Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

NEUTRON MEASUREMENTS AT HANFORD’S PLUTONIUM FINISHING PLANT

The Pacific Northwest National Laboratory (PNNL) conducted neutron measurements at Hanford’s Plutonium Finishing Plant (PFP). The measurements were performed to evaluate the performance of the Hanford Standard Dosimeter (HSD) and the 8816 TLD component of the Hanford Combination Neutron Dosimeter (HCND) in the neutron fields responsible for worker neutron exposures. For this study, TEPC detectors and multisphere spectrometers were used to measure neutron dose equivalent rate, and multispheres were used to measure average neutron energy. Water-filled phantoms holding Hanford dosimeters were positioned at each measurement location. The phantoms were positioned in the same location where a multisphere measurement was taken and TEPCs were also positioned there. Plant survey meters were also used to measure neutron dose rates at all locations. Three measurement locations were chose near the HC-9B glovebox in room 228A of Building 234-5. The multisphere spectrometers measured average neutron energies in the range of 337 to 555 keV at these locations. Personal dose equivalent, Hp(10)n, as measured by the multisphere and TEPC, ranged from 2.7 to 9.7 mrem/h in the three locations. Effective dose assuming a rotational geometry (EROT) was substantially lower than Hp(10), ranging from 1.3 to 3.6 mrem/h. These values were lower than the reported values from dosimeters exposed on a rotating phantom. Effective dose assuming an AP geometry (EAP) was also substantially lower than Hp(10), ranging from 2.3 to 6.5 mrem/h. These values were lower than the reported values from the dosimeters on slab phantoms. Since the effective dose values were lower than reported values from dosimeters, the dosimeters were shown to be conservative estimates of the protection quantities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of polychromatic attenuation using computed tomography reconstructed images

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

NASA Discipline Musculoskeletal↗

Dosimetric Comparison in Breast Radiotherapy of 4 MV and 6 MV on Physical Chest Simulator

According to the World Health Organization (2014) breast cancer is the main cause of death by cancer in women worldwide. The biggest challenge of radiotherapy in the treatment of cancer is to deposit the entire prescribed dose homogeneously in the breast, sparing the surrounding tissue. In this context, this paper aimed at evaluating and comparing internal dose distribution in the mammary gland based on experimental procedures submitted to two distinct energy spectra produced in breast cancer radiotherapy. The methodology consisted of reproducing opposite parallel fields used in the treatment of breast tumors in a chest phantom. This simulator with synthetic breast, composed of equivalent tissue material (TE), was previously developed by the NRI Research Group (UFMG). The computer tomography (CT) scan of the simulator was obtained antecedently. The radiotherapy planning systems (TPS) in the chest phantom were performed in the ECLIPSE system from Varian Medical Systems and CAT 3D system from MEVIS. The irradiations were reproduced in the Varian linear accelerator, model SL- 20 Precise, 6 MV energy and Varian linear accelerator, 4 MV Clinac 6x SN11 model. Calibrations of the absorbed dose versus optical density from radiochromic films were generated in order to obtain experimental dosimetric distribution at the films positioned within the glandular and skin equivalent tissues of the chest phantom. The spatial dose distribution showed equivalence with the TPS on measurement data performed in the 6 MV spectrum. The average dose found in radiochromic films placed on the skin ranged from 49 to 79%, and from 39 to 49% in the mammary areola, for the prescribed dose. Dosimetric comparisons between the spectra of 4 and 6 MV, keeping the constant geometry of the fields applied in the same phantom, will be presented showing their equivalence in breast radiotherapy, as well as the variations will be discussed. To sum up, the dose distribution has reached the value expected in the breast dose of the 180 cGy in a wide range of the film in the glandular TE in both spectra. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Photon Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries - Paper 148

With the introduction of new recommendations of the ICRP in Publication 103 the methodology for determining the protection quantity effective dose has been modified. The modifications include changes in organ/tissue weighting factors as well as some changes in radiation weighting factors. Computations of protection dose coefficients now require the use of reference male and female voxel phantoms, see ICRP Publication 110. Computations of equivalent doses in organs and tissues are now performed in each phantom and the average is used to compute the effective dose. The latest set of external dose coefficients using the new reference phantoms and the latest guidance from the ICRP were performed by the ICRP DOCAL task group and reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Report 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). For all geometries, except the ISO geometry, parallel beams are used to compute the dose coefficients. In this paper, the methodology of ICRP Publication 116 was used to compute dose coefficients for photons for irradiations of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace for personnel standing on contaminated surfaces or volumes and from overhead sources. In this work calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. Dose coefficients for caudal and cranial irradiation geometries have been calculated in accordance with ICRP Publication 103. The coefficients differ significantly from AP values for both organ and tissues of ICRP Publication 116, as would be expected. For workers in these scenarios organ and effective doses can differ significantly from AP values. For common photon energies (i.e. 100 keV to a few MeV) the AP effective dose overestimates the caudal and cranial values by about a factor of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

Organ and effective dose rate coefficients for submersion exposure in occupational settings

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.

61 RADIATION PROTECTION AND DOSIMETRY↗

Breath-Hold Target Localization With Simultaneous Kilovoltage/Megavoltage Cone-Beam Computed Tomography and Fast Reconstruction

Purpose: Hypofractionated high-dose radiotherapy for small lung tumors has typically been based on stereotaxy. Cone-beam computed tomography and breath-hold techniques have provided a noninvasive basis for precise cranial and extracranial patient positioning. The cone-beam computed tomography acquisition time of 60 s, however, is beyond the breath-hold capacity of patients, resulting in respiratory motion artifacts. By combining megavoltage (MV) and kilovoltage (kV) photon sources (mounted perpendicularly on the linear accelerator) and accelerating the gantry rotation to the allowed limit, the data acquisition time could be reduced to 15 s. Methods and Materials: An Elekta Synergy 6-MV linear accelerator, with iViewGT as the MV- and XVI as the kV-imaging device, was used with a Catphan phantom and an anthropomorphic thorax phantom. Both image sources performed continuous image acquisition, passing an angle interval of 90{sup o} within 15 s. For reconstruction, filtered back projection on a graphics processor unit was used. It reconstructed 100 projections acquired to a 512 x 512 x 512 volume within 6 s. Results: The resolution in the Catphan phantom (CTP528 high-resolution module) was 3 lines/cm. The spatial accuracy was within 2-3 mm. The diameters of different tumor shapes in the thorax phantom were determined within an accuracy of 1.6 mm. The signal-to-noise ratio was 68% less than that with a 180{sup o}-kV scan. The dose generated to acquire the MV frames accumulated to 82.5 mGy, and the kV contribution was <6 mGy. Conclusion: The present results have shown that fast breath-hold, on-line volume imaging with a linear accelerator using simultaneous kV-MV cone-beam computed tomography is promising and can potentially be used for image-guided radiotherapy for lung cancer patients in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Real-Time Tumor Position Monitoring and Dynamic Multileaf Collimator Tracking Using a Siemens 160 MLC: Geometric and Dosimetric Accuracy of an Integrated System

Purpose: Dynamic multileaf collimator tracking represents a promising method for high-precision radiotherapy to moving tumors. In the present study, we report on the integration of electromagnetic real-time tumor position monitoring into a multileaf collimator-based tracking system. Methods and Materials: The integrated system was characterized in terms of its geometric and radiologic accuracy. The former was assessed from portal images acquired during radiation delivery to a phantom in tracking mode. The tracking errors were calculated from the positions of the tracking field and of the phantom as extracted from the portal images. Radiologic accuracy was evaluated from film dosimetry performed for conformal and intensity-modulated radiotherapy applied to different phantoms moving on sinusoidal trajectories. A static radiation delivery to the nonmoving target served as a reference for the delivery to the moving phantom with and without tracking applied. Results: Submillimeter tracking accuracy was observed for two-dimensional target motion despite the relatively large system latency of 500 ms. Film dosimetry yielded almost complete recovery of a circular dose distribution with tracking in two dimensions applied: 2%/2 mm gamma-failure rates could be reduced from 59.7% to 3.3%. For single-beam intensity-modulated radiotherapy delivery, accuracy was limited by the finite leaf width. A 2%/2 mm gamma-failure rate of 15.6% remained with tracking applied. Conclusion: The integrated system we have presented marks a major step toward the clinical implementation of high-precision dynamic multileaf collimator tracking. However, several challenges such as irregular motion traces or a thorough quality assurance still need to be addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4{sup o}. For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22{sup o}). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be accurate, and its registration matrix can be easily translated into the TPS and a low dose is delivered to the patient during image acquisition. These results can help in designing imaging protocols for offline evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

The quintom model with O(N) symmetry

We investigate the quintom model of dark energy in the generalized case where the corresponding canonical and phantom fields possess O(N) symmetries. Assuming exponential potentials we find that this O(N) quintom paradigm exhibits novel properties comparing to the simple canonical and phantom scenarios. In particular, we find that the universe cannot result in a quintessence-type solution with w>-1, even in the cases where the phantom field seems to be irrelevant. On the contrary, there are always late-time attractors which correspond to accelerating universes with w<-1 and with a recent crossing of the phantom divide, and for a very large area of the parameter space they are the only ones. This is in contrast with the previous simple quintom results, where an accelerating universe is a possible late-time stable solution but it is not guaranteed.

79 ASTRONOMY AND ASTROPHYSICS↗

Clinical evaluations of an amplitude-based binning algorithm for 4DCT reconstruction in radiation therapy

Purpose: Phase-binning algorithms are commonly utilized in 4DCT image reconstruction for characterization of tumor or organ shape and respiration motion, but breathing irregularities occurring during 4DCT acquisition can cause considerable image distortions. Recently, amplitude-binning algorithms have been evaluated as a potential improvement to phase-binning algorithms for 4DCT image reconstruction. The purpose of this study was to evaluate the performance of the first commercially available on-line retrospective amplitude-binning algorithm for comparison to the traditional phase-binning algorithm. Methods: Both phantom and clinical data were used for evaluation. A phantom of known geometry was mounted on a 4D motion platform programmed with seven respiratory waves (two computer generated and five patient trajectories) and scanned with a Philips Brilliance Big bore 16-slice CT simulator. 4DCT images were reconstructed using commercial amplitude- and phase-binning algorithms. Image quality of the amplitude- and phase-binned image sets was compared by evaluation of shape and volume distortions in reconstructed images. Clinical evaluations were performed on 64 4DCT patient image sets in a blinded review process. The amplitude- and phase-binned 4DCT maximum intensity projection (MIP) images were further evaluated for 28 stereotactic body radiation therapy (SBRT) cases of total 64 cases. A preliminary investigation of the effects of respiratory amplitude and pattern irregularities on motion artifact severity was conducted. Results: The phantom experiments illustrated that, as expected, maximum inhalation occurred at the 0% amplitude and maximum exhalation occurred at the 50% amplitude of the amplitude-binned 4DCT image sets. The phantom shape distortions were more severe in the images reconstructed from the phase-binning algorithm. In the clinical study, compared to the phase-binning algorithm, the amplitude-binning algorithm yielded fewer or less severe motion artifacts in 37.5% of the cases (24/64), comparable artifacts in 54.7% of the cases (35/64), and slightly greater artifacts in 7.8% of the cases (5/64). Evaluation of SBRT cases demonstrated that the reconstructed tumor sizes and locations were comparable in 96% (1/28) of the MIP image pairs generated from both amplitude- and phase-binning algorithms. In this case the amplitude-binned image set rendered a smaller tumor size, which was likely due to very shallow respiratory amplitudes occurring over several breathing cycles. Conclusions: Overall, the amplitude-binning algorithm for 4DCT reconstruction reduced the severity of tumor distortion and image artifacts compared to the phase-binning algorithm. However, the full range of motion may not be characterized using amplitude-binning algorithms. Despite superior performance, amplitude binning can still be susceptible to motion artifacts caused by large variations in amplitude of respiratory waves.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A scintillator-based approach to monitor secondary neutron production during proton therapy

Here, the primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response for comparison to the measured data. Comparison of the measured and simulated data will validate this approach for monitoring secondary neutron dose during proton therapy. Proton beams of 155- and 200-MeV were used to irradiate a variety of phantom materials and secondary particles were detected using organic liquid scintillators. These detectors are sensitive to fast neutrons and gamma rays: pulse shape discrimination was used to classify each detected pulse as either a neutron or a gamma ray. The mcnpx-PoliMi code was used to simulate the secondary neutron field produced during proton irradiation of the same tissue-equivalent phantom materials. As a result, an experiment was performed at the Loma Linda University Medical Center proton therapy research beam line and corresponding models were created using the mcnpx-PoliMi code. The authors’ analysis showed agreement between the simulations and the measurements. The simulated detector response can be used to validate the simulations of neutron and gamma doses on a particular beam line with or without a phantom. In conclusion, the authors have demonstrated a method of monitoring the neutron component of the secondary radiation field produced by therapeutic protons. The method relies on direct detection of secondary neutrons and gamma rays using organic scintillation detectors. These detectors are sensitive over the full range of biologically relevant neutron energies above 0.5 MeV and allow effective discrimination between neutron and photon dose. Because the detector system is portable, the described system could be used in the future to evaluate secondary neutron and gamma doses on various clinical beam lines for commissioning and prospective data collection in pediatric patients treated with proton therapy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CTT: Tools for Fine Alignment of Flash X-ray Systems

The CTT code is a compilation of the python code that was prototyped in the interest of making a method for fine alignment of Flash X-ray Systems at the lab. It contains python code for interacting with LTT and running optimization loops using LTT simulations or ray tracing with RaySpace. It Includes classes for creating phantom objects and modular geometry objects in the simulations. It allows one to generate a random phantom that has been optimized to stay with a certain cubic volume and maximize the minimum distance between any two ball phantom centers in all projections. It was primarily made to work on ball phantoms which were simulated as Teflon spheres. It allows the alignment from some nominal position to some displaced position to simulate recovery of a real geometry from the nominal geometry of the system. Fine alignment can be done with the projections in LTT while a rough alignment is faster using rayspace. If rayspace works well for the use case it should be preferred since it is considerably faster and less resource intensive in general. Some Notes about using this code is that one will have to edit the imports for the files to get to the correct LTT path, LTT GUI path and to the CTT path when importing. This was made by using anaconda with python 3 on windows 10. The LTT code was stored in a anaconda environment which seemed to help the python find the LTT although it shouldn’t be necessary if you append the path in your code using sys.path.append(r'add the path you want here’). The sys.path.append method is a quick way to give your python code access to a given folder when running it (such as LTT or CTT). Note that since the code was originally made with paths for a specific machine that a new user will have to edit those paths to make it work in all the files that use the old paths. This is somewhat tedious but will be required to run the code on a new machine. The methodology used to run and make these notebooks starts with opening a command prompt as administrator in windows 10. After this one would activate the anaconda environment in the appropriate directory using “conda activate myenv” in the command prompt. After this open a jupyter-notebook using the keyword “jupyter-notebook". After that a notebook should open in a browser. Note that some libraries used may not come with anaconda so those may have to be installed. There shouldn’t be much though since the main things used are scipy, numpy, matplotlib, and LTT. LTTQuicksetup also requires some paths that will be specific to the computer so that should be changed as well.

42 ENGINEERING↗

Accurate Measurement of Bone Density with QCT

The objective of this study was to determine the accuracy of bone density measurement with a new OCT technology. A phantom was fabricated using two materials, a water-equivalent compound and hydroxyapatite (HA), combined in precise proportions (QRM GrnbH, Germany). The phantom was designed to have the approximate physical size and range in bone density as a human calcaneus, with regions of 0, 50, 100, 200, 400, and 800 mg/cc HA. The phantom was scanned at 80, 120 and 140 KVp with a GE CT/i HiSpeed Advantage scanner. A ring of highly attenuating material (polyvinyl chloride or teflon) was slipped over the phantom to alter the image by introducing non-axi-symmetric beam hardening. Images were corrected with a new OCT technology using an estimate of the effective X-ray beam spectrum to eliminate beam hardening artifacts. The algorithm computes the volume fraction of HA and water-equivalent matrix in each voxel. We found excellent agreement between expected and computed HA volume fractions. Results were insensitive to beam hardening ring material, HA concentration, and scan voltage settings. Data from all 3 voltages with a best fit linear regression are displays.

Cleek, Tammy M.↗

Characterization of the Radiation Shielding Properties of U.S. and Russian Extravehicular Activity Suits

Reported herein are results from the Eril Research, Inc. (ERI) participation in the JSC-sponsored study characterizing the radiation shielding properties of the two types of space suit that astronauts are wearing during the EVA on-orbit assembly of ISS. Measurements using passive detectors were carried out to assess the shielding properties of the U.S. EMU Suit and the Russian Orlan-M suit during irradiations of the suits and a tissue-equivalent phantom to monoenergetic proton and electron beams at LLUMC. During irradiations of 6 MeV electrons and 60 MeV protons, absorbed dose as a function of depth was measured using TLDs exposed behind swatches of the two suit materials and inside the two EVA helmets. Considerable reduction in electron dose was measured behind all suit materials in exposures to 6 MeV electrons. Slowing of the proton beam in the suit materials led to an increase in dose measured in exposures to 60 MeV protons. During 232 MeV proton irradiations, measurements were made with TLDs and CR-39 PNTDs at five organ locations inside a tissue-equivalent phantom, exposed both with and without the two EVA suits. The EVA helmets produce a 13% to 27% reduction in total dose and a 0% to 25% reduction in dose equivalent when compared to measurements made in the phantom head alone. Differences in dose and dose equivalent between the suit and non-suit irradiations for the lower portions of the two EVA suits tended to be smaller. Proton-induced target fragmentation was found to be a significant source of increased dose equivalent, especially within the two EVA helmets, and average quality factor inside the EMU and Orlan-M helmets was 2% to 14% greater than that measured in the bare phantom head.

Benton, E. R.↗

Improvements to the Ionizing Radiation Risk Assessment Program for NASA Astronauts

To perform dosimetry and risk assessment, NASA collects astronaut ionizing radiation exposure data from space flight, medical imaging and therapy, aviation training activities and prior occupational exposure histories. Career risk of exposure induced death (REID) from radiation is limited to 3 percent at a 95 percent confidence level. The Radiation Health Office at Johnson Space Center (JSC) is implementing a program to integrate the gathering, storage, analysis and reporting of astronaut ionizing radiation dose and risk data and records. This work has several motivations, including more efficient analyses and greater flexibility in testing and adopting new methods for evaluating risks. The foundation for these improvements is a set of software tools called the Astronaut Radiation Exposure Analysis System (AREAS). AREAS is a series of MATLAB(Registered TradeMark)-based dose and risk analysis modules that interface with an enterprise level SQL Server database by means of a secure web service. It communicates with other JSC medical and space weather databases to maintain data integrity and consistency across systems. AREAS is part of a larger NASA Space Medicine effort, the Mission Medical Integration Strategy, with the goal of collecting accurate, high-quality and detailed astronaut health data, and then securely, timely and reliably presenting it to medical support personnel. The modular approach to the AREAS design accommodates past, current, and future sources of data from active and passive detectors, space radiation transport algorithms, computational phantoms and cancer risk models. Revisions of the cancer risk model, new radiation detection equipment and improved anthropomorphic computational phantoms can be incorporated. Notable hardware updates include the Radiation Environment Monitor (which uses Medipix technology to report real-time, on-board dosimetry measurements), an updated Tissue-Equivalent Proportional Counter, and the Southwest Research Institute Radiation Assessment Detector. Also, the University of Florida hybrid phantoms, which are flexible in morphometry and positioning, are being explored as alternatives to the current NASA computational phantoms.

Semones, E. J.↗