Thermal design and development of a planetary probe - Pioneer Venus large probe
The thermal control system developed for the Large Atmospheric Probe of the Pioneer Venus Multiprobe Mission is described. The scope of the thermal control task requires maintaining the probe internal equipment shelf temperatures within a nonoperating range of -40 to 122 F and an operating range of -4 to 122 F during three different mission phases: (1) preseparation, the transit phase of the mission when the probe is attached to the Multiprobe Spacecraft Bus, (2) postseparation, the free-flight cruise phase of the mission following release from the Bus, and (3) descent, the phase of the mission from preentry equipment turn-on to impact on the Venus surface. Thermal control for these phases is achieved by a combination of passive thermal finishes on the probe exterior surfaces and heaters mounted on the equipment shelves. Verification of the adequacy of the total thermal design to meet all mission requirements has been completed.