Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Secondary particle contribution to LET spectra on LDEF

Four experiments utilizing passive detectors (P0006, P0004, A0015, M0004) were flown on LDEF to study the radiation environment. These experiments have been summarized in a companion paper (Benton et al., 1996). One of the experimental goals was to measure LET spectra at different locations and shielding depths with plastic nuclear track detectors (PNTD). It was found that the LET spectra extended well above the LET cutoff imposed by the geomagnetic field on GCR particle penetration into LEO. The high LET particles detected were mostly short-range (range < 2000 m), indicating that they were secondaries produced locally within the PNTD. The presence of these high LET particle fluences is important for the determination of dose equivalent because of the high Quality Factors (Q) involved. A relatively small fraction of particle fluence can contribute a large fraction of dose equivalent. Short-range, inelastic secondary particles produced by trapped protons in the South Atlantic Anomaly (SAA) were found to be a major contributor to the LET spectra above 100 keV/micrometer. The LET spectra were found to extend beyond the approximately 137 keV/micrometer relativistic GCR Fe peak to over 1000 keV/micrometer. The high LET tail of the LET spectra was measured in CR-39 and polycarbonate PNTDs using different techniques. GCR made a relatively modest contribution to the LET spectra as compared to the contributions from short-range secondary particles and stopping protons. LET spectra intercomparisons were made between LDEF measurements and exposures to 154 MeV accelerated proton beams. The similarities support the role of nuclear interactions by trapped protons as the major source of secondary particles in the PNTDs. Also techniques were employed to reduce the range cutoff for detection of the short-range secondaries to approximately 1 micrometer, so that essentially all secondary particles were included in the LET spectra. This has allowed a more realistic assessment of secondary contribution to dose equivalent. Comparisons of measured and calculated LET spectra have been made that demonstrate the need for more accurate modeling of secondary particles in radiation transport codes. Comparisons include preliminary calculations in which attempts have been made to include secondary particles.

long duration↗

Development of the Code RITRACKS

A document discusses the code RITRACKS (Relativistic Ion Tracks), which was developed to simulate heavy ion track structure at the microscopic and nanoscopic scales. It is a Monte-Carlo code that simulates the production of radiolytic species in water, event-by-event, and which may be used to simulate tracks and also to calculate dose in targets and voxels of different sizes. The dose deposited by the radiation can be calculated in nanovolumes (voxels). RITRACKS allows simulation of radiation tracks without the need of extensive knowledge of computer programming or Monte-Carlo simulations. It is installed as a regular application on Windows systems. The main input parameters entered by the user are the type and energy of the ion, the length and size of the irradiated volume, the number of ions impacting the volume, and the number of histories. The simulation can be started after the input parameters are entered in the GUI. The number of each kind of interactions for each track is shown in the result details window. The tracks can be visualized in 3D after the simulation is complete. It is also possible to see the time evolution of the tracks and zoom on specific parts of the tracks. The software RITRACKS can be very useful for radiation scientists to investigate various problems in the fields of radiation physics, radiation chemistry, and radiation biology. For example, it can be used to simulate electron ejection experiments (radiation physics).

Plante, Ianik↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated ISS Flight Utilities

During my internship at NASA Johnson Space Center, I worked in the Space Radiation Analysis Group (SRAG), where I was tasked with a number of projects focused on the automation of tasks and activities related to the operation of the International Space Station (ISS). As I worked on a number of projects, I have written short sections below to give a description for each, followed by more general remarks on the internship experience. My first project is titled "General Exposure Representation EVADOSE", also known as "GEnEVADOSE". This project involved the design and development of a C++/ ROOT framework focused on radiation exposure for extravehicular activity (EVA) planning for the ISS. The utility helps mission managers plan EVAs by displaying information on the cumulative radiation doses that crew will receive during an EVA as a function of the egress time and duration of the activity. SRAG uses a utility called EVADOSE, employing a model of the space radiation environment in low Earth orbit to predict these doses, as while outside the ISS the astronauts will have less shielding from charged particles such as electrons and protons. However, EVADOSE output is cumbersome to work with, and prior to GEnEVADOSE, querying data and producing graphs of ISS trajectories and cumulative doses versus egress time required manual work in Microsoft Excel. GEnEVADOSE automates all this work, reading in EVADOSE output file(s) along with a plaintext file input by the user providing input parameters. GEnEVADOSE will output a text file containing all the necessary dosimetry for each proposed EVA egress time, for each specified EVADOSE file. It also plots cumulative dose versus egress time and the ISS trajectory, and displays all of this information in an auto-generated presentation made in LaTeX. New features have also been added, such as best-case scenarios (egress times corresponding to the least dose), interpolated curves for trajectories, and the ability to query any time in the EVADES output. As mentioned above, GEnEVADOSE makes extensive use of ROOT version 6, the data analysis framework developed at the European Organization for Nuclear Research (CERN), and the code is written to the C++11 standard (as are the other projects). My second project is the Automated Mission Reference Exposure Utility (AMREU).Unlike GEnEVADOSE, AMREU is a combination of three frameworks written in both Python and C++, also making use of ROOT (and PyROOT). Run as a combination of daily and weekly cron jobs, these macros query the SRAG database system to determine the active ISS missions, and query minute-by-minute radiation dose information from ISS-TEPC (Tissue Equivalent Proportional Counter), one of the radiation detectors onboard the ISS. Using this information, AMREU creates a corrected data set of daily radiation doses, addressing situations where TEPC may be offline or locked up by correcting doses for days with less than 95% live time (the total amount time the instrument acquires data) by averaging the past 7 days. As not all errors may be automatically detectable, AMREU also allows for manual corrections, checking an updated plaintext file each time it runs. With the corrected data, AMREU generates cumulative dose plots for each mission, and uses a Python script to generate a flight note file (.docx format) containing these plots, as well as information sections to be filled in and modified by the space weather environment officers with information specific to the week. AMREU is set up to run without requiring any user input, and it automatically archives old flight notes and information files for missions that are no longer active. My other projects involve cleaning up a large data set from the Charged Particle Directional Spectrometer (CPDS), joining together many different data sets in order to clean up information in SRAG SQL databases, and developing other automated utilities for displaying information on active solar regions, that may be used by the space weather environment officers to monitor solar activity. I consulted my mentor Dr. Ryan Rios and Dr. Kerry Lee for project requirements and added features, and ROOT developer Edmond Offermann for advice on using the ROOT library. I also received advice and feedback from Dr. Janet Barzilla of SRAG, who tested my code. Besides these inputs, I worked independently, writing all of the code by myself. The code for all these projects is documented throughout, and I have attempted to write it in a modular format. Assuming that ROOT is updated accordingly, these codes are also Y2038-compliant (and Y10K-compliant). This allows the code to be easily referenced, modified and possibly repurposed for non-ISS missions in the future, should the necessary inputs exist. These projects have taught me a lot about coding and software design - I have become a much more skilled C++ programmer and ROOT user, and I also learned to code in Python and PyROOT (and its advantages and disadvantages compared to C++/ ROOT). Furthermore, I have learned about space radiation and radiation modeling, topics that greatly interest me as I pursue a degree in physics. Working alongside experimental physicists like Dr. Rios, I have developed a greater understanding and appreciation for experimental science, something I have always leaned towards but to which I lacked significant exposure. My work in SRAG has also given me the invaluable opportunity to witness the work environment for physicists at NASA, and what a career in academia may look like at a government laboratory such as NASA Johnson Space Center. As I continue my studies and look forward to graduate school and a future career, this experience at NASA has given me a meaningful and enjoyable opportunity to put my skills to use and see what my future career path might hold.

Offermann, Jan Tuzlic↗

Does administering iodine in radiological procedures increase patient doses?

Purpose: The authors investigated the changes in the pattern of energy deposition in tissue equivalent phantoms following the introduction of iodinated contrast media. Methods: The phantom consisted of a small “contrast sphere,” filled with water or iodinated contrast, located at the center of a 28 cm diameter water sphere. Monte Carlo simulations were performed using MCNP5 codes, validated by simulating irradiations with analytical solutions. Monoenergetic x-rays ranging from 35 to 150 keV were used to simulate exposures to spheres containing contrast agent with iodine concentrations ranging from 1 to 100 mg/ml. Relative values of energy imparted to the contrast sphere, as well as to the whole phantom, were calculated. Changes in patterns of energy deposition around the contrast sphere were also investigated. Results: Small contrast spheres can increase local absorbed dose by a factor of 13, but the corresponding increase in total energy absorbed was negligible (<1%). The highest localized dose increases were found to occur at incident photon energies of about 60 keV. For a concentration of about 10 mg/ml, typical of clinical practice, localized absorbed doses were generally increased by about a factor of two. At this concentration of 10 mg/ml, the maximum increase in total energy deposition in the phantom was only 6%. These simulations demonstrated that increases in contrast sphere doses were offset by corresponding dose reductions at distal and posterior locations. Conclusions: Adding iodine can result in values of localized absorbed dose increasing by more than an order of magnitude, but the total energy deposition is generally very modest (i.e., <10%). Their data show that adding iodine primarily changes the pattern of energy deposition in the irradiated region, rather than increasing patient doses per se.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-05: New Ionization Chamber Dosimetry of Absorbed Dose to Water in Diagnostic KV X-Ray Beams

Purpose: To develop new ionization chamber dosimetry of absorbed dose to water in diagnostic kV x-ray beams, by using a beam quality conversion factor, kQ, for Co-60 to kV x-ray and an ionization conversion factor for a water-substitute plastic phantom. Methods: kQ was calculated for aluminum half value-layers (Al-HVLs) of 1.5 mm to 8 mm which were generated by kV x-ray beams of 50 to 120 kVp. Twenty-two energy spectra for ten effective energies (Eeff) were calculated by a SpecCalc program. Depth doses in water were calculated at 5 × 5 to 30 × 30 cm{sup 2} fields. Output factors were also obtained from the dose ratio for a 10 × 10 cm{sup 2} field. kQ was obtained for a PTW30013 Former ion chamber. In addition, an ionization conversion factor of the PWDT phantom to water was calculated. All calculations were performed with EGSnrc/cavity code and egs-chamber codes. Results: The x-ray beam energies for 1.5 mm to 8 mm Al-HVLs ranged in Eeff of 25.7 to 54.3 keV. kQ for 1.5 mm to 8 mm Al-HVLs were 0.831 to 0.897, at 1 and 2 cm depths for a 10 × 10 cm2 field. Similarly, output factors for 5 × 5 to 30 × 30 cm{sup 2} fields were 0.937 to 1.033 for 25.7 keV and 0.857 to 1.168 for 54.3 keV. The depth dose in a PWDT phantom decreased up to 5% compared to that in water at depth of ten percent of maximum dose for 1.5 mm Al-HVL. The ionization ratios of water/PWDT phantoms for the PTW30013 chamber were 1.012 to 1.007 for 1.5 mm to 8 mm Al-HVLs at 1 cm depth. Conclusion: It became possible to directly measure the absorbed dose to water with the ionization chamber in diagnostic kV x-ray beams, by using kQ and the PWDT phantom.

07 ISOTOPE AND RADIATION SOURCES↗

SCALE 6.2.4 Validation: Radiation Shielding

For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magnetic field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Generation of a novel phase-space-based cylindrical dose kernel for IMRT optimization

Purpose: Improving dose calculation accuracy is crucial in intensity-modulated radiation therapy (IMRT). We have developed a method for generating a phase-space-based dose kernel for IMRT planning of lung cancer patients. Methods: Particle transport in the linear accelerator treatment head of a 21EX, 6 MV photon beam (Varian Medical Systems, Palo Alto, CA) was simulated using the EGSnrc/BEAMnrc code system. The phase space information was recorded under the secondary jaws. Each particle in the phase space file was associated with a beamlet whose index was calculated and saved in the particle's LATCH variable. The DOSXYZnrc code was modified to accumulate the energy deposited by each particle based on its beamlet index. Furthermore, the central axis of each beamlet was calculated from the orientation of all the particles in this beamlet. A cylinder was then defined around the central axis so that only the energy deposited within the cylinder was counted. A look-up table was established for each cylinder during the tallying process. The efficiency and accuracy of the cylindrical beamlet energy deposition approach was evaluated using a treatment plan developed on a simulated lung phantom. Results: Profile and percentage depth doses computed in a water phantom for an open, square field size were within 1.5% of measurements. Dose optimized with the cylindrical dose kernel was found to be within 0.6% of that computed with the nontruncated 3D kernel. The cylindrical truncation reduced optimization time by approximately 80%. Conclusions: A method for generating a phase-space-based dose kernel, using a truncated cylinder for scoring dose, in beamlet-based optimization of lung treatment planning was developed and found to be in good agreement with the standard, nontruncated scoring approach. Compared to previous techniques, our method significantly reduces computational time and memory requirements, which may be useful for Monte-Carlo-based 4D IMRT or IMAT treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-525: Ionization Chamber Perturbation in Flattening Filter Free Beams

Purpose: Changing the characteristic of a photon beam by mechanically removing the flattening filter may impact the dose response of ionization chambers. Thus, perturbation factors of cylindrical ionization chambers in conventional and flattening filter free photon beams were calculated by Monte Carlo simulations. Methods: The EGSnrc/BEAMnrc code system was used for all Monte Carlo calculations. BEAMnrc models of nine different linear accelerators with and without flattening filter were used to create realistic photon sources. Monte Carlo based calculations to determine the fluence perturbations due to the presens of the chambers components, the different material of the sensitive volume (air instead of water) as well as the volume effect were performed by the user code egs-chamber. Results: Stem, central electrode, wall, density and volume perturbation factors for linear accelerators with and without flattening filter were calculated as a function of the beam quality specifier TPR{sub 20/10}. A bias between the perturbation factors as a function of TPR{sub 20/10} for flattening filter free beams and conventional linear accelerators could not be observed for the perturbations caused by the components of the ionization chamber and the sensitive volume. Conclusion: The results indicate that the well-known small bias between the beam quality correction factor as a function of TPR20/10 for the flattening filter free and conventional linear accelerators is not caused by the geometry of the detector but rather by the material of the sensitive volume. This suggest that the bias for flattening filter free photon fields is only caused by the different material of the sensitive volume (air instead of water)

60 APPLIED LIFE SCIENCES↗

SU-F-J-98: Improvement and Evaluation Of Deformation Image Registration On Parotid Glands During Radiation Therapy for Nasopharyngeal Cancer

Purpose: To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions. Two kinds of contours for parotid glands on daily MVCTs were obtained by populating these contours from planning CTs to the daily CTs via rigid-body registration with or without the rotation shifts using the in-house tools and the Adaptive plan software (Adaptive Plan, TomoTherapy), and were edited manually if necessary. The diffeomorphic Demons algorithm developed in the in-house tool was used to propagate the parotid structures from the daily CTs to planning CTs. The differences of the mapped parotid contours in two methods were evaluated using Dice similarity index (DSI). Two-tailed t-test analysis was carried out to compare the DSI changes during the course of RT. Results: For 10 patient plans, the accuracy of deformation image registration (DIR) with the rotation shift was obviously better than those without the rotation shift. The Dice scores of the ipsi- and contra-lateral parotids for with and without the rotation shifts were found to be correlated with each other [0.904±0.031 vs 0.919±0.030 (p<0.001); 0.900±0.031 vs 0.910±0.032 (p<0.001)]. The Dice scores for the parotids have shown the reduction with the changes of parotid volumes during RT. The DSI values between the first and last fraction were 0.932±0.020 vs 0.899±0.030 in 10 patient plans. Conclusion: DIR was successfully improved using the strategic innovation for ART. And the decrease of DIR accuracy has also been found during the delivery of fractionated radiotherapy. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225).

60 APPLIED LIFE SCIENCES↗

Final Review of Safety Assessment Issues at Savannah River Site, August 2011

At the request of Savannah River Nuclear Solutions (SRNS) management, a review team composed of experts in atmospheric transport modeling for environmental radiation dose assessment convened at the Savannah River Site (SRS) on August 29-30, 2011. Though the meeting was prompted initially by suspected issues related to the treatment of surface roughness inherent in the SRS meteorological dataset and its treatment in the MELCOR Accident Consequence Code System Version 2 (MACCS2), various topical areas were discussed that are relevant to performing safety assessments at SRS; this final report addresses these topical areas.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-748: Theoretical Investigation On Using High Energy Proton Beam for Total-Body-Irradiation

Purpose: The broad-slow-rising entrance dose region proximal to the Bragg peak made by a mono-energetic proton beam could potentially be used for total body irradiation (TBI). Due to the quasi-uniform dose deposition, customized thickness compensation may not be required to deliver a uniform dose to patients with varied thickness. We investigated the possibility, efficacy, and hardware requirement to use such proton beam for TBI. Methods: A wedge shaped water phantom with thickness varying from 2 cm to 40 cm was designed to mimic a patient. Geant4 based Monte Carlo code was used to simulate broad mono-energetic proton beams with energy ranging from 250 MeV to 300 MeV radiating the phantom. A 6 MV photon with 1 cm water equivalent build-up used for conventional TBI was also calculated. A paired-opposing beam arrangement with no thickness compensation was used to generate TBI plans for all beam energies. Dose from all particles were scored on a grid size of 2 mm{sup 3}. Dose uniformity across the phantom was calculated to evaluate the plan. The field size limit and the dose uniformity of Mevion S250 proton system was examined by using radiochromic films placed at extended treatment distance with the open large applicator and 90° gantry angle. Results: To achieve a maximum ± 7.5% dose variation, the largest patient thickness variation allowed for 250 MeV, 275 MeV, and 300 MeV proton beams were 27.0 cm, 34.9 cm and 36.7 cm. The value for 6 MV photon beam was only 8.0 cm to achieve the same dose variation. With open gantry, Mevion S250 system allows 5 m source-to-surface distance producing an expected 70 cm{sup 2} field size. Conclusion: Energetic proton beam can potentially be used to deliver TBI. Treatment planning and delivery would be much simple since no thickness compensation is required to achieve a uniform dose distribution.

60 APPLIED LIFE SCIENCES↗

Maxdose-SR and popdose-SR routine release atmospheric dose models used at SRS

MAXDOSE-SR and POPDOSE-SR are used to calculate dose to the offsite Reference Person and to the surrounding Savannah River Site (SRS) population respectively following routine releases of atmospheric radioactivity. These models are currently accessed through the Dose Model Version 2014 graphical user interface (GUI). MAXDOSE-SR and POPDOSE-SR are personal computer (PC) versions of MAXIGASP and POPGASP, which both resided on the SRS IBM Mainframe. These two codes follow U.S. Nuclear Regulatory Commission (USNRC) Regulatory Guides 1.109 and 1.111 (1977a, 1977b). The basis for MAXDOSE-SR and POPDOSE-SR are USNRC developed codes XOQDOQ (Sagendorf et. al 1982) and GASPAR (Eckerman et. al 1980). Both of these codes have previously been verified for use at SRS (Simpkins 1999 and 2000). The revisions incorporated into MAXDOSE-SR and POPDOSE-SR Version 2014 (hereafter referred to as MAXDOSE-SR and POPDOSE-SR unless otherwise noted) were made per Computer Program Modification Tracker (CPMT) number Q-CMT-A-00016 (Appendix D). Version 2014 was verified for use at SRS in Dixon (2014).

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Dose–Dependent Hippocampal Atrophy Detected With Longitudinal Volumetric Magnetic Resonance Imaging

Purpose: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. Methods and Materials: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI before and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. Results: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=−0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean −6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). Conclusions: The hippocampus demonstrates radiation dose–dependent atrophy after treatment for brain tumors. Quantitative MRI is a noninvasive imaging technique capable of measuring radiation effects on intracranial structures. This technique could be investigated as a potential biomarker for development of reliable dose constraints for improved cognitive outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise {sub (}ΔΤ{sub )} according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronics Analysis for ITER Diagnostic Generic Upper Port Plug

This paper presents new results of neutronics analysis performed for the updated design of the ITER Diagnostic Generic Upper Port Plug (DGUPP). Such analysis is performed regularly during the development of the ITER Ports design. Neutronics analysis is an important step in support of the development of ITER components irradiated by 14 MeV neutrons generated in D-T fusion thermonuclear reactions. The neutrons are born in the ITER tokamak plasma chamber and then impinge on the surrounding blanket and port plugs, after that they diffuse through shielding material of vacuum vessel components or could stream through the diagnostic channels and assembly gaps far away from plasma up to the bio-shield and in a small amount beyond it. While ITER machine is in operation it is inaccessible, after the shut-down it is planned to provide personnel access to the Upper Port Inter-Space Structure (UP ISS) behind the Port Plug via the corridors. Neutrons activate the ITER materials and those radioactive materials emit decay gammas during the shut-down causing a Shut-Down Dose Rate (SDDR) field distributed all around the activated materials. Decay gammas could also stream through the void channels. That emphasizes the need for calculation of decay gamma transport in evaluations of SDDR, which is reflected in the use of transport - activation interface code described in Section of Computational Modelling. The assessment of radiation environment (fluxes and SDDR) at DGUPP was focused on the port back-side area of UP ISS, where personnel access is planned along the ISS maintenance corridors. Minimization of SDDR at the front part of the ISS maintenance corridors was the target value for optimization of the DGUPP shielding and analysis of related neutronics effects. Following the dose ALARA (As Low As Reasonably Achievable) principle, every possibility to reduce SDDR should be investigated, emphasizing the importance of this analysis. The challenges of such analysis are inextricably connected with the engineering complexity of the ITER machine, with integration of many diagnostics systems having channels and gaps inside the ITER ports. Those gaps result in radiation streaming and negatively affect the shielding performance of the port plugs. The computational complication is caused by the need to model precisely the ITER geometry and then to run deep penetrating radiation transport in the substantially heterogenic toroidal geometry of ITER large-size tokamak, with 30 m height and diameter of its bio-shield. The whole mass of Upper Port Plug (UPP) could be up to 25 tons and it must be very precisely positioned inside the port opening in blanket and Vacuum Vessel. Facing the engineering challenges for the assembly of DGUPP, there were proposed two Project Change Requests (PCRs) No. 439 and 709 concerning the design updates of UPP/blanket interface and its remote handling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Effect of explicit M and N-shell atomic transitions on a low-energy x-ray source

Purpose: In EGSnrc, atomic transitions to and from the M and N-shells are treated in an average way by default. This approach is justified in which the energy difference between explicit and average M and N-shell binding energies is less than 1 keV, and for most applications can be considered negligible. However, for simulations of low energy x-ray sources on thin, high-Z targets, characteristic x-rays can make up a significant portion of the source spectra. As of release V4-2.4.0, EGSnrc has included an option to enable a more complete algorithm of all atomic transitions available in the EADL compilation. In this paper, the effect of M and N-shell averaging on the calculation of half-value layer (HVL) and relative depth dose (RDD) curve of a 50 kVp intraoperative x-ray tube with a thin gold target was investigated. Methods: A 50 kVp miniature x-ray source with a gold target (The INTRABEAM System, Carl Zeiss, Germany) was modeled with the EGSnrc user code cavity, both with and without M and N-shell averaging. From photon fluence spectra simulations, the source HVLs were determined analytically. The same source model was then used with egs-chamber to calculate RDD curves in water. Results: A 4% increase of HVL was reported when accounting for explicit M and N-shell transitions, and up to a 9% decrease in local relative dose for normalization at 3 mm depth in water. Conclusions: The EGSnrc default of using averaged M and N-shell binding energies has an observable effect on the HVL and RDD of a low energy x-ray source with high-Z target. For accurate modeling of this class of devices, explicit atomic transitions should be included.

60 APPLIED LIFE SCIENCES↗