Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Enhanced photothermal lens using a photonic crystal surface

A photonic crystal (PC)-enhanced photothermal lens (PTL) is demonstrated for the detection of optically thin light absorption materials. The PC-enhanced PTL system is based on a pump-probe scheme consisting of a PC surface, pump laser beam, and probe laser beam. Heated by the pump beam, light absorption materials on the PC surface generate the PTL and cause a substantial change to the guided-mode resonance supported by the PC structure. The change of the PC resonance is detected using the probe laser beam by measuring its reflectivity from the PC surface. When applied to analyze dye molecules deposited on the PC substrate, the developed system is capable of enhancing the PTL signal by 10-fold and reducing the lowest distinguishable concentration by 8-fold, in comparison to measuring without utilizing the PC resonance. The PC-enhanced PTL was also used to detect gold nanoparticles on the PC surface and exhibited a 20-fold improvement of the lowest distinguishable concentration. The PC-enhanced PTL technology offers a potential tool to obtain the absorption signatures of thin films in a broad spectral range with high sensitivity and inexpensive instrumentation. As a result, this technology will enable a broad range of applications of photothermal spectroscopy in chemical analysis and biomolecule sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Emission Profile And Neutron Spectrum Measurements At JET: Status And Plans

In large tokamak devices, such as JET, TFTR, JT-60U and ITER, a neutron emission profile monitor is considered as one of the principal diagnostic tools, firstly in providing information to characterize the fusion source in terms of its location, shape, intensity and secondly in developing an understanding of fast ion physics in tokamak plasmas. The JET neutron profile monitor is one of the most advanced such instruments currently operating. It enables 2-D imaging of the non-circular plasma neutron source through a tomographic deconvolution of line-integrated measurements. Historically it was usually assumed that the fusion neutron source is a function of the magnetic flux surfaces (MFS), but recent JET results have clearly demonstrated the influence of non-uniform fast particle populations on the neutron emission profile.Neutron energy spectroscopy also carries valuable information about fast ion behaviour and the fusion and nuclear reactions taking place in the plasma. Spectrum measurements of neutrons will be particularly important for the up-coming JET experiments with a Be wall. The neutron spectroscopy capabilities at JET were recently enhanced by several instruments: a new time-of-flight spectrometer optimized for high count rates (TOFOR), compact neutron spectrometers based on organic scintillator (NE213) and an upgrade of the Magnetic Proton Recoil system (MPRu). In recent JET campaigns, a prototype digital pulse shape discriminator (DPSD) has been successfully tested on one central chord of the JET neutron profile monitor and spectral information has also been obtained. Neutron spectrometry results obtained during the last JET experimental campaigns illustrate the measurement capabilities and indicate their potential use on ITER. Several projects are in progress to further develop such diagnostic capabilities and these are briefly summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Project Title: Development of a Pipe Crawler Inspection Tool for Fossil Energy Power Plants (Final Report)

This research effort focuses on the development of a pipe crawler inspection tool for fossil energy power plants. The pipe crawler is tethered and can navigate through 2 inch pipes that are often found in various systems within a power plant. The crawler can navigate through straight pipes and 180 degree elbows and includes instrumentation that can assess the integrity of the pipes. The sensors include a UT sensor for measuring the thickness of the pipe, a range finder and a camera. An additional module is used to prep the surface of the pipe prior to taking thickness measurements. Both bench scale and engineering scale testing was conducted to demonstrate the concept. Multiple crawlers were created and tethered together to distribute the load of the tether so that the crawler can navigate longer pipe distances.

01 COAL, LIGNITE, AND PEAT↗

Dynamic tunneling force microscopy for characterizing electronic trap states in non-conductive surfaces

Dynamic tunneling force microscopy (DTFM) is a scanning probe technique for real space mapping and characterization of individual electronic trap states in non-conductive films with atomic scale spatial resolution. The method is based upon the quantum mechanical tunneling of a single electron back and forth between a metallic atomic force microscopy tip and individual trap states in completely non-conducting surface. This single electron shuttling is measured by detecting the electrostatic force induced on the probe tip at the shuttling frequency. In this paper, the physical basis for the DTFM method is unfolded through a physical model and a derivation of the dynamic tunneling signal as a function of several experimental parameters is shown. Experimental data are compared with the theoretical simulations, showing quantitative consistency and verifying the physical model used. The experimental system is described and representative imaging results are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE PROPERTIES OF X-RAY LUMINOUS YOUNG STELLAR OBJECTS IN THE NGC 1333 AND SERPENS EMBEDDED CLUSTERS

We present new Chandra X-ray data of the NGC 1333 embedded cluster and combine these data with existing Chandra data, Spitzer photometry, and ground-based spectroscopy of both the NGC 1333 and Serpens cloud core clusters to perform a detailed study of the X-ray properties of two of the nearest embedded clusters to the Sun. We first present new, deeper observations of NGC 1333 with Chandra ACIS-I and combine these with existing Spitzer observations of the region. In NGC 1333, a total of 95 cluster members are detected in X-rays of which 54 were previously identified in the Spitzer data. Of the Spitzer-identified sources, we detected 23% of the Class I protostars, 53% of the flat-spectrum sources, 52% of the Class II, and 50% of the transition disk young stellar objects (YSOs). Forty-one Class III members of the cluster are identified, bringing the total identified YSO population to 178. The X-ray luminosity functions (XLFs) of the NGC 1333 and Serpens clusters are compared to each other and the Orion Nebula Cluster (ONC). Based on a comparison of the XLFs of the Serpens and NGC 1333 clusters to the previously published ONC, we obtain a new distance for the Serpens cluster of 360{sup +22}{sub -13} pc. Using our previously published spectral types, effective temperatures, and bolometric luminosities, we analyze the dependence of the X-ray emission on the measured stellar properties. The X-ray luminosity was found to depend on the calculated bolometric luminosity as in previous studies of other clusters. We examine the dependence of L{sub X} on stellar surface area and effective temperature, and find that L{sub X} depends primarily on the stellar surface area. In the NGC 1333 cluster, the Class III sources have a somewhat higher X-ray luminosity for a given surface area. We also find evidence in NGC 1333 for a jump in the X-ray luminosity between spectral types of M0 and K7, we speculate that this may result from the presence of radiative zones in the K-stars. The gas column density versus extinction in the NGC 1333 parental molecular cloud was examined using the hydrogen column density determined from the X-ray absorption to the embedded stars and the K-band extinction measured to those stars. In NGC 1333, we find N{sub H} = 0.89 {+-} 0.13 x 10{sup 22} A{sub K} , this is lower than expected of the standard interstellar medium but similar to that found previously in the Serpens cloud core.

79 ASTRONOMY AND ASTROPHYSICS↗

The chemical compositions of RR Lyrae type c variable stars

We present a detailed chemical abundance study of eight RR Lyrae variable stars of subclass c (RRc). The target RRc stars chosen for study exhibit 'Blazhko-effect' period and amplitude modulations to their pulsational cycles. Data for this study were gathered with the echelle spectrograph of the 100 inch du Pont telescope at Las Campanas Observatory. Spectra were obtained throughout each star's pulsation cycle. Atmospheric parameters—effective temperature, surface gravity, microturbulent velocity, and metallicity—were derived at multiple phase points. We found metallicities and element abundance ratios to be constant within observational uncertainties over the pulsational cycles of all stars. Moreover, the α-element and Fe-group abundance ratios with respect to iron are consistent with other horizontal-branch members (RRab, blue and red non-variables). Finally, we have used the [Fe/H] values of these eight RRc stars to anchor the metallicity estimates of a large-sample RRc snapshot spectroscopic study being conducted with the same telescope and instrument combination employed here.

79 ASTRONOMY AND ASTROPHYSICS↗

An improved time-of-flight method for cluster deposition and ion-scattering experiments

A molecular beam apparatus has been developed for deposition and scattering experiments of size-selected clusters. The new setup combines a bimetallic laser ablation cluster source with a collinear time-of-flight mass spectrometer. Mass selection is achieved with a pulsed electrostatic mirror. A significantly improved transmission in combination with a reduction of the kinetic energy distribution of the mass selected clusters has been obtained. Without further modification of the apparatus, surface-induced dissociation of mass selected tin clusters has been investigated, demonstrating the possibility to combine cluster beam deposition and scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolving efforts to maintain and improve XPS analysis quality in an era of increasingly diverse uses and users

Based on literature analysis, X-ray photoelectron spectroscopy (XPS) use continues to increase exponentially. This increased use is accompanied by anecdotal reports and systematic analyses indicating a growing presence of significantly flawed data analyses. Recognition of this problem within the surface analysis community has increased with an understanding that both inexperienced users and increased use of XPS outside the surface analysis community contribute to the problem. The XPS community has initiated several efforts to help address the problem, which is not unique to XPS. This paper describes some of the specific problems identified and some of the community efforts intended to address them. Here, we describe activities focused on three specific issues: (i) requests for detailed guides and protocols and bite-sized versions of information for non-experts, (ii) incomplete data and analysis reporting, and (iii) the high rate of peak fitting problems. A 2019 survey identified the need for guides, protocols, and standards to assist XPS users. One set of such guides has been published, and another is being assembled. Providing incremental bites of useful information is the goal of a series of papers on specific challenges to surface analysis with example solutions has been initiated as Notes and Insights papers in Surface and Interface Analysis. Examination of XPS-containing papers finds that information to establish the credibility and reproducibility of XPS results is often very incomplete. Unfortunately, ISO and ASTM standards require an amount of parameter reporting that seems excessive and unrealistic for many research publications. Initial approaches to develop and distribute a graded approach to parameter reporting are briefly described. Multiple efforts are underway to address the high rate of problems associated with photoelectron peak fitting. These include guides to peak fitting, guides to peak identification and fitting for specific elements, and the development of a peak fitting social network. The fitting social network is designed to facilitate interactions between new and experienced XPS users; analysts trying to fit XPS data (for publication or other reasons) can ask questions and establish dynamic conversations. Encouraging and enabling high-quality XPS analysis and reporting requires several different types of effort from all members of the surface and interface analysis community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Dimensional Imaging of Lipids and Metabolites in Tissues by Nanospray Desorption Electrospray Ionization Mass Spectrometry

Abstract Three-dimensional (3D) imaging of tissue sections is a new frontier in mass spectrometry imaging (MSI). Here we report on fast 3D imaging of lipids and metabolites associated with mouse uterine decidual cells and embryo at the implantation site on day 6 of pregnancy. 2D imaging of 16-20 serial tissue sections deposited on the same glass slide was performed using nanospray desorption electrospray ionization (nano-DESI) – an ambient ionization technique that enables sensitive localized analysis of analytes on surfaces without special sample pre-treatment. In this proof-of-principle study, nano-DESI was coupled to a high-resolution Q-Exactive instrument operated at high repetition rate of >5 Hz with moderate mass resolution of 35,000 (m/Δm at m/z 200), which enabled acquisition of the entire 3D image with a spatial resolution of ~150 μm in less than 4.5 hours. The results demonstrate localization of acetylcholine in the primary decidual zone (PDZ) of the implantation site throughout the depth of the tissue examined, indicating an important role of this signaling molecule in decidualization. Choline and phosphocholine – metabolites associated with cell growth – are enhanced in the PDZ and abundant in other cellular regions of the implantation site. Very different 3D distributions were obtained for fatty acids (FA), oleic acid and linoleic acid (FA 18:1 and FA 18:2), differing only by one double bond. Localization of FA 18:2 in the PDZ indicates its important role in decidualization while FA 18:1 is distributed more evenly throughout the tissue. In contrast, several lysophosphatidylcholines (LPC) observed in this study show donut-like distributions with localization around the PDZ. Complementary distributions with minimal overlap were observed for LPC 18:0 and FA 18:2 while the 3D image of the potential precursor phosphatidylcholine (PC 36:2) showed a significant overlap with both LPC 18:0 and FA 18:2.

Environmental Molecular Sciences Laboratory↗

Experimental design and analysis for irradiation of SiC/SiC composite tubes under a prototypic high heat flux

The purpose of this work is to design an irradiation vehicle for testing silicon carbide (SiC) fiber-reinforced SiC matrix composite cladding materials under conditions representative of a light water reactor in order to validate thermo-mechanical models of stress states in these materials due to irradiation swelling and differential thermal expansion. The design allows for a constant tube outer surface temperature in the range of 300–350 °C under a representative high heat flux (~0.66 MW/m 2 ) during one cycle of irradiation in an un-instrumented “rabbit” capsule in the High Flux Isotope Reactor. An engineered aluminum foil was developed to absorb the expansion of the cladding tubes, due to irradiation swelling, without changing the thermal resistance of the gap between the cladding and irradiation capsule. Finite-element analyses of the capsule were performed, and the models used to calculate thermal contact resistance were validated by out-of-pile testing and post-irradiation examination of the foils and passive SiC thermometry. Six irradiated cladding tubes (both monoliths and composites) were irradiated and subsequently disassembled in a hot cell. The calculated temperatures of passive SiC thermometry inside the capsules showed good agreement with temperatures measured post-irradiation, with two calculated temperatures falling within 10 °C of experimental measurements. Furthermore, the success of this design could lead to new opportunities for irradiation applications with materials that suffer from irradiation swelling, creep, or other dimensional changes that can affect the specimen temperature during irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scanning magnetoresistance microscopy of atom chips

Surface based geometries of microfabricated wires or patterned magnetic films can be used to magnetically trap and manipulate ultracold neutral atoms or Bose-Einstein condensates. We investigate the magnetic properties of such atom chips using a scanning magnetoresistive (MR) microscope with high spatial resolution and high field sensitivity. By comparing MR scans of a permanent magnetic atom chip to field profiles obtained using ultracold atoms, we show that MR sensors are ideally suited to observe small variations of the magnetic field caused by imperfections in the wires or magnetic materials which ultimately lead to fragmentation of ultracold atom clouds. Measurements are also provided for the magnetic field produced by a thin current-carrying wire with small geometric modulations along the edge. Comparisons of our measurements with a full numeric calculation of the current flow in the wire and the subsequent magnetic field show excellent agreement. Our results highlight the use of scanning MR microscopy as a convenient and powerful technique for precisely characterizing the magnetic fields produced near the surface of atom chips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of light collection in depolished inorganic scintillators using Monte Carlo Simulations

Scintillators are materials which emit light when energetic particles deposit energy in their volume. It is a quasi-universal requirement that the light detected in scintillator setups be maximised. The following project aims to study how the light collection is affected by surface depolishing using the simulation programs GEANT4 and LITRANI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Utilization of polymer gel as a bolus compensator and a dosimeter in the near-surface buildup region for breast-conserving therapy

Tangential beam radiotherapy is routinely used for radiation therapy after breast conserving surgery. A tissue-equivalent bolus placed on the irradiated area shifts the depth of the dose distribution; this bolus provides uniform dose distribution to the breast. The gel bolus made by the BANG-Pro{sup ®} polymer gel and in an oxygen non-transmission pack was applicable as a dosimeter to measure dose distribution in near-surface buildup region. We validated the use of the gel bolus to improve in the whole-breast/chest wall, including the near-surface buildup region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Balmer-α spectrum measurements of the LHD one-third ion source

Wavelength spectra of Balmer-α light from plasmas in the extraction region of the Large Helical Device-R&D negative ion source, or the LHD one-third ion source have exhibited a blue shift as a negative bias voltage was applied to the plasma grid. The blue shift increased as the negative bias voltage with respect to the local plasma potential was increased. The measured spectra were compared with the velocity distributions of surface reflected hydrogen atoms calculated by atomic collisions in amorphous target code. The arc power and the source H{sub 2} pressure also affected the shift and broadening in the observed Balmer-α spectra. The possibility of identifying the negative hydrogen ions produced at the low work function plasma grid surface by high resolution spectroscopy is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗

Metallic wire grid behavior and testing in a low pressure gaseous noble elements detector

High voltage performance has been a challenge for noble element detectors. One piece of this challenge is the emission of electrons from metal electrodes when applying high voltage. This has become a major concern for low-background detectors such as LUX-ZEPLIN (LZ). LZ is a liquid xenon Time Projection Chamber (TPC) searching for Weakly Interactive Massive Particles (WIMPs). In this work, we demonstrate a method to measure electron emission from metallic electrode grids via detection of proportional scintillation light. As a result, we find consistency with Fowler-Nordheim emission with a surface parameter β = 1988 after electro-polishing treatment of a stainless steel grid.

47 OTHER INSTRUMENTATION↗

HELIOSEISMIC RESPONSE TO THE X2.2 SOLAR FLARE OF 2011 FEBRUARY 15

The X2.2-class solar flare of 2011 February 15 produced a powerful 'sunquake' event, representing a helioseismic response to the flare impact in the solar photosphere, which was observed with the Helioseismic and Magnetic Imager (HMI) instrument on board the Solar Dynamics Observatory (SDO). The impulsively excited acoustic waves formed a compact wave packet traveling through the solar interior and appearing on the surface as expanding wave ripples. The initial flare impacts were observed in the form of compact and rapid variations of the Doppler velocity, line-of-sight magnetic field, and continuum intensity. These variations formed a typical two-ribbon flare structure, and are believed to be associated with thermal and hydrodynamic effects of high-energy particles heating the lower atmosphere. The analysis of the SDO/HMI and X-ray data from RHESSI shows that the helioseismic waves were initiated by the photospheric impact in the early impulsive phase, observed prior to the hard X-ray (50-100 keV) impulse, and were probably associated with atmospheric heating by relatively low-energy electrons ({approx}6-50 keV) and heat flux transport. The impact caused a short motion in the sunspot penumbra prior to the appearance of the helioseismic wave. It is found that the helioseismic wave front traveling through a sunspot had a lower amplitude and was significantly delayed relative to the front traveling outside the spot. These observations open new perspectives for studying the flare photospheric impacts and for using the flare-excited waves for sunspot seismology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗