Search NASA⌕ Search

SEARCH · Search NASA

Results for “setting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

SU-E-J-172: Bio-Physical Effects of Patients Set-Up Errors According to Whole Breast Irradiation Techniques

Purpose: The dose-related effects of patient setup errors on biophysical indices were evaluated for conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques. Methods: The treatment plans for 10 patients receiving whole left breast irradiation were retrospectively selected. Radiobiological and physical effects caused by dose variations were evaluated by shifting the isocenters and gantry angles of the treatment plans. Dose-volume histograms of the planning target volume (PTV), heart, and lungs were generated, and conformity index (CI), homogeneity index (HI), tumor control probability (TCP), and normal tissue complication probability (NTCP) were determined. Results: For “isocenter shift plan” with posterior direction, the D95 of the PTV decreased by approximately 15% and the TCP of the PTV decreased by approximately 50% for the FIF technique and by 40% for the CW; however, the NTCPs of the lungs and heart increased by about 13% and 1%, respectively, for both techniques. Increasing the gantry angle decreased the TCPs of the PTV by 24.4% (CW) and by 34% (FIF). The NTCPs for the two techniques differed by only 3%. In case of CW, the CIs and HIs were much higher than that of the FIF in all cases. It had a significant difference between two techniques (p<0.01). According to our results, however, the FIF had more sensitive response by set up errors rather than CW in bio-physical aspects. Conclusions: The radiobiological-based analysis can detect significant dosimetric errors then, can provide a practical patient quality assurance method to guide the radiobiological and physical effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-345: Effect of DLG and MLC Transmission Value Set in the Treatment Planning System (TPS) On Dosimetric Accuracy of True Beam Hypofractionated SRT/SBRT and 2Gy/fx Prostate Rapid Arc Plans

Purpose: Due to limited commissioning time, we previously only released our True beam non-FFF mode for prostate treatment. Clinical demand now pushes us to release the non-FFF mode for SRT/SBRT treatment. When re-planning on True beam previously treated SRT/SBRT cases on iX machine we found the patient specific QA pass rate was worse than iX’s, though the 2Gy/fx prostate Result had been as good. We hypothesize that in TPS the True beam DLG and MLC transmission values, of those measured during commissioning could not yet provide accurate SRS/SBRT dosimetry. Hence this work is to investigate how the TPS DLG and transmission value affects Rapid Arc plans’ dosimetric accuracy. Methods: We increased DLG and transmission value of True beam in TPS such that their percentage differences against the measured matched those of iX’s. We re-calculated 2 SRT, 1 SBRT and 2 prostate plans, performed patient specific QA on these new plans and compared the results to the previous. Results: With DLG and transmission value set respectively 40 and 8% higher than the measured, the patient specific QA pass rate (at 3%/3mm) improved from 95.0 to 97.6% vs previous iX’s 97.8% in the case of SRT. In the case of SBRT, the pass rate improved from 75.2 to 93.9% vs previous iX’s 92.5%. In the case of prostate, the pass rate improved from 99.3 to 100%. The maximum dose difference in plans before and after adjusting DLG and transmission was approximately 1% of the prescription dose among all plans. Conclusion: The impact of adjusting DLG and transmission value on dosimetry might be the same among all Rapid Arc plans regardless hypofractionated or not. The large variation observed in patient specific QA pass rate might be due to the data analysis method in the QA software being more sensitive to hypofractionated plans.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

WE-F-BRB-02: Setting the Stage for Incorporation of Toxicity Measures in Treatment Plan Assessments

Advancements in informatics in radiotherapy are opening up opportunities to improve our ability to assess treatment plans. Models on individualizing patient dose constraints from prior patient data and shape relationships have been extensively researched and are now making their way into commercial products. New developments in knowledge based treatment planning involve understanding the impact of the radiation dosimetry on the patient. Akin to radiobiology models that have driven intensity modulated radiotherapy optimization, toxicity and outcome predictions based on treatment plans and prior patient experiences may be the next step in knowledge based planning. In order to realize these predictions, it is necessary to understand how the clinical information can be captured, structured and organized with ontologies and databases designed for recall. Large databases containing radiation dosimetry and outcomes present the opportunity to evaluate treatment plans against predictions of toxicity and disease response. Such evaluations can be based on dose volume histogram or even the full 3-dimensional dose distribution and its relation to the critical anatomy. This session will provide an understanding of ontologies and standard terminologies used to capture clinical knowledge into structured databases; How data can be organized and accessed to utilize the knowledge in planning; and examples of research and clinical efforts to incorporate that clinical knowledge into planning for improved care for our patients. Learning Objectives: Understand the role of standard terminologies, ontologies and data organization in oncology Understand methods to capture clinical toxicity and outcomes in a clinical setting Understand opportunities to learn from clinical data and its application to treatment planning Todd McNutt receives funding from Philips, Elekta and Toshiba for some of the work presented.

60 APPLIED LIFE SCIENCES↗

SU-F-P-33: Combining Research and Professional Practice in the Clinical Setting: A Medical Physicist Personal Experience

Purpose: To initiate a discussion on the current and evolving role of Medical Physicists based on author’s professional and research experience in patient safety and quality control. Methods: Several professionals of the departments of Medical Physics and Radiation Oncology, chiefly devoted to clinical tasks, began a research program on patient safety and quality control in a framework provided by the implementation of intraoperative radiotherapy (IORT). We performed studies on virtual simulation for IORT, in vivo dosimetry, failure mode and effect analysis (FMEA), statistical process control (SPC), and receiver operating characteristics of dosimetric equipment. This was done with the support of our research foundation and different grants while continuing with our departmental clinical routine involving about 1600 annual treatments with two linacs and different brachytherapy techniques. Results: We published 5 papers in international journals in the last two years. This author conducted a doctoral research which resulted in a dissertation in 2015. The extra time spent after treatments was essential to succeed. Funding and support achieved via our foundation played a crucial role; but this would have not been possible without punctual external mentoring and partnership. FMEA conclusions were able to be implemented only with staff commitment; however, conclusions concerning equipment cannot be easily communicated to manufacturers. These tasks required extra training in the appropriated methods. Conclusion: Research needed the support of a dedicated foundation, which would have been very difficult to obtain with the sole participation of our departments. FMEA and SPC results may need engagement of staff and manufacturers, respectively, hard to achieve without strong recommendations or even a regulatory framework. All these fields need evolution of Medical Physicists’ roles and additional training. Devotion to both clinical tasks and research could be unfeasible for Medical Physicists in the clinical setting without the appropriate rearrangement of their schedules and tasks. Supported by grants IPT-300000-2010-3 and PI11/01659. ERDF funds and Spanish Government.

60 APPLIED LIFE SCIENCES↗

SU-F-J-32: Do We Need KV Imaging During CBCT Based Patient Set-Up for Lung Radiation Therapy?

Purpose: To evaluate the role of 2D kilovoltage (kV) imaging to complement cone beam CT (CBCT) imaging in a shift threshold based image guided radiation therapy (IGRT) strategy for conventional lung radiotherapy. Methods: A retrospective study was conducted by analyzing IGRT couch shift trends for 15 patients that received lung radiation therapy to evaluate the benefit of performing orthogonal kV imaging prior to CBCT imaging. Herein, a shift threshold based IGRT protocol was applied, which would mandate additional CBCT verification if the applied patient shifts exceeded 3 mm to avoid intraobserver variability in CBCT registration and to confirm table shifts. For each patient, two IGRT strategies: kV + CBCT and CBCT alone, were compared and the recorded patient shifts were categorized into whether additional CBCT acquisition would have been mandated or not. The effectiveness of either strategy was gauged by the likelihood of needing additional CBCT imaging for accurate patient set-up. Results: The use of CBCT alone was 6 times more likely to require an additional CBCT than KV+CBCT, for a 3 mm shift threshold (88% vs 14%). The likelihood of additional CBCT verification generally increased with lower shift thresholds, and was significantly lower when kV+CBCT was used (7% with 5 mm shift threshold, 36% with 2 mm threshold), than with CBCT alone (61% with 5 mm shift threshold, 97% with 2 mm threshold). With CBCT alone, treatment time increased by 2.2 min and dose increased by 1.9 cGy per fraction on average due to additional CBCT with a 3mm shift threshold. Conclusion: The benefit of kV imaging to screen for gross misalignments led to more accurate CBCT based patient localization compared with using CBCT alone. The subsequently reduced need for additional CBCT verification will minimize treatment time and result in less overall patient imaging dose.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-15: The Roucoulette: A Set of Quality Control Tests for Dynamic Trajectory (4Pi) Treatment Delivery Techniques

Purpose: To present and validate a set of quality control tests for trajectory treatment delivery using synchronized dynamic couch (translation and rotation), MLC and collimator motion. Methods: The quality control tests are based on the Picket fence test, which consist of 5 narrow band 2mm width spaced at 2.5cm intervals, and adds progressively synchronized dynamic motions. The tests were exposed on GafChromic EBT3 films. The first test is a regular (no motion and MLC static while beam is on) Picket Fence test used as baseline. The second test includes simultaneous collimator and couch rotation, each stripe corresponding to a different rotation speed. Errors in these tests were introduced (0.5 degree and 1 degree error in rotation synchronization) to assess the error sensitivity of this test. The second test is similar to the regular Picket Fence but now including dynamic MLC motion and couch translation (including acceleration during delivery) while the beam is on. Finally in the third test, which is a combination of the first and second test, the Picket Fence pattern is delivered using synchronized collimator and couch rotation and synchronized dynamic MLC and couch translation including acceleration. Films were analyzed with FilmQA Pro. Results: The distance between the peaks in the dose profile where measured (18.5cm away from the isocentre in the inplane direction where non synchronized rotation would have the largest effect) and compared to the regular Picket Fence tests. For well synchronized motions distances between peaks where between 24.9–25.4 mm identical to the regular Picket Fence test. This range increased to 24.4–26.4mm and 23.4–26.4mm for 0.5 degree and 1 degree error respectively. The amplitude also decreased up to 15% when errors are introduced. Conclusion: We demonstrated that the Roucoulette tests can be used as a quality control tests for trajectory treatment delivery using synchronized dynamic motion.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-01: A Global Level Set Based Formulation for Volumetric Modulated Arc Therapy

Purpose: The current clinical Volumetric Modulated Arc Therapy (VMAT) optimization is formulated as a non-convex problem and various greedy heuristics have been employed for an empirical solution, jeopardizing plan consistency and quality. We introduce a novel global direct aperture optimization method for VMAT to overcome these limitations. Methods: The global VMAT (gVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term and an anisotropic total variation term. A level set function was used to describe the aperture shapes and adjacent aperture shapes were penalized to control MLC motion range. An alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc gVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme (GBM), lung (LNG), and 2 head and neck cases—one with 3 PTVs (H&N3PTV) and one with 4 PTVs (H&N4PTV). The plans were compared against the clinical VMAT (cVMAT) plans utilizing two overlapping coplanar arcs. Results: The optimization of the gVMAT plans had converged within 600 iterations. gVMAT reduced the average max and mean OAR dose by 6.59% and 7.45% of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N3PTV case. PTV coverages (D95, D98, D99) were within 0.25% of the prescription dose. By globally considering all beams, the gVMAT optimizer allowed some beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel VMAT approach allows for the search of an optimal plan in the global solution space and generates deliverable apertures directly. The single arc VMAT approach fully utilizes the digital linacs’ capability in dose rate and gantry rotation speed modulation. Varian Medical Systems, NIH grant R01CA188300, NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Complete enzyme set for chlorophyll biosynthesis in Escherichia coli

Chlorophylls are essential cofactors for photosynthesis, which sustains global food chains and oxygen production. Billions of tons of chlorophylls are synthesized annually, yet full understanding of chlorophyll biosynthesis has been hindered by the lack of characterization of the Mg–protoporphyrin IX monomethyl ester oxidative cyclase step, which confers the distinctive green color of these pigments. We demonstrate cyclase activity using heterologously expressed enzyme. Next, we assemble a genetic module that encodes the complete chlorophyll biosynthetic pathway and show that it functions in Escherichia coli . Expression of 12 genes converts endogenous protoporphyrin IX into chlorophyll a, turning E. coli cells green. Our results delineate a minimum set of enzymes required to make chlorophyll and establish a platform for engineering photosynthesis in a heterotrophic model organism.

59 BASIC BIOLOGICAL SCIENCES↗

Electron ptychography achieves atomic-resolution limits set by lattice vibrations

Transmission electron microscopes use electrons with wavelengths of a few picometers, potentially capable of imaging individual atoms in solids at a resolution ultimately set by the intrinsic size of an atom. However, owing to lens aberrations and multiple scattering of electrons in the sample, the image resolution is reduced by a factor of 3 to 10. By inversely solving the multiple scattering problem and overcoming the electron-probe aberrations using electron ptychography, we demonstrate an instrumental blurring of less than 20 picometers and a linear phase response in thick samples. The measured widths of atomic columns are limited by thermal fluctuations of the atoms. As a result, our method is also capable of locating embedded atomic dopant atoms in all three dimensions with subnanometer precision from only a single projection measurement.

42 ENGINEERING↗

Quantum optimization of maximum independent set using Rydberg atom arrays

Realizing quantum speedup for practically relevant, computationally hard problems is a central challenge in quantum information science. Using Rydberg atom arrays with up to 289 qubits in two spatial dimensions, we experimentally investigate quantum algorithms for solving the maximum independent set problem. We use a hardware-efficient encoding associated with Rydberg blockade, realize closed-loop optimization to test several variational algorithms, and subsequently apply them to systematically explore a class of graphs with programmable connectivity. We find that the problem hardness is controlled by the solution degeneracy and number of local minima, and we experimentally benchmark the quantum algorithm’s performance against classical simulated annealing. On the hardest graphs, we observe a superlinear quantum speedup in finding exact solutions in the deep circuit regime and analyze its origins.

Science & Technology - Other Topics↗

RB-TnSeq barcode abundance data sets for Novosphingobium aromaticivorans grown on the β-5-linked aromatic dimer dehydrodiconiferyl alcohol

ABSTRACT A randomly barcoded transposon insertion sequencing (RB-TnSeq) library of Novosphingobium aromaticivorans DSM12444 was grown in media containing either glucose or the β-5-linked aromatic dimer dehydrodiconiferyl alcohol (DC-A) as the sole carbon source. The cultures were grown to saturation and then sequenced, yielding the barcode abundance data sets presented here.

Metz, Fletcher↗

Irreducibility of the set of field operators in NC QFT

Irreducibility of the set of quantum field operators has been proved in noncommutative quantum field theory in the general case when time does not commute with spatial variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complete set of deuteron analyzing powers for dp elastic scattering at intermediate energies

With the aim of clarifying roles of the 3NFs in nuclei experimental programs with polarized deuterons beams at intermediate energies are in progress at RIKEN RI Beam Factory. As the first step, we have measured a complete set of deuteron analyzing powers (iT{sub 11}, T{sub 20}, T{sub 21}, T{sub 22}) in deuteron-proton elastic scattering at 250 and 294 MeV/nucleon. The obtained data are compared with the Faddeev calculations based on the modern nucleon-nucleon forces together with the Tucson-Melbourne’99, and UrbanaIX three nucleon forces.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the minimal set of plasma parameters to determine the dispersion law of electron whistler waves

The minimal sufficient set of plasma parameters is presented to describe the dispersion properties of electron whistler waves (helicons) in a wide frequency range above the ion cutoff frequency, provided that the wave frequency is significantly lower than the electron plasma frequency. When the gyrofrequency of the lightest ions is much higher than those of heavier ions, it is sufficient to know the relative content of the lightest ions, the highest ion cutoff frequency, the lower hybrid resonance frequency, and the electron gyro- and plasma frequencies. In this case, the frequency of electron whistler waves is determined by the upper root of the biquadratic equation derived, whereas the lower root corresponds to a resonant mode with its refractive index increasing when the frequency tends toward the highest ion gyrofrequency from below. The developed approach is also efficient in plasmas containing a substantial amount of negative ions and/or heavy dust particulates. The accuracy of the approximate solution of the total cold plasma dispersion relation is illustrated graphically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How Good is Good Enough?: Quantifying the Effects of Training Set Quality

There is a general consensus in the neural network community that noise in training data has a negative impact on model output; however, efforts to quantify the impact of varying levels have been limited, particularly for semantic segmentation tasks. This is a question of particular importance for remote sensing applications where the cost of producing a large training set can lead to reliance on publicly available data with varying degrees of noise. This work explores the effects of different degrees and types of training label noise on a pre-trained building extraction deep learner. Quantitative and qualitative evaluations of these effects can help inform decisions about trade-offs between the cost of producing training data and the quality of model outputs. We found that, relative to the base model, models trained with small amounts of noise showed little change in precision but achieved considerable increases in recall. Conversely, as noise levels increased, both precision and recall decreased. Precision and recall both lagged behind a model trained with pristine data. These exploratory results indicate the importance of quality control for training and, more broadly, that the relationship between degrees and types of training data noise and model performance is more complex than trade-offs between precision and recall.

Swan, Benjamin↗

D2U: Data Driven User Emulation for the Enhancement of Cyber Testing, Training, and Data Set Generation

Whether testing intrusion detection systems, conducting training exercises, or creating data sets to be used by the broader cybersecurity community, realistic user behavior is a critical component of a cyber range. Existing methods either rely on network level data or replay recorded user actions to approximate real users in a network. Our work is the first to produce generative models trained on actual user data (sequences of application usage) collected on endpoints. Once trained to the user's behavioral data, these models can generate novel sequences of actions %that appear to come from the same distribution as the training data. These sequences of actions are then fed to our custom software via configuration files, which replicate those behaviors on end devices. Notably, our models are platform agnostic and could generate behavior data for any emulation software package. In this paper we present our model generation process, software architecture, and an initial evaluation of the fidelity of our models. Our software is currently deployed in a cyber range to help evaluate the efficacy of defensive cyber technologies. We suggest additional ways that the cyber community as a whole can benefit from more realistic user behavior emulation. The data used to train our model, as well as sample configuration files produced by the model, are available at [redacted].

Oesch, T↗