Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Precise and Fast Computation of the Gravitational Field of a General Finite Body and Its Application to the Gravitational Study of Asteroid Eros

In order to obtain the gravitational field of a general finite body inside its Brillouin sphere, we developed a new method to compute the field accurately. First, the body is assumed to consist of some layers in a certain spherical polar coordinate system and the volume mass density of each layer is expanded as a Maclaurin series of the radial coordinate. Second, the line integral with respect to the radial coordinate is analytically evaluated in a closed form. Third, the resulting surface integrals are numerically integrated by the split quadrature method using the double exponential rule. Finally, the associated gravitational acceleration vector is obtained by numerically differentiating the numerically integrated potential. Numerical experiments confirmed that the new method is capable of computing the gravitational field independently of the location of the evaluation point, namely whether inside, on the surface of, or outside the body. It can also provide sufficiently precise field values, say of 14–15 digits for the potential and of 9–10 digits for the acceleration. Furthermore, its computational efficiency is better than that of the polyhedron approximation. This is because the computational error of the new method decreases much faster than that of the polyhedron models when the number of required transcendental function calls increases. As an application, we obtained the gravitational field of 433 Eros from its shape model expressed as the 24 × 24 spherical harmonic expansion by assuming homogeneity of the object.

79 ASTRONOMY AND ASTROPHYSICS↗

A polyvalent harmonic coil testing method for small-aperture magnets

A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETERMINATION OF HLW GLASS MELT RATE USING X-RAY COMPUTED TOMOGRAPHY

The purpose of the high-level waste (HLW) glass melt rate study is two-fold: (1) to gain a better understanding of the impact of feed chemistry on melt rate through bench-scale testing, and (2) to develop a predictive tool for melt rate in support of the on-going frit development efforts for the Defense Waste Processing Facility (DWPF). In particular, the focus is on predicting relative melt rates, not the absolute melt rates, of various HLW glass formulations solely based on feed chemistry, i.e., the chemistry of both waste and glass-forming frit for DWPF. Critical to the successful melt rate modeling is the accurate determination of the melting rates of various HLW glass formulations. The baseline procedure being used at the Savannah River National Laboratory (SRNL) is to; (1) heat a 4 inch-diameter stainless steel beaker containing a mixture of dried sludge and frit in a furnace for a preset period of time, (2) section the cooled beaker along its diameter, and (3) measure the average glass height across the sectioned face using a ruler. As illustrated in Figure 1-1, the glass height is measured for each of the 16 horizontal segments up to the red lines where relatively large-sized bubbles begin to appear. The linear melt rate (LMR) is determined as the average of all 16 glass height readings divided by the time during which the sample was kept in the furnace. This 'visual' method has proved useful in identifying melting accelerants such as alkalis and sulfate and further ranking the relative melt rates of candidate frits for a given sludge batch. However, one of the inherent technical difficulties of this method is to determine the glass height in the presence of numerous gas bubbles of varying sizes, which is prevalent especially for the higher-waste-loading glasses. That is, how the red lines are drawn in Figure 1-1 can be subjective and, therefore, may influence the resulting melt rates significantly. For example, if the red lines are drawn too low, a significant amount of glassy material interspersed among the gas bubbles will be excluded, thus underestimating the melt rate. Likewise, if they are drawn too high, many large voids will be counted as glass, thus overestimating the melt rate. As will be shown later in this report, there is also no guarantee that a given distribution of glass and gas bubbles along a particular sectioned plane will always be representative of the entire sample volume. Poor reproducibility seen in some LMR data may be related to these difficulties of the visual method. In addition, further improvement of the existing melt rate model requires that the overall impact of feed chemistry on melt rate be reflected on measured data at a greater quantitative resolution on a more consistent basis than the visual method can provide. An alternate method being pursued is X-ray computed tomography (CT). It involves X-ray scanning of glass samples, performing CT on the 2-D X-ray images to build 3-D volumetric data, and adaptive segmentation analysis of CT results to not only identify but quantify the distinct regions within each sample based on material density and morphologies. The main advantage of this new method is that it can determine the relative local density of the material remaining in the beaker after the heat treatment regardless of its morphological conditions by selectively excluding all the voids greater than a given volumetric pixel (voxel) size, thus eliminating much of the subjectivity involved in the visual method. As a result, the melt rate data obtained from CT scan will give quantitative descriptions not only on the fully-melted glass, but partially-melted and unmelted feed materials. Therefore, the CT data are presumed to be more reflective of the actual melt rate trends in continuously-fed melters than the visual data. In order to test the applicability of X-ray CT scan to the HLW glass melt rate study, several new series of HLW simulant/frit mixtures were melted in the Melt Rate Furnace (MRF) and the contents of each cooled but un-sectioned beaker were CT scanned and analyzed. For comparison purposes, a cross-sectional X-ray image of each sample was used to estimate the melt rate using the visual method. In order to see the impact of feed chemistry on melt rate more clearly, a total of ten frit-only glasses (i.e., no waste) were also made, CT scanned and analyzed. In addition, two historical glass series which were previously sectioned were re-joined and CT scanned; the results were then compared to the visual data obtained earlier. All the work performed on these historical samples will be documented separately in another report. This report describes the methodologies used to interpret and apply the results of X-ray CT scans to the HLW melt rate study and further highlights some of the key results on the compositional dependence of melt rate and the cross-comparison of the visual and CT results.

36 MATERIALS SCIENCE↗

UltraSciencenet: High- Performance Network Research Test-Bed

The high-performance networking requirements for next generation large-scale applications belong to two broad classes: (a) high bandwidths, typically multiples of 10Gbps, to support bulk data transfers, and (b) stable bandwidths, typically at much lower bandwidths, to support computational steering, remote visualization, and remote control of instrumentation. Current Internet technologies, however, are severely limited in meeting these demands because such bulk bandwidths are available only in the backbone, and stable control channels are hard to realize over shared connections. The UltraScience Net (USN) facilitates the development of such technologies by providing dynamic, cross-country dedicated 10Gbps channels for large data transfers, and 150 Mbps channels for interactive and control operations. Contributions of the USN project are two-fold: (a) Infrastructure Technologies for Network Experimental Facility: USN developed and/or demonstrated a number of infrastructure technologies needed for a national-scale network experimental facility. Compared to Internet, USN's data-plane is different in that it can be partitioned into isolated layer-1 or layer-2 connections, and its control-plane is different in the ability of users and applications to setup and tear down channels as needed. Its design required several new components including a Virtual Private Network infrastructure, a bandwidth and channel scheduler, and a dynamic signaling daemon. The control-plane employs a centralized scheduler to compute the channel allocations and a signaling daemon to generate configuration signals to switches. In a nutshell, USN demonstrated the ability to build and operate a stable national-scale switched network. (b) Structured Network Research Experiments: A number of network research experiments have been conducted on USN that cannot be easily supported over existing network facilities, including test-beds and production networks. It settled an open matter by demonstrating that the performance of switched connections and Multiple Protocol Label Switching tunnels over routed networks are comparable. Furthermore, such connections can be easily peered, and the performance of the resultant hybrid connections is still comparable to the constituent pure connections. USN experiments demonstrated that Infiniband transport can be effectively extended to wide-area connections of thousands of miles, which opens up new opportunities for efficient bulk data transport. USN provided dedicated connections to Cray X1 supercomputer and helped diagnose TCP performance problems which might have been otherwise incorrectly attributed to traffic on shared connections. USN contributed to the development of transport methods for dedicated connections to other traffic. Recently, experiments were conducted to assess the performance of application acceleration devices that employ flow optimization and data compression methods to improve TCP performance.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-205: Monte Carlo Modeling of Ultrasound Probes for Real-Time Ultrasound Image-Guided Radiotherapy

Purpose: To quantify the effect of ultrasound (US) probe beam attenuation for radiation therapy delivered under real-time US image guidance by means of Monte Carlo (MC) simulations. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their CT images in the EGSnrc BEAMnrc and DOSXYZnrc codes. Due to the metal parts, the probes were scanned in a Tomotherapy machine with a 3.5 MV beam. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2–8.0 g/cm{sup 3}. Beam attenuation due to the probes was measured in a solid water phantom for a 6 MV and 15 MV 15x15 cm{sup 2} beam delivered on a Varian Trilogy linear accelerator. The dose was measured with the PTW-729 ionization chamber array at two depths and compared to MC simulations. The extreme case beam attenuation expected in robotic US image guided radiotherapy for probes in upright position was quantified by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities were 4.6 and 4.2 g/cm{sup 3} in the C5-2 and X6-1 probe, respectively. Gamma analysis of the simulated and measured doses revealed that over 98% of measurement points passed the 3%/3mm criteria for both probes and measurement depths. The extreme attenuation for probes in upright position was found to be 25% and 31% for the C5-2 and X6-1 probe, respectively, for both 6 and 15 MV beams at 10 cm depth. Conclusion: MC models of two US probes used for real-time image guidance during radiotherapy have been built. As a Result, radiotherapy treatment planning with the imaging probes in place can now be performed. J Schlosser is an employee of SoniTrack Systems, Inc. D Hristov has financial interest in SoniTrack Systems, Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix-Free High-Performance Saddle-Point Solvers for High-Order Problems in \(\boldsymbol{H}(\operatorname{\textbf{div}})\)

Here, this work describes the development of matrix-free GPU-accelerated solvers for high-order finite element problems in H(div). The solvers are applicable to grad-div and Darcy problems in saddle-point formulation, and have applications in radiation diffusion and porous media flow problems, among others. Using the interpolation–histopolation basis, efficient matrix-free preconditioners can be constructed for the (1, 1)-block and Schur complement of the block system. With these approximations, block-preconditioned MINRES converges in a number of iterations that is independent of the mesh size and polynomial degree. The approximate Schur complement takes the form of an M-matrix graph Laplacian and therefore can be well-preconditioned by highly scalable algebraic multigrid methods. High-performance GPU-accelerated algorithms for all components of the solution algorithm are developed, discussed, and benchmarked. Numerical results are presented on a number of challenging test cases, including the “crooked pipe” grad-div problem, the SPE10 reservoir modeling benchmark problem, and a nonlinear radiation diffusion test case.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo simulation of Touschek effect.

We present a Monte Carlo method implementation in the code elegant for simulating Touschek scattering effects in a linac beam. The local scattering rate and the distribution of scattered electrons can be obtained from the code either for a Gaussian-distributed beam or for a general beam whose distribution function is given. In addition, scattered electrons can be tracked through the beam line and the local beam-loss rate and beam halo information recorded.

43 PARTICLE ACCELERATORS↗

THE FIRST FOCUSED HARD X-RAY IMAGES OF THE SUN WITH NuSTAR

We present results from the the first campaign of dedicated solar observations undertaken by the Nuclear Spectroscopic Telescope ARray ( NuSTAR ) hard X-ray (HXR) telescope. Designed as an astrophysics mission, NuSTAR nonetheless has the capability of directly imaging the Sun at HXR energies (>3 keV) with an increase in sensitivity of at least two magnitude compared to current non-focusing telescopes. In this paper we describe the scientific areas where NuSTAR will make major improvements on existing solar measurements. We report on the techniques used to observe the Sun with NuSTAR , their limitations and complications, and the procedures developed to optimize solar data quality derived from our experience with the initial solar observations. These first observations are briefly described, including the measurement of the Fe K-shell lines in a decaying X-class flare, HXR emission from high in the solar corona, and full-disk HXR images of the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning and Validation of the First Monte Carlo Based Dose Calculation Algorithm Commercial Treatment Planning System in Mexico

This work presents the beam data commissioning and dose calculation validation of the first Monte Carlo (MC) based treatment planning system (TPS) installed in Mexico. According to the manufacturer specifications, the beam data commissioning needed for this model includes: several in-air and water profiles, depth dose curves, head-scatter factors and output factors (6x6, 12x12, 18x18, 24x24, 42x42, 60x60, 80x80 and 100x100 mm{sup 2}). Radiographic and radiochromic films, diode and ionization chambers were used for data acquisition. MC dose calculations in a water phantom were used to validate the MC simulations using comparisons with measured data. Gamma index criteria 2%/2 mm were used to evaluate the accuracy of MC calculations. MC calculated data show an excellent agreement for field sizes from 18x18 to 100x100 mm{sup 2}. Gamma analysis shows that in average, 95% and 100% of the data passes the gamma index criteria for these fields, respectively. For smaller fields (12x12 and 6x6 mm{sup 2}) only 92% of the data meet the criteria. Total scatter factors show a good agreement (<2.6%) between MC calculated and measured data, except for the smaller fields (12x12 and 6x6 mm{sup 2}) that show a error of 4.7%. MC dose calculations are accurate and precise for clinical treatment planning up to a field size of 18x18 mm{sup 2}. Special care must be taken for smaller fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-456: Development of An EPID-Based Output Measurement and Dosimetric Verification Tool for Electron Beam Therapy

Purpose: To develop an efficient and robust method for output and absolute dosimetric measurements of electron beam therapy by using a high spatialresolution and high frame-rate amorphous silicon flat-panel electronic portal imaging device (EPID). Methods: A previously-established EPID dosimetry system was extended to measure the output factors of electron beams of various sizes and their planar dose distributions at reference depths. Specific EPID responses to different electron energies were derived from Monte Carlo (MC) simulations to de-convolve the EPID raw images to the incident electron fluence map. To reconstruct the 2D water-based dose distribution map at reference depths for different energies, the fluence map was further convolved with a MC simulated pencil beam kernel. Different energies of 6, 9, 12, 16, and 20 MeV from a Varian C-series linac were tested. Standard square fields ranging from 2×2 to 15×15 cm{sup 2} were measured and validated against film/ion chamber measurements. Small fields of different patient cases with irregular cutout shapes were also tested. Results: The EPIDmeasured output factors for 2×2, 3×3, 6×6, and 10×10 cm{sup 2} fields with all electron energies agree with the film/ion chamber data within 2.7%. The average discrepancy between EPID and film/ion chamber measurements was 1.4%. The differences for the three patient cases were 0.1%, 2.1%, and 1.6%. Deliveries with different monitor units were tested and the results exhibited good linearity. Measurements with different dose rate showed that the dose rate dependence was less than 1%. Using the proposed method, 2D absolute dose maps were created from the EPID raw images and the results were consistent with film measurements. Conclusion: The efficient data readout and portability of the newly developed EPID system provides an efficient and accurate solution for electron beam therapy. It addresses an important unmet clinical need for a fast and reliable small field output factor measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Mechanism of Peptide Agonist Binding in CXCR4 Chemokine Receptor

Chemokine receptors are key G-protein-coupled receptors (GPCRs) that control cell migration in immune system responses, development of cardiovascular and central nervous systems, and numerous diseases. In particular, the CXCR4 chemokine receptor promotes metastasis, tumor growth and angiogenesis in cancers. CXCR4 is also used as one of the two co-receptors for T-tropic HIV-1 entry into host cells. Therefore, CXCR4 serves as an important therapeutic target for treating cancers and HIV infection. Apart from the CXCL12 endogenous peptide agonist, previous studies suggested that the first 17 amino acids of CXCL12 are sufficient to activate CXCR4. Two 17-residue peptides with positions 1–4 mutated to RSVM and ASLW functioned as super and partial agonists of CXCR4, respectively. However, the mechanism of peptide agonist binding in CXCR4 remains unclear. Here, we have investigated this mechanism through all-atom simulations using a novel Peptide Gaussian accelerated molecular dynamics (Pep-GaMD) method. The Pep-GaMD simulations have allowed us to explore representative binding conformations of each peptide and identify critical low-energy states of CXCR4 activated by the super versus partial peptide agonists. Our simulations have provided important mechanistic insights into peptide agonist binding in CXCR4, which are expected to facilitate rational design of new peptide modulators of CXCR4 and other chemokine receptors.

59 BASIC BIOLOGICAL SCIENCES↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Bunch Profiling Using a Rotating Mask

The current method for measuring profiles of proton bunches in accelerators is severely lacking. One must dedicate a great deal of time and expensive equipment to achieve meaningful results. A new method to complete this task uses a rotating mask with slots of three different orientations to collect this data. By scanning over the beam in three different directions, a complete profile for each bunch is built in just seconds, compared to the hours necessary for the previous method. This design was successfully tested using synchrotron radiation emitted by SPEAR3. The profile of the beam was measured in each of the three desired directions. Due to scheduled beam maintenance, only one set of data was completed and more are necessary to solve any remaining issues. The data collected was processed and all of the RMS sizes along the major and minor axes, as well as the tilt of the beam ellipse were measured.

43 PARTICLE ACCELERATORS↗

Efficient Isobar Suppression by Photodetachment in a RF Quadrupole Ion Cooler

A highly efficient method for suppressing isobar contaminants in negative radioactive ion beams by photodetachment is demonstrated. A laser beam having the appropriate photon energy is used to selectively neutralize the contaminant if the electron affinity of the contaminant is lower than the electron affinity of the desired radioactive ions. The photodetachment efficiency can be dramatically increased when the laser-ion interaction is made inside a radio frequency quadrupole ion beam cooler where the ion residence time can be a few milliseconds. In off-line experiments with ion beams of stable isotopes, more than 99.9% suppression of S{sup -} and O{sup -} ions by photodetachment has been obtained. These ions would be the contaminants of desired beams of Cl{sup -} and F{sup -}, respectively. Under similar conditions no reduction in Cl{sup -} and F{sup -} ions was observed. The off-line results demonstrate the potential of this technique for on-line purification of a number of interesting radioactive beams and possible applications in accelerator mass spectrometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-235: Monte Carlo Analysis of the Dose Enhancement in the Scalp of Patients Due to Titanium Plate Backscatter During Post-Operative Radiotherapy

Purpose: To quantify the clinically observed dose enhancement adjacent to cranial titanium fixation plates during post-operative radiotherapy. Methods: Irradiation of a titanium burr hole cover was simulated using Monte Carlo code MCNPX for a 6 MV photon spectrum to investigate backscatter dose enhancement due to increased production of secondary electrons within the titanium plate. The simulated plate was placed 3 mm deep in a water phantom, and dose deposition was tallied for 0.2 mm thick cells adjacent to the entrance and exit sides of the plate. These results were compared to a simulation excluding the presence of the titanium to calculate relative dose enhancement on the entrance and exit sides of the plate. To verify simulated results, two titanium burr hole covers (Synthes, Inc. and Biomet, Inc.) were irradiated with 6 MV photons in a solid water phantom containing GafChromic MD-55 film. The phantom was irradiated on a Varian 21EX linear accelerator at multiple gantry angles (0–180 degrees) to analyze the angular dependence of the backscattered radiation. Relative dose enhancement was quantified using computer software. Results: Monte Carlo simulations indicate a relative difference of 26.4% and 7.1% on the entrance and exit sides of the plate respectively. Film dosimetry results using a similar geometry indicate a relative difference of 13% and -10% on the entrance and exit sides of the plate respectively. Relative dose enhancement on the entrance side of the plate decreased with increasing gantry angle from 0 to 180 degrees. Conclusion: Film and simulation results demonstrate an increase in dose to structures immediately adjacent to cranial titanium fixation plates. Increased beam obliquity has shown to alleviate dose enhancement to some extent. These results are consistent with clinically observed effects.

60 APPLIED LIFE SCIENCES↗

SU-E-T-670: Radiotherapy Vault Shielding Evaluation Method for a Flattening Filter-Free (FFF) Linac-Practical Considerations and Recommendations

Purpose: To date, there isn’t formal approach for flattening filter-free (FFF) linac vault shielding evaluation, thus, we propose an extension to NCRP#151 to accommodate the recent large number of FFF linac installations.Methods and Materials: We extended the approach in NCRP#151 to design two Truebeam vaults in our new cancer center for hypofractionated treatments. Monte Carlo calculations have characterized primary, scattered, leakage and neutron radiations from FFF-modes. These calculations have shown that: a) FFF primary beam is softer on the central-axis compared to flattening filtered (FF), b) the lateral dose profile is peaked on the central axis and less integral target current is required to generate the same tumor dose with the FF beam. Thus, the TVLs for FFF mode are smaller than those of the FF mode and the scatter functions of the FF mode (NCRP#151) may not be appropriate for FFF-mode, c) the neutron source strength and fluence for 18X-FFF is smaller than 18X-FF, but it is not of a concern here, no 18X-FFF-mode is available on the linac under investigation. Results: These barrier thickness are smaller (12% reduction on the average) than those computed for conventional FF mode with same realistic primary workload since, the primary TVLs used here are smaller and the WL is smaller than the conventional (almost half reduced), keeping the TADR in tolerance. Conclusions: A comprehensive method for shielding barrier calculations based on dedicated data for FFF-mode linacs is highly desired. Meanwhile, we provide an extension to NCRP#151 to accommodate the shielding design of such installations. It is also shown that if a vault is already designed for IMRT/VMAT and SABR hypofractionated treatments with FFF-mode linac, the vault can also be used for a FFF mode linac replacement, leaving some leeway for slightly higher workload on the FFF linac.

61 RADIATION PROTECTION AND DOSIMETRY↗