Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPERIMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Enabling Modular Autonomous Feedback‐Loops in Materials Science through Hierarchical Experimental Laboratory Automation and Orchestration

Abstract Materials acceleration platforms (MAPs) operate on the paradigm of integrating combinatorial synthesis, high‐throughput characterization, automatic analysis, and machine learning. Within a MAP, one or multiple autonomous feedback loops may aim to optimize materials for certain functional properties or to generate new insights. The scope of a given experiment campaign is defined by the range of experiment and analysis actions that are integrated into the experiment framework. Herein, the authors present a method for integrating many actions within a hierarchical experimental laboratory automation and orchestration (HELAO) framework. They demonstrate the capability of orchestrating distributed research instruments that can incorporate data from experiments, simulations, and databases. HELAO interfaces laboratory hardware and software distributed across several computers and operating systems for executing experiments, data analysis, provenance tracking, and autonomous planning. Parallelization is an effective approach for accelerating knowledge generation provided that multiple instruments can be effectively coordinated, which the authors demonstrate with parallel electrochemistry experiments orchestrated by HELAO. Efficient implementation of autonomous research strategies requires device sharing, asynchronous multithreading, and full integration of data management in experimental orchestration, which to the best of the authors’ knowledge, is demonstrated for the first time herein.

36 MATERIALS SCIENCE↗

Experimental validation of a Kalman observer using linearized OpenFAST and a fully instrumented 1:70 model

Abstract To enable real‐time monitoring and control strategies for floating offshore wind turbines, accurate information about the state of the system is needed. This paper details the application of a Kalman filter to the UMaine VolturnUS‐S floating wind platform to provide accurate state estimates in real time using minimal system measurements. The midfidelity nonlinear simulation tool OpenFAST was used to generate the underlying linear state‐space model for the Kalman filter. This linear model and its limitations are demonstrated through comparison with experimental data collected on a 1:70 froude‐scaled model of the floating platform and tower. Using a selection of five measurements from the real system, a Kalman filter was developed to provide estimates for the remaining system states and measurements. These estimates were then validated against the experimental values collected from testing of the scale model. Validation of the Kalman filter produced accurate estimates of surge, heave, and tower base bending moment, measurements of which were not available to the Kalman filter. Performance of the Kalman filter was tested and validated over a range of sea conditions from rated wind speed to storm events and demonstrated robustness in the Kalman filter to maintain accuracy across all operating conditions despite significant error in the underlying linear model for extreme conditions.

17 WIND ENERGY↗

Chapter 14: Dynamic Flux Analysis: An Experimental Approach of Fluxomics

Metabolic flux analysis represents an essential perspective to understand cellular physiology and offers quantitative information to guide pathway engineering. A valuable approach for experimental elucidation of metabolic flux is dynamic flux analysis, which estimates the relative or absolute flow rates through a series of metabolic intermediates in a given pathway. It is based on kinetic isotope labeling experiments, liquid chromatography-mass spectrometry (LC-MS), and computational analysis that relate kinetic isotope trajectories of metabolites to pathway activity. Herein, we illustrate the mathematic principles underlying the dynamic flux analysis and mainly focus on describing the experimental procedures for data generation. This protocol is exemplified using cyanobacterial metabolism as an example, for which reliable labeling data for central carbon metabolites can be acquired quantitatively. This protocol is applicable to other microbial systems as well and can be readily adapted to address different metabolic processes.

BASIC BIOLOGICAL SCIENCES↗

Multidimensional sum-up rounding for integer programming in optimal experimental design

Here we present a numerical method for approximating the solution of convex integer programs stemming from optimal experimental design. The statistical setup consists of a Bayesian framework for linear inverse problems for which the direct relationship is described by a discretized integral equation. Specifically, we aim to find the optimal sensor placement from a set of candidate locations where data are collected with measurement error. The convex objective function is a measure of the uncertainty, described here by the trace or log-determinant of the posterior covariance matrix, for the discretized linear inverse problem solution. The resulting convex integer program is relaxed, producing a lower bound. An upper bound is obtained by extending the sum-up rounding approach to multiple dimensions. For this extension, we analyze its accuracy as a function of the discretization mesh size for a rectangular domain. We show asymptotic optimality of the integer solution defining the upper bound for different experimental design criteria (A- and D-optimal), by proving the convergence to zero of the gap between the upper and lower bounds as the mesh size goes to zero. The technique is illustrated on a two-dimensional gravity surveying problem for both A-optimal and D-optimal sensor placement where our designs yield better results compared with a thresholding rounding approach.

97 MATHEMATICS AND COMPUTING↗

Giant dipole resonance parameters of ground-state photoabsorption: Experimental values with uncertainties

Updated values and corresponding uncertainties of Isovector Giant Dipole Resonance (GDR) parameters which are obtained by the least-squares fitting of theoretical photoabsorption cross sections to experimental data are presented. The theoretical photoabsorption cross sections are taken as a sum of the components corresponding to the excitation of the GDR and quasideuteron photodisintegration. The current compilation is an extension and improvement of the earlier compilations of Lorentzian parameters for ground-state photoneutron and photoabsorption cross sections and covers experimental data made available up to June 2017.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Preliminary experimental comparison and feasibility analysis of CO2/R134a mixture in Organic Rankine Cycle for waste heat recovery from diesel engines

This paper presents results of a preliminary experimental study of the Organic Rankine Cycle (ORC) using CO2/R134a mixture based on an expansion valve. The goal of the research was to examine the feasibility and effectiveness of using CO 2 mixtures to improve system performance and expand the range of condensation temperature for ORC system. The mixture of CO 2 /R134a (0.6/0.4) on a mass basis was selected for comparison with pure CO 2 in both the preheating ORC (P-ORC) and the preheating regenerative ORC (PR-ORC). Then, the feasibility and application potential of CO 2 /R134a (0.6/0.4) mixture for waste heat recovery from engines was tested under ambient cooling conditions. Preliminary experimental results using an expansion valve indicate that CO 2 /R134a (0.6/0.4) mixture exhibits better system performance than pure CO 2 . For PR-ORC using CO 2 /R134a (0.6/0.4) mixture, assuming a turbine isentropic efficiency of 0.7, the net power output estimation, thermal efficiency and exergy efficiency reached up to 5.30 kW, 10.14% and 24.34%, respectively. For the fitting value at an expansion inlet pressure of 10 MPa, the net power output estimation, thermal efficiency and exergy efficiency using CO2/R134a (0.6/0.4) mixture achieved increases of 23.3%, 16.4% and 23.7%, respectively, versus results using pure CO2 as the working fluid. Finally, experiments showed that the ORC system using CO2/R134a (0.6/0.4) mixture is capable of operating stably under ambient cooling conditions (25.2-31.5 °C), demonstrating that CO 2 /R134a mixture can expand the range of condensation temperature and alleviate the low-temperature condensation issue encountered with CO 2 . Under the ambient cooling source, it is expected that ORC using CO 2 /R134a (0.6/0.4) mixture will improve the thermal efficiency of a diesel engine by 1.9%.

42 ENGINEERING↗

CatTestHub: A benchmarking database of experimental heterogeneous catalysis for evaluating advanced materials

The ability to quantitatively compare newly evolving catalytic materials and technologies is hindered by the widespread availability of catalytic data collected in a consistent manner. While certain catalytic chemistries have been widely studied across decades of scientific research, quantitative comparisons based on literature information is hindered by variability in reaction conditions, types of reported data, and reporting procedures. Here, we present CatTestHub, an open-access database dedicated to benchmarking experimental heterogeneous catalysis data. Combining systematically reported catalytic activity data for selected probe chemistries, with relevant material characterization and reactor configuration information, the database provides a collection of catalytic benchmarks for distinct classes of active site functionality. Through key choices in data access, availability, and traceability, CatTestHub seeks to balance the fundamental information needs of chemical catalysis and the FAIR data design principles. Details of the database architecture and the means through which to navigate it are presented, highlighting examples of catalytic insights readily drawn from the available benchmarking data. In its current iteration, CatTestHub spans over 250 unique experimental data points, collected over 24 solid catalysts, that facilitated the turnover of 3 distinct catalytic chemistries. Here, a roadmap is presented through which to expand the open-access platform that serves as a community wide benchmark, primarily through continuous addition of kinetic information on select catalytic systems by members of the heterogeneous catalysis community at large.

Benchmark↗

High-fidelity wind farm simulation methodology with experimental validation

The complexity and associated uncertainties involved with atmospheric-turbine-wake interactions produce challenges for accurate wind farm predictions of generator power and other important quantities of interest (QoIs), even with state-of-the-art high-fidelity atmospheric and turbine models. A comprehensive computational study was undertaken with consideration of simulation methodology, parameter selection, and mesh refinement on atmospheric, turbine, and wake QoIs to identify capability gaps in the validation process. For neutral atmospheric boundary layer conditions, the massively parallel large eddy simulation (LES) code Nalu-Wind was used to produce high-fidelity computations for experimental validation using high-quality meteorological, turbine, and wake measurement data collected at the Department of Energy/Sandia National Laboratories Scaled Wind Farm Technology (SWiFT) facility located at Texas Tech University’s National Wind Institute. The wake analysis showed the simulated lidar model implemented in Nalu-Wind was successful at capturing wake profile trends observed in the experimental lidar data.

17 WIND ENERGY↗

Critical mineral substitutions in IN617: A combined computational and experimental approach to performance evaluation and feasibility

Addressing the escalating demand for critical minerals (CMs) driven by global climate change initiatives, this study explores compositional modifications to Inconel 617 (IN617) by substituting cobalt (Co) with manganese (Mn) across various atomic percentages. Here, we conducted a computational feasibility study employing Molecular Dynamics (MD) simulations to provide strategic guidance for experimental validation. The simulations analyzed tensile strength and corrosion resistance for five modified compositions (M1 to M5) to identify optimal properties. Tensile tests on cubic simulation cells were performed to generate stress-strain curves, revealing the impact of Co replacement with Mn on tensile strength—a metric correlated with hardness. Oxygen penetration simulations were conducted to evaluate corrosion resistance, indicating that reduced oxygen penetration depth corresponds to enhanced resistance. Promising compositions underwent phase diagram calculations for assessing phase stability. The optimal composition (M1), characterized by high tensile strength and minimal oxygen penetration, was chosen for experimental validation using induction melting and friction stir consolidation techniques. The materials were further characterized using SEM-EDS, XRD, and Vickers hardness testing. Our findings suggest that Mn substitution in IN617 can yield mechanical performance at par with high-Co alloys in energy-critical applications.

36 MATERIALS SCIENCE↗

Comparison of experimental and simulation results on interior subchannels of a 61-pin wire-wrapped hexagonal fuel bundle

As part of a joint U.S. Department of Energy project, Framatome, Argonne National Laboratory, Terrapower, and Texas A&M University have collaborated to produce experimental data and computational results to characterize the flow behavior of a 61-pin wire-wrapped hexagonal fuel bundle. Here, comparisons are made between Texas A&M’s experimental particle image velocimetry velocity field measurements and Argonne National Laboratory’s large-eddy simulation results in an interior subchannel for a Reynolds number of 19,000. It can be concluded that the shape and magnitude of the mean vertical velocity component is in excellent agreement for the selected horizontal line plots. Maximum relative errors are less than 10% until the subchannel walls are approached. Finally, the shape and, to a lesser extent, magnitude of the mean horizontal velocity component is in satisfactory agreement between the particle image velocimetry and large-eddy simulation results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward autonomous laboratories: Convergence of artificial intelligence and experimental automation

The ever-increasing demand for novel materials with superior properties inspires retrofitting traditional research paradigms in the era of artificial intelligence and automation. An autonomous experimental platform (AEP) has emerged as an exciting research frontier that achieves full autonomy via integrating data-driven algorithms such as machine learning (ML) with experimental automation in the material development loop from synthesis, characterization, and analysis, to decision making. In this review, we started with a primer to describe how to develop data-driven algorithms for solving material problems. Then, we systematically summarized recent progress on automated material synthesis, ML-enabled data analysis, and decision-making. Finally, we discussed the challenges and opportunities in an endeavor to develop the next-generation AEP for ultimately realizing an autonomous or self-driving laboratory. In conclusion, this review will provide insights for researchers aiming to learn the frontier of ML in materials science and deploy AEP in their labs for accelerating material development.

36 MATERIALS SCIENCE↗

Experimental demonstration of a data-driven control system for subcritical nuclear facility

Here this paper presents an experimental demonstration of a data-driven control system (DCS) designed for the MIT Graphite Exponential Pile (MGEP). The DCS aims to regulate the neutron flux profile such that symmetry is preserved. Neutron flux perturbations are introduced into the MGEP to test the DCS's capabilities by the movement of an initiating control rod (ICR). To realize this functionality, a control system that relies on an artificial neural network (ANN) was developed, and then demonstrated on the MGEP. A Helium-3 ( 3 He) neutron detector and dual control rods, including their moving mechanisms, were fabricated. The perturbed flux profile was monitored by the moving neutron detector. The prediction accuracy of the neural network (NN) was examined and the DCS response was presented. Our results show that neural network regression model trained by experimental data can achieve a prediction error of less than 2.5 cm with a 95% confidence interval. The demonstration experiment also shows that a perturbation of the ICR can be captured by the control system and flux symmetry can be maintained within 1% after the response of the responding control rod (RCR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental analysis of gas dynamics in the reactor cavity section of a High-Temperature Gas-Cooled Reactor during an accident scenario

Here, this study investigates the behavior of a High-Temperature Gas-Cooled Reactor (HTGR) during a break of the helium pressure boundary event. Understanding the gas dynamics that occur during a break could help develop safety systems that reduce the probability of air entering the reactor core. To achieve this objective, experimental studies were conducted in a scaled-down HTGR experimental facility to provide information on the air-helium gas mixture within the confinement building and the impact of the ventilation system on the helium/air gas concentration following the depressurization event. The study evaluated different configurations, including active ventilation time scales, break sizes, and locations. The analysis of the active ventilation time revealed that a ventilation time of 22 seconds produced positive results, and smaller break sizes resulted in longer depressurization times, which improved the ventilation process. The orientation and elevation of the breaks had little effect on the oxygen concentration in the cavity but did impact the gas velocities.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermophysical Properties of NaCl–UCl 3 –PuCl 3 Molten Salts: A Combined Computational and Experimental Study

Actinide-bearing molten salts for use as fuels are an essential part of next generation molten salt reactors. Yet, numerous multicomponent salt mixtures are underdeveloped or have not been investigated. Here, this study, based on a combination of experimental and modeling techniques, is dedicated to determining and understanding a variety of properties of the ternary system of NaCl–UCl 3 –PuCl 3 , which represents a scenario for burnup of NaCl–UCl 3 fuel, at two compositions (∼10 and 5 mol % PuCl 3 in eutectic NaCl–UCl 3 pseudobinary) and a range of temperatures. Evaluation of the heat flow and mass loss data showed the 0.61NaCl–0.30UCl 3 –0.09PuCl 3 salt had a melting temperature of 551 ± 5 °C. Two additional thermal effects were observed occurring at approximately 410 and 494 °C. The transition occurring at 410 °C may be due to the presence of oxide in the salt. Extrapolation of thermodynamic data indicates the transition occurring at 494 °C is due to the formation of a liquid phase. Experimental testing determined the density of this system is a linear function of temperature and can be represented by the equation ρ = 4.014–0.0010T(°C), R 2 = 0.992. Additionally, by using atomistic modeling, we found that increasing the PuCl 3 content from 5 to 10 mol % led to the formation of larger Pu 3+ clusters and slower transport of ions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗