Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enhanced Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Effects of Molecular Weight on poly( -pentadecalactone) Mechanical and Thermal Properties

A series of poly({omega}-pentadecalactone) (PPDL) samples, synthesized by lipase catalysis, were prepared by systematic variation of reaction time and water content. These samples possessed weight-average molecular weights (M{sub w}), determined by multi-angle laser light scattering (MALLS), from 2.5 x 10{sup 4} to 48.1 x 10{sup 4}. Cold-drawing tensile tests at room temperature of PPDL samples with M{sub W} between 4.5 x 10{sup 4} and 8.1 x 10{sup 4} showed a brittle-to-ductile transition. For PPDL with M{sub W} of 8.1 x 10{sup 4}, inter-fibrillar slippage dominates during deformation until fracture. Increasing M{sub W} above 18.9 x 10{sup 4} resulted in enhanced entanglement network strength and strain-hardening. The high M{sub W} samples also exhibited tough properties with elongation at break about 650% and tensile strength about 60.8 MPa, comparable to linear high density polyethylene (HDPE). Relationships among molecular weight, Young's modulus, stress, strain at yield, melting and crystallization enthalpy (by differential scanning calorimetry, DSC) and crystallinity (from wide-angle X-ray diffraction, WAXD) were correlated for PPDL samples. Similarities and differences of linear HDPE and PPDL molecular weight dependence on their mechanical and thermal properties were also compared.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanistic Insights Into Fatigue Life Enhancement of High‐Strength Steel via Ultrasonic Impact Treatment

In this work we explore the impact of Ultrasonic Impact Treatment (UIT) on the fatigue performance of high‐strength microalloyed steel commonly used in crankshaft applications. Building on prior observations of fatigue life improvement with UIT, this work focuses on unraveling the process–structure–performance relationships underpinning these enhancements. Microstructural analysis revealed significant grain refinement in the near‐surface layers, with deformation depth increasing at higher impact energies. This led to increased surface hardness and the development of deeper compressive residual stresses, particularly in samples treated with higher impact energy. Rotating bending fatigue testing showed a substantial improvement in fatigue life for UIT‐treated samples, with the endurance limit nearly doubling compared with untreated specimens. Fractographic analysis revealed a transition in crack initiation from surface defects in untreated samples to interior regions in UIT‐treated samples, characterized by the formation of noninclusion‐induced granular bright facets (GBFs). The observed fatigue enhancement is attributed to the synergistic effects of strain hardening and compressive residual stresses, which increase the surface crack threshold and promote interior crack initiation. This study provides new mechanistic insight into UIT‐induced fatigue resistance and interior failure behavior in high‐strength steels.

36 MATERIALS SCIENCE↗

Effect of NaOH Concentration and Adding Sequences on Structural and Magnetic Properties of Ni{sub 0.4}Co{sub 0.6}Fe{sub 2}O{sub 4} Nanopowders Prepared Via Co-precipitation Route

Ni{sub 0.4}Co{sub 0.6}Fe{sub 2}O{sub 4} nanopowders were prepared via the co-precipitation route followed by annealing treatment. The structural and magnetic properties of the as-synthesized samples were determined by XRD, FT-IR, TG-DSC, and PPMS measurements, respectively. The XRD patterns indicated a single-phase cubic spinel structure for all the Ni-Co ferrite samples, regardless of adding sequences of the reactants or NaOH concentration. The analysis of the XRD patterns revealed that the enhancement in lattice constant with increasing NaOH concentration is related to the prevention of oxidization of Co{sup 2+} ions in the Ni-Co ferrite lattice. The FT-IR spectra indicated that samples prepared in the B process have fewer impurities than those prepared in the A process. The enhancement in saturation magnetization with the increase in sodium hydroxide concentration could be attributed to the strengthening of super-exchange interaction between A and B sublattices, due to replacements of Co{sup 3+} ions (magnetic moment of 0 μ{sub B}) by Co{sup 2+} ions (magnetic moment of 3 μ{sub B}) at B sublattices. The obvious increase in the coercivity field with the increase in concentration of NaOH solutions can be interpreted in terms of enhancement of magneto-crystalline anisotropy that originated from gradual substitutions of Co{sup 3+} ions with Co{sup 2+} ions at the octahedral sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phosphate-Induced Immobilization of Uranium in Hanford Sediments

Phosphate can be added to subsurface environments to immobilize U(VI) contamination. The efficacy of immobilization depends on the site-specific groundwater chemistry and aquifer sediment properties. Batch and column experiments were performed with sediments from the Hanford 300 Area in Washington State and artificial groundwater prepared to emulate the conditions at the site. Batch experiments revealed enhanced U(VI) sorption with increasing phosphate addition. X-ray absorption spectroscopy measurements of samples from the batch experiments found that U(VI) was predominantly adsorbed at conditions relevant to the column experiments and most field sites (low U(VI) loadings, <25 μM), and U(VI) phosphate precipitation occurred only at high initial U(VI) (>25μM) and phosphate loadings. While batch experiments showed the transition of U(VI) uptake from adsorption to precipitation, the column study was more directly relevant to the subsurface environment because of the high solid:water ratio in the column and the advective flow of water. In column experiments, nearly six times more U(VI) was retained in sediments when phosphate-containing groundwater was introduced to U(VI)-loaded sediments than when the groundwater did not contain phosphate. This enhanced retention persisted for at least one month after cessation of phosphate addition to the influent fluid. Sequential extractions and laser-induced fluorescence spectroscopy of sediments from the columns suggested that the retained U(VI) was primarily in adsorbed forms. These results indicate that in situ remediation of groundwater by phosphate addition provides lasting benefit beyond the treatment period via enhanced U(VI) adsorption to sediments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced thermoelectric performance in Cd doped CuInTe{sub 2} compounds

CuIn{sub 1−x}Cd{sub x}Te{sub 2} materials (x = 0, 0.02, 0.05, and 0.1) are prepared using melting-annealing method and the highly densified bulk samples are obtained through Spark Plasma Sintering. The X-ray diffraction data confirm that nearly pure chalcopyrite structures are obtained in all the samples. Due to the substitution of Cd at In sites, the carrier concentration is greatly increased, leading to much enhanced electrical conductivity and power factor. The single parabolic band model is used to describe the electrical transport properties of CuInTe{sub 2} and the low temperature Hall mobility is also modeled. By combing theoretical model and experiment data, the optimum carrier concentration in CuInTe{sub 2} is proposed to explain the greatly enhanced power factors in the Cd doped CuInTe{sub 2}. In addition, the thermal conductivity is reduced by extra phonon scattering due to the atomic mass and radius fluctuations between Cd and In atoms. The maximum zTs are observed in CuIn{sub 0.98}Cd{sub 0.02}Te{sub 2} and CuIn{sub 0.9}Cd{sub 0.1}Te{sub 2} samples, which are improved by over 100% at room temperature and around 20% at 600 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Shear Properties for APO/MBI Syntactic Foam

Triaxial compression testing is a means for mechanical characterization of a material. A unique feature of the triaxial compression test is the application of two different magnitudes of compressive pressures on the material simultaneously. The material behavior under these different compressive pressures can be monitored over time. Several important characteristics of the material, such as stress yield values and the shear failure envelope may then be determined. Also mechanical properties such as Poisson’s ratio, Young’s modulus and bulk modulus can be determined from the triaxial compression test. The triaxial compression test was employed in this investigation to characterize the shear behavior, shear failure envelope, and mechanical properties of a syntactic foam. Los Alamos National Laboratory (LANL) supplied a total of 36 samples of APO-BMI syntactic foam to the University of New Mexico, Department of Civil Engineering for testing between December 2003 and May 2004. Each sample had a diameter of 1.395±0.005 in. (3.543±0.013cm.) and a length of 2.796±0.004 in. (7.102±0.010 cm.). The samples had an average density of 0.295 g/cm3. Additional information about the material tested in this investigation can be found in the “Specimen Description” section contained in Chapter 1. The nomenclatures used in this study is presented in Chapter 1. In addition to designing and implementing triaxial compression tests capable of up to 2,000 psi. confining pressure (minor principal stress) and roughly 13,000 psi. in axial pressure (major principal stress), a pure tension test was designed and conducted on the foam material. The purpose of this pure tension test was to obtain maximum tensile stress values to enhance the characterization of the shear envelope in the stress space. The sampling procedure and specimen preparation for a standard test can be found in the American Society for Testing Materials (ASTM) D 5379/ D 5379 – 93. The above tests mentioned and their procedures are discussed in Chapter 2. Chapter 2 contains the types of tests performed and the apparatus used for testing the material. Chapter 2 also has a brief explanation of the equipment and the procedures used for conducting the tests. In Chapter 3, the material characteristics and mechanical properties obtained from the tests are described; composite plots of deviatoric vs. mean stress and deviatoric stress vs. longitudinal strain are also included. The plots of deviatoric stress vs. mean stress clearly identify the shear envelope for the material. Chapter 4 summarizes the vital information obtained from the tests and the conclusions made. All the necessary plots and the data generated during the testing have been included in the Appendix. The information in the appendix includes plots of: Strain vs. Time, Stress vs. Time, Stress vs. Strain, Mean Stress vs. Volumetric Strain, Lateral Strain vs. Longitudinal Strain, and q vs. p. Bulk modulus, Poisson’s ratio, and Young’s modulus are displayed in the appropriate plots in each appendix.

36 MATERIALS SCIENCE↗

Are young stars always associated with cold massive disks? A CO and millimeter interferometric continuum survey

The results of a combined millimeter-spectral-line and continuum survey of cold far-infrared sources selected to favor embedded young stars in the Galaxy are presented. The spectral-line observations were performed with the 5 meter antenna of the University of Texas Millimeter-Wave Observatory. High resolution continuum observations were obtained with the Owens Valley (OVRO) Millimeter-Wave Interferometer. The goal of the survey was to gain insight into the mass, temperature, and distribution of cold dust which envelopes stars during the earliest stages of their evolution. The first phase of our survey involved 1.2 arcmin resolution observations of CO-12 and CO-13 emission lines toward each source. All but two sources had detectable CO emission. We found that 40% of the sources appear to be associated with star formation as evidenced by the presence of enhanced CO-12 line widths or broad wings. At least five of these objects are associated with bipolar molecular outflows. The second phase of our survey involves high resolution 2.7 mm continuum observations with 3 interferometer baselines ranging from 15 to 55 m in length. Preliminary results indicate that about 25% of the sources in our sample have detectable continuum emission on scales less than 30 arcsec. The high percentage of sources with enhanced CO-12 line widths or broad wings indicates that a significant fraction of our samples, 40%, are likely to be young stars. The lower detection percentage in the continuum observations, 25%, suggest that such objects are not always surrounded by large concentrations of gas and dust. The continuum detection percentage for actual dust emission could be lower than that given above since emission from ionized gas could be responsible for the observed 2.7 mm emission in some objects. To get an understanding of the type of object detected in our survey, a map of one of the survey sources, L1689N, has been made using the OVRO mm interferometer.

Mundy, L. G.↗

An innovative accident tolerant LWR fuel rod design based on uranium-molybdenum metal alloy

The US Department of Energy is developing a uranium-molybdenum metal alloy Enhanced Accident Tolerant Fuel concept for Light Water Reactor applications that provides improved fuel performance during normal operation, anticipated operational occurrences, and postulated accidents. The paper is organized as follows. First, an overview of the design features of the U-Mo fuel concept is summarized, including the key attributes and technical challenges to be addressed through the research and development program. Second, recent results are provided on the triple extrusion of a depleted U-Mo fuel rodlet with a niobium liner and SS-316 cladding. A status is presented next on the high temperature water corrosion testing of short samples with pre-drilled cladding defects. Lastly, an assessment of the enhanced accident tolerance features is discussed that highlights the key performance attributes of the U-Mo fuel rod design. Scoping calculations have identified that the reduced stored energy of the U-Mo fuel at the initiation of a LOCA event may reduce core temperatures below 500-600 Celsius degrees during the early phase of the LOCA event. These preliminary evaluations find that the U-10Mo fuel design concept has many beneficial features that can meet or improve conventional LWR fuel performance requirements under normal operation, anticipated operational occurrences (AOOs) and postulated accidents.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A PCR Based Microbial Monitoring Alternative Method of Detection and Identification of Microbes Aboard ISS

Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS) with additional introduction of new microflora occurring with every exchange of crew or addition of equipment and supplies. These microbes are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). As this can be detrimental to astronaut health and optimal performance of ISS systems, monitoring of systems such as ECLSS to include identification of microbial contaminants could prevent adverse effects on human health and life support systems. Current monitoring on ISS is laborious and utilizes culture based methods followed by sample return to Earth for complete analysis. Future, long-distance spaceflight missions will require real-time monitoring capabilities that enable efficient and rapid assessments of the microbial environment allowing for expedited decisions and more targeted response to cope with anomalies. Polymerase chain reaction (PCR), a molecular microbial monitoring method was chosen and numerous PCR instruments investigated for their potential to perform in microgravity conditions. Using ISS as a test bed for PCR verification in microgravity will enable NASA to assess whether molecular based microbiological sensors may be components of reliable, closed-loop life support and habitation systems in spacecraft, enhancing infrastructure capabilities through increased efficiency, reliability, and time savings by enabling sample analysis on orbit. NASA selected the Water Monitoring Suite as one of the rapid spaceflight hardware demonstration activities utilizing a streamlined process to minimize the time required to fly experimental flight hardware. The RAZOR EX (BioFire Defense, Salt Lake City, UT) system was part of the water monitoring suite and is a commercial off-the-shelf (COTS) real-time PCR instrument designed for field work. The RAZOR EX was originally designed for Department of Defense (DoD) under a small business innovative research (SBIR) grant and is ruggedized, compact and provides a rapid, sample to answer in less than an hour. PCR assays using a fluorescent probe were optimized and spiked with known concentrations of DNA (Pseudomonas aeruginosa) ranging from 0.002 to 20 ng. PCR reagents were lyophilized and configured in customized pouches and tested for flight readiness. Three types of water were used to rehydrate the reagents and demonstrate the fidelity of the PCR reaction in microgravity. Molecular grade deionized water served as a control while filtered and unfiltered ISS potable water served to test for chemical or biological inhibitors. All three types were compared to parallel ground test results. Nine tests were run on ISS (3 of each water type) and the critical threshold cycle (Ct) was compared to parallel ground tests completed at Kennedy Space Center, FL and Johnson Space Center, TX. All concentrations of Pseudomonas aeruginosa DNA were detected. A comparison of the Ct produced in real time PCR indicated similarity between flight and ground samples. There appeared to be no significant difference between flight or ground PCR reactions or between any of the three water types. This testing demonstrated the ability to perform molecular testing during spaceflight operations with similar sensitivity. It will allow for future ground development of molecular protocols and minimize the need for spaceflight testing. Future testing will include development of additional targets including environmental and health related organisms.

Christina Khodadad↗

Absorption of Solar Radiation by the Cloudy Atmosphere: Further Interpretations of Collocated Aircraft Measurements

We have extended the interpretations made in two prior studies of the aircraft shortwave radiation measurements that were obtained as part of the Atmospheric Radiation Measurements (ARM) Enhanced Shortwave Experiments (ARESE). These extended interpretations use the 500 nm (10 nm bandwidth) measurements to minimize sampling errors in the broadband measurements. It is indicated that the clouds present during this experiment absorb more shortwave radiation than predicted by clear skies and thus by theoretical models, that at least some (less than or equal to 20%) of this enhanced cloud absorption occurs at wavelengths less than 680 nm, and that the observed cloud absorption does not appear to be an artifact of sampling errors nor of instrument calibration errors.

Cess, R. D.↗

Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical/mineralogical makeup of organic host phases to help determine deposition and preservation factors. (4) Chemical Stratigraphy Analyze the fine spatial distribution and variation of key species with depth.

Mars↗

Surface spins enhanced magnetoelectric coefficient and impedance spectroscopy of BaFe{sub 0.01}Ti{sub 0.99}O{sub 3} and BaFe{sub 0.015}Ti{sub 0.985}O{sub 3} nanorods

Highlights: • Multiferroic Fe-doped BaTiO{sub 3} nanorods. • Sol–gel. • Magnetoelectric coefficient. • Transmission electron microscopy. • Cole–Cole plots. - Abstract: Multiferroic BaFe{sub 0.01}Ti{sub 0.99}O{sub 3} (BFT1) and BaFe{sub 0.015}Ti{sub 0.985}O{sub 3} (BFT15) nanorods were prepared by a sol–gel synthesis and annealed at 700 °C/2 h. The tetragonal phase and nano dimensions of BFT samples are identified by X-ray diffraction and transmission electron microscopy. The enhancement in ferroelectricity depends upon low porosity, tetragonal phase, space charge field, larger surface area and oriented growth. The ferromagnetism depends upon partially filled inner shells, surface spins and oxygen vacancies. The magnetoelectric coefficient is explained on the basis of surface spins, short-range interactions near surface boundary, compressive stress and twin structure contributed by nano grains which can reside stress near grain boundaries. The frequency dependent real (Z′) and imaginary (Z″) parts of impedance spectra are confirmed by the variations that observed in dielectric properties. The values of resistance of grain boundaries, R{sub gb} is higher than grains, R{sub g} indicating that the effect of grain boundaries is dominant in BFT nanorods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Throughput Characterization and Optimization of Polyamide Hydrolase Activity Using Open Port Sampling Interface Mass Spectrometry

Enzymatic biodegradation of polymers, such as polyamides (PA), has the potential to cost-effectively reduce plastic waste, but enhancements in degradation efficiency are needed. Engineering enzymes through directed evolution is one pathway toward identification of critical domains needed for improving activity. However, screening such enzymatic libraries (100s-to-1000s of samples) is time-consuming. Here we demonstrate the use of robotic autosampler (PAL) and immediate drop on demand technology (I.DOT) liquid handling systems coupled with open-port sampling interface-mass spectrometry (OPSI-MS) to screen for PA6 and PA66 hydrolysis by 6-aminohexanoate-oligomer endo-hydrolase (nylon hydrolase, NylC) in a high-throughput (8–20 s/sample) manner. The OPSI-MS technique required minimal sample preparation and was amenable to 96-well plate formats for automated processing. Enzymatic hydrolysis of PA characteristically produced soluble linear oligomer products that could be identified by OPSI-MS. Incubation temperatures and times were optimized for PA6 (65 °C, 24 h) and PA66 (75 °C, 24 h) over 108 experiments. In addition, the I.DOT/OPSI-MS quantified production of PA6 linear dimer (8.3 ± 1.6 μg/mL) and PA66 linear monomer (13.5 ± 1.5 μg/mL) by NylC with a lower limit of detection of 0.029 and 0.032 μg/mL, respectively. For PA6 and PA66, linear oligomer production corresponded to 0.096 ± 0.018% and 0.204 ± 0.028% conversion of dry pellet mass, respectively. The developed methodology is expected to be utilized to assess enzymatic hydrolysis of engineered enzyme libraries, comprising hundreds to thousands of individual samples.

47 OTHER INSTRUMENTATION↗

Plant Growth-Promoting Bacteria for Phytostabilization of Mine Tailings

Eolian dispersion of mine tailings in arid and semiarid environments is an emerging global issue for which economical remediation alternatives are needed. Phytostabilization, the revegetation of these sites with native plants, is one such alternative. Revegetation often requires the addition of bulky amendments such as compost which greatly increases cost. We report the use of plant growth-promoting bacteria (PGPB) to enhance the revegetation of mine tailings and minimize the need for compost amendment. Twenty promising PGPB isolates were used as seed inoculants in a series of greenhouse studies to examine revegetation of an extremely acidic, high metal content tailings sample previously shown to require 15% compost amendment for normal plant growth. Several isolates significantly enhanced growth of two native species, quailbush and buffalo grass, in tailings. In this study, PGPB/compost outcomes were plant specific; for quailbush, PGPB were most effective in combination with 10% compost addition while for buffalo grass, PGPB enhanced growth in the complete absence of compost. Results indicate that selected PGPB can improve plant establishment and reduce the need for compost amendment. Further, PGPB activities necessary for aiding plant growth in mine tailings likely include tolerance to acidic pH and metals.

54 ENVIRONMENTAL SCIENCES↗

Resource Prospector Instrumentation for Lunar Volatiles Prospecting, Sample Acquisition and Processing

Data gathered from lunar missions within the last two decades have significantly enhanced our understanding of the volatile resources available on the lunar surface, specifically focusing on the polar regions. Several orbiting missions such as Clementine and Lunar Prospector have suggested the presence of volatile ices and enhanced hydrogen concentrations in the permanently shadowed regions of the moon. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was the first to provide direct measurement of water ice in a permanently shadowed region. These missions with other orbiting assets have laid the groundwork for the next step in the exploration of the lunar surface; providing ground truth data of the volatiles by mapping the distribution and processing lunar regolith for resource extraction. This next step is the robotic mission Resource Prospector (RP). Resource Prospector is a lunar mission to investigate 'strategic knowledge gaps' (SKGs) for in-situ resource utilization (ISRU). The mission is proposed to land in the lunar south pole near a permanently shadowed crater. The landing site will be determined by the science team with input from broader international community as being near traversable landscape that has a high potential of containing elevated concentrations of volatiles such as water while maximizing mission duration. A rover will host the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload for resource mapping and processing. The science instruments on the payload include a 1-meter drill, neutron spectrometer, a near infrared spectrometer, an operations camera, and a reactor with a gas chromatograph-mass spectrometer for volatile analysis. After the RP lander safely delivers the rover to the lunar surface, the science team will guide the rover team on the first traverse plan. The neutron spectrometer (NS) and near infrared (NIR) spectrometer instruments will be used as prospecting tools to guide the traverse path. The NS will map the water-equivalent hydrogen concentration as low as 0.5% by weight to an 80 centimeter depth as the rover traverses the lunar landscape. The NIR spectrometer will measure surficial H2O/OH as well as general mineralogy. When the prospecting instruments identify a potential volatile-rich area during the course of a traverse, the prospect is then mapped out and the most promising location identified. An augering drill capable of sampling to a depth of 100 centimeters will excavate regolith for analysis. A quick assay of the drill cuttings will be made using an operations camera and NIR spectrometer. With the water depth confirmed by this first auguring activity, a regolith sample may be extracted for processing. The drill will deliver the regolith sample to a crucible that will be sealed and heated. Evolved volatiles will be measured by a gas chromatograph-mass spectrometer and the water will be captured and photographed. RP is a solar powered mission, which given the polar location translates to a relatively short mission duration on the order of 4-15 days. This short mission duration drives the concept of operations, instrumentation, and data analysis towards critical real time analysis and decision support. Previous payload field tests have increased the fidelity of the hardware, software, and mission operations. Current activities include a mission level field test to optimize interfaces between the payload and rover as well as better understand the interaction of the science and rover teams during the mission timeline. This paper will include the current status of the science instruments on the payload as well as the integrated field test occurring in fall of 2015. The concept of operations will be discussed, including the real time science and engineering decision-making process based on the critical data from the instrumentation. The path to flight will be discussed with the approach to this ambitious low cost mission.

ISRU↗

Hot deformation induced defects and performance enhancement in FeSb{sub 2} thermoelectric materials

The effect of hot deformation induced defects and texture on thermoelectric properties of FeSb{sub 2} bulk crystals has been investigated. The transport properties of the samples along both parallel and perpendicular direction of pressing were measured from 3 K to 300 K. The results showed that thermal conductivity of the deformed samples was significantly reduced. After twice deformation, the thermal conductivity of the sample along the perpendicular direction of pressing was decreased to 4 W/mK, which was only one third of that before deformation. Transmission electron microscopy observation revealed the presence of high density of lattice defects in the deformed samples. The lattice thermal conductivity was analyzed using the Debye-Callaway approximation, and the results showed that the deformation induced lattice imperfections play an important role in enhancing phonon scattering. In addition, both the electrical resistivity and Seebeck coefficient exhibited a weak anisotropy in the deformed samples. The figure of merit ZT of the bulk FeSb{sub 2} was significantly improved from 0.010 to 0.021 after deformation.

36 MATERIALS SCIENCE↗

Core-shell structured α-Fe2O3@CeO2 heterojunction for the enhanced visible-light photocatalytic activity

Highlights: • CeO{sub 2}–coated α-Fe{sub 2}O{sub 3} sample was prepared via a hydrothermal route. • α-Fe{sub 2}O{sub 3}@CeO{sub 2} presented the excellent photocatalytic activity and stability. • The heterojunction interface facilitated the separation of electron-hole pairs. • Ce{sup 4+}/Ce{sup 3+} redox couple promoted the efficient electron transfer. - Abstract: CeO{sub 2}-coated α-Fe{sub 2}O{sub 3} nanoparticles (α-Fe{sub 2}O{sub 3}@CeO{sub 2}) with the enhanced photocatalytic activity were synthesized by a hydrothermal route and performed for the visible light driven photo-degradation of methylene blue (MB). The photocatalytic activity of α-Fe{sub 2}O{sub 3}@CeO{sub 2} is greatly affected by the thickness of CeO{sub 2} shell under the same conditions. The core-shell structured α-Fe{sub 2}O{sub 3}@CeO{sub 2} sample exhibited a narrower band gap energy in comparison to the pure α-Fe{sub 2}O{sub 3} and CeO{sub 2} bulks, leading to the excellent photocatalytic activity and stability for the degradation of MB under visible light irradiation after five cycle times. The core-shell structured α-Fe{sub 2}O{sub 3}@CeO{sub 2} sample presented higher degradation activity than that of the supported 8-Fe/CeO{sub 2} bulks with optimized α-Fe{sub 2}O{sub 3} loading of 8%. It can be ascribed to the Ce{sup 4+}/Ce{sup 3+} redox couple and the heterojunction interfaces of core-shell structured α-Fe{sub 2}O{sub 3}@CeO{sub 2} sample, which can promote the electrons transfer and restrain the photoexcited electron-hole recombination, leading to the excellent degradation activity under visible light irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗