher than 200MPa x cc/g (typical value for titanium alloys) are extremely difficult to achieve. This holds true especially at a cost lower than 5dollars/kg (typical value for magnesium alloys). Recently, high-entropy alloys (HEA) have shown promising SYS, yet the large composition space of HEA makes screening compositions complex and time-consuming. Over the course of this 2-year project we started from 150 billion compositions and reduced the number of potential low-density (<5g/cc), low-cost (<5dollars/kg) high-entropy alloy (LDHEA) candidates that are single-phase, disordered, solid-solution (SPSS) to a few thousand compositions. This was accomplished by means of machine learning to guide design for SPSS LDHEA based on a combination of recursive partitioning, an extensive, experimental HEA database compiled from 24 literature sources, and 91 calculated parameters serving as phenomenological selection rules. Machine learning shows an accuracy of 82% in identifying which compositions of a separate, smaller, experimental HEA database are SPSS HEA. Calculation of Phase Diagrams (CALPHAD) shows an accuracy of 71-77% for the alloys supported by the CALPHAD database, where 30% of the compiled HEA database is not supported by CALPHAD. In addition to machine learning, and CALPHAD, a third tool was developed to aid design of SPSS LDHEA. Phase diagrams were calculated by constructing the Gibbs-free energy convex hull based on easily accessible enthalpy and entropy terms. Surprisingly, accuracy was 78%. Pursuing these LDHEA candidates by high-throughput experimental methods resulted in SPSS LDHEA composed of transition metals (e.g. Cr, Mn, Fe, Ni, Cu) alloyed with Al, yet the high concentration of Al, necessary to bring the mass density below 5.0g/cc, makes these materials hard and brittle, body-centered-cubic (BCC) alloys. A related, yet multi-phase BCC alloy, based on Al-Cr-Fe-Ni, shows compressive strain >10% and specific compressive yield strength of 229 MPa x cc/g, yet does not show ductility in tensile tests due to cleavage. When replacing Cr in Al-Cr-Fe-based 4- and 5-element LDHEA with Mn, hardness drops 2x. Combined with compression test results, including those on the ternaries Al-Cr-Fe and Al-Mn-Fe suggest that Al-Mn-Fe-based LDHEA are still worth pursuing. These initial results only represent one compressive stress-strain curve per composition without any property optimization. As such, reproducibility needs to be followed by optimization to show their full potential. When including Li, Mg, and Zn, single-phase Li-Mg-Al-Ti-Zn LDHEA has been found with a specific ultimate compressive strength of 289MPa x cc/g. Al-Ti-Mn-Zn showed a specific ultimate compressive strength of 73MPa x cc/g. These initial results after hot isostatic pressing (HIP) of the ball-milled powders represent the lower end of what is possible, since no secondary processing (e.g. extrusion) has been performed to optimize strength and ductility. Compositions for multi-phase (e.g. dual-phase) LDHEA were identified largely by automated searches through CALPHAD databases, while screening for large face-centered-cubic (FCC) volume fractions, followed by experimental verification. This resulted in several new alloys. Li-Mg-Al-Mn-Fe and Mg-Mn-Fe-Co ball-milled powders upon HIP show specific ultimate compressive strengths of 198MPa x cc/g and 45MPa x cc/g, respectively. Several malleable quarternary Al-Zn-based alloys have been found upon arc/induction melting, yet with limited specific compressive yield strength (<75 MPa x cc/g). These initial results are all without any optimization for strength and/or ductility. High-throughput experimentation allowed us to triple the existing experimental HEA database as published in the past 10 years in less than 2 years which happened at a rate 10x higher than previous methods. Furthermore, we showed that high-throughput thin-film combinatorial methods can be used to get insight in isothermal phase diagram slices. Although it is straightforward to map hardness as a function of composition for sputtered, thin-film, compositional gradients by nano-indentation and compare the results to micro-indentation on bulk samples, the simultaneous impact of composition, roughness, film density, and microstructure on hardness requires monitoring all these properties as a function of location on the compositional gradient, including dissecting the impact of these 4 factors on the hardness map. These additional efforts impact throughput significantly. This work shows that a lot of progress has been made over the years in predicting phase formation that aids the discovery of new alloys, yet that a lot of work needs to be done to predict phases more accurately for LDHEA, whether done by CALPHAD or by other means. More importantly, more work needs to be done to predict mechanical properties of novel alloys, like yield strength, and ductility. Furthermore, this work shows that there is a need for the generation of an empirical alloy database covering strategic points in a multi-dimensional composition space to allow for faster and more accurate predictive interpolations to identify the oasis in the dessert more quickly. Finally, this work suggests that it is worth pursuing a ductile alloy with a SYS > 300 MPa x cc/g in a mass density range of 6-7 g/cc, since the chances for a single-phase or majority-phase FCC increase significantly. Today’s lightweight steels are in this density range.

36 MATERIALS SCIENCE↗

Bayesian Hierarchical Models for Parameter Inference with Missing Data: Supernova Cosmology Case Study [Slides]

Large scale astronomical surveys are going wider and deeper than ever before. However, astronomers, cosmologists and theorists continue to face the perennial issue that their data sets are often incomplete in magnitude space and must be carefully treated in order to avoid Malmquist bias, especially in the field of supernova cosmology. Historically, cosmological parameter inference in supernova cosmology was done using χ2 methodology; however, recent years have seen a rise in the use of Bayesian Hierarchical Models. In this presentation we develop a Bayesian Hierarchical methodology to account for magnitude limited surveys and present a specific application to cosmological parameter inference and model selection in supernova cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct conversion of Light Hydrocarbons to Olefins (Final report)

Reaction35 is developing a new industrial process that is substantially different from the traditional standalone dehydrogenation process practiced in industry such as Oleflex® and Catofin®. Those processes have substantial energy consumption and loss of feed constraints. The Reaction35 process is based on using molecular bromine to activate the alkane (e.g., nbutane) by forming highly reactive butyl bromides. The butyl bromides are easily converted to nbutylenes (final product) and hydrogen bromide. The hydrogen bromide generated in bromination and dehydrobromination is oxidized with air, recovering the molecular bromine which is reused. The overall result is a process with a favorably low energy consumption and less than 1 % overall loss of feed compared to more than 5 % for the direct dehydrogenation processes. During the grant period, several important aspects of the technology have been developed further. The major effort was the hydrogenation catalyst step development. The hydrogenation catalyst is used for recovery of the polybromobutanes to the bromobutanes intermediates. The scientific field regarding dibromo- and polybromoalkanes has not been extensively studied, which necessitated that Reaction35 performs a full study of a number of catalysts and the various experimental conditions that influence the hydrogenation reaction. Currently, Reaction35 has completed its catalyst selection and preliminary experimental parameters optimization. This will allow for the construction of an engineering model for a pilot unit testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗