Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Multi-Agent Deep Reinforcement Learning for Realistic Distribution System Voltage Control Using PV Inverters

Over the last few decades, the deployment of distributed solar photovoltaic (PV) systems has increased consistently. High PV penetration could cause adverse effects on the grid, such as voltage violations. This paper proposes a new distributed soft actor-critic based multi-agent deep reinforcement learning (SAC-MADRL) control solution to minimize the PV real power curtailment while keeping the grid voltage in an acceptable range. New reward functions have been designed to coordinate different agents during the learning process, yielding improved convergence. Comparison results with other control methods on a real feeder in western Colorado U.S. with 80% penetration of PVs demonstrate that the proposed method has better capability of effectively regulating voltage while minimizing the PV real power curtailment.

distribution system↗

Reinforcement Learning-based Output Structured Feedback for Distributed Multi-Area Power System Frequency Control

Load frequency control (LFC) is a key factor to maintain the stable frequency in multi-area power systems. As the modern power systems evolve from centralized to decentralized paradigm, LFC needs to consider the decentralized scheme that considers limited information from the information-exchange graph for the generator control of each interconnected area. This paper aims to solve a data-driven constrained LQR problem with mean-variance risk constraints and output structured feedback, and applies this framework to solve the LFC problem in multi-area power systems. By reformulating the constrained optimization problem into a minimax problem, the stochastic gradient descent max-oracle (SGDmax) algorithm with zero-order policy gradient (ZOPG) is adopted to find the optimal feedback gain from the learning, while guaranteeing the convergence. In addition, to improve the adaptation of the proposed learning method to new or varying models, we construct an emulator grid that approximates the dynamics of a physical grid and performs training based on this model. Once the feedback gain is obtained from the emulator grid, it is applied to the physical grid with a robustness test to check whether the controller from the approximated emulator applies to the actual system. Numerical tests show that the obtained feedback controller can successfully control the frequency of each area, while mitigating the uncertainty from the loads, with reliable robustness that ensures the adaptability of the obtained feedback gain to the actual physical grid.

Kwon, Kyung-bin↗

Electric actuator modification on a turbine driven feed pump at Calvert Cliffs nuclear power plant - 296

Feedwater systems are a leading contributor to unit SCRAMs as indicated by the 2015 INPO data, where 9 of the 51 SCRAMs recorded were a result of feedwater issues. Digital feedwater control systems and enhanced feed pump control modifications can greatly improve performance and control of the plant feedwater systems and help drive down the potential for reactivity management events and unit SCRAMs. Westinghouse has a strong background in the implementation of digital feedwater control systems, and in planning for a recently completed feedwater control system upgrade at Calvert Cliffs, the Westinghouse team worked with Calvert Cliffs to design a solution to a number of common operational issues. Primarily, improving feedwater control over the entire operating range, eliminating single points of vulnerability (SPV) in the feedwater/feed pump systems and eliminating operational issues with the feed pump steam admission valve hydraulic control oil system. A robust first-of-a-kind design and implementation program was undertaken to split the existing hydraulic valve gear actuator with separate electric actuators. Westinghouse worked with Calvert Cliffs and Emerson Process Management (EPM) to install and commission General Electric (GE) feed pump turbines with separate electric actuators for the high-pressure (HP) and low-pressure (LP) steam admission valves. This successful mechanical and control modification was a first for both the nuclear and non-nuclear power generation industries. Westinghouse is working with a number of other utilities to implement similar modifications for PWR and BWR feed pump applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Minimax approach problem with incomplete information for the two-level hierarchical discrete-time dynamical system

We consider a discrete-time dynamical system consisting of three controllable objects. The motions of all objects are given by the corresponding vector linear or convex discrete-time recurrent vector relations, and control system for its has two levels: basic (first or I level) that is dominating and subordinate level (second or II level) and both have different criterions of functioning and united a priori by determined informational and control connections defined in advance. For the dynamical system in question, we propose a mathematical formalization in the form of solving a multistep problem of two-level hierarchical minimax program control over the terminal approach process with incomplete information and give a general scheme for its solution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimax terminal approach problem in two-level hierarchical nonlinear discrete-time dynamical system

We consider a discrete–time dynamical system consisting of three controllable objects. The motions of all objects are given by the corresponding vector nonlinear or linear discrete–time recurrent vector relations, and control system for its has two levels: basic (first or I level) that is dominating and subordinate level (second or II level) and both have different criterions of functioning and united a priori by determined informational and control connections defined in advance. For the dynamical system in question, we propose a mathematical formalization in the form of solving a multistep problem of two-level hierarchical minimax program control over the terminal approach process with incomplete information and give a general scheme for its solving.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

Feedwater temperature control methods and systems

A system for controlling the power level of a natural circulation boiling water nuclear reactor (NCBWR) may include a heating subsystem for heating feedwater flowing into an annulus of the NCBWR to increase the temperature of recirculation water flowing through the core above a predetermined recirculation water operating temperature. Additionally the system may include a temperature sensor operable to sense the temperature of the feedwater flowing into the annulus. The temperature sensor is communicatively connected to a temperature controller operable to command the heating subsystem to increase the temperature of the feedwater flowing into the annulus to a requested temperature above a predetermined operating temperature of the feedwater flowing into the annulus. By increasing the temperature of the feedwater flowing into the annulus, the temperature of the recirculation water is increased above the predetermined recirculation water operating temperature causing a reduction in the power level generated by the NCBWR core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Synchronous Hydromechanical Drive of a Mobile Machine

A model is developed for the synchronous brush drive of an airfield sweeper. This machine is equipped with a throttle flow divider that is not of gate-valve type, and employs a plunger-type control system. Methods are proposed for improving the static and dynamic properties of the synchronized system.

42 ENGINEERING↗

Efficacy of vibro-impact energy harvesting absorbers on controlling dynamical systems under vortex-induced vibrations and base excitation

Here this study investigates improving the efficacy of an energy harvesting absorber's ability to control a structure under vortex-induced vibrations, base excitation, and a combination of the two by including mechanical amplitude stoppers. The nonlinear reduced-order model is developed through modifying trilinear spring models to represent the impact forces, a modified van der Pol oscillator to represent the forcing due to the vortex-induced vibrations and using the Euler-Lagrange principle to express the equations of motion. It is seen that a soft stopper stiffness and a 5mm gap performs the most effectively of increasing the power generated from the absorber while still greatly reducing the primary structure's amplitude. By changing the stopper's location towards the middle of the energy harvesting absorber, the large effects of the impact forces are reduced and improves the efficacy of medium and hard stopper stiffnesses to generate near the amount of power the soft stopper does, while greatly improving the control of the primary structure. When the system is under combined loadings, the large oscillations of the synchronization region cause the effective configuration to be that of a 27.5 mm gap with soft stiffnesses. The results shows that medium stiffness stoppers with small gaps generate large aperiodic regions due to the high impact force. When the oscillations are close to the stoppers, the beating phenomenon is observed and is not overpowered by the vibro-impact force.

16 TIDAL AND WAVE POWER↗

System and method for controlling hydraulic pressure in electro-hydraulic valve actuation systems

A control system for an engine includes a first lift control module and a second lift control module. The first lift control module increases lift of M valves of the engine to a predetermined valve lift during a period before disabling or re-enabling N valves of the engine. The second lift control module decreases the lift of the M valves to a desired valve lift during a period after enabling or re-enabling the N valves of the engine, wherein N and M are integers greater than or equal to one.

33 ADVANCED PROPULSION SYSTEMS↗

Final Report on HOLODEC 2 Technology Readiness Level

During the period of this project, the Holographic Detector for Clouds 2 (HOLODEC 2) instrument has advanced from a laboratory-proven instrument with some initial field testing to a fully flight-tested instrument capable of providing useful cloud microphysics measurements. This can be summarized as 'Technology Readiness Level 8: Technology is proven to work - Actual technology completed and qualified through test and demonstration.' As part of this project, improvements and upgrades have been made to the optical system, the instrument power control system, the data acquisition computer, the instrument control software, the data reconstruction and analysis software, and some of the basic algorithms for estimating basic microphysical variables like droplet diameter. Near the end of the project, the instrument flew on several research flights as part of the IDEAS 2011 project, and a small sample of data from the project is included as an example. There is one caveat in the technology readiness level stated above: the upgrades to the instrument power system were made after the flight testing, so they are not fully field proven. We anticipate that there will be an opportunity to fly the instrument as part of the IDEAS project in fall 2012.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model predictive current profile control in tokamaks by exploiting spatially moving electron cyclotron current drives

The plasma control systems in next-generation tokamaks like ITER will balance competing control objectives to achieve the desired level of performance in advanced scenarios while preventing magnetohydrodynamic instabilities and disruptions. During normal tokamak operation, the points of incidence of the electromagnetic waves generated by the electron cyclotron heating and current drives (EC H&CDs) are usually fixed in space. However, the points of incidence can be modified in real-time by changing the angles of the mirrors that reflect the EC H&CD waves. Altering the points of incidence, in turn, varies the ability of the plasma control system to regulate a plasma property. For instance, changing the EC H&CD wave incidence location may place the power demands necessary to achieve a particular plasma target within saturation limits. Therefore, using the EC H&CD deposition location, which is related to the EC H&CD mirror angle, as a supplementary controllable variable may facilitate access to a given target scenario. However, active scenario-control algorithms have not been designed so far to fully exploit this capability in real time. In this work, a model predictive controller that can handle actuation locations as control inputs is developed. In particular, the controller is designed to regulate both the auxiliary powers and the EC H&CD deposition locations in a pre-defined optimal sense to achieve the control objective of attaining and sustaining a target current profile. Further, the proposed controller is tested for a DIII-D tokamak scenario in nonlinear simulations using the Control Oriented Transport SIMulator (COTSIM).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mathematical models for base calibration in industrial robots

Mathematical models for the control systems of industrial robots permit calibration of the base, which is a single coordinate space for the industrial robot and the components being manipulated. Calibration of the base precedes operation of the robot. Control systems for industrial robots permit the storage and use of several calibrated bases in programming robot motion.

42 ENGINEERING↗

Evaluation of control strategies for different smart window combinations using computer simulations

Several studies have shown that the use of switchable windows could lower the energy consumption of buildings. Since the main function of windows is to provide daylight and visual contact with the external world, high visible transmittance is needed. From an energy perspective it is always best to have the windows in their low-transparent state whenever there are cooling needs, but this is generally not preferable from a daylight and visual contact point of view. Therefore a control system, which can be based on user presence, is needed in connection with switchable windows. In this study the heating and cooling needs of the building, using different control mechanisms were evaluated. This was done for different locations and for different combinations of switchable windows, using electrochromic glazing in combination with either low-e or solar control glazing. Four control mechanisms were investigated; one that only optimizes the window to lower the need for heating and cooling, one that assumes that the office is in use during the daytime, one based on user presence and one limiting the perpendicular component of the incident solar irradiation to avoid glare and too strong daylight. The control mechanisms were compared using computer simulations. A simplified approach based on the balance temperature concept was used instead of performing complete building simulations. The results show that an occupancy-based control system is clearly beneficial and also that the best way to combine the panes in the switchable window differs depending on the balance temperature of the building and on the climate. It is also shown that it can be beneficial to have different window combinations for different orientations. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PIP-II Beam Current Monitor Fault Case & Beam Position Monitor Linearity Studies in CST Studio

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems. As such, simulations predicting the behavior of these sensors are essential for guiding beamline control system design. This poster details the results returned by two beam sensor models created using CST Studio software: the signal linearity of an elliptical beam position monitor (BPM), and the fault cases of an AC current transformer (ACCT) beam current monitor (BCM).

Rouzky, Adam↗

A Preliminary Investigation into the Mitigation of Plug-in Hybrid Electric Vehicle Tailpipe Emissions Through Supervisory Control Methods Part 2: Experimental Evaluation of Emissions Reduction Methodologies

Plug-in hybrid electric vehicle (PHEV) technologies have the potential for considerable petroleum consumption reductions, possibly at the expense of increased tailpipe emissions due to multiple 'cold' start events and improper use of the engine for PHEV specific operation. PHEVs operate predominantly as electric vehicles (EVs) with intermittent assist from the engine during high power demands. As a consequence, the engine can be subjected to multiple cold start events. These cold start events may have a significant impact on the tailpipe emissions due to degraded catalyst performance and starting the engine under less than ideal conditions. On current hybrid electric vehicles (HEVs), the first cold start of the engine dictates whether or not the vehicle will pass federal emissions tests. PHEV operation compounds this problem due to infrequent, multiple engine cold starts. A continuation of previous analytical work, this research, experimentally verifies a vehicle supervisory control system for a pre-transmission parallel PHEV powertrain architecture. Energy management strategies are evaluated and implemented in a virtual environment for preliminary assessment of petroleum displacement benefits and rudimentary drivability issues. This baseline vehicle supervisory control strategy, developed as a result of this assessment, is implemented and tested on actual hardware in a controlled laboratory environment over a baseline test cycle. Engine cold start events are aggressively addressed in the development of this control system, which leads to enhanced pre-warming and energy-based engine warming algorithms that provide substantial reductions in tailpipe emissions over the baseline supervisory control strategy. The flexibility of the PHEV powertrain allows for decreased emissions during any engine starting event through powertrain 'torque shaping' algorithms. The results of the research show that PHEVs do have the potential for substantial reductions in fuel consumption. Tailpipe emissions from a PHEV test platform have been reduced to acceptable levels through the development and refinement of vehicle supervisory control methods only. Impacts on fuel consumption were minimal for the emissions reduction techniques implemented.

02 PETROLEUM↗