Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A generalized a priori dose uncertainty model of IMRT delivery

Multileaf collimator-based intensity modulated radiation therapy (IMRT) is complex because each intensity modulated field consists of hundreds of subfields, each of which is associated with an intricate interplay of uncertainties. In this study, the authors have revised the previously introduced uncertainty model to provide an a priori accurate prediction of dose uncertainty during treatment planning in IMRT. In the previous model, the dose uncertainties were categorized into space-oriented dose uncertainty (SOU) and nonspace-oriented dose uncertainty (NOU). The revised model further divided the uncertainty sources into planning and delivery. SOU and NOU associated with a planning system were defined as inherent dose uncertainty. A convolution method with seven degrees of freedom was also newly applied to generalize the model for practical clinical cases. The model parameters were quantified through a set of measurements, accumulated routine quality assurance (QA) data, and peer-reviewed publications. The predicted uncertainty maps were compared with dose difference distributions between computations and 108 simple open-field measurements using a two-dimensional diode array detector to verify the validity of the model parameters and robustness of the generalized model. To examine the applicability of the model to overall dose uncertainty prediction in IMRT, a retrospective analysis of QA measurements using the diode array detector for 32 clinical IM fields was also performed. A scatter diagram and a correlation coefficient were employed to investigate a correlation of the predicted dose uncertainty distribution with the dose discrepancy distribution between calculation and delivery. In addition, a {gamma} test was performed to correlate failed regions in dose verification with the dose uncertainty map. The quantified model parameters well correlated the predicted dose uncertainty with the probable dose difference between calculations and measurements. It was visually validated with the scatter diagrams. The average correlation coefficient between uncertainty and dose difference of 108 verification measurements was 0.80{+-}0.04, indicating a strong linear correlation. In the clinical IM field studies, the dose uncertainty map mimicked the probable dose difference distribution. The average correlation coefficient between the overall dose uncertainty and the dose difference of 32 QA measurements (total 13 184 comparison points) was 0.75{+-}0.07, which also indicated a strong linear correlation between them. The failed regions of the {gamma} test remarkably corresponded to relatively high dose uncertainty. In conclusion, the dose uncertainty map was able to highlight high dose uncertainty regions, where more care should be taken during the treatment plan. The a priori accurate prediction of dose uncertainty in IMRT will significantly improve the treatment plan evaluation process, thus improving the quality of radiation treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operational Characteristics and Plasma Measurements in a Low-Energy FARAD Thruster

Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a plasma current sheet in propellant located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current with an induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism in this manner allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those found in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). In this paper, we present measurements aimed at quantifying the thruster's overall operational characteristics and providing additional insight into the nature of operation. Measurements of the terminal current and voltage characteristics during the pulse help quantify the output of the pulsed power train driving the acceleration coil. A fast ionization gauge is used to measure the evolution of the neutral gas distribution in the accelerator prior to a pulse. The preionization process is diagnosed by monitoring light emission from the gas using a photodiode, and a time-resolved global view of the evolving, accelerating current sheet is obtained using a fast-framing camera. Local plasma and field measurements are obtained using an array of intrusive probes. The local induced magnetic field and azimuthal current density are measured using B-dot probes and mini-Rogowski coils, respectively. Direct probing of the number density and electron temperature is performed using a triple probe.

Polzin, K. A.↗

The explosive transient camera - An automatic, wide-field sky monitor for short-timescale optical transients

The Explosive Transient Camera (ETC) is a widefield sky monitor designed to detect short-timescale (1-l0 s) celestial optical flashes. It consists of two arrays of wide-field CCD cameras monitoring about 0.4 steradian of the night sky for optical transients with risetimes of about 1-10 s and peak magnitudes m(V) of less than about 10. The ETC was designed to be completely automated in order to make year-round observations with minimal human intervention. A small, powerful 68,000-based computer controls all aspects of observations, including roof motion, CCD readouts, and weather sensing: under software control, the ETC is able to perform all the functions of a human observer automatically.

Vanderspek, Roland K.↗

Diamond-Coated Carbon Nanotubes for Efficient Field Emission

Field-emission cathodes containing arrays of carbon nanotubes coated with diamond or diamondlike carbon (DLC) are undergoing development. Multiwalled carbon nanotubes have been shown to perform well as electron field emitters. The idea underlying the present development is that by coating carbon nanotubes with wideband- gap materials like diamond or DLC, one could reduce effective work functions, thereby reducing threshold electric-field levels for field emission of electrons and, hence, improving cathode performance. To demonstrate feasibility, experimental cathodes were fabricated by (1) covering metal bases with carbon nanotubes bound to the bases by an electrically conductive binder and (2) coating the nanotubes, variously, with diamond or DLC by plasma-assisted chemical vapor deposition. In tests, the threshold electric-field levels for emission of electrons were reduced by as much as 40 percent, relative to those of uncoated- nanotube cathodes. Coating with diamond or DLC could also make field emission-cathodes operate more stably by helping to prevent evaporation of carbon from nanotubes in the event of overheating of the cathodes. Cathodes of this type are expected to be useful principally as electron sources for cathode-ray tubes and flat-panel displays.

Dimitrijevic, Stevan↗

Compression dynamics of quasi-spherical wire arrays with different linear mass profiles

Results of experimental studies of the implosion of quasi-spherical wire (or metalized fiber) arrays are presented. The goal of the experiments was to achieve synchronous three-dimensional compression of the plasma produced in different regions of a quasi-spherical array into its geometrical center. To search for optimal synchronization conditions, quasi-spherical arrays with different initial profiles of the linear mass were used. The following dependences of the linear mass on the poloidal angle were used: m{sub l}(θ) ∝ sin{sup –1}θ and m{sub l}(θ) ∝ sin{sup –2}θ. The compression dynamics of such arrays was compared with that of quasi-spherical arrays without linear mass profiling, m{sub l}(θ) = const. To verify the experimental data, the spatiotemporal dynamics of plasma compression in quasi-spherical arrays was studied using various diagnostics. The experiments on three-dimensional implosion of quasi-spherical arrays made it possible to study how the frozen-in magnetic field of the discharge current penetrates into the array. By measuring the magnetic field in the plasma of a quasi-spherical array, information is obtained on the processes of plasma production and formation of plasma flows from the wire/fiber regions with and without an additionally deposited mass. It is found that penetration of the magnetic flux depends on the initial linear mass profile m{sub l}(θ) of the quasi-spherical array. From space-resolved spectral measurements and frame imaging of plasma X-ray emission, information is obtained on the dimensions and shape of the X-ray source formed during the implosion of a quasi-spherical array. The intensity of this source is estimated and compared with that of the Z-pinch formed during the implosion of a cylindrical array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanoelectrode array for electrochemical analysis

A nanoelectrode array comprises a plurality of nanoelectrodes wherein the geometric dimensions of the electrode controls the electrochemical response, and the current density is independent of time. By combining a massive array of nanoelectrodes in parallel, the current signal can be amplified while still retaining the beneficial geometric advantages of nanoelectrodes. Such nanoelectrode arrays can be used in a sensor system for rapid, non-contaminating field analysis. For example, an array of suitably functionalized nanoelectrodes can be incorporated into a small, integrated sensor system that can identify many species rapidly and simultaneously under field conditions in high-resistivity water, without the need for chemical addition to increase conductivity.

47 OTHER INSTRUMENTATION↗

Experimental study of the Hall effect and electron diffusion region during magnetic reconnection in a laboratory plasma

The Hall effect during magnetic reconnection without an external guide field has been extensively studied in the laboratory plasma of the Magnetic Reconnection Experiment [M. Yamada et al., Phys. Plasmas 4, 1936 (1997)] by measuring its key signature, an out-of-plane quadrupole magnetic field, with magnetic probe arrays whose spatial resolution is on the order of the electron skin depth. The in-plane electron flow is deduced from out-of-plane magnetic field measurements. The measured in-plane electron flow and numerical results are in good agreement. The electron diffusion region is identified by measuring the electron outflow channel. The width of the electron diffusion region scales with the electron skin depth ({approx}5.5-7.5c/{omega}{sub pe}) and the peak electron outflow velocity scales with the electron Alfven velocity ({approx}0.12-0.16V{sub eA}), independent of ion mass. The measured width of the electron diffusion region is much wider and the observed electron outflow is much slower than those obtained in 2D numerical simulations. It is found that the classical and anomalous dissipation present in the experiment can broaden the electron diffusion region and slow the electron outflow. As a consequence, the electron outflow flux remains consistent with numerical simulations. The ions, as measured by a Mach probe, have a much wider outflow channel than the electrons, and their outflow is much slower than the electron outflow everywhere in the electron diffusion region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Study of the Hall Effect and Electron Diffusion Region During Magnetic Reconnection in a Laboratory Plasma

The Hall effect during magnetic reconnection without an external guide field has been extensively studied in the laboratory plasma of the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas 4, 1936 (1997)] by measuring its key signature, an out-of-plane quadrupole magnetic field, with magnetic probe arrays whose spatial resolution is on the order of the electron skin depth. The in-plane electron flow is deduced from out-of-plane magnetic field measurements. The measured in-plane electron flow and numerical results are in good agreement. The electron diffusion region is identified by measuring the electron outflow channel. The width of the electron diffusion region scales with the electron skin depth (~ 8c/ωpe) and the peak electron outflow velocity scales with the electron Alfven velocity (~ 0:11VeA), independent of ion mass. The measured width of the electron diffusion region is much wider and the observed electron outflow is much slower than those obtained in 2D numerical simulations. It is found that the classical and anomalous dissipation present in the experiment can broaden the electron diffusion region and slow the electron outflow. As a consequence, the electron outflow flux remain consistent with numerical simulations. The ions, as measured by a Mach probe, have a much wider outflow channel than the electrons, and their outflow is much slower than the electron outflow everywhere in the electron diffusion region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WFC3 Calibration and Data Processing

Wide Field Camera 3 (WFC3), a panchromatic imager being developed for the Hubble Space Telescope (HST), is now fully integrated and over the past year has completed first rounds of extensive ground testing at Goddard Space Flight Center (GSFC), in both ambient and thermal-vacuum test environments. This report summarizes the results of those tests and describes the pipeline processing methods that will be used to calibrate WFC3 data. WFC3 is designed to ensure that the superb imaging performance of HST is maintained through the end of the mission and takes advantage of recent developments in detector technology to provide new and unique capabilities for HST. WFC3 contains ultraviolet/visible (UVIS) and near-infrared (IR) imaging channels, offering high sensitivity and wide field of view over the broadest wavelength range of any HST instrument. It is slated to replace the current Wide Field and Planetary Camera 2 during Servicing Mission 4. The WFC3 UVIS channel is based on elements from the Advanced Camera for Surveys (ACS)Wide Field Camera (WFC), with a 4096x4096 pixel Marconi CCD covering a 160x160 arcsecond field of view. The WFC3 UVIS channel is optimized for maximum sensitivity in the near-UV and contains a complement of 48 spectral filters and a grism. The WFC3 IR channel uses a 1024x1024 pixel HgCdTe Hawaii-1R detector array covering a 135x135 arcsecond field of view. The array sensitivity is optimized in the 0.8-1.7micron spectral range. The IR channel accomodates 15 filters and 2 grisms for slitless spectroscopy.

Bushouse, H.↗

1 Tuning gold nanorod-nanoparticle hybrids into plasmonic Fano resonance for enhanced lightening and transmission

We investigate the optical response of a gold nanorod (NR) array coupled with a gold nanoparticle (NP) film. We show that, as the NP density is increased to the percolating regime, the NR-NP hybrids are tuned into plasmonic Fano resonance, characterized by the coherent coupling of the discrete plasmonic modes of the NR array with the continuous plasmonic modes of the NP film. As a consequence, the optical transmission of the NP film is substantially enhanced. Even more strikingly, the electromagnetic fields around the NR array become much stronger, as reflected by the two orders of magnitude enhancement in the avalanche photoluminescence. These findings may prove instrumental in the design of various plasmonic nanodevices.

36 MATERIALS SCIENCE↗

Phase-field modeling of the interactions between an edge dislocation and an array of obstacles

Obstacles, such as voids and precipitates, are prevalent in crystalline materials. They strengthen crystals by serving as barriers to dislocation glide. Here in this work, we develop a phase-field dislocation dynamics (PFDD) technique for investigating the interactions between dislocations and second-phase obstacles, which can be either voids or precipitates. The PFDD technique is constructed to account for elastic heterogeneity, elastic anisotropy, dissociation of the dislocation, and dislocation transmission across bicrystalline interfaces. Within the framework, we present a model for “pseudo-voids”, which are voids shearable by dislocations, in contrast to unphysical, unshearable voids in conventional phase-field dislocation formulations. We employ the PFDD technique to investigate the in-plane interactions between an edge dislocation and an array of nano-scale obstacles with different spacings. In this application, the interactions take place in glide planes of either a face-centered cubic (FCC) Cu or a body-centered cubic (BCC) Nb matrix, while the precipitates have a Cu 1-x Nb x composition, with x varying from 0.1 to 0.9. Our atomistic simulations find that the alloy precipitates can have an FCC, an amorphous, or a BCC phase, depending on the compositional ratio between Cu and Nb, i.e., value of x. Among all types of obstacles, the critical stresses for dislocation bypass are the highest for unshearable amorphous precipitates, followed by shearable crystalline precipitates, and then the pseudo-voids.

42 ENGINEERING↗

Phase Calibration of Antenna Arrays Aimed at Spacecraft

A document describes a method of calibrating phase differences among ground antennas in an array so that the maximum-intensity direction of the far-field interference pattern of the array coincides with the direction for aiming the antennas to enable radio communication with a distant spacecraft. The method pertains to an array typically comprising between two and four 34-m (or similar size) antennas. The antennas are first calibrated pair-wise to maximize the uplink power received at a different spacecraft that is close enough for communication via a single ground antenna. In the calibration procedure, the phase of the signal transmitted by one of the antennas is ramped through a complete cycle, thereby causing the interference pattern to sweep over this closer spacecraft and guaranteeing that, at some point during the sweep, this spacecraft is illuminated at maximum intensity. The varying received uplink power is measured by a receiver in the closer spacecraft and the measurement data are transmitted to a ground station to enable determination of the optimum phase adjustment for the direction to the closer spacecraft. This adjustment is then translated to the look direction of the distant spacecraft, which could not be reached effectively using only one antenna.

Vilnrotter, Victor↗

Effects of magnetic fields on HPGe tracking detectors

Here, we present a study of magnetic fields effects on the position resolution and energy response of hyper-pure germanium detectors. Our results provide realistic estimates of the potential impact on the resolving power of tracking-arrays from (fringe) magnetic fields present when operating together with large spectrometers. By solving the equations of motion for the electron and holes in the presence of both electric and magnetic fields, we analyzed the drift trajectories of the charge carriers to determine the deviations in the positions at the end point of the trajectories, as well as changes in drift lengths affecting the energy resolution and peak shift due to trapping. Our results show that the major effect is in the deviation of the transverse (to the electric field direction) position and suggest that, if no corrective action is taken in the pulse-shape and tracking data analysis procedures, a field strength ≳ 0.1 T will start to impact the intrinsic position resolution of 2 mm (RMS). At fields above ~1 T, the degradation of the energy response becomes observable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Infrared Imager

Experimental device has low noise and high uniformity. Infrared imaging device combines array of InSb photodetectors with array of silicon field-effect-transistor switches. InSb chip forms roof over Si chip, each InSb detector cell engaging indium bump on corresponding Si switch cell below it. FET switches in 128-by-128 array turn on in sequence, read out charges on 128-by-128 array of photodetectors and multiplex them in serial output that represents pattern of light on array of photodetectors. Useful in sensitive infrared cameras for astronomy, medicine, inspection, and military surveillance. Reads out image data at rates up to 10 MHz and expands to 256-by-256 array.

Bailey, Gary C.↗

The JPL deep-well mid-infrared array camera

We describe the development of a mid-infrared camera intended for use at the Palomar 5-m telescope and at the NASA Infrared Telescope Facility. The camera is based on Rockwell's HF-16 128x128 Si:As blocked impurity band (BIB) array. This array is unusual in that it has a well depth of approximately 30 million electrons; this will allow the use of traditional broadband astronomical filters (N and Q) while keeping a reasonable field-of-view. Measured array performance indicates that it has a read noise of 1100 electrons and shows non-linearities of less than 1% up to 65% of full well. In this paper, we discuss the array and its operating characteristics, and we give a brief overview of the camera design.

Ressler, Michael E.↗

Microshutters Arrays for the JWST Near Infrared Spectrometer

The Near Infrared Spectrograph (NIRSpec) for the James Webb Space Telescope (JWST) is an essential instrument for measuring the number and density evolution of galaxies following the epoch of initial formation. The NIRSpec is a multi-object spectrograph, allowing simultaneous observation of more than 100 candidate high redshift galaxies. A critical element of the instrument is the programmable field selector, the Microshutter Array. The system consists of four 175 x 384 arrays of individually openable shutters, close packed on a 100 x 200 micron pitch, which allow selection of over 200 candidate objects over the 3 min x 3 min field of the NIRSpec. We will describe the development, production, and test of this critical element of the NIRSpec.

Moseley, Harvey↗

The Paradox of Filamented Coronal Hole Flow but Uniform High Speed Wind

Plumes and rays in coronal holes are nearly radially aligned density striations that follow the ambient magnetic field. They have long been known, but have gained new interest with growing awareness that coronal hole flow is inherently filamentary. In retrospect, filamentary flow should have been no surprise. This is because,Beta much less than 1 in coronal holes inside approximately 10 Solar radius, allowing the flow to be filamentary down to the smallest scale of photospheric magnetic activity. While the magnetic field itself is locally smooth across any height above ca. 50,000 km, SOHO/MDI has shown that the photospheric magnetic field is a complex array of rapidly evolving small bipoles that are constantly emerging, evolving, and cancelling. The resulting activity is manifested in microflares, concentrated in the magnetic network, that produce Impulsive injections at the footpoints of coronal field lines. The uneven distribution of this activity in space and time is the source of coronal hole filamentation. What is surprising is that the radial flow speed also exhibits filamentary structure. It is not well described as smooth, spherically symmetric, diverging flow, but instead ranges from 300 to over 1000 km/s at 5.5 Solar radius among field-aligned filaments like those seen in plumes and rays [Feldman et al., JGR, Dec. 1997]. This is completely unlike the constant high speed solar wind reported beyond 0.3 AU. Consequently, plumes and filamentary structure must be strongly mixed, and the mixing must be far along by 0.3 AU to be consistent with Helios observations. The paradox is what causes the mixing? Existing models of coronal heating and solar wind acceleration hardly address this issue. One possibility we are investigating is the MHD Kelvin-Helmholtz instability, to which the shear between plumes and interplume corona is expected to become unstable at 5-10 Solar radius. This instability can be simulated and followed far into the nonlinear regime and may lead to Alfvenic fluctuations like those seen at 1 AU.

Suess, Steven T.↗