Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Clinical Evaluation of a Laser Surface Scanning System in 120 Patients for Improving Daily Setup Accuracy in Fractionated Radiation Therapy

Purpose: To evaluate the clinical suitability of a specific optical surface imaging system to detect setup errors in fractionated radiation therapy. Methods and Materials: The setup correction accuracy of a 3-dimensional laser imaging system was analyzed for 6 different tumor locations with 20 patients each. For each patient, the setup corrections of the megavoltage computed tomography (MVCT) images of a TomoTherapy unit (TomoTherapy, Madison, WI) were compared with those of the laser system for the first 10 fractions. For the laser system, the reference surface either was obtained from the DICOM (Digital Imaging and Communications in Medicine) surface structure delineated on the planning computed tomography images or was acquired with the system itself at the first fraction after the MVCT-based setup correction. Data analysis was performed for both reference types. Results: By use of the DICOM reference image, systematic shifts between 3 and 9 mm were found, depending on the tumor location. For the optical reference, no clinically relevant systematic shifts were found. MVCT-based setup corrections were detected with high accuracy, and only small movements were observed during treatment. Conclusions: Using a reference image acquired with the laser system itself after MVCT-based setup correction appears more reliable than importing the DICOM reference surface. After generation of the optical reference, the laser system may be used to derive setup corrections over a certain number of fractions, but additional radiologic imaging may still be necessary on a regular basis (eg, weekly) or if the corrections of the optical system appear implausibly large. Nevertheless, such a combined application may help to reduce the imaging dose for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray multiphoton-induced Coulomb explosion images complex single molecules

Following structural dynamics in real time is a fundamental goal towards a better understanding of chemical reactions. Recording snapshots of individual molecules with ultrashort exposure times is a key ingredient towards this goal, as atoms move on femtosecond (10 -15 s) timescales. For condensed-phase samples, ultrafast, atomically resolved structure determination has been demonstrated using X-ray and electron diffraction. Pioneering experiments have also started addressing gaseous samples. However, they face the problem of low target densities, low scattering cross sections and random spatial orientation of the molecules. Therefore, obtaining images of entire, isolated molecules capturing all constituents, including hydrogen atoms, remains challenging. Here we demonstrate that intense femtosecond pulses from an X-ray free-electron laser trigger rapid and complete Coulomb explosions of 2-iodopyridine and 2-iodopyrazine molecules. We obtain intriguingly clear momentum images depicting ten or eleven atoms, including all the hydrogens, and thus overcome a so-far impregnable barrier for complete Coulomb explosion imaging—its limitation on molecules consisting of three to five atoms. In combination with state-of-the-art multi-coincidence techniques and elaborate theoretical modelling, this allows tracing ultrafast hydrogen emission and obtaining information on the result of intramolecular electron rearrangement. Our work represents an important step towards imaging femtosecond chemistry via Coulomb explosion.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tensile stress effect on epitaxial BiFeO 3 thin film grown on KTaO 3

Comprehensive crystal structural study is performed for BiFeO 3 (BFO) film grown on KTaO 3 (KTO) substrate using transmission electron microscopy (TEM) and x-ray diffraction (XRD). Nano beam electron diffraction (NBED) combined with structure factor calculation and high resolution TEM images clearly reveal that the crystal structure within BFO thin film is rhombohedral BFO, i.e., bulk BFO phase. Epitaxial relationship found by NBED indicates the BFO film grows in a manner that minimizes lattice mismatch with KTO. It further suggests BFO film is under slight biaxial tensile stress (~0.35%) along in-plane direction. XRD reveals BFO lattice is under compressive stress (~1.6%), along out-of-plane direction as a result of the biaxial tensile stress applied along in-plane direction. This leads to Poisson’s ratio of ~0.68. In addition, we demonstrate (1) why hexagonal notation rather than pseudocubic one is required for accurate BFO phase evaluation and (2) a new XRD method that shows how rhombohedral BFO can readily be identified among other phases by measuring a rhombohedral specific Bragg’s peak.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of a magnetograph and X-ray telescope to the study of coronal structure variations

The application of magnetographs and X-ray imaging techniques to determine the magnitude, structure, origin, and evolution of the solar coronal magnetic field is examined. The spatial and temporal resolution of the X-ray telescope is discussed and a comparison of ground based magnetogram sequences versus a magnetograph in space is presented. Skylab photographs of the evolution of transient coronal holes are provided.

Rust, D. M.↗

Rings and moons - Clues to understanding the solar nebula

Planetary satellites, ranging in size from ring particles to the Galilean moons of Jupiter, constitute a small but diverse compmonent of the solar system. In some respects, the satellite systems of the giant planets can be thought of as miniature solar systems. The chemical and physical properties of these systems can yield clues to the conditions under which they may have formed, and thus can constrain models of the circumplanetary nebulae and the solar nebula. Planetary rings contain a great deal of structure, most strikingly displayed in Voyager spacecraft images. Understanding the causes of this structure can yield important insights into the dynamics of the protoplanetary disk. Taken together, rings and moons offer clues as to the nature of the processes which led to the formation of the planets themselves.

Lissauer, J. J.↗

Mosaic CCD method: A new technique for observing dynamics of cometary magnetospheres

On April 29, 1990, the plasma tail of Comet Austin was observed with a CCD camera on the 105-cm Schmidt telescope at the Kiso Observatory of the University of Tokyo. The area of the CCD used in this observation is only about 1 sq cm. When this CCD is used on the 105-cm Schmidt telescope at the Kiso Observatory, the area corresponds to a narrow square view of 12 ft x 12 ft. By comparison with the photograph of Comet Austin taken by Numazawa (personal communication) on the same night, we see that only a small part of the plasma tail can be photographed at one time with the CCD. However, by shifting the view on the CCD after each exposure, we succeeded in imaging the entire length of the cometary magnetosphere of 1.6 x 10(exp 6) km. This new technique is called 'the mosaic CCD method'. In order to study the dynamics of cometary plasma tails, seven frames of the comet from the head to the tail region were twice imaged with the mosaic CCD method and two sets of images were obtained. Six microstructures, including arcade structures, were identified in both the images. Sketches of the plasma tail including microstructures are included.

Saito, T.↗

Iridium Atoms Bonded to Crystalline Powder MgO: Characterization by Imaging and Spectroscopy

Samples with low loadings of metals on well-defined supports provide some of the best opportunities to determine the metal–support structure and bonding. We illustrate methods for characterizing atomically dispersed heavy metals on metal oxide supports by aberration-corrected scanning transmission electron microscopy (STEM) complemented by fluorescence detection extended X-ray absorption fine structure and infrared spectroscopies. STEM images of Ir atoms derived from Ir(C 2 H 4 ) 2 (acac) (acac = acetylacetonato) on high-surface-area MgO powder were obtained with minimized electron beam damage by quickly recording images near where the focus had been established. The images show that iridium at a loading of 1.0 wt % on MgO calcined at 1073 K was atomically dispersed, populating much of the surface of the MgO particles, which had irregular shapes—consequently the Ir atoms were bonded at various sites to two or three surface O atoms. In contrast, MgO calcined at 1273 K consisted of almost perfectly cubic crystals, and Ir atoms at a loading of only 0.01 wt % on this nearly ideal support were anchored preferentially at edges and corners of the (100) faces and bonded to three surface O atoms. The latter results indicate a path forward for the determination of precise structures of atomically dispersed metals on crystalline metal oxide supports.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Jovian cloud structure and velocity fields

A global view of Jovian small-scale morphologies and zonal velocity profiles has been discussed previously. In the present paper, a regional comparison is made of the structures and velocity fields (meridional and zonal velocities) in the Jovian atmosphere as observed by Voyager I imaging system. The cloud structures discussed are fairly independent of the visual wavelength. The analysis shows that although both Jovian hemispheres exhibit similar patterns of diminishing and alternating eastward and westward jets as one progresses polewards, there is a pronounced asymmetry in the structural appearance of the two hemispheres.

Mitchell, J. L.↗

Digital image filtering in visualized boundary layers

The application of two-dimensional low-pass matched filtering is presented for use in objective processing of digitized flow visualization images in order to identify instantaneous large-scale organized structures in turbulent boundary layers. The images were digitally acquired simultaneously with the outputs of a two-dimensional rake of hot-wire sensors in the field of view of the digital camera. Two-dimensional low wavenumber analysis brought out patterns in the visualization images which consisted of slender inclined structures having an average streamwise scale of 100-200 v/u (tau) and a length on the order of 1-2 delta. The similarly processed two-dimensional streamwise velocity reconstructions reveal similar features. The ensemble statistics indicate that these inclined features brought out by this processing may be a basic flow module in higher Reynolds number flows which links the so-called wall 'bursting' process and the larger outer scale motions.

Corke, T. C.↗

Revisiting Competing Paths in Electrochemical CO 2 Reduction on Copper via Embedded Correlated Wavefunction Theory

We re-evaluate two key steps in the mechanism of CO 2 reduction on copper at a higher level of theory capable of correcting inherent errors in density functional theory (DFT) approximations, namely, embedded correlated wavefunction (ECW) theory. Here, we consider the CO reduction step on Cu(111), which is critical to understanding reaction selectivity. Here, we optimize embedding potentials at the periodic plane-wave DFT level using density functional embedding theory (DFET). All possible adsorption sites (adsites) for each adsorbate then are screened with ECW theory at the catalytically active site to refine the local electronic structure. Unsurprisingly, DFT and ECW theory predict different adsite preferences, largely because of DFT’s inability to properly situate the CO 2π* level. Differing preferred adsites suggest that different reaction pathways could emerge from DFT versus ECW theory. Starting from these preferred ECW theory adsites, we then obtain reaction pathways at the plane-wave DFT level using the climbing-image nudged elastic band method to determine minimum energy paths. Thereafter, we perform ECW calculations at the catalytically active site to correct the energetics at each interpolated structure (image) along the reaction pathways. Via this approach, we confirm that the first step in CO reduction via hydrogen transfer on Cu(111) is to form hydroxymethylidyne (*COH) instead of formyl (*CHO). Although the prediction to preferentially form *COH is consistent with that of DFT, the two theories predict quite different structural and mechanistic behaviors, suggesting that verification is needed for other parts of the mechanism of CO 2 reduction, which is the subject of ongoing work.

30 DIRECT ENERGY CONVERSION↗

Uncovering the three-dimensional structure of upconverting core–shell nanoparticles with multislice electron ptychography

In photon upconverting core–shell nanoparticles, structure strongly dictates performance. Typical imaging in scanning transmission electron microscopy has sufficient resolution to probe the atomic structure of these nanoparticles, but contrast, dose, and projection limitations make conventional methods insufficient for fully characterizing these structures. Phase retrieval techniques provide a promising alternative imaging mode, and, in particular, multislice electron ptychography can recover depth-dependent information. Here, we study beam-sensitive photon upconverting core–shell nanoparticles with a multislice ptychography approach using a low electron dose to avoid damage. Large strain fields arise in these heterostructures due to the mismatch in lattice parameter between the core and the shell. We reconstruct both a nanoparticle that appears defect-free and one that has a large break in the side and map the distribution of strain in 3D by computing distortion fields from high-resolution potential images of each slice. In the defect-free nanoparticle, we observe twisting of the shell, while in the broken nanoparticle, we measure the 3D position of the crack, the core, and dislocations. These results highlight the advantage of multislice electron ptychography to recover 3D information from a single scan, even under strict electron dose requirements from beam-sensitive samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

Three-dimensional temporal reconstruction and analysis of plume images

An experiment with two subsonic jets generating a cross-flow was conducted as part of a study of the structural features of temporal reconstruction of plume images. The flow field structure was made visible using a direct injection flow visualization technique. It is shown that image analysis and temporal three-dimensional visualization can provide new information on the vortical structural dynamics of multiple jets in a cross-flow. It is expected that future developments in image analysis, quantification and interpretation, and flow visualization of rocket engine plume images may provide a tool for correlating the engine diagnostic features by interpreting the evolution of the structures in the plume.

Dhawan, Atam P.↗

Diagnosing the Structure of the HD 163296 Protoplanetary Disk Via Coronagraphic Imaging Polarimetry

Coronagraphic imaging polarimetry is a high contrast imaging technique which can diagnose both the spatial distribution and size distribution of dust grains which comprise primordial protoplanetary disks. It can therefore be a useful tool to test our understanding of how the structure of young disks evolves through the era of gas giant planet formation. We report our initial analysis of the H-band polarized and total intensity of the nearby Herbig Ae star HD 163296, and characterize the morphology of the scattered light disk in the context of previous optical HST coronagraphic imagery. Our observations were obtained as part of a multi-epoch campaign designed to diagnose and correlate the behavior of the inner and outer regions of select protoplanetary disks. This campaign will help test recent suggestions (Sitko et al. 2008; Wisniewski et al. 2008) that that HD 163296 dis experiences the novel phenomenon of time-variable self-shadowing, whereby occasional changes in the scale height of the inner disk wall induces changes in the illumination of the outer disk.

Kowalski, Adam F.↗

Effect of Breast Compression on Lesion Characteristic Visibility with Diffraction-Enhanced Imaging

Conventional mammography can not distinguish between transmitted, scattered, or refracted x-rays, thus requiring breast compression to decrease tissue depth and separate overlapping structures. Diffraction-enhanced imaging (DEI) uses monochromatic x-rays and perfect crystal diffraction to generate images with contrast based on absorption, refraction, or scatter. Because DEI possesses inherently superior contrast mechanisms, the current study assesses the effect of breast compression on lesion characteristic visibility with DEI imaging of breast specimens. Eleven breast tissue specimens, containing a total of 21 regions of interest, were imaged by DEI uncompressed, half-compressed, or fully compressed. A fully compressed DEI image was displayed on a soft-copy mammography review workstation, next to a DEI image acquired with reduced compression, maintaining all other imaging parameters. Five breast imaging radiologists scored image quality metrics considering known lesion pathology, ranking their findings on a 7-point Likert scale. When fully compressed DEI images were compared to those acquired with approximately a 25% difference in tissue thickness, there was no difference in scoring of lesion feature visibility. For fully compressed DEI images compared to those acquired with approximately a 50% difference in tissue thickness, across the five readers, there was a difference in scoring of lesion feature visibility. The scores for this difference in tissue thickness were significantly different at one rocking curve position and for benign lesion characterizations. These results should be verified in a larger study because when evaluating the radiologist scores overall, we detected a significant difference between the scores reported by the five radiologists. Reducing the need for breast compression might increase patient comfort during mammography. Our results suggest that DEI may allow a reduction in compression without substantially compromising clinical image quality.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging Laser Altimetry in the Amazon: Mapping Large Areas of Topography, Vegetation Height and Structure, and Biomass

A flight mission of NASA GSFC's Laser Vegetation Imaging Sensor (LVIS) is planned for June-August 2003 in the Amazon region of Brazil. The goal of this flight mission is to map the vegetation height and structure and ground topography of a large area of the Amazon. This data will be used to produce maps of true ground topography, vegetation height, and estimated above-ground biomass and for comparison with and potential calibration of Synthetic Aperture Radar (SAR) data. Approximately 15,000 sq. km covering various regions of the Amazon will be mapped. The LVIS sensor has the unique ability to accurately sense the ground topography beneath even the densest of forest canopies. This is achieved by using a high signal-to-noise laser altimeter to detect the very weak reflection from the ground that is available only through small gaps in between leaves and between tree canopies. Often the amount of ground signal is 1% or less of the total returned echo. Once the ground elevation is identified, that is used as the reference surface from which we measure the vertical height and structure of the vegetation. Test data over tropical forests have shown excellent correlation between LVIS measurements and biomass, basal area, stem density, ground topography, and canopy height. Examples of laser altimetry data over forests and the relationships to biophysical parameters will be shown. Also, recent advances in the LVIS instrument will be discussed.

Blair, J. Bryan↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

Correlating 3D Surface Atomic Structure and Catalytic Activities of Pt Nanocrystals

Active sites and catalytic activity of heterogeneous catalysts is determined by their surface atomic structures. However, probing the surface structure at an atomic resolution is difficult, especially for solution ensembles of catalytic nanocrystals, which consist of heterogeneous particles with irregular shapes and surfaces. In this study, we constructed 3D maps of the coordination number (CN) and generalized CN ($\bar{C}\bar{N}$) for individual surface atoms of sub-3 nm Pt nanocrystals. Our results reveal that the synthesized Pt nanocrystals are enclosed by islands of atoms with nonuniform shapes that lead to complex surface structures, including a high ratio of low-coordination surface atoms, reduced domain size of low-index facets, and various types of exposed high-index facets. 3D maps of $\bar{C}\bar{N}$ are directly correlated to catalytic activities assigned to individual surface atoms with distinct local coordination structures, which explains the origin of high catalytic performance of small Pt nanocrystals in important reactions such as oxygen reduction reactions and CO electro-oxidation.

3D atomic structure↗