Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Influence of Vibrational Loads on Needle Skew in Cardan-Joint Bearings

The influence of vibration on the operation of cardan joints is studied. An equation is derived to describe the oscillation of the needle’s skew angle in bearings under the action of the variable torque from vibrational forces. In both dynamics and statics, this angle is found to depend on the dimensions of the joint and on the load applied to a single needle in the operational zone of the bearing.

42 ENGINEERING↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗

Minimum-weight design of laminated composite plates for postbuckling performance

Minimum-weight design of simply-supported, symmetrically laminated, thin, rectangular, specially orthotropic laminated plates for buckling and postbuckling strength is investigated. The postbuckling analysis is based on an Marguerre-type energy method. The failure load of laminates is calculated by the maximum strain failure criterion based on the in-plane strains. Design variables are individual layer thicknesses with specified fiber orientations. Optimization with discrete valued design is achieved by introducing additional penalty terms to the regular pseudoobjective function of sequential unconstrained minimization technique. The proposed optimization technique is applied to the design of rectangular laminates with various aspect ratios loaded by axial compressive loads.

Shin, Dong KU↗

Demonstration of the Application of Composite Load Spectra (CLS) and Probabilistic Structural Analysis (PSAM) Codes to SSME Heat Exchanger Turnaround Vane

This report describes a probabilistic structural analysis performed to determine the probabilistic structural response under fluctuating random pressure loads for the Space Shuttle Main Engine (SSME) turnaround vane. It uses a newly developed frequency and distance dependent correlation model that has features to model the decay phenomena along the flow and across the flow with the capability to introduce a phase delay. The analytical results are compared using two computer codes SAFER (Spectral Analysis of Finite Element Responses) and NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) and with experimentally observed strain gage data. The computer code NESSUS with an interface to a sub set of Composite Load Spectra (CLS) code is used for the probabilistic analysis. A Fatigue code was used to calculate fatigue damage due to the random pressure excitation. The random variables modeled include engine system primitive variables that influence the operating conditions, convection velocity coefficient, stress concentration factor, structural damping, and thickness of the inner and outer vanes. The need for an appropriate correlation model in addition to magnitude of the PSD is emphasized. The study demonstrates that correlation characteristics even under random pressure loads are capable of causing resonance like effects for some modes. The study identifies the important variables that contribute to structural alternate stress response and drive the fatigue damage for the new design. Since the alternate stress for the new redesign is less than the endurance limit for the material, the damage due high cycle fatigue is negligible.

Rajagopal, Kadambi R.↗

Isolating Added Mass Load Components of CPAS Main Clusters

The current simulation for the Capsule Parachute Assembly System (CPAS) lacks fidelity in representing added mass for the 116 ft Do ringsail Main parachute. The availability of 3-D models of inflating Main canopies allowed for better estimation the enclosed air volume as a function of time. This was combined with trajectory state information to estimate the components making up measured axial loads. A proof-of-concept for an alternate simulation algorithm was developed based on enclosed volume as the primary independent variable rather than drag area growth. Databases of volume growth and parachute drag area vs. volume were developed for several flight tests. Other state information was read directly from test data, rather than numerically propagated. The resulting simulated peak loads were close in timing and magnitude to the measured loads data. However, results are very sensitive to data curve fitting and may not be suitable for Monte Carlo simulations. It was assumed that apparent mass was either negligible or a small fraction of enclosed mass, with little difference in results.

Ray, Eric S.↗

Simultaneous control and optimization for elastic systems

Studies are conducted to determine the dynamic response of beams and plates to loads which are extreme within a certain class of admissible loads. Two approaches to this problem are suggested. In approach one, Pontryagin's maximality principle is regarded as an additional constraint. The optimality of design is then determined by standard numerical techniques. The "adjoint variable approach' to sensitivity of structural design is applied for a given inhomogeneous term. The inhomogeneous term is an extremal element of admissible load vectors, which constitute a closed subspace of a Sobolev space. Again, the maximality principle is invoked. While only beam and plate theory problems are used as examples, generalizations are easy to perceive.

Komkov, V.↗

Twelve-Month Prostate-Specific Antigen Values and Perineural Invasion as Strong Independent Prognostic Variables of Long-Term Biochemical Outcome After Prostate Seed Brachytherapy

Purpose: To determine whether post-treatment prostate-specific antigen (ptPSA) values at 12 months and other clinical parameters predict long-term PSA relapse-free survival (PRFS) following prostate seed brachytherapy. Methods and Materials: Records of 204 hormone-naieve patients with localized adenocarcinoma of the prostate treated at St. Mary's Regional Medical Center in Reno, NV, and at Carson Tahoe Regional Medical Center in Carson City, NV, between 1998 and 2003, using I-125 or Pd-103 seed brachytherapy, were retrospectively analyzed. Treatment planning was done using a preplanned, modified peripheral loading technique. A total of 185 of 204 patients had PSA records at 12 months after implant. Variables included were age, initial pretreatment PSA, Gleason score, T stage, National Comprehensive Cancer Network (NCCN) risk group (RG), perineural invasion (PNI), external beam boost, dose, and ptPSA levels at 12 months with cutpoints at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml. Results: Median follow-up was 80 months, and median age was 69 years. The numbers of patients stratified by NCCN low, intermediate, and high RG were 110:65:10, respectively. Monotherapy and boost prescription doses were 145 Gy and 110 Gy for I-125, and 125 Gy and 100 Gy for Pd-103 seeds, respectively. The median dose (D90) was 95.4% of the prescribed dose. The 5-year PRFS at the 12-months ptPSA levels of {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml were 98.5%, 85.7%, 61.5%, and 22.2%, respectively. The 10-year PRFS at the 12-months ptPSA levels of {<=}1 and 1.01 to 2.00 ng/ml were 90.5% and 85.7%, respectively. In multivariate analysis, both ptPSA and PNI were significant independent predictors of PRFS. Hazard ratios (HR) for ptPSA levels at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml at 12 months were 1, 4.96, 27.57, and 65.10, respectively. PNI had an HR of 6.1 (p = 0.009). Conclusions: Presence of PNI and ptPSA values at 12 months are strong prognostic variables for long-term PRFS after definitive prostate brachytherapy seed implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ICL: The Image Composition Language

The Image Composition Language (ICL) provides a convenient way for programmers of interactive graphics application programs to define how the video look-up table of a raster display system is to be loaded. The ICL allows one or several images stored in the frame buffer to be combined in a variety of ways. The ICL treats these images as variables, and provides arithematic, relational, and conditional operators to combine the images, scalar variables, and constants in image composition expressions. The objective of ICL is to provide programmers with a simple way to compose images, to relieve the tedium usually associated with loading the video look-up table to obtain desired results.

Foley, James D.↗

Stochastic Simulation Tool for Aerospace Structural Analysis

Stochastic simulation refers to incorporating the effects of design tolerances and uncertainties into the design analysis model and then determining their influence on the design. A high-level evaluation of one such stochastic simulation tool, the MSC.Robust Design tool by MSC.Software Corporation, has been conducted. This stochastic simulation tool provides structural analysts with a tool to interrogate their structural design based on their mathematical description of the design problem using finite element analysis methods. This tool leverages the analyst's prior investment in finite element model development of a particular design. The original finite element model is treated as the baseline structural analysis model for the stochastic simulations that are to be performed. A Monte Carlo approach is used by MSC.Robust Design to determine the effects of scatter in design input variables on response output parameters. The tool was not designed to provide a probabilistic assessment, but to assist engineers in understanding cause and effect. It is driven by a graphical-user interface and retains the engineer-in-the-loop strategy for design evaluation and improvement. The application problem for the evaluation is chosen to be a two-dimensional shell finite element model of a Space Shuttle wing leading-edge panel under re-entry aerodynamic loading. MSC.Robust Design adds value to the analysis effort by rapidly being able to identify design input variables whose variability causes the most influence in response output parameters.

Knight, Norman F.↗

Modeling without categorical variables : a mixed-integer nonlinear program for the optimization of thermal insulation systems.

Optimal design applications are often modeled by using categorical variables to express discrete design decisions, such as material types. A disadvantage of using categorical variables is the lack of continuous relaxations, which precludes the use of modern integer programming techniques. We show how to express categorical variables with standard integer modeling techniques, and we illustrate this approach on a load-bearing thermal insulation system. The system consists of a number of insulators of different materials and intercepts that minimize the heat flow from a hot surface to a cold surface. Our new model allows us to employ black-box modeling languages and solvers and illustrates the interplay between integer and nonlinear modeling techniques. We present numerical experience that illustrates the advantage of the standard integer model.

97 MATHEMATICS AND COMPUTING↗

Modeling the mechanical properties of ultra-thin polymer films [Structural modeling of films of atomic scale thickness]

A modeling method to extract the mechanical properties of ultra-thin films (10–100 nm thick) from experimental data generated by indentation of freestanding circular films using a spherical indenter is presented. The relationship between the mechanical properties of the film and experimental parameters including load, and deflection are discussed in the context of a constitutive material model, test variables, and analytical approaches. As a result, elastic and plastic regimes are identified by comparison of finite element simulation and experimental data.

36 MATERIALS SCIENCE↗

Rotor and wake aerodynamic analysis of the Hybrid-Lambda concept - an offshore low-specific-rating rotor concept

The low-specific-rating rotor concept Hybrid-Lambda introduces a blade design with nonuniform distribution of design variables (design tip speed ratio and axial induction) along the blade span to alleviate loads of the outboard section in strong winds. In this paper, we validate aerodynamic design calculations, which were carried out with the blade element momentum theory by comparing the results to free vortex wake investigations (FVW). Furthermore, we investigate the wake behaviour with FVW and large-eddy simulations. The results show good agreements between the blade element momentum theory and FVW for integrated rotor quantities (power and thrust). Small deviations are present when the gradients of axial induction along the span are large. The wake of the Hybrid-Lambda Rotor shows advantages in the near-wake region (up to 4 diameters [D] downstream), especially in the outer wake annulus and in low turbulence scenarios. For further downstream positions, the wake is comparable to that of the reference turbine.

17 WIND ENERGY↗

Output Current Estimation and Control in Primary Side LCC Secondary Side Series Compensated Wireless Power Transfer System without Secondary Side Sensors

The estimation (and control) of the output variables is often challenging for wireless power transfer (WPT) systems. This paper presents a secondary side sensor-less closed loop estimation technique to estimate the output current in a primary side LCC and secondary side series compensated WPT system. Using information of primary side variables, the proposed estimation can estimate the output current over a wide range of load current variations. Results are presented to verify the efficacy of the proposed estimation.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)↗

Control and Coordination of Frequency Responsive Residential Water Heaters

Demand-side frequency control can complement traditional generator controls to maintain the stability of large electric systems in the face of rising uncertainty and variability associated with renewable energy resources. This paper presents a hierarchical frequency-based load control strategy that uses a supervisor to flexibly adjust control gains that a population of end-use loads respond to in a decentralized manner to help meet the NERC BAL-003-1 frequency response standard at both the area level and interconnection level. The load model is calibrated and used to model populations of frequency-responsive water heaters in a PowerWorld simulation of the U.S. Western Interconnection (WECC). The proposed design is implemented and demonstrated on physical water heaters in a laboratory setting. A significant fraction of the required frequency response in the WECC could be supplied by electric water heaters alone at penetration levels of less than 15%, while contributing to NERC requirements at the interconnection and area levels.

Williams, Tess L.↗

SULFATE SOLUBILITY LIMIT VERIFICATION FOR DWPF SLUDGE BATCH 7B

The objective of this study was to determine a sulfate solubility limit in glass for Sludge Batch 7b (SB7b). The SB7b composition projection provided by Savannah River Remediation (SRR) on May 25, 2011 was used as the basis for formulating glass compositions to determine the sulfate limit. Additions of Na{sub 2}O to the projected sludge composition were made by the Savannah River National Laboratory (SRNL) due to uncertainty in the final concentration of Na{sub 2}O for SB7b, which is dependent on washing effectiveness and the potential need to add NaOH to ensure an acceptable projected operating window. Additions of 4, 6, and 8 wt % Na{sub 2}O were made to the nominal May 25, 2011 composition projection. An updated SB7b composition projection was received from SRR on August 4, 2011. Due to compositional similarities, no additional experimental work using the August 4, 2011 compositions was considered to be necessary for this study. Both Frit 418 and Frit 702 were included in this study. The targeted sulfate (SO{sub 4}{sup 2-}) concentrations of the study glasses were selected within the range of 0.6 to 0.9 wt % in glass. A total of 52 glass compositions were selected based on the compositional variables of Na{sub 2}O addition, Actinide Removal Process (ARP) stream addition, waste loading, frit composition, and sulfate concentration. The glasses were batched, melted, and characterized following SRNL procedures. Visual observations were recorded for each glass after it cooled and used as in indicator of sulfur retention. Representative samples of each of the glasses fabricated were subjected to chemical analysis to determine whether the targeted compositions were met, as well as to determine the quantity of sulfate that was retained after melting. In general, the measured composition data showed that there were only minor issues in meeting the targeted compositions for the study glasses, and the measured sulfate concentrations for each study glass were within 10% of the targeted values. The results for the SB7b glasses fabricated with Frit 418 showed an apparent trend of increasing sulfate retention with increasing Na{sub 2}O additions to the 5/25/11 sludge projection. This trend appears contradictory to other recent studies of sulfate retention in Defense Waste Processing Facility (DWPF) type glasses. Additional apparent contradictions to this trend were found in the data collected in the present study. Overall, the results for the SB7b sulfate study glasses with Frit 418 and the 5/25/11 projection with Na{sub 2}O additions showed that subtle changes in this complex glass composition impacted the degree of sulfate retention. These results do however provide confidence that a 0.6 wt % sulfate limit in glass is warranted for Frit 418 with the SB7b compositions evaluated in this study. The results for the SB7b glasses fabricated with Frit 702 are consistent with those of the previous SB7a study in that Frit 702 allowed for higher sulfate retention as compared to Frit 418 for the same sludge compositions. It is recommended that the DWPF implement a sulfate concentration limit of 0.6 wt % in glass for SB7b processing with Frit 418. If a higher than projected sulfate concentration is measured when SB7b processing begins (i.e., if a sulfate concentration higher than 0.6 wt % becomes necessary to achieve targeted waste loadings), DWPF should consider a transition to Frit 702. The sulfate limit could likely be raised to 0.8 wt % by transitioning to this frit. However, if DWPF considers transitioning from Frit 418 to Frit 702, additional glasses should be fabricated to confirm this higher limit due to the issues with incorrect B{sub 2}O{sub 3} concentrations for some of the glasses made with Frit 702 in this study. There are several factors other than sulfate retention that must also be carefully considered prior to changing frit compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a Sulfate Solubility Limit Greater Than 0.65 Weight Percent in Sludge Batch 10 Glasses

Previous laboratory-scale crucible testing with batch chemicals confirmed that the sulfate (SO 4 2- ) limit for Sludge Batch 10 (SB10) was 0.65 weight percent (wt.%) in glass. This limit signifies that 0.65 wt.% SO 4 2- can be retained in the glass without the formation of a sulfate phase. The Defense Waste Processing Facility imposes this constraint in the Material Tracking Program. Based on preliminary calculations to support the Material Tracking Program, it was anticipated that transfer volumes of the monosodium titanate/sludge solids (MST/SS) stream from the Salt Waste Processing Facility (SWPF) may need to be reduced to maintain projected sulfate concentrations below 0.65 wt.% in glass. Savannah River Mission Completion requested that the Savannah River National Laboratory perform additional sulfate testing to determine whether a sulfate solubility limit greater than 0.65 wt.% is feasible for SB10, which could allow for higher transfer volumes of the MST/SS stream. This report documents the results of the testing at higher sulfate concentrations for the glass composition region defined by the most recent SB10 projection (November 2022) and Frits 473 and 625. Frit 473 was recommended for SB10 and Frit 625 was used during SB9 processing and the SB9 to SB10 transition. A total of twenty-one glass compositions were developed based on the expected compositional variables, which include sludge-only (SO) and coupled processing with the SWPF, waste loading (WL), and frit composition. The target sulfate concentrations were varied from 0.65-0.85 wt.% at 32 and 40% WL. Each glass was prepared from reagent grade chemicals and melted at 1150 °C. Visual observations were used to confirm the presence of a sulfate salt phase on the cooled glass surfaces. Representative samples of each glass were submitted for chemical composition analysis by inductively coupled plasma-optical emission spectroscopy and Cs analysis by inductively coupled plasma-mass spectrometry. Overall the majority of mean measured values are consistent with the target values for each major oxide of interest with less than 5% error. The percent errors for the measured SO 4 2- concentrations are generally less than 10%, which is comparable with previous sulfate solubility study measurements and acceptable. Only the SO glasses based on Frit 625 formed a sulfate phase at a 0.80 wt.% SO 4 2- target concentration at both 32 and 40% WL. The remainder of the glasses did not form a sulfate layer. Due to the formation of the sulfate phase, the limit is conservatively set at 0.70 wt.% based on the measured sulfate concentrations of 0.71 wt.% and 0.75 wt.% for these two glasses. None of the SO or coupled operation glasses based on Frit 473 formed a sulfate salt phase, which supports a sulfate limit of 0.80 wt.%. The following SO 4 2- concentration limits are recommended during SO and coupled SB10 processing: (1) 0.70 wt.% during processing with Frit 625, and (2) 0.80 wt.% during processing with Frit 473.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Closure Cesium Removal Ion Exchange Column CST Characterization: SRNL-STI-2024-00072 (Rev.0) pdf

Savannah River Mission Completion (SRMC) recently suspended operation of the Tank Closure Cesium Removal (TCCR) system which utilized an ion exchange (IX) process to remove radioactive cesium from waste supernate. During the demonstration phase, a total of three batches of Tank 10H dissolved salt waste were processed through the original TCCR columns. Subsequently, dissolved salt waste from Tank 9H was processed through TCCR in a phase referred to as TCCR 1A with four new IX columns. All eight columns have now been moved to Interim Safe Storage (ISS). For each batch processed through the TCCR IX columns, SRNL performed a number of analyses on surface and variable depth samples as well as batch equilibrium contact tests (BECT) to determine equilibrium loadings of Cs on the crystalline silicotitanate (CST) IX media. The BECTs were performed by lowering “teabags” containing ~0.1 g of CST each into the tank for a period of at least 10 days. The teabags were then retrieved and sent to SRNL for digestion and analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗