Search NASA⌕ Search

SEARCH · Search NASA

Results for “software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

An Integrated Software Package to Enable Predictive Simulation Capabilities

The power grid is increasing in complexity due to the deployment of smart grid technologies. Such technologies vastly increase the size and complexity of power grid systems for simulation and modeling. This increasing complexity necessitates not only the use of high-performance-computing (HPC) techniques, but a smooth, well-integrated interplay between HPC applications. This paper presents a new integrated software package that integrates HPC applications and a web-based visualization tool based on a middleware framework. This framework can support the data communication between different applications. Case studies with a large power system demonstrate the predictive capability brought by the integrated software package, as well as the better situational awareness provided by the web-based visualization tool in a live mode. Test results validate the effectiveness and usability of the integrated software package.

Chen, Yousu↗

An Extensible Software and Communication Platform for Distributed Energy Resource Management

This paper introduces a novel Distributed Extensible Grid Control (DEGC) software and communication platform to facilitate the control of distributed energy resources on electric grids. The DEGC software platform leverages state-of-the-art advances in secure, distributed communication and decentralized authorization and authentication. We discuss how these advances enable the kind of robust and secure communication required for a distributed grid control platform, and show how DEGC applies these technologies to the agile development and deployment of grid software through an extensible and flexible API. Here, we describe how DEGC can implement both Volt-VAR voltage magnitude control and Phasor-Based Control as sample applications and demonstrate the DEGC platform in hardware with the demanding Phasor-Based Control test case, and provide performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software-defined quantum network switching

We present the design and implementation of a software-defined quantum networking protocol and software switch integrated with a numerical quantum channel simulator. Our protocol design leverages recent advances in the OpenFlow protocol that enable software-defined control and management of optical network traffic using side-channel metadata. We implement this design using customization of the open source vSwitch for optical network routing, and we test the implementation using a numerical simulator of the quantum channel alongside actual network traffic. Our results support the integration of quantum communication with existing optical transport methods.

Humble, Travis↗

Technical Note: Development and performance of a software tool for quality assurance of online replanning with a conventional Linac or MR-Linac

Purpose: To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR-Linac, and validating the delivery record consistency with the plan. Methods: The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data are accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose–volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR-Linac reduces the difference between the plan and calculated MUs by 10%. Conclusions: The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR-Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.

60 APPLIED LIFE SCIENCES↗

SU-F-T-493: An Investigation Into the Feasibility of Using PipsPro Software with Film for Linac QA

Purpose: To determine the feasibility of using radiochromic and radiographic film with Pipspro software for quality assurance of linear accelerators with no on-board imaging. Methods: The linear accelerator being used is a Varian Clinac 21EX. All IGRT is performed using the BrainLab ExacTrac system. Because of the lack of on board imaging, certain monthly and annual TG-142 quality assurance tests are more difficult to perform and analyze to a high degree of accuracy. Pipspro was not designed to be used with hard film, and to our knowledge its use with film had not been investigated. The film used will be GafChromic EBT3 film and Kodak EDR2 film, scanned with an Epson V700 scanner. The following routine tests will be attempted: MLC picket fence, light vs. radiation field coincidence, starshots, and MLC transmission. Results: The only tests that gave accurate and reliable results were the couch, gantry, and collimator starshots. Typical MV and kV images are acquired with a much higher level of contrast between the irradiated and non-irradiated areas when compared to film. Pipspro relies on this level of contrast to be able to automatically detect the fiducial points from its phantom devices, leaf edges for picket fence and transmission tests, and jaw edges for light vs. radiation field tests. Because of this, certain tests gave erroneous results and others were not able to be performed in the software at all, with either type of film. The number of monitor units delivered to the film, the experimental setup, and the scan settings was not able to rectify the problem. Conclusion: For linear accelerators with no on-board imaging, it is not recommended to use hard film with PipsPro to perform TG-142 quality assurance tests. Other software or methods should instead be investigated.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.

60 APPLIED LIFE SCIENCES↗

TU-AB-202-03: Prediction of PET Transfer Uncertainty by DIR Error Estimating Software, AUTODIRECT

Purpose: Deformable image registration (DIR) is a powerful tool, but DIR errors can adversely affect its clinical applications. To estimate voxel-specific DIR uncertainty, a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), has been developed and validated. This work tests the ability of this software to predict uncertainty for the transfer of standard uptake values (SUV) from positron-emission tomography (PET) with DIR. Methods: Virtual phantoms are used for this study. Each phantom has a planning computed tomography (CT) image and a diagnostic PET-CT image set. A deformation was digitally applied to the diagnostic CT to create the planning CT image and establish a known deformation between the images. One lung and three rectum patient datasets were employed to create the virtual phantoms. Both of these sites have difficult deformation scenarios associated with them, which can affect DIR accuracy (lung tissue sliding and changes in rectal filling). The virtual phantoms were created to simulate these scenarios by introducing discontinuities in the deformation field at the lung rectum border. The DIR algorithm from Plastimatch software was applied to these phantoms. The SUV mapping errors from the DIR were then compared to that predicted by AUTODIRECT. Results: The SUV error distributions closely followed the AUTODIRECT predicted error distribution for the 4 test cases. The minimum and maximum PET SUVs were produced from AUTODIRECT at 95% confidence interval before applying gradient-based SUV segmentation for each of these volumes. Notably, 93.5% of the target volume warped by the true deformation was included within the AUTODIRECT-predicted maximum SUV volume after the segmentation, while 78.9% of the target volume was within the target volume warped by Plastimatch. Conclusion: The AUTODIRECT framework is able to predict PET transfer uncertainty caused by DIR, which enables an understanding of the associated target volume uncertainty.

60 APPLIED LIFE SCIENCES↗

Software and computing for Run 3 of the ATLAS experiment at the LHC

The ATLAS experiment has developed extensive software and distributed computing systems for Run 3 of the LHC. These systems are described in detail, including software infrastructure and workflows, distributed data and workload management, database infrastructure, and validation. The use of these systems to prepare the data for physics analysis and assess its quality are described, along with the software tools used for data analysis itself. An outlook for the development of these projects towards Run 4 is also provided.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Navigating the maze: the impact of configurability in bioinformatics software

The bioinformatics software domain contains thousands of applications for automating tasks such as the pairwise alignment of DNA sequences, building and reasoning about metabolic models or simulating growth of an organism. Its end users range from sophisticated developers to those with little computational experience. In response to their needs, developers provide many options to customize the way their algorithms are tuned. Yet there is little or no automated help for the user in determining the consequences or impact of the options they choose. In this paper we describe our experience working with configurable bioinformatics tools. We find limited documentation and help for combining and selecting options along with variation in both functionality and performance. We also find previously undetected faults. We summarize our findings with a set of lessons learned, and present a roadmap for creating automated techniques to interact with bioinformatics software. We believe these will generalize to other types of scientific software.

McDevitt, Mikaela Cashman↗

The Role of Data Filtering in Open Source Software Ranking and Selection

Faced with more than 100M open source projects, a more manageable small subset is needed for most empirical investigations. More than half of the research papers in leading venues investigated filtering projects by some measure of popularity with explicit or implicit arguments that unpopular projects are not of interest, may not even represent "real" software projects, or that less popular projects are not worthy of study. However, such filtering may have enormous effects on the results of the studies if and precisely because the sought-out response or prediction is in any way related to the filtering criteria.This paper exemplifies the impact of this common practice on research outcomes, specifically how filtering of software projects on GitHub based on inherent characteristics affects the assessment of their popularity. Using a dataset of over 100,000 repositories, we used multiple regression to model the number of stars -a commonly used proxy for popularity- based on factors such as the number of commits, the duration of the project, the number of authors and the number of core developers. Our control model included the entire dataset, while a second filtered model considered only projects with ten or more authors. The results indicated that while certain characteristics of the repository consistently predict popularity, the filtering process significantly alters the relationships between these characteristics and the response. We found that the number of commits exhibited a positive correlation with popularity in the control sample but showed a negative correlation in the filtered sample. These findings highlight the potential biases introduced by data filtering and emphasize the need for careful sample selection in empirical research of mining software repositories. We recommend that empirical work should either analyze complete datasets such as World of Code, or employ stratified random sampling from a complete dataset to ensure that filtering is not biasing the results.

Malviya Thakur, Addi↗

Center for Efficient Exascale Discretizations Software Suite

The CEED Software suite is a collection of generally applicable software tools focusing on the following computational motives: PDE discretizations on unstructured meshes, high-order finite element and spectral element methods and unstructured adaptive mesh refinement. All of this software is being developed as part of CEED, a co-design Center for Efficient Exascale Discretizations, within DOE's Exascale Computing Project (ECP) program.

Kolev, Tzanio↗

Software Library for Bruker TopSpin NMR Data Files

A software library for parsing and manipulating frequency-domain data files that have been processed using the Bruker TopSpin NMR software package. In the context of NMR, the term "processed" indicates that the end-user of the Bruker TopSpin NMR software package has (a) Fourier transformed the raw, time-domain data (the Free Induction Decay) into the frequency-domain and (b) has extracted the list of NMR peaks.

Source record↗

PyOECP: A flexible open-source software for the measurement and modeling of the dielectric spectrum from the reflection coefficient

We present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on two different models, including the capacitance model and the antenna model. The software library contains dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) are only required so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, the electrode polarization, which is a common measurement artifact for interpreting the dielectric spectra, can be incorporated in the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem) is also included.

Yoon, Tae-Jun↗

components for the MuMMI software release

The Department of Energy and the National Cancer Institute have developed new software for conducting multi-scale simulations of complex systems. This software, called the Multiscale Machine-Learned Modeling Infrastructure (MuMMI), couples simulations on three spatial scales to study slow, large-scale reorganizations of biomolecular systems with the speed of continuum and coarse-grained models while revealing selected interactions at full atomic precision. In these simulations, coarse-to-fine model conversions are used to spawn relevant fine-scale simulations along chosen order parameters, and fine-to-coarse feedback is used to iteratively improve the accuracy and multi-scale consistency of coarse-scale and continuum simulations. The complete MuMMI framework will be reviewed and released as open-source software by Lawrence Livermore National Laboratory. This review covers a subset of the MuMMI components that were developed exclusively at the Los Alamos National Laboratory.

Neale, Christopher↗

Learning Planar Ising Models Software

Learning Planar Ising Models is a software package written in Matlab for learning relationships among variable in a dataset using graphical models. The software package implements a generally-applicable algorithm for learning planar Ising models from any multivariate dataset. The code provides an algorithm for learning the best planar Ising model to approximate an arbitrary collection of binary random variables (possibly from sample data). Given the set of all pairwise correlations among variables, we select a planar graph and optimal planar Ising model defined on this graph to best approximate that set of correlations. The software includes demonstrations of the algorithm in simulations and for applications on publicly available datasets. Details of the algorithm, demonstration simulations, and applications are given in Johnson, et al; 2016. Reference: Johnson, J. K., Oyen, D., Chertkov, M., and Netrapalli, P. (2016). Learning planar Ising models. Journal of Machine Learning Research.

Oyen, Diane↗

sCO2 heat exchanger control software

SAND2022-6992 O The sCO2 Heat Exchanger Control Software was written for control and operation of high temperature, high pressure supercritical CO2 systems designed for use as heat exchangers. The software was written using the basic LabVIEW package with LabVIEW modules added to it. The software controls valves and actuators, displays data from pressure transducers and thermocouples, and is able to record data at different storage rates. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Garcia Maldonado, Luis↗

MSU Disentanglement Analysis Software

This software is used to disentangle the forced-versus-unforced components of tropospheric temperature change over the satellite era (after 1979) using maps of surface temperature change as a predictor. In general, the software assembles training datasets (from pre-computed surface temperature trend maps and domain averaged tropospheric warming rates), trains statistical/machine learning (ML) algorithms, applies the trained statistical/ML model to climate model data and observations, and then saves the results. A leave-one-out approach is used in which the statistical/ML models are iteratively trained on (N- 1) climate model and then applied to the remaining climate model (and observations). Each model includes a large ensemble (i.e., >10) of model simulations. The software relies on scikit-learn ridge regression, PLS regression, and neural network algorithms.

Po-Chedley, StephenD↗

Microcontroller-based aerosol jet printer control software

This software is used with a microcontroller to control an aerosol jet printing system. It was written for a 32-bit ARM microcontroller, providing greater processing speed and complexity relative to more conventional low-cost printer controllers. The microcontroller software was written using a real-time operating system (FreeRTOS), which simplifies parallel operation of multiple functions and further customization. It supports simultaneous motion planning, pulse generation for stepper motors, reading encoder feedback, communicating with multiple mass flow controllers, controlling solid state relays, handling a software-based emergency stop, and sending data to the client PC. The program is written in C and communicates with the client PC via USB connection. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-0436 O

Secor, EthanBenjamin↗