Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Experimental high gradient testing of a 17.1 GHz photonic band-gap accelerator structure

We report the design, fabrication and high gradient testing of a 17.1 GHz Photonic Band Gap accelerator structure. Photonic band-gap (PBG) structures are promising candidates for electron accelerators capable of high-gradient operation because they have the inherent damping of high order modes required to avoid beam breakup instabilities. The 17.1 GHz PBG structure tested was a single cell structure composed of a triangular array of round copper rods of radius 1.45 mm spaced by 8.05 mm. The test assembly consisted of the test PBG cell located between conventional (pillbox) input and output cells, with input power of up to 4 MW from a klystron supplied via a TM01 mode launcher. Breakdown at high gradient was observed by diagnostics including reflected power, downstream and upstream current monitors and visible light emission. The testing procedure was first benchmarked with a conventional disc-loaded waveguide structure, which reached a gradient of 87 MV/m at a breakdown probability of 1.19 × 10^-1 per pulse per meter. The PBG structure was tested with 100 ns pulses at power levels of less than 90 MV/m in order to limit the surface temperature rise to 120 K. The PBG structure reached up to 89 MV/m at a breakdown probability of 1.09×10^-1 per pulse per meter. These test results show that a PBG structure can simultaneously operate at high gradients and low breakdown probability, while also providing wakefield damping.

43 PARTICLE ACCELERATORS↗

Zero Degree Line Mo Target Thermal Test Results and Analysis

Target testing at 35 and 42 MeV was completed on January 14, 2015. At 35 MeV the current was varied from 177 to 375 μA with helium mass flow rate varied from 45 up to 101 g/s. At 42 MeV only one current, 170 mA, was tested because of accelerator performance limitations. The target design for this test, and the subsequent production tests, is largely unchanged from the earlier design for ANL beam tests at lower energy and higher current, comprised of 25 Mo disks 1 mm thick spaced 0.5 mm apart for helium coolant flow gaps. Disks are 12 mm diameter, with expected beam size 6 mm FWHM. Because the target, particularly the window, was designed for lower energy and higher current, the intercepted beam (beam heating) was much less during these tests. Therefore, the thermal stress and, more importantly, reduction in material strength resulting from high temperature, was not a limiting concern. The intended result of the thermal test is to measure heat transfer as a function of helium mass flow rate. Heat transfer coefficient was determined by the measurement of temperature at the center of the first 8 Mo disks while varying helium flow rate and beam current. The performance was then compared to predictive tools: Heat transfer correlations in the literature and finite element analysis using ANSYS

42 ENGINEERING↗

Van de Graaff Irradiation of Materials

Through irradiations using our 3 MeV Van de Graaf accelerator, Argonne is testing the radiation stability of components of equipment that are being used to dispense molybdenum solutions for use as feeds to 99m Tc generators and in the 99m Tc generators themselves. Components have been irradiated by both a direct electron beam and photons generated from a tungsten convertor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TM 6: Fractional Arc Test - beam through MLC & girder

On April 18 2018, the CBETA project achieved technical milestone 6, “Fractional Arc Test: beam through the Main Linac Cryomodule and prototype girder ”, which is also a major funding milestone. For this test the electron beam was accelerated to a final energy of 42 MeV in the Main Linac Cryomodule (MLC), before being passed through the first splitter beam line S-1 and through the first permanent magnet arc girder (PMA). The MLC contains six superconducting accelerating cavities; for this test only five of the six were powered due to a temporary fault in cavity number 5.

43 PARTICLE ACCELERATORS↗

Test Results of a High-Gradient 2.856-GHz Negative Harmonic Accelerating Waveguide

We report the high-gradient tests results of a novel traveling wave accelerating structure for β=0.3 based on a novel approach of operating at the first negative spatial harmonic. Accelerating gradients of 50 MV/m and peak electric fields of 160 MV/m were achieved in a single structure consisting of 15 coupled cells during tests at the advanced photon source. This work was performed by RadiaBeam, in collaboration with the Argonne National Laboratory, as a part of a Research and Development Program for the development of an ultrahigh-gradient linear accelerator, the Advanced Compact Carbon Ion Linac, for hadron therapy.

42 ENGINEERING↗

Stress Testing of Organic Light- Emitting Diode Panels and Luminaires

This report builds on previous DOE efforts with OLED technology by updating information on a previously benchmarked OLED product (the Chalina luminaire from Acuity Brands) and provides new benchmarks on the performance of Brite 2 and Brite Amber OLED panels from OLEDWorks. During the tests described here, samples of these devices were subjected to continuous operation in stress tests at elevated ambient temperature environments of 35°C or 45°C. In addition, samples were also operated continuously at room temperature in a room temperature operational life test (RTOL). One goal of this study was to investigate whether these test conditions can accelerate failure of OLED panels, either through panel shorting or an open circuit in the panel. These stress tests are shown to provide meaningful acceleration of OLED failure modes, and an acceleration factor of 2.6 was calculated at 45°C for some test conditions. In addition, changes in the photometric properties of the emitted light (e.g., luminous flux and chromaticity maintenance) was also evaluated for insights into the long-term stability of these products compared to earlier generations. Because OLEDs are a lighting system, electrical testing was also performed on the panel-driver pairs to provide insights into the impact of the driver on long-term panel performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-E-T-360: End-To-End Dosimetric Testing of a Versa HD Linear Accelerator with the Agility Head Modeled in Pinnacle3

Purpose: The Versa HD incorporates a variety of upgrades, primarily including the Agility head. The distinct dosimetric properties of the head from its predecessors combined with flattening-filter-free (FFF) beams require a new investigation of modeling in planning systems and verification of modeling accuracy. Methods: A model was created in Pinnacle{sup 3} v9.8 with commissioned beam data. Leaf transmission was modeled as <0.5% with maximum leaf speed of 3 cm/s. Photon spectra were tuned for FFF beams, for which profiles were modeled with arbitrary profiles rather than with cones. For verification, a variety of plans with varied parameters were devised, and point dose measurements were compared to calculated values. A phantom of several plastic water and Styrofoam slabs was scanned and imported into Pinnacle{sup 3}. Beams of different field sizes, SSD, wedges, and gantry angles were created. All available photon energies (6 MV, 10 MV, 18 MV, 6 FFF, 10 FFF) as well four clinical electron energies (6, 9, 12, and 15 MeV) were investigated. The plans were verified at a calculation point (8 cm deep for photons, variable for electrons) by measurement with a PTW Semiflex ionization chamber. In addition, IMRT testing was performed with three standard plans (step and shoot IMRT, small and large field VMAT plans). The plans were delivered on the Delta4 IMRT QA phantom (ScandiDos, Uppsala, Sweden). Results: Homogeneous point dose measurement agreed within 2% for all photon and electron beams. Open field photon measurements along the central axis at 100 cm SSD passed within 1%. Gamma passing rates were >99.5% for all plans with a 3%/3mm tolerance criteria. The IMRT QA results for the first 23 patients yielded gamma passing rates of 97.4±2.3%. Conclusion: The end-to-end testing ensured confidence in the ability of Pinnacle{sup 3} to model photon and electron beams with the Agility head.

60 APPLIED LIFE SCIENCES↗

NOVEL METHODS FOR IN SITU HIGH DENSITY SURFACE CLEANING SCRUBBING OF ULTRAHIGH VAC LONG NARROW TUBES TO REDUCE SECONDARY ELECTRON YIELD AND OUT GASSING

This project developed new methods for cleaning the inside surfaces of very long, narrow vacuum tubes used in particle accelerators. Traditional cleaning approaches are expensive, slow, or difficult to implement in accelerator tunnels. We designed and tested a portable plasma discharge cleaning system that uses lower-cost microwave and magnetron technologies to reduce outgassing and secondary electron emission from stainless steel and copper surfaces. The system, called the Plasma Discharge Test System (PDTS), allows accelerator components to be scrubbed more efficiently, which can improve performance and reduce maintenance costs for research and industrial applications.

POOLE, JOE HENRY [PRESIDENT]↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

High-Power Amplifier Considerations for testing the LAMP RFQ and first DTL Cavity

As part of the LANSCE Accelerator Modernization Pro ject (LAMP), critical portions of the proposed accelerator will be tested as proof of concept and aid in planning the installation of LAMP at Los Alamos Neutron Science Cen ter. As part of this demonstration, the radio frequency quadrupole (RFQ) and the first drift-tube linac (DTL) cav ity will be tested with beam. For this purpose, high-power RF amplifiers are being designed to meet the testing de mands. This is a description of the requirements of these amplifiers and how the design is intended to meet them.

42 ENGINEERING↗

Characterizing the flux effect on the irradiation embrittlement of reactor pressure vessel steels using machine learning

In-service exposure to high-energy neutrons embrittles reactor pressure vessel (RPV) steels. An increase in the yield stress (Δσ y ) results in a corresponding increase in the brittle to ductile transition temperature (ΔT c ). Most existing models underpredict ΔT c at higher fluence following accelerated irradiations in test reactors. High fluence, up to 10 20 n/cm 2 in some cases, will be reached over extended RPV vessel operation of 80 years, or more, at low service flux. Embrittlement has been extensively studied in accelerated, higher flux test reaction irradiations. However, the use of test reactor data naturally raises the question of flux effects. Here, this study used a machine learning approach trained on a set of hardening data, covering a wide range of flux, fluence, and steel compositions to determine the interactive effects of both irradiation and material variables on Δσ y . The analysis included machine learning-based cross-plots of the variable dependence of Δσ y for six core steels (i.e., CM6, LC, LD, LG, LH, and LI), with controlled differences in their Cu and Ni contents. A primary objective is to evaluate an effective to actual fluence (Φt e /Φt) ratio, as a function of flux, fluence, and steel composition. This is information critical to properly use intermediate flux-high fluence data in calibrating a low flux-high fluence embrittlement model. The predicted Φt e /Φt is reasonably consistent with estimates previously derived from a physics-based solute recombination trap model.

36 MATERIALS SCIENCE↗

Post-irradiation Examinations of High Burnup PWR Rods

The High Burnup Spent Fuel Data Project (herein referred to as the “project”), sponsored by the US Department of Energy (DOE) Office of Nuclear Energy (NE), is focused on experimentally evaluating the effects of long-term storage and transportation on high burnup (HBU) (defined as >45 gigawatt days per metric ton uranium) pressurized water reactor (PWR) spent nuclear fuel (SNF) [1]. To support this project, in the fall of 2017, an instrumented bolted-lid cask (project cask) at the North Anna reactor site was loaded with intact, HBU PWR fuel assemblies (project assemblies) having four different kinds of cladding and will be reopened in approximately 10-years for inspection. To support pre- and post-storage SNF rod characterization, 25 “sister rods” that are similar to the rods being stored in the project cask were extracted from seven different fuel assemblies at the North Anna nuclear power plant for post-irradiation examination (PIE).The sister rod testing program has multiple objectives, including: 1) Baseline testing to provide essential information on the physical condition and properties of the cladding and the fuel in the cladding prior to the loading, drying, and long-term dry storage process (analogous to an experiment control group). Similar tests are expected to be performed at the end of the 10-year storage period on rods extracted from the cask to identify any changes in the properties of the fuel rods that may have occurred during the dry storage period; and 2) Tests to provide material property and physical data using accelerated separate effects tests (SETs) and small-scale tests (SSTs) to explore a wide range of conditions that may occur for other dry storage systems and/or while the fuel is being transported after aging.Testing will be focused on understanding overall SNF rod strength and durability, and be comprised of both composite fuel and defueled clad testing with a focus on measuring cladding material and mechanical properties. Nondestructive testing is currently underway and plans are being updated to support the initial set of destructive tests that are expected to begin by early 2018. While the data generated can be used for multiple purposes, a primary goal of the sister rod PIE data and associated measured mechanical properties are expected to support existing fuel storage licensing and relicensing activities by addressing identified knowledge gaps, and enhance the technical bases for post-storage transportation, handling, and consolidation activities [1]. This paper presents results obtained from the sister rod testing to date, and describes some of the planned measurements, equipment, and procedures that will be implemented for the initial set of destructive examinations.

Montgomery, Rose↗

Post-irradiation Examinations of High Burnup PWR Rods - 18456

The High Burnup Spent Fuel Data Project (herein referred to as the 'project'), sponsored by the US Department of Energy (DOE) Office of Nuclear Energy (NE), is focused on experimentally evaluating the effects of long-term storage and transportation on high burnup (HBU) (defined as >45 gigawatt days per metric ton uranium) pressurized water reactor (PWR) spent nuclear fuel (SNF) [1]. To support this project, in the fall of 2017, an instrumented bolted-lid cask (project cask) at the North Anna reactor site was loaded with intact, HBU PWR fuel assemblies (project assemblies) having four different kinds of cladding and will be reopened in approximately 10-years for inspection. To support pre- and post-storage SNF rod characterization, 25 'sister rods' that are similar to the rods being stored in the project cask were extracted from seven different fuel assemblies at the North Anna nuclear power plant for post-irradiation examination (PIE). The sister rod testing program has multiple objectives, including: 1) Baseline testing to provide essential information on the physical condition and properties of the cladding and the fuel in the cladding prior to the loading, drying, and long-term dry storage process (analogous to an experiment control group). Similar tests are expected to be performed at the end of the 10-year storage period on rods extracted from the cask to identify any changes in the properties of the fuel rods that may have occurred during the dry storage period; and 2) Tests to provide material property and physical data using accelerated separate effects tests (SETs) and small-scale tests (SSTs) to explore a wide range of conditions that may occur for other dry storage systems and/or while the fuel is being transported after aging. Testing will be focused on understanding overall SNF rod strength and durability, and be comprised of both composite fuel and defueled clad testing with a focus on measuring cladding material and mechanical properties. Nondestructive testing is currently underway and plans are being updated to support the initial set of destructive tests that are expected to begin by early 2018. While the data generated can be used for multiple purposes, a primary goal of the sister rod PIE data and associated measured mechanical properties are expected to support existing fuel storage licensing and relicensing activities by addressing identified knowledge gaps, and enhance the technical bases for post-storage transportation, handling, and consolidation activities [1]. This paper presents results obtained from the sister rod testing to date, and describes some of the planned measurements, equipment, and procedures that will be implemented for the initial set of destructive examinations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status of the new SNS injector and external antenna ion source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW required by the planned Proton Power Upgrade (PPU) and Second Target Station (STS) projects. In early 2018 we plan to replace the entire 2.5 MeV injector configuration which includes the ion source, the Low Energy Beam Transport (LEBT) and the Radio Frequency Quadrupole accelerator (RFQ) with one which is currently being tested on a research accelerator called the Beam Test Facility (BTF) located at the SNS facility. This report first provides a description of the new injector: the ion source and the cage enclosure, the new LEBT support structure and the new RFQ. Since fall of 2016, this system has been tested extensively with regard to output beam current, beam persistence, emittance and energy. The results of these experiments employing both internal and external antenna ion sources will be summarized here showing the system to be capable of supporting SNS 1.4 MW operations with a significant margin as well as potentially meeting facility upgrade requirements. This represents a significant performance upgrade over the current SNS front end system with the compromised RFQ and will replace that system in early 2018.

Welton, Robert F.↗

SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

60 APPLIED LIFE SCIENCES↗

Novel Concepts for High Gradient Acceleration (Final Technical Report)

We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.

43 PARTICLE ACCELERATORS↗

Comparison of FAST Experiments to BISON Simulations

The Fission Accelerated Steady-State Test (FAST) experiments utilize the effects of scaling to accelerate the burnup experienced by the fuel. This experimental technique offers a unique opportunity to evaluate the effects of scaling on fuel and cladding material modelling. Currently, models used in the BISON fuel performance code for metallic fuel performance are calibrated for EBR-II conditions and geometries. Comparing BISON simulations to FAST experimental data will allow for the identification of shortcomings in the models for conditions outside the EBR-II paradigm. FAST experiments have been performed on U-Zr and U-10Mo fuel types with HT9 cladding. Initial comparisons of simulated cladding strains to experimental results show that the BISON simulations consistently overpredict cladding strain in the fuel region but underpredict the cladding strain in the plenum region. This indicates potential issues with the simulation of swelling and gas pressure at smaller geometries. Further comparison with fission gas release measurements is planned as data becomes available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗