Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Solar Electric Propulsion (SEP) Tug Power System Considerations

Solar electric propulsion (SEP) technology is truly at the "intersection of commercial and military space" as well as the intersection of NASA robotic and human space missions. Building on the use of SEP for geosynchronous spacecraft station keeping, there are numerous potential commercial and military mission applications for SEP stages operating in Earth orbit. At NASA, there is a resurgence of interest in robotic SEP missions for Earth orbit raising applications, 1-AU class heliocentric missions to near Earth objects (NEOs) and SEP spacecraft technology demonstrations. Beyond these nearer term robotic missions, potential future human space flight missions to NEOs with high-power SEP stages are being considered. To enhance or enable this broad class of commercial, military and NASA missions, advancements in the power level and performance of SEP technologies are needed. This presentation will focus on design considerations for the solar photovoltaic array (PVA) and electric power system (EPS) vital to the design and operation of an SEP stage. The engineering and programmatic pros and cons of various PVA and EPS technologies and architectures will be discussed in the context of operating voltage and power levels. The impacts of PVA and EPS design options on the remaining SEP stage subsystem designs, as well as spacecraft operations, will also be discussed.

Kerslake, Thomas W.↗

RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes

In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM 50 /ft 2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kW STC ); 7. 2-4 bedrooms, 1,100-1,700 ft 2 . The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $|$$377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $\$$337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $\$$458; the lowest was $\$$171.

14 SOLAR ENERGY↗

Grid-Integrated Electric Mobility Model (GEM) v1.0

Transportation is the fastest-growing source of greenhouse gas (GHG) emissions and energy consumption globally. The convergence of shared mobility, vehicle automation, and electrification has the potential to drastically reduce transportation impacts, but requires careful integration with rapidly evolving electricity systems. We have developed the GEM Model (Grid-Integrated Electric Mobility) to examine these interactions with a U.S.-wide simulation framework encompassing private electric vehicles (EVs); shared automated EVs (SAEVs); charging infrastructure; controlled EV charging; and a grid economic dispatch model to simulate mobility futures exclusively using EVs. We find that an SAEV fleet 9% the size of today's active vehicles can satisfy trip demand with only 2.6 million chargers (0.2 per EV). Controlled EV charging can also reduce electricity demand variability, significantly reducing GHG emissions and decreasing solar curtailment by about one-third. While private EVs with uncontrolled charging would reduce GHG emissions by 53% compared to gasoline vehicles, SAEVs could achieve a 70% reduction.

Sheppard, Colin↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reference Model for Distribution Grid Control in the 21st Century

Intensive changes in the structure of the grid due to the penetration of new technologies, coupled with changing societal needs are outpacing the capabilities of traditional grid control systems. The gap is widening at an accelerating rate with the biggest impacts occurring at the distribution level due to the widespread adoption of diverse distribution-connected energy resources (DER) . This paper outlines the emerging distribution grid control environment, defines the new distribution control problem, and provides a distribution control reference model. The reference model offers a schematic representation of the problem domain to inform development of system architecture and control solutions for the high-DER electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research, Development and Demonstration of Peak Load Reduction on Distribution Feeders Using Distributed Energy Resources for the City of Fort Collins

This project titled “Research, Development and Demonstration of Peak Load Reduction on Distribution Feeders Using Distributed Energy Resources for the City of Fort Collins” evolved in response to the Department of Energy’s (DOE) Funding Opportunity Announcement (FOA) Number DE-PS26-07NT43119. Also referred to as the Fort Collins Renewable and Distributed System Integration (RDSI) Project, the effort was undertaken by a diverse group of local government, higher education and business organizations; and was driven by three overarching goals: I. Fulfill the requirements of the DOE FOA’s Area of Interest 2: Renewable and Distributed System Integration; most notably, to demonstrate the ability to reduce electric system distribution feeder peak load by 15% or more through the coordinated use of Distributed Energy Resources (DER). II. Advance the expertise, technologies and infrastructure necessary to support the long term vision of the Fort Collins Zero Energy District (FortZED) and move towards creating a zero energy district in the Fort Collins “Old Town” area. III. Further the goals of the City of Fort Collins Energy Policy, including the development of a Smart Grid-enabled distribution system in Fort Collins, expanded use of renewable energy, increased energy conservation, and peak load reduction. Through the collaborative efforts of the partner organizations, the Fort Collins RDSI project was successful in achieving all three of these goals. This report is organized into two distinct sections corresponding to the two phases of the project: • Part 1: Feeder Peak Load Reduction and the FortZED Initiative. • Part 2: Forming and Operating Utility Microgrids and Managing Load and Production Variability The original project scope addressed the Part 1 feeder peak load reduction. That work took place from 2009 through 2011 and was largely complete when the project scope was amended to include a demonstration of microgrid operations. While leveraging the assets, partner relationships, and lessons learned from Part 1, Part 2 was managed and executed as a distinct and substantially independent sub-project during the spring and summer of 2013. Both Parts 1 and 2 of the overall RDSI project can be viewed as cohesive stand-alone bodies of work and are presented as such within this report. In addition to the narratives, this document includes two Appendices that were compiled to supplement information about the various aspects of activities performed during Parts 1 and 2 of the project. Moreover, these Appendices are organized (as outlined below) so as to directly relate to the narratives in Part 1 and 2 of this report. • Appendix - Part 1: describes the roles of each project participant in regards to the feeder peak load reduction effort, and • Appendix - Part 2: deals with the microgrid research/demonstration.

14 SOLAR ENERGY↗

Cost of Saving Electricity Through Efficiency Programs Funded by Customers of Publicly Owned Utilities: 2012–2017

This report finds that energy efficiency programs for customers of publicly owned utilities saved electricity at an average cost of 2.4 cents per kilowatt-hour (kWh) from 2012 to 2017. Utilities use such cost performance metrics to assess effectiveness of efficiency program portfolios, determine what programs to offer customers, and, more broadly, ensure electricity system reliability at the most affordable cost as part of electric utility resource adequacy planning and resource procurement processes. The study analyzed efficiency program data reported by 111 program administrators for 219 publicly owned utilities in 14 states — about 90 percent of the municipal utilities and public utility districts that report the data to the Energy Information Administration (EIA). The data represent 88 percent of all spending and 75 percent of all savings that publicly owned utilities reported to EIA in those years. Berkeley Lab used data from several sources, including data provided directly by American Public Power Association members, publicly available annual reports and regional data collections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An analysis of propulsion options for transport of lunar materials to earth orbit

This paper describes the results of analyses of space-based transportation systems for the transport of extraterrestrial materials from their point of origin on the lunar surface to final delivery point in earth orbit and transport of equipment and supplies for extraterrestrial processing to the operational site. The emphasis has been on the use of near-term (pre-year 2000) propulsion systems, such as advanced chemical (H2, O2) and nuclear-electric systems. More exotic systems (mass drivers, nuclear-thermal rockets, etc.) were also considered to evaluate the potential to be gained by use of post-year 2000 technologies. Finally, the effects of using extraterrestrial propellants (e.g., H2 from lunar polar water-ice for chemical systems) were compared to those of propulsion systems deriving all or part of their propellants from the earth.

Frisbee, R. H.↗

Vector Lyapunov Functions for Stochastic Interconnected Systems

Theoretical paper presents set of sufficient conditions for asymptotic and exponential stability with probability 1 for class of stochastic interconnected systems. Theory applicable to complicated, large-scale mechanical or electrical systems, and, for several design problems, it reduces computational difficulty by relating stability criteria to fundamental structural features of system.

Boussalis, D.↗

Polyimide/Glass Composite High-Temperature Insulation

Lightweight composites of RP46 polyimide and glass fibers have been found to be useful as extraordinarily fire-resistant electrical-insulation materials. RP46 is a polyimide of the polymerization of monomeric reactants (PMR) type, developed by NASA Langley Research Center. RP46 has properties that make it attractive for use in electrical insulation at high temperatures. These properties include high-temperature resistance, low relative permittivity, low dissipation factor, outstanding mechanical properties, and excellent resistance to moisture and chemicals. Moreover, RP46 contains no halogen or other toxic materials and when burned it does not produce toxic fume or gaseous materials. The U. S. Navy has been seeking lightweight, high-temperature-resistant electrical-insulation materials in a program directed toward reducing fire hazards and weights in ship electrical systems. To satisfy the requirements of this program, an electrical-insulation material must withstand a 3-hour gas-flame test at 1,600 F (about 871 C). Prior to the development reported here, RP46 was rated for use at temperatures from -150 to +700 F (about -101 to 371 C), and no polymeric product - not even RP46 - was expected to withstand the Navy 3-hour gas-flame test.

Pater, Ruth H.↗

NASA Marshall Space Flight Center In-Space Cryogenic Propulsion Capabilities and Applications to Human Exploration

The current focus on lunar exploration and future human missions to Mars is driving in-space propulsion system requirements toward higher performance cryogenic systems with long-duration storage and operational capabilities. Not only do these systems offer higher performance than storable propellant options, but they also enable the potential for in-situ propellant production. Future Mars transit systems are envisioned to utilize either high-thrust nuclear thermal propulsion (with liquid hydrogen propellant), or hybrid systems with both cryogenic chemical systems (likely LOX/CH 4 ) for high acceleration manoeuvres and nuclear electric systems for long duration high Isp manoeuvres. Exploration architectures based on either of these options require the use of high-performance cryogenic propellants with long-duration storage capabilities for both in-space transportation as well as planetary descent and ascent functions. Current efforts focusing on lunar exploration also rely on cryogenic propellants (either LOX/LCH 4 or LOX/LH 2 ) for lunar transit and descent/ascent transportation functions. In-space cryogenic propulsion systems pose numerous technology challenges with respect to long-duration propellant storage and usage, including advanced insulation, tank stratification and pressure management, cryogenic refrigeration to reduce propellant loss through boil off, low leakage cryogenic valves, low temperature liquid acquisition, and cryogenic propellant transfer. NASA has invested in technology development efforts, demonstrating individual technologies and systems-level operations. NASA Marshal Space Flight Center has also invested in multiple test facilities and modular test rigs that allow ground demonstration of numerous integrated technologies and systems concepts of operations. Additional investments have been made to mature analytical capabilities and design tools. These capabilities (both test/demonstration & engineering design/analysis) are available to support both internal efforts and industrial partners in the development of exploration and science mission systems. With this increased interest, it is critical to understand the current state of in-space cryogenic propulsion technology, determine risks to its successful application to human exploration, and prepare the engineering, test, and evaluation capabilities to support the ambitious plans for future systems. This paper provides a survey of recent developments in in-space cryogenic propulsion and cryogenic propellant management technologies, as well as facilities and engineering/analytical capabilities ready to support current and future exploration efforts.

Cryogenic propulsion↗

NASA Marshall Space Flight Center In-Space Cryogenic Propulsion Capabilities and Applications to Human Exploration

The current focus on lunar exploration and future human missions to Mars is driving in-space propulsion system requirements toward higher performance cryogenic systems with long-duration storage and operational capabilities. Not only do these systems offer higher performance than storable propellant options, but they also enable the potential for in-situ propellant production. Future Mars transit systems are envisioned to utilize either high-thrust nuclear thermal propulsion (with liquid hydrogen propellant), or hybrid systems with both cryogenic chemical systems (likely LOX/CH 4 ) for high acceleration manoeuvres and nuclear electric systems for long duration high Isp manoeuvres. Exploration architectures based on either of these options require the use of high-performance cryogenic propellants with long-duration storage capabilities for both in-space transportation as well as planetary descent and ascent functions. Current efforts focusing on lunar exploration also rely on cryogenic propellants (either LOX/LCH 4 or LOX/LH 2 ) for lunar transit and descent/ascent transportation functions. In-space cryogenic propulsion systems pose numerous technology challenges with respect to long-duration propellant storage and usage, including advanced insulation, tank stratification and pressure management, cryogenic refrigeration to reduce propellant loss through boil off, low leakage cryogenic valves, low temperature liquid acquisition, and cryogenic propellant transfer. NASA has invested in technology development efforts, demonstrating individual technologies and systems-level operations. NASA Marshal Space Flight Center has also invested in multiple test facilities and modular test rigs that allow ground demonstration of numerous integrated technologies and systems concepts of operations. Additional investments have been made to mature analytical capabilities and design tools. These capabilities (both test/demonstration & engineering design/analysis) are available to support both internal efforts and industrial partners in the development of exploration and science mission systems. With this increased interest, it is critical to understand the current state of in-space cryogenic propulsion technology, determine risks to its successful application to human exploration, and prepare the engineering, test, and evaluation capabilities to support the ambitious plans for future systems. This paper provides a survey of recent developments in in-space cryogenic propulsion and cryogenic propellant management technologies, as well as facilities and engineering/analytical capabilities ready to support current and future exploration efforts.

Cryogenic propulsion↗

Demolition of the K-27 Building at the East Tennessee Technology Park (ETTP) - 17423

On February 8, 2016, URS - CH2M Oak Ridge LLC (UCOR) initiated the demolition of the East Tennessee Technology Park's (ETTP's) final gaseous diffusion building in DOE's Oak Ridge Environmental Management program. Building K-27 was a 35,582 m{sup 2} (383,000 ft{sup 2}) gaseous diffusion building that contained approximately 92,903 m{sup 2} (1 million ft{sup 2}) of floor space. It was one of five gaseous diffusion buildings at the site, formerly known as the Oak Ridge Gaseous Diffusion Plant. The actual demolition of this facility took approximately seven months to complete; however, planning and preparation took more than three years. The deactivation process was a critical element in preparing the building for demolition. UCOR's K-27 deactivation activities began in April 2012 with the installation of safe walking paths and fall protection systems to allow safe work access. Next, all mechanical and electrical systems associated with the facility were shut down and isolated, a process known as 'cold and dark.' More than 19.3 km (12 mi) of process piping and components were marked and measured. Additionally, workers performed nondestructive assay (NDA) and vent-purge-and-drain activities and applied foam to piping and components as needed [1]. Based on characterization results, approximately 4.8 km (3 mi) of process piping, and 372 converters and compressors were removed and shipped offsite prior to demolition. Lower-hazard materials and equipment were demolished with the building structure and transported to onsite disposal facilities. Upfront waste characterization and ongoing monitoring were key to the successful disposal of demolition debris at onsite facilities. Due to process improvements in waste loading recommended by work crews, the project achieved a 50 percent improvement in the daily hauling rate during the 9,000-truckload shipping campaign. Crews worked in high-risk, high-hazard conditions and were exposed to radiological and chemical contaminants, extreme temperatures, and deteriorating infrastructure. However, the hazard controls that were put in place, based on the Integrated Safety Management System (ISMS) walk-downs and hazard determination, made the effort manageable. The overall safety performance during demolition of the facility was excellent, with no significant injuries, and exceeded industry standards and DOE target levels. Outstanding safety performance was a testament to the dedication of the workforce, given the significant hazards presented by the demolition of the Hazard Category 2 nuclear facility. Another key element to the success of the K-27 demolition was the support and approval of all stakeholders involved in this effort, including DOE, the surrounding communities, the State of Tennessee, the UCOR management team, and, most importantly, the workforce that performed this highly hazardous work. This $52 million demolition project was completed ahead of schedule with no significant injuries and in compliance with all DOE orders, site procedures, and environmental controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

13kW Advanced Electric Propulsion Flight System Development and Qualification

The next phase of robotic and human deep space exploration missions requires high performance, high power solar electric propulsion systems for large-scale science missions and cargo transportation. Aerojet Rocketdyne's Advanced Electric Propulsion System (AEPS) program is completing development and qualification of a 13kW flight EP system to support NASA exploration. The first use of the AEPS is planned for the NASA Power & Propulsion Element, which is the first element of NASA's cis-lunar Gateway. The flight AEPS system includes a magnetically shielded long-life Hall thruster, power processing unit (PPU), and xenon flow controller (XFC). The Hall thruster, originally developed and demonstrated by NASA's Glenn Research Center and the Jet Propulsion Laboratory, operates at input powers up to 13.3kW while providing a specific impulse over 2600s at an input voltage of 600V. The power processor is designed to accommodate an input voltage range of 95 to 140V, consistent with operation beyond the orbit of Mars. The integrated system is continuously throttleable between 3 and 13.3kW. The program has completed testing of the Technology Development Units and is progressing into the Engineering Development Unit test phase and the final design phase to Critical Design Review (CDR). This paper will present the high power AEPS system capabilities, overall program and design status and the latest test results for the 13kW flight system development as well as the plans for the development and qualification effort of the EP string.

in-space propulsion↗

A dynamic solar-electric power/thermal control system for spacecraft.

This paper describes a solar-electric power and active thermal control system for spacecraft with solar energy to electricity conversion efficiency of more than 20%. Briefly, the solar heat energy is absorbed by flat plate collectors yielding above 70% of the energy incident for conversion by an organic condensing cycle. The cycle operates between 132 and 6.67 deg C. The working fluid is F-114 which flows through a solar collector to absorb heat, then through a regenerator and into the radiator where it is condensed to a liquid. The cold liquid flows through two paths, one providing regenerator cooling, the other providing spacecraft thermal control. The system total weight is about 170kg/kW of electrical energy produced. The dynamic system replaces batteries by a thermal capacitor for eclipse period energy storage, thereby eliminating many battery charging and control problems as well as improving efficiency and weight characteristics of the system.

Davis, B. K.↗

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗