Cold cathode quadrupole mass spectrometer.
Cold cathode ion source /CCIS/ quadrupole mass spectrometer for ultrahigh residual gas analysis
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cold cathode ion source /CCIS/ quadrupole mass spectrometer for ultrahigh residual gas analysis
Plants sense positional changes relative to the gravity vector. To date, the signaling processes by which the perception of a gravistimulus is linked to the initiation of differential growth are poorly defined. We have investigated the role of inositol 1,4,5-trisphosphate (InsP(3)) in the gravitropic response of oat (Avena sativa) shoot pulvini. Within 15 s of gravistimulation, InsP(3) levels increased 3-fold over vertical controls in upper and lower pulvinus halves and fluctuated in both pulvinus halves over the first minutes. Between 10 and 30 min of gravistimulation, InsP(3) levels in the lower pulvinus half increased 3-fold over the upper. Changes in InsP(3) were confined to the pulvinus and were not detected in internodal tissue, highlighting the importance of the pulvinus for both graviperception and response. Inhibition of phospholipase C blocked the long-term increase in InsP(3), and reduced gravitropic bending by 65%. Short-term changes in InsP(3) were unimpaired by the inhibitor. Gravitropic bending of oat plants is inhibited at 4 degrees C; however, the plants retain the information of a positional change and respond at room temperature. Both short- and long-term changes in InsP(3) were present at 4 degrees C. We propose a role for InsP(3) in the establishment of tissue polarity during the gravitropic response of oat pulvini. InsP(3) may be involved in the retention of cold-perceived gravistimulation by providing positional information in the pulvini prior to the redistribution of auxin.
In the Antarctic cold desert, cryptoendolithic microorganisms live under the surface of porous sandstone rocks. During the austral summer, the environment of the near-surface rock layers colonized by organisms is characterized by two kinds of temperature oscillations, both occurring across the freezing point. Low-frequency (diurnal) and large-amplitude (up to about 20 degrees C) oscillations on the sunlit surface of rocks result in a daily freeze-thaw cycle. This is a result of the diurnal changes in the sun altitude and angle with respect to the rock surface. The biological effect of this oscillation is the regulation of the onset and cessation of metabolic activity. The high-frequency (few minutes) oscillations occur only under certain weather conditions (sunny days with light winds) and are superimposed on the low-frequency oscillations. They are caused by the cooling effect of wind gusts on rock surfaces that are much warmer than ambient air temperatures. High-frequency oscillations result in a rapid freeze-thaw cycle on the surface, which, however, does not reach the microbial zone. These high-frequency freeze-thaw oscillations are probably the cause of the abiotic nature of the rock surface. Both oscillations seem to have an effect on rock weathering.
Whole body heat production (HP) and heat loss (HL) were examined to determine if the free-running circadian rhythm in body temperature (Tb) results from coordinated changes in HP and HL rhythms in thermoneutrality (27 degrees C) as well as mild cold (17 degrees C). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of Tb and activity. Feeding was also measured. Rhythms of HP, HL, and conductance were tightly coupled with the circadian Tb rhythm at both ambient temperatures (TA). At 17 degrees C, increased HP compensated for higher HL at all phases of the Tb rhythm, resulting in only minor changes to Tb. Parallel compensatory changes of HP and HL were seen at all rhythm phases at both TA. Similar time courses of Tb, HP, and HL in their respective rhythms and the relative stability of Tb during both active and rest periods suggest action of the circadian timing system on Tb set point.
The Local Scale Observation Site (LSOS) is the smallest study site of the Cold LandProcesses Experiment (CLPX) and is located within the Fraser Meso-cell Study Area (MSA), near the Fraser Experimental Forest Headquarters Facility, in Fraser, CO USA.The 100-m x 100-m site consists of a small open field, a managed dense canopy and an open, mixed age canopy. Unlike the other components of the experiment, which focus on spatial distributions at relatively brief snapshots in time, measurements at the local scale site focused on the temporal domain.
The Atmospheric Infrared Sounder (AIRS) experiment, on NASA's Aqua spacecraft, uses a combination of infrared and microwave observations to retrieve cloud and surface properties, plus temperature and water vapor profiles comparable to radiosondes throughout the troposphere, for cloud cover up to 70%. The high spectral resolution of AIRS provides sensitivity to important information about the near-surface atmosphere and underlying surface. A preliminary analysis of AIRS temperature retrievals taken during January 2003 reveals extensive areas of superadiabatic lapse rates in the lowest kilometer of the atmosphere. These areas are found predominantly east of North America over the Gulf Stream, and, off East Asia over the Kuroshio Current. Accompanying the high lapse rates are low air temperatures, large sea-air temperature differences, and low relative humidities. Imagery from a Visible / Near Infrared instrument on the AIRS experiment shows accompanying clouds. These lines of evidence all point to shallow convection in the bottom layer of a cold air mass overlying warm water, with overturning driven by heat flow from ocean to atmosphere. An examination of operational radiosondes at six coastal stations in Japan shows AIRS to be oversensitive to lower tropospheric lapse rates due to systematically warm near-surface air temperatures. The bias in near-surface air temperature is seen to be independent of sea surface temperature, however. AIRS is therefore sensitive to air-sea temperature difference, but with a warm atmospheric bias. A regression fit to radiosondes is used to correct AIRS near-surface retrieved temperatures, and thereby obtain an estimate of the true atmosphere-ocean thermal contrast in five subtropical regions across the north Pacific. Moving eastward, we show a systematic shift in this air-sea temperature differences toward more isothermal conditions. These results, while preliminary, have implications for our understanding of heat flow from ocean to atmosphere. We anticipate future improvements in the AIRS retrieval algorithm will lead to improved understanding of the exchange of sensible and latent heat from ocean to atmosphere, and more realistic near-surface lapse rates.
Today Mars is a cold, dry, desert planet. Liquid water is not stable on its surface. There are no lakes, seas, or oceans, and rain falls nowhere at no time during the year. Yet early in its history during the Noachian epoch, there is geological and mineralogical evidence that liquid water did indeed flow on its surface creating drainage systems, lakes, and possibly, seas and oceans. The implication is that early Mars had a different climate than it does today, one that was based on a thicker atmosphere with a more powerful greenhouse effect that was capable of producing an active hydrological cycle with rainfall, runoff, and evaporation. Since Mariner 9 began accumulating such evidence, researchers have been trying to understand what kind of a climate system could have created greenhouse conditions favorable for liquid water. Unfortunately, the problem is not yet solved.
To quantify the turbulent transport at gray zone length scales between 1 and 10 km the Lagrangian evolution of the CONSTRAIN cold air outbreak (CAO) case was simulated with seven large eddy models. The case is characterized by rather large latent and sensible heat fluxes, and a rapid deepening rate of the boundary layer. In some models the entrainment velocity exceeds 4 cm/s. A significant fraction of this growth is attributed to a strong longwave radiative cooling of the inversion layer. The evolution and the timing of the breakup of the stratocumulus cloud deck differ significantly among the models. Sensitivity experiments demonstrate that a decrease in the prescribed cloud droplet number concentration, and the inclusion of ice microphysics, both act to speed up the thinning of the stratocumulus by enhancing the production of precipitation. In all models the formation of mesoscale fluctuations is clearly evident in the cloud fields but also in the horizontal wind velocity. Resolved vertical fluxes remain important for scales up to 10 km. The simulation results show that the resolved vertical velocity variance gradually diminishes with a coarsening of the horizontal mesh, but the total vertical fluxes of heat, moisture, and momentum are only weakly affected. This is a promising result as it demonstrates the potential use of a mesh size dependent turbulent length scale for convective boundary layers at gray zone model resolutions.
Marine cold air outbreaks (CAOs) commonly form overcast cloud decks that transition into broken cloud fields downwind, dramatically altering the local radiation budget. In this study, we investigate the impact of frozen hydrometeors on these transitions. We focus on a CAO case in the NW Atlantic, the location of the multi-year flight campaign ACTIVATE (Aerosol Cloud meTeorology Interactions oVer the western ATlantic Experiment). We use MERRA-2 (Modern-Era Retrospective analysis for Research and Applications, version 2) reanalysis fields to drive large eddy simulations with mixed-phase two-moment microphysics in a Lagrangian framework. We find that transitions are triggered by substantial rain (rainwater paths >25 g m−2), and only simulations that allow for aerosol depletion result in sustained breakups, as observed. Using a range of diagnostic ice nucleating particle concentrations, Ninp, we find that increasing ice progressively accelerates transitions, thus abbreviating the overcast state. Ice particles affect the cloud-topped boundary layer evolution, primarily through riming-related processes prior to substantial rain, leading to (1) a reduction in cloud liquid water, (2) early consumption of cloud condensation nuclei, and (3) early and light precipitation cooling and moistening below cloud. We refer to these three effects collectively as “preconditioning by riming”. Greater boundary layer aerosol concentrations available as cloud condensation nuclei (CCN) delay the onset of substantial rain. However, cloud breakup and low CCN concentration final stages are found to be inevitable in this case, due, primarily, to liquid water path buildup. An ice-modulated cloud transition speed suggests the possibility of a negative cloud–climate feedback. To address prevailing uncertainties in the model representation of mixed-phase processes, the magnitude of ice formation and riming impacts and, thereby, the strength of an associated negative cloud–climate feedback process, requires further observational evaluation by targeting riming hot spots with in situ imaging probes that allow for both the characterization of ice particles and abundance of supercooled droplets.
Aluminum has been identified as a compound within regolith and is likely to become a core component of our infrastructure on the lunar surface as in-situ resource utilization (ISRU) capabilities are advanced Large-scale components, outfitting, and repairs of aluminum materials can be fabricated with robotic wire arc additive manufacturing (WAAM) in order to inhabit the moon’s surface long term WAAM is a high value process for lunar advanced manufacturing as it does not require special containment to reduce explosion hazards such as powder-based additive processes and feedstock The welding process of cold metal transfer (CMT) is a relatively new variation of gas metal arc welding (GMAW, also known as MIG) that relies on the detection of a short circuit in the welding process to control the deposition droplet action, resulting in lower heat input and splatter compared to conventional MIG welding The past year was spent developing the CMT-WAAM process for aluminum materials, tested specialty feedstock, tested within the high vacuum environment, and advanced the MSFC capability to perform complex toolpathing from solid models Upcoming and future work includes large depositions working towards material certification for multiple feedstocks, in-situ monitoring, work to use recycled materials for the AM feedstock, and the design and fabrication of a parabolic flight experiment payload.
Despite the recent recognition of -17 O-excess as a promising new tracer for hydrological processes, our knowledge of the control mechanisms underlying -17 O-excess in tropical regions remains limited. To understand how microphysical processes during tropical convection affect precipitation isotope ratios, particularly -17 O-excess, in Singapore, we collected precipitation samples at minute intervals from six rain events associated with cold surges during the Northeast Monsoon seasons and analyzed their triple oxygen isotopes. Our results show that precipitation δ -18 O decreases in the convective zones and then gradually increases in the stratiform zones, while d-excess exhibits an inverse trend. This correlation between δ -18 O and d-excess indicates that rain evaporation plays a crucial role in regulating precipitation isotopes. Moreover, the rain events with a higher upstream rainout amount have lower δ -18 O and higher -17 O-excess values, suggesting that precipitation δ -18 O and -17 O-excess likely reflect the integrated upstream convective activity. Microphysical processes associated with upstream convection, such as rain evaporation and vapor recycling, are potential mechanisms that increase -17 O-excess values along moisture transport pathways for a rain event, and hence, undermine the effectiveness of -17 O-excess as a tracer of moisture source humidity. Contrary to the negative correlation observed in monthly precipitation, there is generally a positive correlation between d-excess and -17 O-excess at the event scale. However, this correlation weakens as convective rain intensifies, suggesting that stronger convection can attenuate the positive correlation between d-excess and -17 O-excess. Therefore, it is crucial to consider how tropical convection alters -17 O-excess when utilizing this tracer to interpret atmospheric dynamics and hydrological processes.
Transformational melter technologies are being considered to support mission acceleration within the U.S. Department of Energy (DOE) complex. New glass formulations are required to take full advantage of the next generation melters, for example, the cold crucible induction melter (CCIM). The key advantage of CCIM technology over current reference technologies is its capability to provide higher processing temperatures, which can lead to an increased waste throughput rate by achieving higher waste loadings and by increasing the feed processing rate. Various waste compositions within the DOE complex were evaluated to determine their potential for successfully demonstrating the unique advantages of the CCIM technology. Glass formulations that satisfy a set of constraints for product quality and assumed CCIM processing conditions were developed for two Hanford waste streams, AZ-101 high-level waste (HLW) and AN-105 low-activity waste (LAW). Three glasses selected for AZ-101 HLW have waste loadings of 40, 42.5, and 45 wt%. The 45-wt% waste loading corresponds to a 22% increase from 37 wt%, which is the maximum expected waste loading based on the current reference formulation. One glass selected for AN-105 LAW has a waste loading of 31.3 wt% at 24 wt% Na2O in glass, which is a 14% increase from the current reference formulation maximum of 21 wt% Na2O. These four glasses are planned for scaled melter tests for initial demonstration of the CCIM technologies for Hanford wastes.
Numerical simulation results for the cold pressing of Armstrong CP-Ti Powders are presented. The computational model was implemented in the commercial finite element program ABAQUSTM. Several simulation cases were conducted for cylindrical samples with different friction coefficients and different compaction pressures, under both single-action and dual-action uniaxial pressing. Numerical simulation results for the density distribution are compared against experimental data in order to validate the computational model.
Wells in traditional hydrothermal reservoirs are used to extract heat and to dispose of cooled water. In the first case, high productivity (the ratio of production flow rate to the pressure differential required to produce that rate) to is preferred in order to maximize power generation, while minimizing the parasitic energy loss of pumping. In the second case, high injectivity (the ratio of injection flow rate to the pressure differential required to produce that rate) is preferred, in order to reduce pumping costs. In order to improve productivity or injectivity, cold water is sometimes injected into the reservoir in an attempt to cool and contract the surrounding rock matrix and thereby induce dilation and/or extension of existing fractures or to generate new fractures. Though the increases in permeability associated with these changes are likely localized, by improving connectivity to more extensive high-permeability fractures they can at least temporarily provide substantially improved productivity or injectivity.
In this study, an atmospheric river (AR) detection algorithm is developed to investigate the downstream modulation of the eastern North Pacific ARs by another weather extreme, known as the East Asian cold surge (EACS), in both reanalysis data and high-resolution global model simulations. It is shown that following the peak of an EACS, atmospheric disturbances of intermediate frequency (IF; 10 30 day period) are excited downstream. This leads to the formation of a persistent cyclonic circulation anomaly over the eastern North Pacific that dramatically enhances the AR occurrence probability and the surface precipitation over the western U.S. between 30 N and 50 N. A diagnosis of the local geopotential height tendency further confirms the essential role of IF disturbances in establishing the observed persistent anomaly. This downstream modulation effect is then examined in the two simulations of the National Center for Atmospheric Research Community Climate System Model version 4 with different horizontal resolutions (T85 and T341) for the same period (1979 2005). The connection between EACS and AR is much better captured by the T341 version of the model, mainly due to a better representation of the scale interaction and the characteristics of IF atmospheric disturbances in the higher-resolution model. The findings here suggest that faithful representations of scale interaction in a global model are critical for modeling and predicting the occurrences of hydrological extremes in the western U.S. and for understanding their potential future changes.
??National programs such as Home Performance with ENERGY STAR(R) and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made. Confirmation of successfully achieving 30% source energy savings over the pre-existing conditions was confirmed through energy modeling and comparison of the utility bills pre- and post- retrofit.
Here, the historical material culture produced by American Cold War nuclear weapons testing includes objects of scientific inquiry that can be generally categorized as being either ephemeral or enduring. Objects deemed to be ephemeral were of a less substantial nature, being impermanent and expendable in a nuclear test, while enduring objects were by nature more durable and long-lasting. Although all of these objects were ultimately subject to disappearance, the processes by which they were transformed, degraded, or destroyed prior to their disappearing differ. Drawing principally upon archaeological theory, this paper proposes a functional dichotomy for categorizing and studying the historical trajectories of nuclear weapons testing technoscience artifacts. In examining the transformation patterns of steel towers and concrete blockhouses in particular, it explores an associated loss of scientific method that accompanies a science object's disappearance.
Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.