Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Hypothesis tests on Rayleigh wave radiation pattern shapes: a theoretical assessment of idealized source screening

SUMMARY Shallow seismic sources excite Rayleigh wave ground motion with azimuthally dependent radiation patterns. We place binary hypothesis tests on theoretical models of such radiation patterns to screen cylindrically symmetric sources (like explosions) from non-symmetric sources (like non-vertical dip-slip or non-VDS faults). These models for data include sources with several unknown parameters, contaminated by Gaussian noise and embedded in a layered half-space. The generalized maximum likelihood ratio tests that we derive from these data models produce screening statistics and decision rules that depend on measured, noisy ground motion at discrete sensor locations. We explicitly quantify how the screening power of these statistics increase with the size of any dip-slip and strike-slip components of the source, relative to noise (faulting signal strength) and how they vary with network geometry. As applications of our theory, we apply these tests to (1) find optimal sensor locations that maximize the probability of screening non-circular radiation patterns and (2) invert for the largest non-VDS faulting signal that could be mistakenly attributed to an explosion with damage, at a particular attribution probability. Finally, we quantify how certain errors that are sourced by opening cracks increase screening rate errors. While such theoretical solutions are ideal and require future validation, they remain important in underground explosion monitoring scenarios because they provide fundamental physical limits on the discrimination power of tests that screen explosive from non-VDS faulting sources.

58 GEOSCIENCES↗

Towards the usage of quarry blasts as an active seismic source for subsurface characterization and imaging

SUMMARY Active or man-made seismic sources are often used to delineate subsurface geological structures via seismic imaging techniques. Although conventional controlled seismic sources have provided high-resolution subsurface images, the high cost of data acquisition necessitates improved use of cheaper alternative seismic sources for subsurface imaging, such as traffic noise, quarry blasts and earthquakes. Here, we explore the potential use of quarry blasts as an active seismic source for subsurface imaging. The goal of our study is to demonstrate the utility of quarry blasts as seismic sources for investigating subsurface structure with a field experiment in Mill Creek, southern Oklahoma. We deployed a 7455-m-long receiver line of 72 receivers (105 m spacing) extending away from a quarry, with a recording time of 28 d. We analyse similarities between blasts, wave types, origin time and excitation location of quarry blasts, which is important information for using such signal as an active source. Given a relative homogeneous geological condition in the study area, we could not observe clear reflected waves. However, the use of P- and S-wave velocities led to the delineation of a major basement damage zone in the study area, which further demonstrates the viability of quarry blasts as a useful seismic source for subsurface geological imaging.

58 GEOSCIENCES↗

Estimating an airborne dipole source using 3-D wavefield simulations and seismic receivers on the ground

Acoustic signals can couple to the ground, providing an opportunity to use seismic stations to investigate airborne sources. The study of Bishop et al. used wavefield simulations in a fluid-solid medium to quantify the role of topography on the seismic (ground) recordings of a monopole source in the air. We build upon this study by linking wavefield forward modelling with the source estimation code MTUQ, which can accommodate point forces or moment tensors in a solid medium, as well as sources in the air (or water) if they are enabled by the forward-modelling solver. We perform a series of synthetic numerical experiments to demonstrate that a dipole airborne source can be estimated using ground-based receivers, even within the presence of realistic topography. We investigate the influence of receiver coverage, topography, and assumed source location on the estimated results. The established capabilities raise the prospects for future efforts to estimate dipole sources in 3-D models that include heterogeneity in the air and the earth in addition to topography.

58 GEOSCIENCES↗

Optical properties of Peaked Spectrum radio sources

ABSTRACT In this work, we study the optical properties of compact radio sources selected from the literature in order to determine the impact of the radio-jet in their circumnuclear environment. Our sample includes 58 Compact Steep Spectrum (CSS) and GigaHertz Peaked Spectrum (GPS) and 14 Megahertz-Peaked spectrum (MPS) radio sources located at z ≤ 1. The radio luminosity (LR) of the sample varies between Log LR ∼ 23.2 and 27.7 W Hz−1. We obtained optical spectra for all sources from SDSS-DR12 and performed a stellar population synthesis using the starlight code. We derived stellar masses (M⋆), ages 〈t⋆〉, star formation rates (SFR), metallicities 〈Z⋆〉 and internal reddening AV for all young AGNs of our sample. A visual inspection of the SDSS images was made to assign a morphological class for each source. Our results indicate that the sample is dominated by intermediate to old stellar populations and there is no strong correlation between optical and radio properties of these sources. Also, we found that young AGNs can be hosted by elliptical, spiral and interacting galaxies, confirming recent findings. When comparing the optical properties of CSS/GPS and MPS sources, we do not find any significant difference. Finally, the Mid-Infrared WISE colours analysis suggests that the compact radio sources defined as powerful AGNs are, in general, gas-rich systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Redshifts of radio sources in the Million Quasars Catalogue from machine learning

ABSTRACT With the aim of using machine learning techniques to obtain photometric redshifts based upon a source’s radio spectrum alone, we have extracted the radio sources from the Million Quasars Catalogue. Of these, 44 119 have a spectroscopic redshift, required for model validation, and for which photometry could be obtained. Using the radio spectral properties as features, we fail to find a model which can reliably predict the redshifts, although there is the suggestion that the models improve with the size of the training sample. Using the near-infrared–optical–ultraviolet bands magnitudes, we obtain reliable predictions based on the 12 503 radio sources which have all of the required photometry. From the 80:20 training–validation split, this gives only 2501 validation sources, although training the sample upon our previous SDSS model gives comparable results for all 12 503 sources. This makes us confident that SkyMapper, which will survey southern sky in the u, v, g, r, i, z bands, can be used to predict the redshifts of radio sources detected with the Square Kilometre Array. By using machine learning to impute the magnitudes missing from much of the sample, we can predict the redshifts for 32 698 sources, an increase from 28 to 74 per cent of the sample, at the cost of increasing the outlier fraction by a factor of 1.4. While the ‘optical’ band data prove successful, at this stage we cannot rule out the possibility of a radio photometric redshift, given sufficient data which may be necessary to overcome the relatively featureless radio spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Diffuse sources, clustering, and the excess anisotropy of the radio synchrotron background

ABSTRACT We present the largest low frequency (120 MHz) arcminute resolution image of the radio synchrotron background (RSB) to date, and its corresponding angular power spectrum of anisotropies (APS) with angular scales ranging from 3° to 0.3 arcmin. We show that the RSB around the north celestial pole has a significant excess anisotropy power at all scales over a model of unclustered point sources based on source counts of known source classes. This anisotropy excess, which does not seem attributable to the diffuse Galactic emission, could be linked to the surface brightness excess of the RSB. To better understand the information contained within the measured APS, we model the RSB varying the brightness distribution, size, and angular clustering of potential sources. We show that the observed APS could be produced by a population of faint clustered point sources only if the clustering is extreme and the size of the Gaussian clusters is ≲1 arcmin. We also show that the observed APS could be produced by a population of faint diffuse sources with sizes ≲1 arcmin, and this is supported by features present in our image. Both of these cases would also cause an associated surface brightness excess. These classes of sources are in a parameter space not well probed by even the deepest radio surveys to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter substructure or source model systematics? A case study of cluster lens Abell S1063

Mapping the small-scale structure of the universe through gravitational lensing is a promising tool for probing the particle nature of dark matter. Curved Arc Basis (CAB) has been proposed as a local lensing formalism in galaxy clusters, with the potential to detect low-mass dark matter substructure. In this work, we analyse the cluster lens Abell S1063 in search of dark matter substructure with the CAB formalism, using multiband imaging data from James Webb Space Telescope ( JWST ). We use two different source modelling methods: shapelets and pixel-based source reconstruction based on Delaunay triangulation. We find that source modelling systematics from shapelets result in a disagreement between CAB parameters measured from different filters. Source modelling with Delaunay significantly alleviates this systematic, as seen in the improvement in agreement across filters. We also find that inadequate complexity in source modelling can result in convincing spurious detections of dark matter substructure from strong gravitational lenses, as seen by our $\Delta \text{BIC} > 20$ measurement of a $M \sim 10^{10}$ ${\rm M}_{\odot }$ subhalo with shapelets, a spurious detection that is not reproduced with Delaunay source modelling. We demonstrate that multiband analysis with different JWST filters is key for disentangling source and lens model systematics from dark matter substructure detections.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling study of a proposed field calibration source using K-40 and high-Z targets for sodium iodide detectors

Calibration sources based on the primordial isotope potassium-40 ( 40 K) have reduced controls on the source’s activity due to its terrestrial ubiquity and very low specific activity. Potassium–40’s beta emissions and 1,460.8 keV gamma ray can be used to induce K-shell fluorescence x rays in high-Z metals between 60 and 80 keV. A gamma ray calibration source that uses potassium chloride salt and a high-Z metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument is thus proposed. The calibration source was designed in collaboration with the Sandia National Laboratory using the Monte Carlo N-Particle eXtended (MCNPX) transport code. Two methods of x-ray production were explored. First, a thin high-Z layer (HZL) was interposed between the detector and the potassium chloride-urethane source matrix. Second, bismuth metal powder was homogeneously mixed with a urethane binding agent to form a potassium chloride-bismuth matrix (KBM). The bismuth-based source was selected as the development model because it is inexpensive, nontoxic, and outperforms the high-Z layer method in simulation. As a result, based on the MCNPX studies, sealing a mixture of bismuth powder and potassium chloride into a thin plastic case could provide a light, inexpensive field calibration source.

40K↗

Setup and Characterization of a 137 CS Dosimetry Calibration Source in a Space-constrained Environment

Proper characterization of 137 Cs sources used for dosimeter calibration and performance testing is crucial for accurate and precise knowledge of air kerma rate and delivered dose. A 269 GBq 137 Cs source was relocated to a new facility, which had a footprint of approximately 2.8 m × 3.6 m and a 3.4 m high ceiling. A small room size, such as in the new facility, may significantly increase backscatter from the walls or room return. Due to the limited source strength, a relatively close irradiation position of 1.00 m from the source was selected to decrease required exposure times. Proximity to the small but cylindrical source has the potential to alter the 1/r 2 relationship (inverse square law) of air kerma rate with distance associated with point sources. Practical tutorials concerning dosimetry irradiation facilities are largely absent from the archival literature. For those reasons, standard characterization experiments were repeated multiple times, great care was taken with positioning, several experiments were added to the standard ones, an ion chamber and dosimeters were used rather than film for greater accuracy and precision, and practical details of the process were recorded. The impacts of room size and finite source dimensions were quantified and mitigated by the efforts reported here. Finally, recommendations for simple but thorough facility characterization, beam calibration, and quality control resulted.

42 ENGINEERING↗

Energy Distribution of the Galactic Center Excess’s Sources

The Galactic Center Excess (GCE) may yet herald the discovery of annihilating dark matter. Weighing against that conclusion are analyses showing evidence for dim point sources within the spatial structure of the emission. Because of technical limitations these analyses are purely spatial with all spectral information that could disentangle the excess from astrophysical backgrounds discarded. Here, we demonstrate that a neural network simulation-based inference approach can jointly analyze the spatial and spectra data. The addition is profound: energy information drives the putative point sources to be significantly dimmer, indicating either the GCE is truly diffuse in nature or made of an exceptionally large number of sources. Quantitatively, for our best fit background model, the excess is essentially consistent with Poisson emission as predicted by dark matter. If due to point sources, our median prediction is O(10^{5}) sources, or more than 35 000 at 90% confidence-both orders of magnitude larger than the hundreds preferred by earlier point-source analyses of the GCE, although variations allowed by background systematics could reduce the required number of sources by roughly an order of magnitude.

List, Florian↗

Mach cones in the quark-gluon plasma: Viscosity, speed of sound, and effects of finite source structure

I use the space-time distribution of energy and momentum deposited by a fast parton traversing a perturbative quark-gluon plasma as a source term for the linearized hydrodynamical equations of the medium. A method of solution for the medium response is presented in detail. Numerical results are given for different values of the shear viscosity to entropy density ratio, {eta}/s, and speed of sound, c{sub s}. Furthermore, I investigate the relevance of finite source structure by expanding the source term up to first order in gradients of a {delta} function centered at the fast parton and comparing the resulting dynamics to that obtained with the full source. It is found that, for the source term used here, the medium response is sensitive to the finite source structure up to distances of several femtometers from the source parton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristic quantities of pion-emitting sources extracted by model-independent analysis in relativistic heavy ion collisions

We examine the characteristic quantities of pion-emitting sources extracted by model-independent imaging analysis in relativistic heavy ion collisions. The moments of the spatial separation of pion pair emission can provide the characteristic information about the source geometry and coherence. They are better for describing the non-Gaussian sources with granular and core-halo structures. An improved granular source model of quark-gluon plasma droplets can reproduce the main characteristics of the two-pion correlation functions and source functions in the experiment of {radical}(s{sub NN})=200 GeV Au+Au collisions. The transverse-momentum dependence of the normalized first-order moments of the separation for the granular source is consistent with that of the usual interferometry results of source radii, after taking into account the Lorentz contraction in the direction of the transverse momentum of the pion pair.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

3D modeling of deep borehole electromagnetic measurements with energized casing source for fracture mapping at the Utah Frontier Observatory for Research in Geothermal Energy

Here, we present a 3D numerical modelling analysis evaluating the deployment of a borehole electromagnetic measurement tool to detect and image a stimulated zone at the Utah Frontier Observatory for Research in Geothermal Energy geothermal site. As the depth to the geothermal reservoir is several kilometres and the size of the stimulated zone is limited to several 100 m, surface-based controlled-source electromagnetic measurements lack the sensitivity for detecting changes in electrical resistivity caused by the stimulation. To overcome the limitation, the study evaluates the feasibility of using a three-component borehole magnetic receiver system at the Frontier Observatory for Research in Geothermal Energy site. To provide sufficient currents inside and around the enhanced geothermal reservoir, we use an injection well as an energized casing source. To efficiently simulate energizing the injection well in a realistic 3D resistivity model, we introduce a novel modelling workflow that leverages the strengths of both 3D cylindrical-mesh-based electromagnetic modelling code and 3D tetrahedral-mesh-based electromagnetic modelling code. The former is particularly well-suited for modelling hollow cylindrical objects like casings, whereas the latter excels at representing more complex 3D geological structures. In this workflow, our initial step involves computing current densities along a vertical steel-cased well using a 3D cylindrical electromagnetic modelling code. Subsequently, we distribute a series of equivalent current sources along the well's trajectory within a complex 3D resistivity model. We then discretize this model using a tetrahedral mesh and simulate the borehole electromagnetic responses excited by the casing source using a 3D finite-element electromagnetic code. This multi-step approach enables us to simulate 3D casing source electromagnetic responses within a complex 3D resistivity model, without the need for explicit discretization of the well using an excessive number of fine cells. We discuss the applicability and limitations of this proposed workflow within an electromagnetic modelling scenario where an energized well is deviated, such as at the Frontier Observatory for Research in Geothermal Energy site. Using the workflow, we demonstrate that the combined use of the energized casing source and the borehole electromagnetic receiver system offer measurable magnetic field amplitudes and sensitivity to the deep localized stimulated zone. The measurements can also distinguish between parallel-fracture anisotropic reservoirs and isotropic cases, providing valuable insights into the fracture system of the stimulated zone. Besides the magnetic field measurements, vertical electric field measurements in the open well sections are also highly sensitive to the stimulated zone and can be used as additional data for detecting and imaging the target. We can also acquire additional multiple-source data by grounding the surface electrode at various locations and repeating borehole electromagnetic measurements. This approach can increase the number of monitoring data by several factors, providing a more comprehensive dataset for analysing the deep-localized stimulated zone. The numerical analysis indicates that it is feasible to use the combination of the energized casing and downhole electromagnetic measurements in monitoring localized stimulated zone at large depths.

58 GEOSCIENCES↗

Simple self-gettering differential-pump for minimizing source oxidation in oxide-MBE environment

Source oxidation of easily oxidizing elements such as Ca, Sr, Ba, and Ti in an oxidizing ambient leads to their flux instability and is one of the biggest problems in the multielemental oxide molecular beam epitaxy technique. Here, the authors report a new scheme that can completely eliminate the source oxidation problem: a self-gettering differential pump using the source itself as the pumping medium. The pump simply comprises a long collimator mounted in front of the source in extended port geometry. With this arrangement, the oxygen partial pressure near the source was easily maintained well below the source oxidation regime, resulting in a stabilized flux, comparable to that of an ultrahigh-vacuum environment. Moreover, this pump has a self-feedback mechanism that allows a stronger pumping effectiveness for more easily oxidizing elements, which is a desired property for eliminating the source oxidation problem.

36 MATERIALS SCIENCE↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed brachytherapy source

Purpose: AAPM TG-43 brachytherapy dosimetry parameters for a new, smaller diameter {sup 125}I brachytherapy source (THINSeed, model 9011) were determined using LiF:Mg,Ti thermoluminescent dosimeter (TLD-100) microcubes and Monte Carlo simulations. Methods: Two polymethyl methacrylate phantoms were machined to hold TLD-100 microcubes at specific locations for the experimental determination of the radial dose function, dose-rate constant, and anisotropy functions of the new source. The TG-43 parameters were also calculated using Monte Carlo simulations. For comparison, the model 6711 source was also investigated. Results: Experimental results for both models 9011 and 6711 sources showed good agreement with Monte Carlo values, as well as with previously published values. Conclusions: The TG-43 parameters for the new source model are similar to those of model 6711; however, they represent two separate sources and TG-43 parameters used in treatment planning must be source specific.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of absorbed dose-to-water for an HDR {sup 192}Ir source with ionization chambers in a sandwich setup

Purpose: In this study, a dedicated device for ion chamber measurements of absorbed dose-to-water for a Nucletron microSelectron-v2 HDR {sup 192}Ir brachytherapy source is presented. The device uses two ionization chambers in a so-called sandwich assembly. Using this setup and by taking the average reading of the two chambers, any dose error due to difficulties in absolute positioning (centering) of the source in between the chambers is cancelled to first order. The method's accuracy was examined by comparing measurements with absorbed dose-to-water determination based on the AAPM TG-43 protocol.Methods: The optimal source-to-chamber distance (SCD) for {sup 192}Ir dosimetry was determined from ion chamber measurements in a water phantom. The {sup 192}Ir source was sandwiched between two Exradin A1SL chambers (0.057 cm{sup 3}) at the optimal SCD separation. The measured ionization was converted to the absorbed dose-to-water using a {sup 60}Co calibration factor and a Monte Carlo-calculated beam quality conversion factor, k{sub Q}, for {sup 60}Co to {sup 192}Ir. An uncertainty estimate of the proposed method was determined based on reproducibility of measurements at different institutions for the same type of source.Results: The optimal distance for the A1SL chamber measurements was determined to be 5 cm from the {sup 192}Ir source center, considering the depth dependency of k{sub Q} for {sup 60}Co to {sup 192}Ir and the chamber positioning. The absorbed dose to water measured at (5 cm, 90°) on the transverse axis was 1.3% lower than TG-43 values and its reproducibility and overall uncertainty were 0.8% and 1.7%, respectively. The measurement doses at anisotropic points agreed within 1.5% with TG-43 values.Conclusions: The ion chamber measurement of absorbed dose-to-water with a sandwich method for the {sup 192}Ir source provides a more accurate, direct, and reference dose compared to the dose-to-water determination based on air-kerma strength in the TG-43 protocol. Due to the simple but accurate assembly, the sandwich measurement method is useful for daily dose management of {sup 192}Ir sources.

61 RADIATION PROTECTION AND DOSIMETRY↗