Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Leachate Treatment for Radioactive Waste Containment Mound: Pilot Test and Design - 19098

Canadian Nuclear Laboratories plans to construct an engineered containment mound (ECM) at its Chalk River Laboratories site in Ontario for safe management of radioactive and mixed waste at the facility. The ECM is designed for containment of 1,000,000 cubic meters of waste, and will be operated over a period of 50 years. Contact storm water, leachate, and other wastewater will be generated during operation of the ECM, and must be treated prior to discharge to the environment. The wastewater is projected to contain low concentrations of radionuclides and metals, as well as other cations and anions, and low concentrations of organic chemicals. Through comparison with surface water discharge criteria, radionuclides cesium-137 and strontium-90, and metals including aluminum, barium, copper, iron, lead, and manganese were projected to be present in the wastewater at concentrations that may exceed surface water discharge criteria, and were therefore targeted for treatment. Several technologies, including chemical precipitation, membrane filtration, ion exchange, and reverse osmosis were reviewed and tested on a laboratory scale using simulated wastewater prepared to replicate the concentrations of both target and non-target constituents. Based upon the results of the laboratory-scale tests, a six-week pilot test was conducted to simulate the performance of the technologies under continuous-flow conditions and determine full-scale design criteria. This paper describes the methodology and results of the six-week pilot test, and how the test results were used to inform the full-scale wastewater treatment system design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SMART (Sandia's Modular Architecture for Robotics and Teleoperation) Ver. 1.0

"SMART Ver. 0.8 Beta" provides a system developer with software tools to create a telerobotic control system, i.e., a system whereby an end-user can interact with mechatronic equipment. It consists of three main components: the SMART Editor (tsmed), the SMART Real-time kernel (rtos), and the SMART Supervisor (gui). The SMART Editor is a graphical icon-based code generation tool for creating end-user systems, given descriptions of SMART modules. The SMART real-time kernel implements behaviors that combine modules representing input devices, sensors, constraints, filters, and robotic devices. Included with this software release is a number of core modules, which can be combined with additional project and device specific modules to create a telerobotic controller. The SMART Supervisor is a graphical front-end for running a SMART system. It is an optional component of the SMART Environment and utilizes the TeVTk windowing and scripting environment. Although the code contained within this release is complete, and can be utilized for defining, running, and interfacing to a sample end-user SMART system, most systems will include additional project and hardware specific modules developed either by the system developer or obtained independently from a SMART module developer. SMART is a software system designed to integrate the different robots, input devices, sensors and dynamic elements required for advanced modes of telerobotic control. "SMART Ver. 0.8 Beta" defines and implements a telerobotic controller. A telerobotic system consists of combinations of modules that implement behaviors. Each real-time module represents an input device, robot device, sensor, constraint, connection or filter. The underlying theory utilizes non-linear discretized multidimensional network elements to model each individual module, and guarantees that upon a valid connection, the resulting system will perform in a stable fashion. Different combinations of modules implement different behaviors. Each module must have at a minimum an initialization routine, a parameter adjustment routine, and an update routine. The SMART runtime kernel runs continuously within a real-time embedded system. Each module is first set-up by the kernel, initialized, and then updated at a fixed rate whenever it is in context. The kernel responds to operator directed commands by changing the state of the system, changing parameters on individual modules, and switching behavioral modes. The SMART Editor is a tool used to define, verify, configure and generate source code for a SMART control system. It uses icon representations of the modules, code patches from valid configurations of the modules, and configuration files describing how a module can be connected into a system to lead the end-user in through the steps needed to create a final system. The SMART Supervisor serves as an interface to a SMART run-time system. It provides an interface on a host computer that connects to the embedded system via TCPIIP ASCII commands. It utilizes a scripting language (Tel) and a graphics windowing environment (Tk). This system can either be customized to fit an end-user's needs or completely replaced as needed.

Anderson, Robert↗

Flexible linkages for thermal management at cryogenic temperatures

Cryogenic system design often presents the competing requirements of thermal coupling between components while de-coupling them structurally. Good thermal coupling is necessary for adequate thermal management during cryogenic operation of the system and to reduce the cooldown time from the ambient to cryogenic temperature. Structural de-coupling is essential to reduce thermal stresses during cooldown, mitigate the trasmission of vibration and loads to sensitive and/or fragile components, and compensate for integration misalignments. Flexible thermal links (FTLs) are an essential component of cryogenic systems that provides a balance between thermal coupling and structural isolation.

42 ENGINEERING↗

A Re-Introduction to "Anomalies of Criticality"

In 1974, a small innocuous document was submitted to the American Nuclear Society's Criticality Safety Division for publication that would have lasting impacts on this nuclear field The author was Duane Clayton, manager of the Battelle Pacific Northwest National Laboratory's Critical Mass Lab, the world's preeminent reactor critical experimenter with plutonium solutions. The document was entitled, 'Anomalies of Criticality'. 'Anomalies...' was a compilation of more than thirty separate and distinct examples of departures from what might be commonly expected in the field of nuclear criticality. Mr. Clayton's publication was the derivative of more than ten thousand experiments and countless analytical studies conducted world-wide on every conceivable reactor system imaginable: from fissile bearing solutions to solids, blocks to arrays of fuel rods, low-enriched uranium oxide systems to pure plutonium and highly enriched uranium systems. After publication, the document was commonly used within the nuclear fuel cycle and reactor community to train potential criticality/reactor analysts, experimenters and fuel handlers on important things for consideration when designing systems with critically 'safe' parameters in mind The purpose of this paper is to re-introduce 'Anomalies of Criticality' to the current Criticality Safety community and to add new 'anomalies' to the existing compendium. By so doing, it is the authors' hope that a new generation of nuclear workers and criticality engineers will benefit from its content and might continue to build upon this work in support of the nuclear renaissance that is about to occur.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prefabricated Zero Ascend Omnispecies (ZAO) Modular Fish Passage Modules Using Advanced Manufacturing Techniques

The Zero Ascend Omnispecies (ZAO) fish passage attraction module “ZAO Attractor” is a novel system designed to facilitate upstream passage for a broad spectrum of fish species, with a particular focus on American shad and river herring (alewife and/or blueback herring). Combining the use of prefabricated, modular components with advanced manufacturing, the ZAO aims to provide a cost-effective and scalable solution for fish passage attractions across various hydropower sites. The system features a surface level entry, so fish do not need to climb. In addition, it is designed to be adjusted and repositioned to create the most effective attraction flows by managing the outflows from hydropower turbines. Budget Period 1 (BP1) focused on the design and modeling of the ZAO Attractor and demonstrated the engineering feasibility of a modular, prefabricated, hydrodynamically efficient structure with surface level entry and passage. It was discovered that there were limited published studies on the direct correlation between quantified flow patterns and fish attraction, emphasizing the need for controlled studies to observe and measure these effects. In Budget Period 2 (BP2), controlled studies with live fish were prioritized to address these complexities. In conclusion, the ZAO fish passage attraction module presents a promising approach to fish passage at hydropower stations, with the potential to balance environmental concerns with renewable energy development. However, further field validation and optimization are necessary to ensure its effectiveness and practicality in real-world applications.

13 HYDRO ENERGY↗

Feasibility Evaluation and Retrofit Plan for Cold Crucible Induction Melter Deployment in the Defense Waste Processing Facility at Savannah River Site

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 kHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 deg. C to 200 deg. C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 deg. C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE - 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined Joule heated melters. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed Joule Heated Melter, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations.

36 MATERIALS SCIENCE↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reliability of Open Public Electric Vehicle Direct Current Fast Chargers

The aim was to systematically evaluate the usability of all public electric vehicles (EV) direct current fast chargers (DCFC) in the San Francisco region. To achieve a rapid transition to EVs, a highly reliable and easy to use charging infrastructure is critical to building confidence among consumers. The functionality and usability of all 182 open, public DCFC charging stations with CCS connectors (combined charging system) in the 9 counties of the Bay Area were tested (655 electric vehicle service equipment (EVSE) ports). An EVSE was classified as functional if it charged an EV for 2 minutes. Overall, 73.3% of the 655 EVSEs were functional. The causes of the nonfunctioning EVSEs (23.5%) were blank or unresponsive screens or error messages; payment system failures; charge initiation failures; network failures; or broken connectors. In addition, the cable was too short to reach the EV inlet for 3.2% of the EVSEs. A random sampling of 10% of the EVSEs, approximately 8 days after the first evaluation, found no overall change in functionality. The level of functionality found with field testing conflicts with the 95–98% uptime reported by the EV service providers (EVSPs) who operate the EV charging stations. There is a need for precise and verifiable definitions of uptime, downtime, and excluded time, as applied to public EV chargers. In conclusion, the level of failure of the existing public EV DCFC charge infrastructure highlights the importance of improving the system design and maintenance to improve adoption of EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of solid particle candidates for application in thermal energy storage and concentrating solar power systems

Thermal energy storage (TES) enables concentrating solar power to remain competitive in the renewable energy mix by firming up intermittent solar resource and providing grid services such as load shifting. Free from siting constraints, stand-alone TES systems show promise as a low-cost alternative to traditional pumped-storage hydropower or compressed air energy storage. At the core of all TES technologies is a storage medium, the selection of which governs many aspects of system design and operation. Although the majority of commercial installations utilize molten salts, solid particles can demonstrate stability over wider temperature ranges. This amounts to increased energy storage densities and corresponding reductions in system cost which is essential in achieving low-cost energy storage. In this work, eight solid particle candidates are systematically identified and screened for application in a specific particle-TES system. The five most promising candidates (CARBO CP and HSP, calcined flint clay (CFC), brown fused alumina (BFA), and silica sand) are further characterized by size and morphology for fluidization suitability, flowability for particle transport, and thermal stability. Calcined flint clay and brown fused alumina are eventually down-selected due to thermal instability at the target operational temperature of 1200 °C. Although the physical characteristics of CARBO outperform silica sand in all categories examined, the marginal performance gains are considered insufficient to justify the additional media cost so silica sand is selected as the leading candidate. Within the silica sand (α-quartz) space, the high end of Geldart Group B particles is identified to satisfy the target fluidization regime for the application of interest without compromising particle flowability. Here, in focused testing, Silica 460 is shown to exhibit sufficient stability through long-duration (500-hour) thermal and cyclic testing (1200 °C), 10-hour testing at 1400 °C, and in contact with candidate refractory containment materials. Finally, an average heat capacity of 1.1 J/g∙ °C is measured over 300-1200 °C with a quartz inversion enthalpy (ΔH α-β ) of 10.7J/g.

14 SOLAR ENERGY↗

Air-Cooled Stack Freeze Tolerance

Air-cooled stack technology offers the potential for a simpler system architecture (versus liquid-cooled) for applications below 4 kilowatts. The combined cooling and cathode air allows for a reduction in part count and hence a lower cost solution. However, efficient heat rejection challenges escalate as power and ambient temperature increase. For applications in ambient temperatures below freezing, the air-cooled approach has additional challenges associated with not overcooling the fuel cell stack. The focus of this project was freeze tolerance while maintaining all other stack and system requirements. Through this project, Plug Power advanced the state of the art in technology for air-cooled PEM fuel cell stacks and related GenDrive material handling application fuel cell systems. This was accomplished through a collaborative work plan to improve freeze tolerance and mitigate freeze-thaw effect failure modes within innovative material handling equipment fuel cell systems designed for use in freezer forklift applications. Freeze tolerance remains an area where additional research and understanding can help fuel cells to become commercially viable. This project evaluated both stack level and system level solutions to improve fuel cell stack freeze tolerance. At this time, the most cost effective solutions are at the system level. The freeze mitigation strategies developed over the course of this project could be used to drive fuel cell commercialization. The fuel cell system studied in this project was Plug Power's commercially available GenDrive platform providing battery replacement for equipment in the material handling industry. The fuel cell stacks were Ballard's commercially available FCvelocity 9SSL (9SSL) liquid-cooled PEM fuel cell stack and FCvelocity 1020ACS (Mk1020) air-cooled PEM fuel cell stack.

08 HYDROGEN↗

High Fluence, Multi-pulse Laser Surface Damage: absorbers, mechanisms and mitigation

All optical systems designed to guide high photon fluxes are limited by optical damage and optical stress induced degradation to key optical components including lenses, frequency conversion crystals, antireflection coatings and dielectric multilayer mirrors. These systems include continuous wave (CW) and Giga-shot high average power (HAP) systems for laser machining and DoD applications, and systems for laser driven inertial confinement fusion (ICF) and inertial fusion energy (IFE). Optical degradation and damage begin with near surface defect absorption of sub band-gap light; these effects appear beginning in the near IR (1eV) and become progressively worse for light in the near UV (3 to 4eV). At high enough per pulse fluences (Φ), localized energy deposition is sufficient to create damage sites through explosive ejection of material; this process, optical damage initiation, results in micron sized surface pits which can grow exponentially upon exposure to additional pulses.

42 ENGINEERING↗

Fieldable Platform for Large-Scale Deposition of Concrete Structures

Oak Ridge National Laboratory’s Manufacturing Demonstration Facility is developing a novel, large-scale additive manufacturing, or 3D printing, system. The Sky Big Area Additive Manufacturing (SkyBAAM) system will ultimately be a fieldable concrete deposition machine with pick and place abilities that will allow for full-scale, automated construction of buildings. The system will be implemented with existing construction equipment meaning conventional cranes will be used to suspend the printhead. SkyBAAM will be cable-driven by four base stations and suspended from a single crane. The elimination of a gantry system, found commonly in large-scale additive manufacturing systems, will enable SkyBAAM to be quickly set up with minimal site preparation. The medium-scale version of SkyBAAM is currently in development. The system design, cable stiffness analysis, and tactics for freezing rotational degrees-of-freedom (DOF), detailed in this paper, will provide a basis for the final, large-scale version of the SkyBAAM system.

Chesser, Phillip↗

Residential Ventilation Systems

US homes are increasingly being provided with mechanical ventilation systems that are intended to comply with ASHRAE Standard 62.2. As mechanical ventilation is becoming more prevalent, the industry is gaining knowledge about measured installed performance of mechanical ventilation systems and guidance on how to avoid problem installations. Feedback from industry and research studies has led to several key improvements to the ASHRAE standard giving ventilation system designers more flexibility and providing more energy efficient ventilation solutions. This article summarizes some of the key advances in residential ventilation as well as the results of field investigations of residential ventilation system commissioning and operation/maintenance issues, much of which is from the USDOE Building America program.

Lubliner, Michael↗

A Hardware Platform for Studying Naval Power Electronic Power Distribution Systems

Abstract – Future intelligent ship system designs will likely include electric propulsion, numerous highpower sensors, and directed energy weapons. Supply and control of these large nonlinear loads will require a networked, multi-converter power electronic power distribution system. This work presents a hardware platform to emulate a microgrid power system with multiple power converters and a power data communication network. The platform is reconfigurable and can include both AC and DC power distribution zones, representative of shipboard power systems. It also allows for the study of both power control actuation and power data communication delays. Since the platform is based on electric power hardware, spatial and temporal uncertainties are inherently embedded in the system. Specifically, this work examines the control actuation of multiple pulsed power loads in a single microgrid. Several pulse load levels and operating scenarios have been implemented and measured. A framework for control parameter quantification is presented, and various metrics are explored to capture pulse signal characteristics. The sensitivity of pulse load metric parameters is analyzed. Dynamic shipboard, mission-specific load profiles coupled with pulse loads can also be emulated in the hardware platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MODEL AND ALGORITHM EVALUATION FOR THE HYBRID UF6 CONTAINER INSPECTION SYSTEM

ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing an automated UF6 cylinder verification station concept based on the combined collection of traditional enrichment-meter (186 keV photons from U-235) data and non-traditional, neutron-induced, high-energy gamma-signatures (3-8.5 MeV) with an array of collimated, medium-resolution scintillators. Previous (2010) work at PNNL demonstrated proof-of-principle that this hybrid method yields accurate, full-volume assay of the cylinder enrichment, reduces systematic errors when compared to several other enrichment assay methods, and provides simplified instrumentation and algorithms suitable for long-term unattended operations. We used Monte Carlo modeling with MCNP5 to support system design (e.g., number and configuration of detector arrays, and design of iron/poly collimators for enhanced (n,γ) conversion) and enrichment algorithm development. We developed a first-generation modeling framework in 2010. These tools have since been expanded, refined and benchmarked against field measurements with a prototype system of a 30B cylinder population (0.2 to 4.95 weight % U-235). The MCNP5 model decomposes the radiation transport problem into a linear superposition of “basis spectra” representing contributions from the different uranium isotopes and gamma-ray generation mechanisms (e.g. neutron capture). This scheme accommodates fast generation of “virtual assay signatures” for arbitrary enrichment, material age, and fill variations. Ongoing (FY-2011) refinements to the physics model include accounting for generation of bremsstrahlung photons, arising primarily from the beta decay of Pa-234m, a U-238 daughter. We are using the refined model to optimize collimator design for the hybrid method. The traditional assay method benefits from a high degree of collimation (to isolate each detector’s field-of-view) and relatively small detector area, while the non-traditional method benefits from a wide field-of-view, i.e. less collimation and larger detectors. We implement the enrichment-meter method by applying a square-wave digital filter to a raw spectrum and extracting the 186-keV peak area directly from the convolute spectrum. Ongoing enhancements to this approach include mitigating a systematic peak-area measurement deficit arising from curvature in the spectrum continuum shape. An optimized system prototype based on model results is utilized in a new set of 2011 field measurements, and model and measurement enrichment assay uncertainties are compared.

MODEL AND ALGORITHM EVALUATION FOR THE HYBRID UF6 ↗

Three dimensional finite element methods: Their role in the design of DC accelerator systems

High Voltage Engineering has designed, built and tested a 2 MV dual irradiation system that will be applied for radiation damage studies and ion beam material modification. The system consists of two independent accelerators which support simultaneous proton and electron irradiation (energy range 100 keV - 2 MeV) of target sizes of up to 300 Multiplication-Sign 300 mm{sup 2}. Three dimensional finite element methods were used in the design of various parts of the system. The electrostatic solver was used to quantify essential parameters of the solid-state power supply generating the DC high voltage. The magnetostatic solver and ray tracing were used to optimize the electron/ion beam transport. Close agreement between design and measurements of the accelerator characteristics as well as beam performance indicate the usefulness of three dimensional finite element methods during accelerator system design.

36 MATERIALS SCIENCE↗

A Tool for Life Cycle Climate Performance (LCCP) Based Design of Residential Air Source Heat Pumps

A tool for the design of air source heat pumps (ASHP) based on their life cycle climate performance (LCCP) analysis is presented. The LCCP model includes direct and indirect emissions of the ASHP. The annual energy consumption of the ASHP is determined based on AHRI Standard 210/240. The tool can be used as an evaluation tool when the user inputs the required performance data based on the ASHP type selected. In addition, this tool has system design capability where the user inputs the design parameters of the different components of the heat pump and the tool runs the system simulation software to calculate the performance data. Additional features available in the tool include the capability to perform parametric analysis and sensitivity study on the system. The tool has 14 refrigerants, and 47 cities built-in with the option for the user to add more refrigerants, based on NIST REFPROP, and cities, using TMY-3 database. The underlying LCCP calculation framework is open source and can be easily customized for various applications. The tool can be used with any system simulation software, load calculation tool, and weather and emissions data type.

heat pump↗