Search NASA⌕ Search

SEARCH · Search NASA

Results for “Color Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

In-flight flow visualization using infrared imaging

A flight test investigation was conducted to evaluate infrared (IR) flow imaging techniques for boundary-layer flow visualization. The flight tests used a single-engine turboprop aircraft with a fiberglass-skinned natural laminar flow glove mounted on the left wing and an infrared imaging system to obtain flow visualization data. Data were compared to results obtained from other more conventional boundary-layer flow visualization methods and found to agree well. Test flights were conducted to determine the effect of test surface color on IR flow visualization results. In addition, flights were made during both night and daylight hours to assess the effect of solar radiation on the results. The investigation included an effort to visualize a vortex passing over the wing glove, but the tests provided only limited results.

Brandon, J. M.↗

Orbital docking system centerline color television camera system test

A series of tests was run to verify that the design of the centerline color television camera (CTVC) system is adequate optically for the STS-71 Space Shuttle Orbiter docking mission with the Mir space station. In each test, a mockup of the Mir consisting of hatch, docking mechanism, and docking target was positioned above the Johnson Space Center's full fuselage trainer, which simulated the Orbiter with a mockup of the external airlock and docking adapter. Test subjects viewed the docking target through the CTVC under 30 different lighting conditions and evaluated target resolution, field of view, light levels, light placement, and methods of target alignment. Test results indicate that the proposed design will provide adequate visibility through the centerline camera for a successful docking, even with a reasonable number of light failures. It is recommended that the flight deck crew have individual switching capability for docking lights to provide maximum shadow management and that centerline lights be retained to deal with light failures and user preferences. Procedures for light management should be developed and target alignment aids should be selected during simulated docking runs.

Mongan, Philip T.↗

A BRIEF DESCRIPTION OF THE SMALL-SCALE SAFETY TESTING SYSTEMS AT LAWRENCE LIVERMORE NATIONAL LABORATORY

Small-scale sensitivity testing is important for determining material response to various stimuli including impact, friction, and static spark. These tests, briefly described below, provide parameters for safety in handling. ERL Type 12 drop hammer equipment at LLNL, shown in Figure 1, was used to determine the impact sensitivity. The equipment includes a 2.5-kg drop weight, a striker (upper anvil, 2.5 kg for solid samples and 1.0 kg for liquid samples), a bottom anvil, a microphone sensor, and a peakmeter. For each drop, sample (35 mg for solid or 45 microliter for liquid) is placed on the bottom anvil surface and impacted by the drop weight from different heights. Signs of reactions upon impact are observed and recorded. These signs include noises, flashes or sparks, smoke, pressure, gas emissions, temperature rise due to exothermic reaction, color change of the sample, and changes to the anvil surface (noted by inspection). For solid samples, a 'GO' was defined as a microphone sensor (for noise detection) response of {ge} 1.3 V as measured by a peakmeter. The higher the DH{sub 50} values, the lower the impact sensitivity. The method used to calculate DH{sub 50} values is the 'up and down' or Bruceton method. PETN and RDX have impact sensitivities of 15 and 35 cm, respectively. TATB has impact sensitivity more than 177 cm. For liquid samples, a 'GO' was determined by the noise levels as measured by the peakmeter, appearance of flashes, temperature rise of the anvil, and visual inspection of the anvil surface. Two liquid samples TMETN and FEFO have impact sensitivities of 14 and 32 cm, respectively. Figure 2 shows a 'GO' event observed during the impact sensitivity test; flashes appeared as the drop weight impacted the sample. A BAM friction sensitivity test machine, as shown in Figure 3, was used to determine the frictional sensitivity. The system uses a fixed porcelain pin and a movable porcelain plate that executes a reciprocating motion. Weight affixed to a torsion arm allows for a variation in applied force between 0.5 kg to 36.0 kg. The relative measure of the frictional sensitivity of a material is based upon the smallest load (kg) at which reaction occurs for a 1-in-10 series of attempts. The lower the load values, the higher the frictional sensitivity. PETN has a frictional sensitivity of 6.4 kg. The static spark machine at LLNL is used to evaluate the electrostatic discharge hazards (human ESD) associated with the handling of explosives. The machine was custom-built almost 30 years ago and consists of a capacitor bank (up to 20,000 pF), a voltage meter, and a discharge circuit, as shown in Figure 4. An adjustable resistor up to 510 ohms (chosen to simulate human body) is wired to the discharge circuit. A 5-mg sample is placed in a Teflon washer sealed to a steel disc and covered with a Mylar tape. High static voltage (up to 10 kv) is applied and discharged to the sample. Evidence of reaction is judged from the condition of Mylar tape, smokes, and color change of the sample. Voltage, capacitance, and resistance can be adjusted to achieve the desired static energy. The results obtained are expressed as a zero in 10 or one-in-ten at a specific voltage and joules. One reaction in ten trials at {le} 0.25 joules is considered spark-sensitive. Primary explosives show reaction at 0.1 joule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate Analysis of the Change in Volume, Location, and Shape of Metastatic Cervical Lymph Nodes During Radiotherapy

Purpose: To establish a method for the accurate acquisition and analysis of the variations in tumor volume, location, and three-dimensional (3D) shape of tumors during radiotherapy in the era of image-guided radiotherapy. Methods and Materials: Finite element models of lymph nodes were developed based on computed tomography (CT) images taken before the start of treatment and every week during the treatment period. A surface geometry map with a volumetric scale was adopted and used for the analysis. Six metastatic cervical lymph nodes, 3.5 to 55.1 cm{sup 3} before treatment, in 6 patients with head and neck carcinomas were analyzed in this study. Three fiducial markers implanted in mouthpieces were used for the fusion of CT images. Changes in the location of the lymph nodes were measured on the basis of these fiducial markers. Results: The surface geometry maps showed convex regions in red and concave regions in blue to ensure that the characteristics of the 3D tumor geometries are simply understood visually. After the irradiation of 66 to 70 Gy in 2 Gy daily doses, the patterns of the colors had not changed significantly, and the maps before and during treatment were strongly correlated (average correlation coefficient was 0.808), suggesting that the tumors shrank uniformly, maintaining the original characteristics of the shapes in all 6 patients. The movement of the gravitational center of the lymph nodes during the treatment period was everywhere less than {+-}5 mm except in 1 patient, in whom the change reached nearly 10 mm. Conclusions: The surface geometry map was useful for an accurate evaluation of the changes in volume and 3D shapes of metastatic lymph nodes. The fusion of the initial and follow-up CT images based on fiducial markers enabled an analysis of changes in the location of the targets. Metastatic cervical lymph nodes in patients were suggested to decrease in size without significant changes in the 3D shape during radiotherapy. The movements of the gravitational center of the lymph nodes were almost all less than {+-}5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilizing remote sensing data for land use decisions for Indian lands in South Dakota.

Evaluation of photographic and thermal infrared imagery acquired at an altitude of 11,500 ft above ground level (in southwestern South Dakota) on Oct. 15, 1970, June 30, 1971, and Aug. 2, 1971, for use in mapping range sites and soils. A density slicing system was used to enhance film optical density differences associated with range sites and soils. The range site boundaries in native rangeland areas were found to be delineated best by a density slicing analysis of color infrared film obtained in August 1971. The range site maps produced by density slicing were superior to existing range inventory maps. The density slicing analysis of color infrared film from the August 1971 flight was best for locating soil boundaries in rangeland areas. To adequately map soils in rangeland areas, data based on density slicing used in conjunction with slope gradient information derived from stereoscopic analyses provided more detailed and accurate information than is presently available from range site and soil maps of the area.

Frazee, C. J.↗

Overview of mesocale research Doppler lidar activities

In evaluating the performance of the airborne Doppler lidar system, a large number of deficiencies or mistakes were identified in the original system and experiment plans. All of the known problems were addressed and corrected in the planning and engineering for the fall 1984/spring 1985 ADLS flight series. Thus, the most significant result of the data analysis was the input it has provided to the preparations for the new experiment. Attitude measurements are taken together with the streamlined operating procedures, color graphics real time displays of data, and better experiment design, the result is a second-generation system that is considerably better than the one used in 1981.

Fitzjarrald, D. E.↗

Geological analysis and evaluation of ERTS-A imagery for the state of New Mexico

The author has identified the following significant results. Coverage of approximately one-third of the test site had been received by January 31, 1973 and all of the images received were MSS products. Images recorded during the first two months of the ERTS-1 mission were of poor quality, owing largely to high ground reflectance. Later images were of better quality and MSS bands 5 and 7 have proven to be particularly useful. Features noted during visual inspection of 9 1/2 x 9 1/2 prints include major structural forms, vegetation patterns, drainage patterns, and outcrops of geologic formations having marked color contrasts. The Border Hills Structural Zone and the Y-O Structural Zone are prominently reflected in coverage of the Pecos Valley. A study of available maps and remote sensing material covering the Deming-Columbus area indicated that the limit of detection and the resolution of MSS products are not as good as those of aerial photographs, geologic maps, and manned satellite photographs. The limit of detection of high contrast features on MSS prints is approximately 1000 feet or 300 meters for linear features and about 18 acres for roughly circular areas.

Kottlowski, F. E.↗

Terrain Portrayal for Synthetic Vision Systems Head-Down Displays Evaluation Results

A critical component of SVS displays is the appropriate presentation of terrain to the pilot. At the time of this study, the relationship between the complexity of the terrain presentation and resulting enhancements of pilot SA and pilot performance had been largely undefined. The terrain portrayal for SVS head-down displays (TP-HDD) simulation examined the effects of two primary elements of terrain portrayal on the primary flight display (PFD): variations of digital elevation model (DEM) resolution and terrain texturing. Variations in DEM resolution ranged from sparsely spaced (30 arc-sec) to very closely spaced data (1 arc-sec). Variations in texture involved three primary methods: constant color, elevation-based generic, and photo-realistic, along with a secondary depth cue enhancer in the form of a fishnet grid overlay.

Hughes, Monica F.↗

THE CHANDRA COSMOS SURVEY. III. OPTICAL AND INFRARED IDENTIFICATION OF X-RAY POINT SOURCES

The Chandra COSMOS Survey (C-COSMOS) is a large, 1.8 Ms, Chandra program that has imaged the central 0.9 deg{sup 2} of the COSMOS field down to limiting depths of 1.9 Multiplication-Sign 10{sup -16} erg cm{sup -2} s{sup -1} in the soft (0.5-2 keV) band, 7.3 Multiplication-Sign 10{sup -16} erg cm{sup -2} s{sup -1} in the hard (2-10 keV) band, and 5.7 Multiplication-Sign 10{sup -16} erg cm{sup -2} s{sup -1} in the full (0.5-10 keV) band. In this paper we report the i, K, and 3.6 {mu}m identifications of the 1761 X-ray point sources. We use the likelihood ratio technique to derive the association of optical/infrared counterparts for 97% of the X-ray sources. For most of the remaining 3%, the presence of multiple counterparts or the faintness of the possible counterpart prevented a unique association. For only 10 X-ray sources we were not able to associate a counterpart, mostly due to the presence of a very bright field source close by. Only two sources are truly empty fields. The full catalog, including spectroscopic and photometric redshifts and classification described here in detail, is available online. Making use of the large number of X-ray sources, we update the 'classic locus' of active galactic nuclei (AGNs) defined 20 years ago in soft X-ray surveys and define a new locus containing 90% of the AGNs in the survey with full-band luminosity >10{sup 42} erg s{sup -1}. We present the linear fit between the total i-band magnitude and the X-ray flux in the soft and hard bands, drawn over two orders of magnitude in X-ray flux, obtained using the combined C-COSMOS and XMM-COSMOS samples. We focus on the X-ray to optical flux ratio (X/O) and we test its known correlation with redshift and luminosity, and a recently introduced anti-correlation with the concentration index (C). We find a strong anti-correlation (though the dispersion is of the order of 0.5 dex) between X/O computed in the hard band and C and that 90% of the obscured AGNs in the sample with morphological information live in galaxies with regular morphology (bulgy and disky/spiral), suggesting that secular processes govern a significant fraction of the black hole growth at X-ray luminosities of 10{sup 43}-10{sup 44.5} erg s{sup -1}. We also investigate the degree of obscuration of the sample using the hardness ratio, and we compare the X-ray color with the near-infrared to optical color.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated quantification of mitral valve regurgitation based on normalized centerline velocity distribution

Previous echocardiographic techniques for quantifying valvular regurgitation are limited by factors including uncertainties for orifice location and a hemispheric convergence assumption that often results in over- and underestimation of flow rate and regurgitant orifice area. Using computational fluid dynamics simulations, these factors were eliminated, allowing a more accurate assessment of regurgitation. A model was developed to allow automated quantification of regurgitant orifice diameter based on the centerline velocity data available from color M-mode echocardiography. The model, validated using in vitro unsteady flow data, demonstrated improved accuracy for orifice diameter (y=0.95x + 0.38, r=0.96) and volume (y=1.18x - 4.72, r=0.93).

NASA Program Biomedical Research and Countermeasur↗

Structural and optical properties of Sm{sup 3+}-doped borate glasses for luminescent applications

In this work, most interesting optical investigations are carried out with the glass composition (20 − x) CdCO{sub 3} + 15 Li{sub 2}CO{sub 3} + 15 Na{sub 2}CO{sub 3} + 50 H{sub 3}BO{sub 3} + xSm{sub 2}O{sub 3} (where x = 0.1, 0.5, 1.0, 3.0, 4.0 and 5.0 mol%) prepared with conservative melt-quenching technique. DSC verifies the annealing temperature and thermal stability of the prepared glass. X-ray diffraction technique is employed to inspect the amorphous structure of the glasses. FTIR technique helps to view the vibrational band positions of the host material. For optical studies, optical absorption and emission measurements are used. From the absorption spectra, Judd–Ofelt (JO) parameters (Ω{sub 2}, Ω{sub 4}, Ω{sub 6}), rms value of oscillator strength (δ{sub rms}), nephelauxetic parameter ( β-bar ), bonding parameter (δ) and optical band gaps are evaluated. Radiative properties such as radiative transition probabilities (A{sub T}), branching ratios (β{sub cal}, β{sub exp}) and stimulated emission cross section (σ{sub emi}) are calculated using JO theory. The higher stimulated emission cross section (14.39 × 10{sup −22} cm{sup 2}), optical gain (36.69 × 10{sup −25} cm{sup 2} s) indicate that 1.0 mol% of Sm{sup 3+}-doped borate glass would be a potential gain medium for solid state laser application at 603 nm. Color coordinates of the glasses located in the reddish-orange region could be useful for white light-emitting application.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Luminescence properties of Ce{sup 3+} and Tb{sup 3+} co-doped SiO{sub x}N{sub y} thin films: Prospects for color tunability in silicon-based hosts

In this work, the role of the nitrogen content, the annealing temperature, and the sample morphology on the luminescence properties of Ce{sup 3+} and Tb{sup 3+} co-doped SiO{sub x}N{sub y} thin films has been investigated. An increasing nitrogen atomic percentage has been incorporated in the host matrix by gradually replacing oxygen with nitrogen during fabrication while maintaining the Si content unaltered, obtaining a sequential variation in the film composition from nearly stoichiometric SiO{sub 2} to SiO{sub x}N{sub y}. The study of rare earth doped single layers has allowed us to identify the parameters that yield an optimum optical performance from Ce{sup 3+} and Tb{sup 3+} ions. Ce{sup 3+} ions proved to be highly sensitive to the annealing temperature and the nitrogen content, showing strong PL emission for relatively low nitrogen contents (from 0 to 20%) and moderate annealing temperatures (800–1000 °C) or under high temperature annealing (1180 °C). Tb{sup 3+} ions, on the other hand, displayed a mild dependence on those film parameters. Rare earth co-doping has also been investigated by comparing the luminescence properties of three different approaches: (i) a Ce{sup 3+} and Tb{sup 3+} co-doped SiO{sub x}N{sub y} single layer, (ii) a bilayer composed of two SiO{sub x}N{sub y} single layers doped with either Ce{sup 3+} or Tb{sup 3+} ions, and (iii) a multilayer composed of a series of either Tb{sup 3+} or Ce{sup 3+}-doped SiO{sub x}N{sub y} thin films with interleaved SiO{sub 2} spacers. Bright green emission and efficient energy transfer from either Ce{sup 3+} ions or Ce silicates to Tb{sup 3+} ions has been observed in the co-doped single layer as a consequence of the strong ion-ion interaction. On the other hand, independent luminescence from Ce{sup 3+} and Tb{sup 3+} ions has been observed in the Ce{sup 3+} and Tb{sup 3+} co-doped bilayer and multilayer, providing a good scenario to develop light emitting devices with wide color tunability by varying the number of deposited films that contain each rare earth dopant. Moreover, the optoelectronic properties of Ce{sup 3+}- and/or Tb{sup 3+}-doped thin films have been studied by depositing transparent conductive electrodes over selected samples. An electroluminescence signal according to the rare earth transitions is obtained in all cases, validating the excitation of Ce{sup 3+} and Tb{sup 3+} ions upon electron injection. Also, the main charge transport of injected electrons has been evaluated and correlated with the layer stoichiometry. Finally, a simple reliability test has allowed disclosing the origin of the early breakdown of test devices, attributed to the excessive joule heating at filament currents that occur around a region close to the polarization point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A procedure for automated land use mapping using remotely sensed multispectral scanner data

A system of processing remotely sensed multispectral scanner data by computer programs to produce color-coded land use maps for large areas is described. The procedure is explained, the software and the hardware are described, and an analogous example of the procedure is presented. Detailed descriptions of the multispectral scanners currently in use are provided together with a summary of the background of current land use mapping techniques. The data analysis system used in the procedure and the pattern recognition software used are functionally described. Current efforts by the NASA Earth Resources Laboratory to evaluate operationally a less complex and less costly system are discussed in a separate section.

Whitley, S. L.↗

Robotic Rock Classification

This report describes a three-month research program undertook jointly by the Robotics Institute at Carnegie Mellon University and Ames Research Center as part of the Ames' Joint Research Initiative (JRI.) The work was conducted at the Ames Research Center by Mr. Liam Pedersen, a graduate student in the CMU Ph.D. program in Robotics under the supervision Dr. Ted Roush at the Space Science Division of the Ames Research Center from May 15 1999 to August 15, 1999. Dr. Martial Hebert is Mr. Pedersen's research adviser at CMU and is Principal Investigator of this Grant. The goal of this project is to investigate and implement methods suitable for a robotic rover to autonomously identify rocks and minerals in its vicinity, and to statistically characterize the local geological environment. Although primary sensors for these tasks are a reflection spectrometer and color camera, the goal is to create a framework under which data from multiple sensors, and multiple readings on the same object, can be combined in a principled manner. Furthermore, it is envisioned that knowledge of the local area, either a priori or gathered by the robot, will be used to improve classification accuracy. The key results obtained during this project are: The continuation of the development of a rock classifier; development of theoretical statistical methods; development of methods for evaluating and selecting sensors; and experimentation with data mining techniques on the Ames spectral library. The results of this work are being applied at CMU, in particular in the context of the Winter 99 Antarctica expedition in which the classification techniques will be used on the Nomad robot. Conversely, the software developed based on those techniques will continue to be made available to NASA Ames and the data collected from the Nomad experiments will also be made available.

Hebert, Martial↗

Developing tools for digital radar image data evaluation

The refinement of radar image analysis methods has led to a need for a systems approach to radar image processing software. Developments stimulated through satellite radar are combined with standard image processing techniques to create a user environment to manipulate and analyze airborne and satellite radar images. One aim is to create radar products for the user from the original data to enhance the ease of understanding the contents. The results are called secondary image products and derive from the original digital images. Another aim is to support interactive SAR image analysis. Software methods permit use of a digital height model to create ortho images, synthetic images, stereo-ortho images, radar maps or color combinations of different component products. Efforts are ongoing to integrate individual tools into a combined hardware/software environment for interactive radar image analysis.

Domik, G.↗

MID-IR enhanced galaxies in the Coma and Virgo clusters: Lenticulars with a high star formation rate

We explore the properties of early-type galaxies (ETGs), including ellipticals (E) and lenticulars (S0), in rich environments, such as clusters of galaxies (Virgo and Coma). The L{sub 24}/L{sub K} distribution of ETGs in both Virgo and Coma clusters shows that some S0s have a much larger L{sub 24}/L{sub K} ratio (0.5 to ∼2 dex) than the bulk of the ETG population. This could be interpreted as an enhanced star formation rate in these lenticulars. We compare the optical colors of galaxies in these two clusters and investigate the nature of these sources with a large L{sub 24}/L{sub K} ratio by looking at their spatial distribution within the cluster, analyzing their optical spectra, and looking at their optical colors compared to late-types. We obtain 10 Coma and 3 Virgo early-type sources with larger L{sub 24}/L{sub K} ratios than the bulk of their population. We call these sources mid-infrared enhanced galaxies (MIEGs). In Coma, they are mostly located in the southwest part of the cluster where a substructure is falling onto the main cluster. MIEGs present a lower g−r color than the rest of the ETG sample because of a blue continuum. We interpret the excess L{sub 24}/L{sub K} ratio as evidence for enhanced star formation induced as a consequence of their infall into the main cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass and Momentum Turbulent Transport Experiments with Confined Coaxial Jets

Downstream mixing of coaxial jets discharging in an expanded duct was studied to obtain data for the evaluation and improvement of turbulent transport models currently used in a variety of computational procedures throughout the propulsion community for combustor flow modeling. Flow visualization studies showed four major shear regions occurring; a wake region immediately downstream of the inlet jet inlet duct; a shear region further downstream between the inner and annular jets; a recirculation zone; and a reattachment zone. A combination of turbulent momentum transport rate and two velocity component data were obtained from simultaneous measurements with a two color laser velocimeter (LV) system. Axial, radial and azimuthal velocities and turbulent momentum transport rate measurements in the r-z and r-theta planes were used to determine the mean value, second central moment (or rms fluctuation from mean), skewness and kurtosis for each data set probability density function (p.d.f.). A combination of turbulent mass transport rate, concentration and velocity data were obtained system. Velocity and mass transport in all three directions as well as concentration distributions were used to obtain the mean, second central moments, skewness and kurtosis for each p.d.f. These LV/LIF measurements also exposed the existence of a large region of countergradient turbulent axial mass transport in the region where the annular jet fluid was accelerating the inner jet fluid.

Johnson, B. V.↗

Ruggedizing a Commercial Depth Camera for Novel Lunar Exploration.

The novel contribution of this instrument is to take the first depth images on the moon. A commercial Kinect camera from Microsoft has been ruggedized for a CLPS mission to the Lunar South Pole. The 12-megapixel color camera is combined with a 1-megapixel color time-of-flight (ToF) depth sensor. The solid-state depth sensor/LIDAR provides greater resolution, a wider field of view, pixel binning, and reduced power consumption. The high-resolution data collected from the mission can be used to construct a near-field virtual environment of the lunar surface for scientific applications. The depth camera can provide a 360-degree view of the target area by combining ToF data with RGB imagery and rover turning. The unit was evaluated for space flight compliant materials and parts at NASA Ames. The microphone array, RF shield, front face, and outer body parts were removed to reduce mass. Plastic parts were replaced with vacuum-compatible materials; manufactured cables were added to properly interface with the host rover, built by Lunar Outpost. The environmental testing was performed on the Kinect with Random Vibration/Sine Testing (Fig 1a), per GEVS (NASA’s General Environmental Verification Standard for spaceflight launch survival). Thermal Vacuum testing cycled the instrument between expected hot (+ 85 C) and cold survival temperatures, as well as +50 C and -25 C operational temps (Fig 1b). The instrument functioned nominally at the conclusion of vibration and thermal cycling tests. The Azure Kinect is manifested on the Nova-C lander which flies on the Intuitive Machines mission IM-2, landing at the lunar south pole for a mission duration of 14 days (one lunar daylight cycle). The unit will be integrated to the MAPP (Mobile Autonomous Prospecting Platform) rover at Lunar Outpost. The Azure Kinect with ToF feature will improve the resolution of lunar geology data near the south pole and enable ground-based VR experience of details of the lunar surface (Fig 1c).

V. Jha↗