Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Optimizing Radiation Therapy Quality Assurance in Clinical Trials: A TROG 08.03 RAVES Substudy

Purpose: To explore site- and clinician-level factors associated with protocol violations requiring real-time-review (RTR) resubmission in a multicenter clinical trial to help tailor future quality assurance (QA) protocols. Methods and Materials: RAVES (Radiation Therapy–Adjuvant vs Early Salvage) (Trans-Tasman Radiation Oncology Group 08.03) is a randomized trial comparing adjuvant with early salvage radiation therapy in men with positive surgical margins or pT3 disease after prostatectomy. Quality assurance in RAVES required each clinician and site to submit a credentialing dummy run (DR) and for each patient's radiation therapy plan to undergo external RTR before treatment. Prospectively defined major violations from trial protocol required remedy and resubmission. Site and clinician factors associated with RTR resubmission were examined using hierarchical modeling. Results: Data were collected from 171 consecutive patients, treated by 46 clinicians at 32 hospitals. There were 47 RTR resubmissions (27%) due to 65 major violations. The relative rate of resubmission decreased by 29% per year as the study progressed (odds ratio OR. 0.71, P=.02). The majority of resubmissions were due to contouring violations (39 of 65) and dosimetric violations (22 of 65). For each additional patient accrued, significant decreases in RTR resubmission were seen at both clinician level (OR 0.75, P=.02) and site level (OR 0.72, P=.01). The rate of resubmission due to dosimetric violations was only 1.6% after the first 5 patients. Use of IMRT was associated with lower rates of resubmission compared with 3-dimensional conformal radiation therapy (OR 0.38, P=.05). Conclusion: Several low- and high-risk factors that may assist with tailoring future clinical trial QA were identified. Because the real-time resubmission rate was largely independent of the credentialing exercise, some form of RTR QA is recommended. The greatest benefit from QA was derived early in trial activation and clinician experience.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience and Evaluation of Patient Treatment Verification With a Transit Dosimeter

Purpose: To prospectively evaluate a protocol for transit dosimetry on a patient population undergoing intensity modulated radiation therapy (IMRT) and to assess the issues in clinical implementation of electronic portal imaging devices (EPIDs) for treatment verification. Methods and Materials: Fifty-eight patients were enrolled in the study. Amorphous silicon EPIDs were calibrated for dose and used to acquire images of delivered fields. Measured EPID dose maps were back-projected using the planning computed tomographic (CT) images to calculate dose at prespecified points within the patient and compared with treatment planning system dose offline using point dose difference and point γ analysis. The deviation of the results was used to inform future action levels. Results: Two hundred twenty-five transit images were analyzed, composed of breast, prostate, and head and neck IMRT fields. Patient measurements demonstrated the potential of the dose verification protocol to model dose well under complex conditions: 83.8% of all delivered beams achieved the initial set tolerance level of Δ{sub D} of 0 ± 5 cGy or %Δ{sub D} of 0% ± 5%. Importantly, the protocol was also sensitive to anatomic changes and spotted that 3 patients from 20 measured prostate patients had undergone anatomic change in comparison with the planning CT. Patient data suggested an EPID-reconstructed versus treatment planning system dose difference action level of 0% ± 7% for breast fields. Asymmetric action levels were more appropriate for inversed IMRT fields, using absolute dose difference (−2 ± 5 cGy) or summed field percentage dose difference (−6% ± 7%). Conclusions: The in vivo dose verification method was easy to use and simple to implement, and it could detect patient anatomic changes that impacted dose delivery. The system required no extra dose to the patient or treatment time delay and so could be used throughout the course of treatment to identify and limit systematic and random errors in dose delivery for patient groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark Credentialing Results for NRG-BR001: The First National Cancer Institute-Sponsored Trial of Stereotactic Body Radiation Therapy for Multiple Metastases

Purpose: The NRG-BR001 trial is the first National Cancer Institute–sponsored trial to treat multiple (range 2-4) extracranial metastases with stereotactic body radiation therapy. Benchmark credentialing is required to ensure adherence to this complex protocol, in particular, for metastases in close proximity. The present report summarizes the dosimetric results and approval rates. Methods and Materials: The benchmark used anonymized data from a patient with bilateral adrenal metastases, separated by <5 cm of normal tissue. Because the planning target volume (PTV) overlaps with organs at risk (OARs), institutions must use the planning priority guidelines to balance PTV coverage (45 Gy in 3 fractions) against OAR sparing. Submitted plans were processed by the Imaging and Radiation Oncology Core and assessed by the protocol co-chairs by comparing the doses to targets, OARs, and conformity metrics using nonparametric tests. Results: Of 63 benchmarks submitted through October 2015, 94% were approved, with 51% approved at the first attempt. Most used volumetric arc therapy (VMAT) (78%), a single plan for both PTVs (90%), and prioritized the PTV over the stomach (75%). The median dose to 95% of the volume was 44.8 ± 1.0 Gy and 44.9 ± 1.0 Gy for the right and left PTV, respectively. The median dose to 0.03 cm{sup 3} was 14.2 ± 2.2 Gy to the spinal cord and 46.5 ± 3.1 Gy to the stomach. Plans that spared the stomach significantly reduced the dose to the left PTV and stomach. Conformity metrics were significantly better for single plans that simultaneously treated both PTVs with VMAT, intensity modulated radiation therapy, or 3-dimensional conformal radiation therapy compared with separate plans. No significant differences existed in the dose at 2 cm from the PTVs. Conclusions: Although most plans used VMAT, the range of conformity and dose falloff was large. The decision to prioritize either OARs or PTV coverage varied considerably, suggesting that the toxicity outcomes in the trial could be affected. Several benchmarks met the dose-volume histogram metrics but produced unacceptable plans owing to low conformity. Dissemination of a frequently-asked-questions document improved the approval rate at the first attempt. Benchmark credentialing was found to be a valuable tool for educating institutions about the protocol requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase 1/2 Trial of a Combination of Paclitaxel and Trastuzumab With Daily Irradiation or Paclitaxel Alone With Daily Irradiation After Transurethral Surgery for Noncystectomy Candidates With Muscle-Invasive Bladder Cancer (Trial NRG Oncology RTOG 0524)

Purpose: Bladder preservation therapy is an effective treatment for muscle-invasive urothelial carcinoma (UC). In this study we treated noncystectomy candidates with daily radiation and weekly paclitaxel for 7 weeks. Patients whose tumors showed her2/neu overexpression were additionally treated with weekly trastuzumab. Methods and Materials: Sixty-eight evaluable patients were treated with radiation therapy and either paclitaxel + trastuzumab (group 1) or paclitaxel alone (group 2). Groups were assigned on the basis of her2/neu immunohistochemistry results. Patients received 1.8-Gy fractions to a total dose of 64.8 Gy. The primary endpoint of the study was treatment-related toxicity, and secondary endpoints included complete response (CR) rate, protocol completion rate, and survival. Results: A total of 20 evaluable patients were treated in group 1 and 46 patients in group 2. Acute treatment-related adverse events (AEs) were observed in 7 of 20 patients in group 1 (35%) and 14 of 46 patients in group 2 (30.4%). Protocol therapy was completed by 60% (group 1) and 74% (group 2) of patients. Most incompletions were due to toxicity, and the majority of AEs were gastrointestinal, including 1 grade 5 AE (group 1). Two other deaths (both in group 2) were unrelated to protocol therapy. No unexpected cardiac, hematologic, or other toxicities were observed. The CR rate at 1 year was 72% for group 1 and 68% for group 2. Conclusions: In patients with muscle-invasive UC who are not candidates for cystectomy, daily radiation combined with paclitaxel is an effective treatment strategy with a high completion rate and moderate toxicity. In patients with her2/neu-positive tumors, a group generally considered to have worse outcomes, the addition of trastuzumab appears to result in comparable efficacy and toxicity. Further biomarker-driven trials should be undertaken in advancing treatment of this challenging disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Particle Therapy Using Protons or Carbon Ions for Unresectable or Incompletely Resected Bone and Soft Tissue Sarcomas of the Pelvis

Purpose: To retrospectively analyze the treatment outcomes of particle therapy using protons or carbon ions for unresectable or incompletely resected bone and soft tissue sarcomas (BSTSs) of the pelvis. Methods and Materials: From May 2005 to December 2014, 91 patients with nonmetastatic histologically proven unresectable or incompletely resected pelvic BSTSs underwent particle therapy with curative intent. The particle therapy used protons (52 patients) or carbon ions (39 patients). All patients received a dose of 70.4 Gy (relative biologic effectiveness) in 32 fractions (55 patients) or 16 fractions (36 patients). Results: The median patient age was 67 years (range 18-87). The median planning target volume (PTV) was 455 cm{sup 3} (range 108-1984). The histologic type was chordoma in 53 patients, chondrosarcoma in 14, osteosarcoma in 10, malignant fibrous histiocytoma/undifferentiated pleomorphic sarcoma in 5, and other in 9 patients. Of the 91 patients, 82 had a primary tumor and 9 a recurrent tumor. The median follow-up period was 32 months (range 3-112). The 3-year rate of overall survival (OS), progression-free survival (PFS), and local control was 83%, 72%, and 92%, respectively. A Cox proportional hazards model revealed that chordoma histologic features and a PTV of ≤500 cm{sup 3} were significantly associated with better OS, and a primary tumor and PTV of ≤500 cm{sup 3} were significantly associated with better PFS. Ion type and number of fractions were not significantly associated with OS, PFS, or local control. Late grade ≥3 toxicities were observed in 23 patients. Compared with the 32-fraction protocol, the 16-fraction protocol was associated with significantly more frequent late grade ≥3 toxicities (18 of 36 vs 5 of 55; P<.001). Conclusions: Particle therapy using protons or carbon ions was effective for unresectable or incompletely resected pelvic BSTS, and the 32-fraction protocol was effective and relatively less toxic. Nevertheless, a longer follow-up period is needed to confirm these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of washing solvents in defining the magnetic performance of Sm 2 Fe 17 N 3 obtained by reduction diffusion

Calciothermic reduction-diffusion (RD) is one of the leading synthesis methods for Sm 2 Fe 17 N 3 (SmFeN), but sintering of such RD-derived powders is hampered by oxidation and CaO byproducts. Here, we systematically evaluate how post-synthesis washing solvents govern powder chemistry and magnetic performance. RD-synthesized SmFeN powder was washed with several aqueous and non-aqueous solvents using identical washing protocols. This was followed by an assessment of both the as-washed powder as well as after annealing at 425 °C. Phase content was quantified by synchrotron PXRD and Rietveld refinement and SEM/EDS. The oxygen content of the powders was determined via inert gas fusion and the magnetization by DC magnetometry. While all aqueous-based solutions were able to remove CaO, the non-aqueous solutions were only effective with extended washing times. Prior to annealing, the crystalline phases and magnetic properties of the as-washed powders were largely the same regardless of washing solvent. However, differences emerge after annealing, where water-based washing markedly lowers the coercivity (H c ~3.8-4.3 kOe). In contrast, non-aqueous NH 4 Cl-methanol washing protocols were more effective in preserving coercivity (H c ~4.9-5.9 kOe). We attribute this to lower oxygen content in the non-aqueous samples (~9,400 ppm v ~6,400 ppm, respectively) which in turn reduced the formation of α-Fe during annealing. These results highlight the importance of solvent choice in washing RD-synthesized SmFeN and demonstrate that non-aqueous protocols, which better limit oxidation, outperform aqueous solvents despite the need for longer washing times.

36 MATERIALS SCIENCE↗

Balancing formation time and electrochemical performance of high energy lithium-ion batteries

Most lithium-ion batteries still rely on intercalation-type graphite materials for anodes, and the formation process for them typically takes several days or even more to provide a stable solid electrolyte interphase (SEI). The slow formation step results in lower LIB production rates, requires a large number of battery cyclers, and constitutes the second highest cost during battery manufacturing. In an effort to decrease the high manufacturing cost associated with long formation times, here we studied five different formation protocols in nickel-rich LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811)/graphite cells where the total formation time varied from 10 to 86 h. Electrochemical characterization and post mortem analysis show that very long formation time do not necessarily improve long-term performance while very short formation protocols result in lithium plating and poorer electrochemical performance. Finally, we find the optimum formation cycling protocol is intermediate in length to minimize impedance growth, improve capacity retention, and avoid lithium plating.

25 ENERGY STORAGE↗

Direct observations of crystal defects in polycrystalline diamond

Highlights: • Electron channeling contrast imaging of crystal defects in polycrystalline diamond • Introducing acid etching as a novel protocol for diamond surface preparation • Characterization of {111} twins, {111} stacking faults and {111} helical dislocations in diamond using ECCI and EBSD - Abstract: Crystal defects are abundant in synthetic diamond produced by chemical vapor deposition (CVD). We present the first images of crystal defects in a bulk polycrystalline CVD diamond sample using general electron channeling contrast imaging (ECCI) in a field emission scanning electron microscope (FE-SEM). For enhancement of channeling contrast of this material, we introduce a novel protocol for diamond surface preparation that involves acid etching. Using this protocol, we imaged three types of crystal defects including twins, stacking faults and dislocations. Each defect was identified based on its appearance in electron channeling contrast (ECC) micrographs. We analyzed grains containing twins and dislocations using electron backscatter diffraction (EBSD) crystal orientation mapping. We found a large population of grains that contained Σ3 type twins on {111} planes with a 60°<111> angle–axis pair of misorientation for twin boundaries. In addition, we identified {111} stacking faults and {111} helical dislocations. These observations are in agreement with reports of crystal defects in CVD diamond thin foils studied by a transmission electron microscope (TEM).

36 MATERIALS SCIENCE↗

Single crystal growth and variation of thermodynamic and magnetic properties of Pr1−xLaxAlO3 (x = 0, 0.8)

Highlights: • The perovskite Pr{sub (1-x)}La{sub (x)}AlO{sub 3} was grown by two different protocols to control the P{sup 4+} concentration. • Low temperature magnetic properties in bulk single crystals are sensitive to annealing protocols. • Post growth annealing in a reducing atmosphere leads to closest Pr{sub 0.2}La{sub 0.8}AlO{sub 3} stoichiometry. • A possible new magnetic transition for single crystal PrAlO{sub 3} is observed at 6 K. - Abstract: Two approaches to using optical floating zone (OFZ) technique for single crystal growth of the perovskite Pr{sub 1−x}La{sub x}AlO{sub 3} are discussed, along with the influence on the physical properties of the resulting single crystals due to oxidizing and reducing post anneals. In method one (M1) we used pre-reduced Pr{sub 2}O{sub 3} powder starting material, while in the other method, M2, we employed an argon 5% hydrogen reducing environment during the floating zone single crystal growth. Magnetic susceptibility of the low temperature monoclinic phase of Pr{sub 0.2}La{sub 0.8}AlO{sub 3} is shown to be sensitive to the precise annealing protocol followed. For the post-growth reduced single crystal the magnetic susceptibility is flat across the R-3c to C2/m structural transition, whereas the oxidized and as-grown samples display a sharp upturn and downturn, respectively. We attribute the low temperature susceptibility differences to relative proportions of Pr{sup 3+} and Pr{sup 4+}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A planning comparison of 7 irradiation options allowed in RTOG 1005 for early-stage breast cancer

This study compared the 7 treatment plan options in achieving the dose-volume criteria required by the Radiation Therapy Oncology Group (RTOG) 1005 protocol. Dosimetry plans were generated for 15 representative patients with early-stage breast cancer (ESBC) based on the protocol-required dose-volume criteria for each of the following 7 treatment options: 3D conformal radiotherapy (3DCRT), whole-breast irradiation (WBI) plus 3DCRT lumpectomy boost, 3DCRT WBI plus electron boost, 3DCRT WBI plus intensity-modulated radiation therapy (IMRT) boost, IMRT WBI plus 3DCRT boost, IMRT WBI plus electron boost, IMRT WBI plus IMRT boost, and simultaneous integrated boost (SIB) with IMRT. A variety of dose-volume parameters, including target dose conformity and uniformity and normal tissue sparing, were compared for these plans. For the patients studied, all plans met the required acceptable dose-volume criteria, with most of them meeting the ideal criteria. When averaged over patients, most dose-volume goals for all plan options can be achieved with a positive gap of at least a few tenths of standard deviations. The plans for all 7 options are generally comparable. The dose-volume goals required by the protocol can in general be easily achieved. IMRT WBI provides better whole-breast dose uniformity than 3DCRT WBI does, but it causes no significant difference for the dose conformity. All plan options are comparable for lumpectomy dose uniformity and conformity. Patient anatomy is always an important factor when whole-breast dose uniformity and conformity and lumpectomy dose conformity are considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT)

An efficient and simple class solution is proposed for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT) planning using the Volumetric Arc Therapy (VMAT) delivery technique following the NRG Oncology protocol NRG-CC001 treatment planning guidelines. The whole-brain planning target volume (PTV) was subdivided into subplanning volumes that lie in plane and out of plane with the hippocampal-avoidance volume. To further improve VMAT treatment plans, a partial-field dual-arc technique was developed. Both the arcs were allowed to overlap on the in-plane subtarget volume, and in addition, one arc covered the superior out-of-plane sub-PTV, while the other covered the inferior out-of-plane subtarget volume. For all plans (n = 20), the NRG-CC001 protocol dose-volume criteria were met. Mean values of volumes for the hippocampus and the hippocampal-avoidance volume were 4.1 cm{sup 3} ± 1.0 cm{sup 3} and 28.52 cm{sup 3} ± 3.22 cm{sup 3}, respectively. For the PTV, the average values of D{sub 2%} and D{sub 98%} were 36.1 Gy ± 0.8 Gy and 26.2 Gy ± 0.6 Gy, respectively. The hippocampus D{sub 100%} mean value was 8.5 Gy ± 0.2 Gy and the maximum dose was 15.7 Gy ± 0.3 Gy. The corresponding plan quality indices were 0.30 ± 0.01 (homogeneity index), 0.94 ± 0.01 (target conformality), and 0.75 ± 0.02 (confirmation number). The median total monitor unit (MU) per fraction was 806 MU (interquartile range [IQR]: 792 to 818 MU) and the average beam total delivery time was 121.2 seconds (IQR: 120.6 to 121.35 seconds). All plans passed the gamma evaluation using the 5-mm, 4% criteria, with γ > 1 of not more than 9.1% data points for all fields. An efficient and simple planning class solution for HA-WBRT using VMAT has been developed that allows all protocol constraints of NRG-CC001 to be met.

61 RADIATION PROTECTION AND DOSIMETRY↗

A systematic analytical framework for multi-source municipal solid waste characterization for energy recovery

Advancing municipal solid waste (MSW) management from disposal-oriented practices toward circular, value-driven systems requires standardized methodologies capable of identifying material composition and resource recoverable potential at the point of generation. Despite extensive research, MSW characterization remains fragmented due to inconsistences in sampling methodologies, waste sorting categories, and temporal coverage across previous studies which limit cross-site comparability, reproducibility, and constrain the reliable evaluation of potential resource recovery pathways. This lack of consistency has hindered the development of a unified framework for MSW characterization and resource assessment. This study introduces a standardized, field-validated protocol for MSW sampling and composition analysis that ensures consistent, traceable data across diverse waste sources. The protocol integrates randomized spatial sampling, systematic material sorting, and controlled subsampling for multi-site and multi-season field campaigns. Validation included MSW collection from residential, grocery, restaurant, and school MSW streams across five U.S. states, including Maryland, Idaho, Virginia, Ohio, and Mississippi, to demonstrate the protocol’s ability to identify source-based composition patterns relevant to resource recovery applications. Grocery and restaurant streams were dominated by food waste and high-moisture organics, while school waste contained higher paper content and residential waste showed greater heterogeneity. Aggregation into energy-relevant fractions highlighted practical recovery pathways via anaerobic digestion or gasification, supporting data-driven planning, policy, and circular economy strategies for sustainable waste management across waste sources.

09 BIOMASS FUELS↗

A progressive electrochemical sensor for food quality control: Reliable determination of theobromine in chocolate products using a miniaturized boron-doped diamond electrode

In the present paper, a miniaturized boron-doped diamond electrode (BDDE) is proposed as a progressive electrochemical sensor for simple, fast and reliable quantification of dimethylxanthine alkaloid, theobromine (TB). Using cyclic voltammetry, the studied xanthine provided one well-shaped, irreversible and diffusion-controlled oxidation peak at relatively high potentials (+1.2 V vs. Ag/AgCl/3 M KCl reference electrode) in the presence of 0.1 M H2SO4. After selection of suitable experimental conditions, the linear calibration curves for TB were obtained in the concentration range from 0.99 up to 54.5 μM with the sensitivity of 0.07 μA/μM providing both differential pulse (DPV) and square-wave voltammetric (SWV) techniques, respectively. The elaborated voltammetric protocol yielded low detection limits of 0.42 and 0.51 μM accompanied by adequate intra-day repeatability (relative standard deviation of 2.5 and 1.7%) using DPV and SWV procedure, respectively. The interference study revealed the reasonable selectivity when taking the target food samples into account. The practical applicability of the voltammetric protocol using a miniaturized BDDE was verified in the analysis of six commercially available brands of chocolate products with the determined mass percentages of TB ranging from 0.75 to 2.24% and from 0.69 to 2.15% using DPV and SWV procedure, respectively. The obtained results were also in a good agreement with those achieved by reference titration method with potentiometric indication. The progressive electrochemical sensor based on a miniaturized BDDE has appeared to be an attractive candidate for practical applications in food quality control. Besides, the proposed voltammetric protocol presents advantages when compared to others techniques (e.g. chromatography), concerning simplicity, cost, speed of analysis, waste generation (environmentally friendly) and samples pretreatment (only dilution in electrolyte solution prior to analysis). © 2018 Elsevier B.V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel data analysis method for obtaining better performance from a complex 3D-printed collimator

Additively manufactured scattered beam collimators are increasingly being employed to boost the sample to cell peak signal ratio in high pressure neutron diffraction studies because of manufacturing versatility and performance improvements. We study how the measured diffraction pattern is affected by the presence of a collimator downstream of the sample, and develop a novel protocol that provides more effective background rejection. This protocol takes into account critical performance-determinants that were identified in this study, namely: (i) effectively identifying the collimator pattern on the detector; (ii) understanding the dependence of this pattern on sample and cell composition; and (iii) accurately identifying and differentiating the different regions of the pattern on the detector based on the dependency of the cell or sample and finally (iv) resolving the intensities at regions of the detector where neutrons scattered from the sample are preferentially represented, in order to boost the sample to cell peak signal ratio. Application of this novel analysis protocol is shown to increase the collimator performance over the traditional method.

3D printing↗

Capturing the Page curve and entanglement dynamics of black holes in quantum computers

Quantum computers are emerging technologies expected to become important tools for exploring various aspects of fundamental physics in the future. Therefore, we pose the question of whether quantum computers can help us to study the Page curve and the black hole information dynamics, which has been a key focus in fundamental physics. In this regard, we rigorously examine the qubit transport model, a toy qubit model of black hole evaporation on IBM’s superconducting quantum computers, to shed light on this question. Specifically, we implement the quantum simulation of the scrambling dynamics in black holes using an efficient random unitary circuit. Furthermore, we employ the swap-based many-body interference protocol and the randomized measurement protocol to measure the entanglement entropy of Hawking radiation qubits in this model. Finally, by incorporating quantum error mitigation techniques into our challenging implementation of entanglement entropy measurement protocols on the IBM quantum hardware, we accurately determine the Rényi entropy in the qubit transport model, thus showcasing the utility of quantum computers for future investigations of complex quantum systems.

97 MATHEMATICS AND COMPUTING↗

Combinations of ketamine and atropine are neuroprotective and reduce neuroinflammation after a toxic status epilepticus in mice

Epileptic seizures and status epilepticus (SE) induced by the poisoning with organophosphorus nerve agents (OP), like soman, are accompanied by neuroinflammation whose role in seizure-related brain damage (SRBD) is not clear. Antagonists of the NMDA glutamate ionotropic receptors are currently among the few compounds able to arrest seizures and provide neuroprotection even during refractory status epilepticus (RSE). Racemic ketamine (KET), in combination with atropine sulfate (AS), was previously shown to counteract seizures and SRBD in soman-poisoned guinea-pigs. In a mouse model of severe soman-induced SE, we assessed the potentials of KET/AS combinations as a treatment for SE/RSE-induced SRBD and neuroinflammation. When starting 30 min after soman challenge, a protocol involving six injections of a sub-anesthetic dose of KET (25 mg/kg) was evaluated on body weight loss, brain damage, and neuroinflammation whereas during RSE, anesthetic protocols were considered (KET 100 mg/kg). After confirming that during RSE, KET injection was to be repeated despite some iatrogenic deaths, we used these proof-of-concept protocols to study the changes in mRNA and related protein contents of some inflammatory cytokines, chemokines and adhesion molecules in cortex and hippocampus 48 h post-challenge. In both cases, the KET/AS combinations showed important neuroprotective effects, suppressed neutrophil granulocyte infiltration and partially suppressed glial activation. KET/AS could also reduce the increase in mRNA and related pro-inflammatory proteins provoked by the poisoning. In conclusion, the present study confirms that KET/AS treatment has a strong potential for SE/RSE management following OP poisoning. The mechanisms involved in the reduction of central neuroinflammation remain to be studied. -- Highlights: ► During soman-induced status epilepticus, ketamine-atropine limit brain damage. ► Molecular neuroinflammatory response is strongly decreased. ► Glial activation is not fully suppressed.

60 APPLIED LIFE SCIENCES↗

Model-based analysis of thromboxane B{sub 2} and prostaglandin E{sub 2} as biomarkers in the safety evaluation of naproxen

The assessment of safety in traditional toxicology protocols relies on evidence arising from observed adverse events (AEs) in animals and on establishing their correlation with different measures of drug exposure (e.g., C{sub max} and AUC). Such correlations, however, ignore the role of biomarkers, which can provide further insight into the underlying pharmacological mechanisms. Here we use naproxen as a paradigm drug to explore the feasibility of a biomarker-guided approach for the prediction of AEs in humans. A standard toxicology protocol was set up for the evaluation of effects of naproxen in rat, in which four doses were tested (7.5, 15, 40 and 80 mg/kg). In addition to sparse blood sampling for the assessment of exposure, thromboxane B{sub 2} and prostaglandin E{sub 2} were also collected in satellite groups. Nonlinear mixed effects modelling was used to evaluate the predictive performance of the approach. A one-compartmental model with first order absorption was found to best describe the pharmacokinetics of naproxen. A nonlinear relationship between dose and bioavailability was observed which leads to a less than proportional increase in naproxen concentrations with increasing doses. The pharmacodynamics of TXB{sub 2} and PGE{sub 2} was described by direct inhibition models with maximum pharmacological effects achieved at doses > 7.5 mg/kg. The predicted PKPD relationship in humans was within 10-fold of the values previously published. Moreover, our results indicate that biomarkers can be used to assess interspecies differences in PKPD and extrapolated data from animals to humans. Biomarker sampling should be used systematically in general toxicity studies. - Highlights: • Prediction of a drug's safety profile from preclinical protocols remains challenging. • Pharmacokinetic measures of safe exposure (e.g., AUC) ignore the role of biomarkers. • PKPD relationships enable the evaluation of adverse events in a mechanistic manner. • Major differences exist between rats and humans in the effects of naproxen on TXB{sub 2}. • A biomarker-guided approach may facilitate the prediction of adverse events in humans.

60 APPLIED LIFE SCIENCES↗

Subcellular localization of proteins in the anaerobic sulfate reducer Desulfovibrio vulgaris via SNAP-tag labeling and photoconversion

Systems Biology studies the temporal and spatial 3D distribution of macromolecular complexes with the aim that such knowledge will allow more accurate modeling of biological function and will allow mathematical prediction of cellular behavior. However, in order to accomplish accurate modeling precise knowledge of spatial 3D organization and distribution inside cells is necessary. And while a number of macromolecular complexes may be identified by its 3D structure and molecular characteristics alone, the overwhelming number of proteins will need to be localized using a reporter tag. GFP and its derivatives (XFPs) have been traditionally employed for subcelllar localization using photoconversion approaches, but this approach cannot be taken for obligate anaerobic bacteria, where the intolerance towards oxygen prevents XFP approaches. As part of the GTL-funded PCAP project (now ENIGMA) genetic tools have been developed for the anaerobe sulfate reducer Desulfovibrio vulgaris that allow the high-throughput generation of tagged-protein mutant strains, with a focus on the commercially available SNAP-tag cell system (New England Biolabs, Ipswich, MA), which is based on a modified O6-alkylguanine-DNA alkyltransferase (AGT) tag, that has a dead-end reaction with a modified O6-benzylguanine (BG) derivative and has been shown to function under anaerobic conditions. After initial challenges with respect to variability, robustness and specificity of the labeling signal we have optimized the labeling. Over the last year, as a result of the optimized labeling protocol, we now obtain robust labeling of 20 out of 31 SNAP strains. Labeling for 13 strains were confirmed at least five times. We have also successfully performed photoconversion on 5 of these 13 strains, with distinct labeling patterns for different strains. For example, DsrC robustly localizes to the periplasmic portion of the inner membrane, where as a DNA-binding protein localizes to the center of the cell, where the chromosome is located. Two other proteins - Thiosulfate reductase and ATP binding protein were found to be cytoplasmically distributed, whereas a molybdenum transporter was found to locate to the cell periphery. We judge labeling outcome by (1) SDS gel electrophoresis, followed by direct fluorescence imaging of the gel to address specificity of labeling/confirm expected molecular weight, and subsequent Coomassie analysis to ensure comparable protein levels (2) fluorescence intensity of culture by plate reader for statistical sampling (after adjustment for respective cell numbers) and (3) fluorescence microscopy for addressing cell-to-cell signal variation and potential localization patterns. All three assays were usually found to be consistent with one another. While we have been able to improve the efficacy of photoconversion by drastically reducing (eliminating) non-specific binding with our altered labeling protocol, we are currently working on reducing non-specific photoconversion reaction arising occasionally in non-labeled cells. In addition, we have confirmed the presence of SNAP tagged constructs in three recently cloned E.coli strains under promotor control, and are in the process of utilizing them for evaluating the sensitivity of the photoconversion protocol. Fluorescent Activated Cell Sorting was successfully applied to labeled E.coli cells containing SNAP tagged AtpA protein. Different batches of sorted cells, representing low and high labeling intensity, were re-grown and re-labeled and displayed a labeling efficiency similar to the starter culture, supporting the notion that cell-to-cell differences in labeling reflect difference in protein expression, rather then genetic differences.

54 ENVIRONMENTAL SCIENCES↗