Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Cosmic polarimetry in magnetoactive plasmas

Polarimetry of the cosmic microwave background represents one of the possible diagnostics aimed at testing large-scale magnetism at the epoch of the photon decoupling. The propagation of electromagnetic disturbances in a magnetized plasma leads naturally to a B-mode polarization whose angular power spectrum is hereby computed both analytically and numerically. Combined analyses of all the publicly available data on the B-mode polarization are presented, for the first time, in the light of the magnetized {lambda}CDM scenario. Novel constraints on preequality magnetism are also derived in view of the current and expected sensitivities to the B-mode polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband imaging with one planar diffractive lens

We demonstrate imaging over the visible band using a single planar diffractive lens. This is enabled via multi-level diffractive optics that is designed to focus over a broad wavelength range, which we refer to as an achromatic diffractive lens (ADL). We designed, fabricated and characterized two ADLs with numerical apertures of 0.05 and 0.18. Diffraction-limited focusing is demonstrated for the NA = 0.05 lens with measured focusing efficiency of over 40% across the entire visible spectrum (450 nm to 750 nm). We characterized the lenses with a monochromatic and a color CMOS sensor, and demonstrated video imaging under natural sunlight and other broadband illumination conditions. We use rigorous electromagnetic simulations to emphasize that ADLs can achieve high NA (0.9) and large operating bandwidth (300 nm in the visible spectrum), a combination of metrics that have so far eluded other flat-lens technologies such as metalenses. Here, these planar diffractive lenses can be cost-effectively manufactured over large areas and thereby, can enable the wide adoption of flat, low-cost lenses for a variety of imaging applications.

47 OTHER INSTRUMENTATION↗

Minimization of nanosatellite low frequency magnetic fields

Small weight and dimensions of the micro- and nanosatellites constrain researchers to place electromagnetic sensors on short booms or on the satellite body. Therefore the electromagnetic cleanliness of such satellites becomes a central question. This paper describes the theoretical base and practical techniques for determining the parameters of DC and very low frequency magnetic interference sources. One of such sources is satellite magnetization, the reduction of which improves the accuracy and stability of the attitude control system. We present design solutions for magnetically clean spacecraft, testing equipment, and technology for magnetic moment measurements, which are more convenient, efficient, and accurate than the conventional ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contactless excitation of acoustic resonance in insulating wafers

Contactless excitation and detection of high harmonic acoustic overtones in a thin insulator single crystal are described using radio frequency spectroscopy techniques. Single crystal [001] silicon wafer samples were investigated, one side covered with a Nb thin film, the common starting point for the fabrication of quantum devices. Additionally, the coupling between electromagnetic signals and mechanical oscillation is achieved from the Lorentz force generated by an external magnetic field. This method is suitable for any sample with a metallic surface or covered with a thin metal film. High resolution measurements of the temperature dependence of the sound velocity and elastic constants of silicon are reported and compared with known results.

47 OTHER INSTRUMENTATION↗

Remote Gamma Ray Spectrum Acquisition

An approach is presented that utilizes networking, hardware, and software components to allow data acquisition from Canberra's Osprey multi-channel analyzer (MCA) detector. The research has allowed researchers to remotely connect to Canberra's ProSpect gamma spectroscopy software and the detector by making use of Windows Server 2012 and a network connection. Gamma rays are ionizing, electromagnetic radiation of high energy and short wavelength. They are produced primarily by radioactive decay. Several undergraduate courses at Texas A and M University-Kingsville focus on teaching students to measure and research gamma rays while in the laboratory. Recent needs have motivated efforts to develop a network solution that allows authorized students and researchers to access the ProSpect software and Osprey MCA detectors remotely from multiple computers connected to the campus network. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetized Plasma-filled Waveguide: A New High-Gradient Accelerating Structure

Electromagnetic waves confined between the metal plates of a plasma-filled waveguide are investigated. It is demonstrated that when the plasma is magnetized along the metallic plates, there exists a luminous accelerating wave propagating with a very slow group velocity. It is shown that the magnetized plasma 'isolates' the metal wall from the transverse electric field, thereby reducing potential breakdown problems. Applications of the metallic plasma-filled waveguide to particle accelerations and microwave pulse manipulation are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The International X-ray Observatory

The International X-ray Observatory (IXO) is a joint ESA-JAXA-NASA effort to address fundamental and timely questions in astrophysics: What happens close to a black hole? How did supermassive black holes grow? How does large scale structure form? What is the connection between these processes? To address these questions IXO will employ optics with 3 sq m collecting area and 5 arc sec angular resolution--20 times more collecting area at 1 keV than any previous X-ray observatory. Focal plane instruments will deliver a 100-fold increase in effective area for high-resolution spectroscopy, deep spectral imaging over a wide field of view, unprecedented polarimetric sensitivity, microsecond spectroscopic timing, and high count rate capability. The mission is being planned for launch in 2021 to an L2 orbit, with a five-year lifetime and consumables for 10 years.

79 ASTRONOMY AND ASTROPHYSICS↗

SPIDER OPTIMIZATION. II. OPTICAL, MAGNETIC, AND FOREGROUND EFFECTS

SPIDER is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. SPIDER's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental systematic errors must be controlled with unprecedented accuracy. Here, we build on previous work to use simulations of SPIDER observations to examine the impact of several systematic effects that have been characterized through testing and modeling of various instrument components. In particular, we investigate the impact of the non-ideal spectral response of the half-wave plates, coupling between focal-plane components and Earth's magnetic field, and beam mismatches and asymmetries. We also present a model of diffuse polarized foreground emission based on a three-dimensional model of the Galactic magnetic field and dust, and study the interaction of this foreground emission with our observation strategy and instrumental effects. We find that the expected level of foreground and systematic contamination is sufficiently low for SPIDER to achieve its science goals.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration Development and Testing of Rear Transition Monitor for Beam Current Monitoring System

Addressing baseline effects in accelerator environments is crucial for accurate data acquisition and analysis, since baseline effects can obscure signal clarity and impact the reliability of beam current monitoring systems. There are many potential contributors to baseline noise, such as variations in beam dynamics, electromagnetic interference from nearby equipment, or RF interference. Previous applications of noise reduction systems don t sufficiently filter sources of asynchronous noise, so a new algorithm was implemented. A simulation dataset was created to replicate beam conditions and a Red Pitaya FPGA was used to collect data through the streaming application. A Python script was developed to implement noise reduction algorithms and efforts were made to integrate real-time data streaming with the Redis platform and Acnet Front End infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CLUSTER OF COMPACT RADIO SOURCES IN W40

We present deep 3.6 cm radio continuum observations of the H II region W40 obtained using the Very Large Array (VLA) in its A and B configurations. We detect a total of 20 compact radio sources in a region of 4' x 4', with 11 of them concentrated in a band with 30'' of extent. We also present JHK photometry of the W40 cluster taken with the QUIRC instrument on the University of Hawaii 2.2 m telescope. These data reveal that 15 of the 20 VLA sources have infrared counterparts, and 10 show radio variability with periods less than 20 days. Based on these combined radio and IR data, we propose that eight of the radio sources are candidate ultracompact H II regions, seven are likely to be young stellar objects, and two may be shocked interstellar gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Developing Uncertainty Quantification Strategies in Electromagnetic Problems Involving Highly Resonant Cavities

High-quality factor resonant cavities are challenging structures to model in electromagnetics owing to their large sensitivity to minute parameter changes. Therefore, uncertainty quantification (UQ) strategies are pivotal to understanding key parameters affecting the cavity response. Furthermore, we discuss here some of these strategies focusing on shielding effectiveness (SE) properties of a canonical slotted cylindrical cavity that will be used to develop credibility evidence in support of predictions made using computational simulations for this application.

47 OTHER INSTRUMENTATION↗

Status of the endcap BGO calorimeter of the CMD-3 detector

The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e{sup +}e{sup -} collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 {+-}1 deg. C was designed and manufactured. All blocks of the endcap calorimeter are assembled, tested, and prepared for installing at the detector.

43 PARTICLE ACCELERATORS↗

Improvement of the technique of identification of electrons and positrons with use of electromagnetic calorimeter of the CLAS detector

We study the dependence of the sensitivity of response of the electromagnetic calorimeter of CLAS plant on the momenta of electrons and positrons. We made calculation of this dependence and elaborated a method for its employment in identification of e- and e+. We have shown that the new method of selection of e- and e+ improves the quality of identification by about 10%. We used the experimental data obtained with the plant CLAS of linear accelerator at Jefferson laboratory (USA).

43 PARTICLE ACCELERATORS↗

Millimeter wave sensor for far-field standoff vibrometry

A millimeter wavelength (MMW) measurement system for remote detection of object characteristics and methods for detecting such characteristics. The MMW measurement system comprises a front-end and an optional signal conditioning component. The MMW front-end includes an oscillator, a transceiver portion, and an antenna for focusing a detection component comprising micrometer level wavelength electromagnetic radiation onto the object. A portion of the electromagnetic radiation reflected by the object is received by the MMW measurement system, which is indicative of a displacement of the object. The MMW system may be configured to detect micrometer level displacement of the object disposed tens of meters from the MMW measurement system. In various embodiments the object may be a natural object, including a human, and the displacement may be indicative of a heart rate and/or a respiratory function.

42 ENGINEERING↗

Faraday rotation, stochastic magnetic fields, and CMB maps

The high- and low-frequency descriptions of the predecoupling plasma are deduced from the Vlasov-Landau treatment generalized to curved space-times and in the presence of the relativistic fluctuations of the geometry. It is demonstrated that the interplay between one-fluid and two-fluid treatments is mandatory for a complete and reliable calculation of the polarization observables. The Einstein-Boltzmann hierarchy is generalized to handle the dispersive propagation of the electromagnetic disturbances in the predecoupling plasma. Given the improved physical and numerical framework, the polarization observables are computed within the magnetized {lambda}CDM paradigm (m{lambda}CDM). In particular, the Faraday-induced B-mode is consistently estimated by taking into account the effects of the magnetic fields on the initial conditions of the Boltzmann hierarchy, on the dynamical equations, and on the dispersion relations. The complete calculations of the angular power spectra constitute the first step for the derivation of magnetized maps of the CMB temperature and polarization which are here obtained for the first time and within the minimal m{lambda}CDM model. The obtained results set the ground for direct experimental scrutiny of large-scale magnetism via the low- and high-frequency instruments of the Planck explorer satellite.

79 ASTRONOMY AND ASTROPHYSICS↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Test Beamline on Diamond Light Source

A Test beamline B16 has been built on the 3 GeV Diamond synchrotron radiation source. The beamline covers a wide photon energy range from 2 to 25 keV. The beamline is highly flexible and versatile in terms of the available beam size (a micron to 100 mm) and the range of energy resolution and photon flux; by virtue of its several operational modes, and the different inter-changeable instruments available in the experiments hutch. Diverse experimental configurations can be flexibly configured using a five-circle diffractometer, a versatile optics test bench, and a suite of detectors. Several experimental techniques including reflectivity, diffraction and imaging are routinely available. Details of the beamline and its measured performance are presented.

43 PARTICLE ACCELERATORS↗

Energy weighting for the upgrade of the CMS HCAL

In these simulation studies an energy weighting method is applied to the signals of the CMS hadronic calorimeter readout with a longitudinal segmentation for a possible future upgrade. Tabulated weighting factors are used to compensate for the different response of hadronic and electromagnetic energy depositions of simulated pion showers in the hadronic calorimeter. The weighting improves the relative energy resolution: ( Greek-Small-Letter-Sigma {sub E}/E){sup 2} = [((92.2 {+-} 0.6)%/{radical}E){sup 2} + ((6.5 {+-} 01)%{sup 2}] (before weighting), (( Greek-Small-Letter-Sigma {sub E,weight}/E){sup 2} = [((85.4 {+-} 0.5)%/{radical}E){sup 2} + ((4.4 {+-} 0.1)%{sup 2}] (after weighting), where E in the square root has units of GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗