Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A balancing domain decomposition method by constraints for advection-diffusion problems

The balancing domain decomposition methods by constraints are extended to solving nonsymmetric, positive definite linear systems resulting from the finite element discretization of advection-diffusion equations. A pre-conditioned GMRES iteration is used to solve a Schur complement system of equations for the subdomain interface variables. In the preconditioning step of each iteration, a partially sub-assembled finite element problem is solved. A convergence rate estimate for the GMRES iteration is established, under the condition that the diameters of subdomains are small enough. It is independent of the number of subdomains and grows only slowly with the subdomain problem size. Numerical experiments for several two-dimensional advection-diffusion problems illustrate the fast convergence of the proposed algorithm.

97 MATHEMATICS AND COMPUTING↗

NV Energy Solar Integration Study: Cycling and Movements of Conventional Generators for Balancing Services

With an increasing penetration level of solar power in the southern Nevada system, the impact of solar on system operations needs to be carefully studied from various perspectives. Qualitatively, it is expected that the balancing requirements to compensate for solar power variability will be larger in magnitude; meanwhile, generators providing load following and regulation services will be moved up or down more frequently. One of the most important tasks is to quantitatively evaluate the cycling and movements of conventional generators with solar power at different penetration levels. This study is focused on developing effective methodologies for this goal and providing a basis for evaluating the wear and tear of the conventional generators

14 SOLAR ENERGY↗

Variable Renewable Generation can Provide Balancing Control to the Electric Power System (Fact Sheet)

As wind and solar plants become more common in the electric power system, they may be called on to provide grid support services to help maintain system reliability. For example, through the use of inertial response, primary frequency response, and automatic generation control (also called secondary frequency response), wind power can provide assistance in balancing the generation and load on the system. These active power (i.e., real power) control services have the potential to assist the electric power system in times of disturbances and during normal conditions while also potentially providing economic value to consumers and variable renewable generation owners. This one-page, two-sided fact sheet discusses the grid-friendly support and benefits renewables can provide to the electric power system.

14 SOLAR ENERGY↗

Tank 12H Acidic Chemical Cleaning Sample Analysis And Material Balance

A process of Bulk Oxalic Acid (BOA) chemical cleaning was performed for Tank 12H during June and July of 2013 to remove all or a portion of the approximately 4400 gallon sludge heel. Three strikes of oxalic acid (nominally 4 wt% or 2 wt%) were used at 55°C and tank volumes of 96- to 140-thousand gallons. This report details the sample analysis of a scrape sample taken prior to BOA cleaning and dip samples taken during BOA cleaning. It also documents a rudimentary material balance for the Tank 12H cleaning results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of Groundwater Recharge at Pahute Mesa using the Chloride Mass-Balance Method

Groundwater recharge on Pahute Mesa was estimated using the chloride mass-balance (CMB) method. This method relies on the conservative properties of chloride to trace its movement from the atmosphere as dry- and wet-deposition through the soil zone and ultimately to the saturated zone. Typically, the CMB method assumes no mixing of groundwater with different chloride concentrations; however, because groundwater is thought to flow into Pahute Mesa from valleys north of Pahute Mesa, groundwater flow rates (i.e., underflow) and chloride concentrations from Kawich Valley and Gold Flat were carefully considered. Precipitation was measured with bulk and tipping-bucket precipitation gauges installed for this study at six sites on Pahute Mesa. These data, along with historical precipitation amounts from gauges on Pahute Mesa and estimates from the PRISM model, were evaluated to estimate mean annual precipitation. Chloride deposition from the atmosphere was estimated by analyzing quarterly samples of wet- and dry-deposition for chloride in the bulk gauges and evaluating chloride wet-deposition amounts measured at other locations by the National Atmospheric Deposition Program. Mean chloride concentrations in groundwater were estimated using data from the UGTA Geochemistry Database, data from other reports, and data from samples collected from emplacement boreholes for this study. Calculations were conducted assuming both no underflow and underflow from Kawich Valley and Gold Flat. Model results estimate recharge to be 30 mm/yr with a standard deviation of 18 mm/yr on Pahute Mesa, for elevations >1800 m amsl. These estimates assume Pahute Mesa recharge mixes completely with underflow from Kawich Valley and Gold Flat. The model assumes that precipitation, chloride concentration in bulk deposition, underflow and its chloride concentration, have been constant over the length of time of recharge.

54 ENVIRONMENTAL SCIENCES↗

Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems Using a Bottom-Up Approach and Installer Survey

This report presents results from the first U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs—often referred to as “business process” or “soft” costs—for residential and commercial photovoltaic (PV) systems. Annual expenditure and labor-hour-productivity data are analyzed to benchmark 2010 soft costs related to the DOE priority areas of (1) customer acquisition; (2) permitting, inspection, and interconnection; (3) installation labor; and (4) installer labor for arranging third-party financing. Annual expenditure and labor-hour data were collected from 87 PV installers. After eliminating outliers, the survey sample consists of 75 installers, representing approximately 13% of all residential PV installations and 4% of all commercial installations added in 2010. Including assumed permitting fees, in 2010 the average soft costs benchmarked in this analysis total $1.50/W for residential systems (ranging from $0.66/W to $1.66/W between the 20th and 80th percentiles). For commercial systems, the median 2010 benchmarked soft costs (including assumed permitting fees) are $0.99/W for systems smaller than 250 kW (ranging from $0.51/W to $1.45/W between the 20th and 80th percentiles) and $0.25/W for systems larger than 250 kW (ranging from $0.17/W to $0.78/W between the 20th and 80th percentiles). Additional soft costs not benchmarked in the present analysis (e.g., installer profit, overhead, financing, and contracting) are significant and would add to these figures. The survey results provide a benchmark for measuring—and helping to accelerate—progress over the next decade toward achieving the DOE SunShot Initiative’s soft-cost-reduction targets. We conclude that the selected non-hardware business processes add considerable cost to U.S. PV systems, constituting 23% of residential PV system price, 17% of small commercial system price, and 5% of large commercial system price (in 2010). These processes present significant opportunities for further cost reductions and labor-productivity gains.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Non-Destructive Assay (NDA) Uncertainties Impact on Physical Inventory Difference (ID) and Material Balance Determination: Sources of Error, Precision/Accuracy, and ID/Propagation of Error (POV)

These are slides from a presentation made by a researcher from Los Alamos National Laboratory. The following topics are covered: sources of error for NDA gamma measurements, precision and accuracy are two important characteristics of measurements, four items processed in a material balance area during the inventory time period, inventory difference and propagation of variance, sum in quadrature, and overview of the ID/POV process.

36 MATERIALS SCIENCE↗

Request for Funding for the 2016 Air & Waste Management Association Visibility Conference on Atmospheric Optics:Aerosols, Visibility, and the Radiative Balance

This international conference will provide a technical forum on advances in the scientific understanding of the effects of aerosols on urban, regional, continental, and global-scale haze and the radiative balance. The conference will take a multipronged approach and address scientific topics (e.g., related to measurements, modeling, etc.) as well as regulatory and policy issues. There will be sessions on black and brown carbon, as recent research has shown the importance of these particles for radiative forcing. In addition, there will be sessions related to the synergistic and increasing concerns of the effects of atmospheric nitrogen and carbonaceous material on haze, climate change, and nitrogen deposition on ecosystems. Conference learning will be enhanced with a half day excursion and hikes in Grand Teton National Park and a Night Sky Program.

54 ENVIRONMENTAL SCIENCES↗

E-Area Low-Level Waste Facility Vadose Zone Model: Confirmation of Water Mass Balance for Subsidence Scenarios

In preparation for the next revision of the E-Area Low-Level Waste Facility (LLWF) Performance Assessment (PA), a mass balance model was developed in Microsoft Excel to confirm correct implementation of intact- and subsided-area infiltration profiles for the proposed closure cap in the PORFLOW vadose-zone model. The infiltration profiles are based on the results of Hydrologic Evaluation of Landfill Performance (HELP) model simulations for both intact and subsided cases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of harmonic balance capability for Charon

We report on the development of a frequency domain method of analysis in the Panzer foundation of Charon. We first present a harmonic balance approach for calculating the frequency-domain response (in its weak form) of a non-linear system of partial differential equations (PDEs). Our approach is anemable to adaptation of Charon's transient PDE models for frequency domain analysis. We make an observation that allows us to analyze either small-signal or large-signal responses with minimal specialization of the algorithm. We conclude by confirming our small- and large-signal analyses of a transient, linear Helmholtz equation by comparing its analytic solution to our results. We include figures from a sequence of non-linear perturbations of this system, showcasing the fact that, when the non-linearities are insignificant, the small- and large-signal analyses obtain similar solutions. On the other hand, we depict the inadequacy of a small-signal analysis to accurately capture the response in the presence of a large non-linearity, and underscore the requirement to employ a large-signal analysis for modelling highly non-linear systems.

97 MATHEMATICS AND COMPUTING↗

Army Net Zero. Water Balance and Roadmap Programmatic Summary

In 2011, the Department of the Army created the net zero initiative to advance the sustainability of the Army by managing natural resources with the goal of establishing net zero installations. The Net Zero concept is founded upon the idea of consuming natural resources responsibly based upon knowledge of long-term resource availability, creating a sustainable environment to support the installation’s long-term mission. The Army is pursuing net zero programs in energy, water, and waste. To kick off the net zero initiative, the Army selected installations to demonstrate the concept of net zero energy, water, and waste. This document is an overview of assessments performed at the eight net zero water installations. Each assessment included a water balance and a roadmap intended to provide pilot installations with a strategic approach to achieve net zero goals.

54 ENVIRONMENTAL SCIENCES↗

Where Have All of the Electrons Gone? Understanding the Role of Alternative Electron Flow and O 2 Reduction in Balancing Cellular Redox (Final Technical Report)

An informed understanding of the fundamentals of light-driven electron transfer reactions in photoautotrophic organisms is necessary to enable improved photosynthetic efficiencies for the production of renewable fuels and novel biomaterials. To obtain high photosynthetic yields, light energy must be efficiently coupled to the fixation of CO 2 . Sub-optimal environmental conditions and metabolic routing (caused by blocks in biosynthetic routes) can severely impact the conversion of light energy to biomass and lead to reactive oxygen production, which in turn can cause cellular damage and productivity losses. Hence, plants, algae, and photosynthetic bacteria have evolved a network of alternative outlets to sustain the flow of photosynthetically derived-electrons. Our research was focused on the nature and integration of these outlets. The data obtained in this project will inform efforts to rationally engineer crop plants and algae to improve photosynthetic yields by enhancing electron transfer reactions to CO 2 reduction and targeted biomass accumulation. A major project research thrust was focused on identifying and quantifying the flow of photosynthetic reductant through electron transfer circuits that result in the light-dependent reduction of O 2 . New energy management strategies were identified that are used when normal carbon assimilation pathways are compromised due to nutrient deprivation, and/or by a reduction in starch synthesis/carbon storage, all conditions resulting in highly reduced intracellular redox pools. The green alga Chlamydomonas reinhardtii, and likely many other algae, have multiple O 2 -reducing pathways that play critical roles in maintaining cellular metabolic balance and scavenging electrons that could potentially cause cellular damage, which in some instances leads to reduced photosynthetic yields but increased fitness. We explored the activities of three essential outlets associated with Chlamydomonas reinhardtii photosynthetic electron transport: (1) reduction of O 2 to H 2 O through Flavodiiron proteins (FLVs) and (2) Plastid Terminal Oxidases (PTOX), and (3) the synthesis of starch. Real-time measurements of O 2 exchange demonstrated that FLVs immediately engage during dark to light transitions, allowing electron transport when the CBBC is not fully activated. Under these conditions, we quantified, for the first time, maximal FLV activity and its overall capacity to direct photosynthetic electrons towards O 2 reduction. However, when starch synthesis is compromised, a greater proportion of electrons is directed toward O 2 reduction through the FLVs, while PTOX, which is sensitive to the PQ pool redox state, is activated. This suggests, that starch synthesis has an important role in priming/regulating CBBC and electron transport. We also identified a biological ‘switch’ in the green alga Chlamydomonas reinhardtii that reversibly restricts photosynthetic electron transport (PET) at the cytochrome b 6 f complex when reductant and ATP generated by PET are in excess of the capacity of carbon metabolism to utilize these products; we specifically show a restriction at this switch when sta6 mutant cells, which cannot synthesize starch, are limited for nitrogen (growth inhibition) and subjected to a dark to light transition. This restriction causes diminished electron flow to PSI, which prevents PSI photodamage, and the plastid alternative oxidase (PTOX) becomes fully activated, serving as an electron valve that dissipates excitation energy absorbed by PSII, thereby lessening PSII photoinhibition. Furthermore, illumination of the cells following the dark acclimation gradually diminishes the restriction at the switch. Future engineering of these switches may allow more effective electron transfer to lipid (biofuel) pathways and diminish the number of electrons “wasted” in the reduction of O 2 to water. Lastly, we explored metabolic routing of electrons during algal fermentation and discovered multiple novel pathways that are activated when the preferred anoxic routes are blocked. These provide valuable products (e.g. lactate, glycerol) that can be used in broad portfolio of biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗

Plant Water Profiler: A Water Balance and True Cost of Water Calculator for Manufacturing Plants

As the uncertainty of a sustained water supply, regulatory constraints, competition among end users, and public scrutiny increases, a growing number of manufacturing sectors are adapting to current and emerging water-related risks by optimizing productivity and reducing waste. As a step toward increasing water use efficiency and making informed business decisions, corporations must make an effort to understand and track their water demands, losses, and costs associated with each subsystem within their facilities. Manufacturers are often unaware of the “true cost of water” (i.e., the total costs associated with procurement, treatment, and consumption of water, and wastewater disposal), which reduces the visibility of the actual impact of water-saving measures. To help manufacturers account for water procurement and use in manufacturing operations, quantify the true cost of water, and identify potential areas for water and associated energy cost savings, an open access tool—Plant Water Profiler (PWP)—was developed. The tool is based on water mass balance analysis and has been adopted as the core analysis tool for plant water use assessments, Water In-Plant Training (Water INPLT), as part of the US Department of Energy’s Better Plants program. During three pilot INPLTs conducted in 2019 at three manufacturing facilities, the PWP tool allowed users to understand water flows within the facilities and provided additional capabilities to analyze their water use. This paper describes the methodology behind the PWP tool and its implementation through pilot Water INPLT trainings delivered in three manufacturing facilities in the United States. The three case studies demonstrate opportunities to improve water efficiency and reduce associated costs and the challenges encountered in three different manufacturing sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Cr-Evaporation from Balance Of Plant Components By Utilizing Cost-Effective Alumina-Forming Austenitic Steels

A solid oxide fuel cell (SOFC) is a clean and efficient energy conversion device. The development of intermediate-temperature SOFCs has made it preferable to use metallic interconnects (MICs) to greatly reduce the cost and significantly increase the efficiency compared to ceramic interconnect materials. However, gaseous chromium species will evaporate from the chromium-containing layer formed on the surface of commonly used MICs and balance of plant (BoP) components. Volatile chromium species have been shown to form solid deposits which poison the cathodes of SOFCs, causing drastic cell performance degradation and thereby limiting commercialization. In order to alleviate the Cr poisoning and achieve long-term high performance of SOFC stacks, various Al 2 O 3 -forming austenitic (AFA) stainless steels applied at different temperatures are evaluated in this project. Based on our Phase I results (500 h operation), it is shown that on the AFAs, an alumina-based protective layer forms under high temperature that is invulnerable to water vapor effects and suppresses the diffusion of chromium and manganese which can prevent the generation of spinels on the alloy surface. Therefore, 310S, OC4 and OC5 at 800 °C and 625, OC11 and OC11LZ at 900 °C are selected to be tested in the Phase II long-term operation. From the results, we find that besides the lower Cr evaporation rates and better oxidation resistance of AFAs than benchmark alloys after short-term (500 h) operation, AFAs also possess the sturdy and compact alumina layer after a long-term operation (5000 h). A protective oxide layer is of great importance for the long-term high-temperature operation of structural materials. The high-temperature oxidation behavior of AFAs and commercial 310S and 625 alloys in Air + 10% H 2 O at 800 °C and 900 °C is systematically investigated. Severe breakaway oxidation and minor spallation are observed for the 310S and 625 after the long-term operation, while the AFAs show high oxidation resistance. It is found that the formation of a continuous alumina layer could greatly prevent the volatilization of chromium vapors. In addition, the corresponding evolving models are discussed. Chromium evaporation from BoP components in high-temperature environment could severely deteriorate the electrochemical performance of SOFC. Several methods were applied to evaluate the Cr evaporation rates of BoP after 500 h exposure at 800 °C to 900 °C in air with 10% H 2 O. An optimal method was designed to exclude the effect of silicon (Si) deposits from quartz tube and sodium (Na) deposits from the sodium carbonate on the oxidation process and the chemical interaction between Cr gaseous species and alumina tube which could provide further quantitative correlation of the evaporated Cr species quantities and degradation rates of SOFC. Based on the great performance of AFAs after long-term operation, AFAs are assembled with Anode-supported cells (ASC) to investigate the the Cr deposition of anode-supported cell under a constant current density of 0.5 A cm -2 at 800 °C with AFA alloys compared with commercial alloys. In addition, the anodic and cathodic processes are deconvoluted by distribution of relaxation times (DRT) method which are comprehensively discussed. It is found out that the voltage exhibited a slight decrease of 5.09 % and 1.54 % in the presence of OC11 and OC11LZA alloy, respectively. However, a considerable decrease of 22.14 % and 12.06 % was determined in the presence of 310S and 625 alloy, respectively. AFAs possessing the low-cost, low Cr evaporation rates and the high oxidation resistance will make it of great potential to replace the existing BoP components.

01 COAL, LIGNITE, AND PEAT↗

ANL Design Team Analysis: Transportable Modular Reactor by Balance of Plant Elimination

HolosGen LLC is developing “Holos-Quad” a transportable gas-cooled reactor, with integral load following power conversion systems equipping subcritical power modules (SPMs), fully comprised within standard transport containers. The design eliminates the Balance of Plant (BoP) and greatly simplifies the design layout. A closed-loop full Brayton gas thermodynamic cycle converts the fuel cartridges thermal energy into electricity. This ARPA-E project utilizes advanced reactor modeling tools and manufacturing-testing of a scaled SPM equipped with a surrogate fuel cartridge to eliminate the most significant technology gaps to accelerate commercialization. The Argonne Design Team contributes to the research by demonstrating feasibility of various aspects of the Holos-Quad design by performing high-fidelity neutronic modeling, and investigating various reactivity control systems. This work consists of two main tasks: evaluation of HolosGen’s design features and alternative options study for reactivity control.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IONEX Mass and Energy Balance for LAW TCO Unit and Ammonia/Air Dilution Skid

The objective of this calculation is to perform a mass and energy balance analysis of the LAW TCO unit, and Ammonia/Air Dilution piping systems. The analysis will verify as well as establish several design conditions. Offgas temperatures will be calculated to establish a system design temperature. Flow rates and pressures are calculated throughout to help with sizing equipment. Offgas composition and properties are established at each node along the system. The nodes are identified in the P&ID. Flow rates from the ammonia dilution skid are also calculated to determine the ammonia injection required for the performance of the SCR.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗