Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Local-Scale Simulations of Nucleate Boiling on Micrometer Featured Surfaces: Preprint

A high-fidelity computational fluid dynamics (CFD)-based model for bubble nucleation of the refrigerant HFE7100 on micrometer-featured surfaces is presented in this work. The single-fluid incompressible Navier-Stokes equations, along with energy transport and natural convection effects are solved on a featured surface resolved grid. An a priori cavity detection method is employed to convert raw profilometer data of a surface into well-defined cavities. The cavity information and surface morphology are represented in the CFD model by geometric mesh deformations. Surface morphology is observed to initiate buoyancy-driven convection in the liquid phase, which in turn results in faster nucleation of cavities. Simulations pertaining to a generic rough surface show a trend where smaller size cavities nucleate with higher wall superheat. This local-scale model will serve as a self-consistent connection to larger device scale continuum models where local feature representation is not possible.

97 MATHEMATICS AND COMPUTING↗

Exascale Virtualized and Programmable Distributed Cyber Resource Control: Final Scientific Technical Report

Extreme-science drives the need for distributed exascale processing and communications that are carefully, yet flexibly, managed. Exponential growth of data for scientific simulations, experimental data, collaborative data analyses, remote visualization and GRID computing requirements of scientists in fields as diverse as high energy physics, climate change, genomics, fusion, synchrotron radiation, material science, medicine, and other scientific disciplines cannot be accommodated by simply applying existing transport protocols to faster pipes. Further, scientific challenges today demand diverse research teams, heightening the need for and increasing the complexity of collaboration. To address these issues within the network layer and physical layer, we have performed a number of research activities surrounding effective allocation and management of elastic optical network (EON) resources, particularly focusing on FlexGrid transponders. FlexGrid transponders support the opportunity to build Layer-1 connections at a wide range of bandwidths and to reconfigure them rapidly. The new flexibility supports complex new ways of using the physical layer that must be carefully managed and hidden from the scientist end-users. FlexGrid networks utilize flexible (or elastic) spectral bandwidths for each data link without using fixed wavelength grids. The flexibility in spectrum allocation brings many appealing features to network operations. Current networks are designed for the worst case impairments in transmission performance and the assigned spectrum is over-provisioned. In contrast, the FlexGrid networks can operate with the highest spectral efficiency and minimum bandwidth for the given traffic demand while meeting the minimum quality of transmission (QoT) requirement. Two primary focuses of our research are: (1) resource and spectrum allocation (RSA) for IP traffic over EONs, and (2) RSA for cross-domain optical networks. Previous work concentrates primarily on large file transfers within a single domain. Adding support for IP traffic changes the nature of the RSA problem: instead of choosing to accept or deny each request for network support, IP traffic is inherently elastic and thus lends itself to a bandwidth maximization formulation. We developed a number of algorithms that could be easily deployed within existing and new FlexGrid networks, leading to networks that better support scientific collaboration. Cross-domain RSA research is essential to support large-scale FlexGrid networks, since configuration information is generally not shared or coordinated across domains. The results presented here are in their early stages. They are technically feasible and practical, but still require coordination among organizations and equipment owners and a higher-layer framework for managing network requests.

42 ENGINEERING↗

Integrated distribution system and urban district planning with high renewable penetrations

Recent efforts to reduce energy consumption and greenhouse gas emissions have resulted in the development of sustainable, smart districts with highly energy efficient buildings, renewable distributed energy resources (DERs), and support for alternative modes of transportation. However, there is typically little if any coordination between the district developers and the local utility. Most attention is paid to the district's annual net load and generation without considering their instantaneous imbalance or the connecting network's state. This presents an opportunity to learn lessons from the design of distribution feeders for districts characterized by low loads and high penetrations of DERs that can be applied to the distribution grid at large. The aim of this overview is to summarize current practices in sustainable district planning as well as advances in modeling and design tools for incorporating the power distribution system into the district planning process. Recent developments in the modeling and optimization of district power systems, including their coordination with multi-energy systems and the impact of high penetration levels of renewable energy, are introduced. Sustainable districts in England and Japan are reviewed as case studies to illustrate the extent to which distribution system planning has been considered in practice. Finally, newly developed building-to-grid modeling tools that can facilitate coordinated district and power system design with utility involvement are introduced, along with suggestions for future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cosimulating Integrated Energy Systems With Heterogeneous Digital Twins: Matching a Connected World

Energy system integration promises in-creased resiliency and the unlocking of synergies, while also contributing to our goal of decarbonization. It is enabled by both old and new technologies, glued together with data and digital services. Hydrolyzers, heat pumps, distributed renewable generation, smart buildings, and the digital grid edge are all currently the subject of integration with the power system and the energy sector at large. To plan and operate such a multidisciplinary and multisectoral system properly, insight, tools, and expertise are all needed. Further, this is exactly where the state of the art fails to deliver: tools for integrated energy systems (IESs) are still in their infancy, and many times, even academia treats these sectors separately, producing experts in each of them but not across.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Development of ultra-high field superconducting magnetic energy storage (SMES) for use in the ARPA-E project titled “Superconducting Magnet Energy Storage System with Direct Power Electronics Interface”

The purpose of the CRADA is to enable superconducting magnetic energy storage (SMES) for grid-level applications by developing a cost competitive, high energy-storage density, ultra-high field SMES coil using 2G HTS wire in combination with a flexible new modular power electronics interface capable of connection to medium voltage distribution networks.

99 GENERAL AND MISCELLANEOUS↗

Initial Atmospheric Transport of Particles

A new version of the Initial Atmospheric Transport (IAT) model has been developed. This report fully characterizes the new model. IAT is designed to model heat release into the atmosphere that contains contaminated particles. The heat release forms a buoyant puff or plume. Buoyancy is quickly dissipated in 10's to 100's of seconds through drag and entrainment of ambient air. The final location of contaminant particles in the atmosphere after dissipation of abnormal heat is an important input to long term transportation codes such as the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) code. Ultimately the settling of contaminants after long term transport provides a basis for estimating health consequences. In comparison to the old version, the new model includes explicit simulation of particles, newly formulated equations of motion for a rising puff, and a new plume model. The plume model releases many instances of a single puff along a single trajectory in a way that balances energy released over a longer period than would be appropriate for a single puff. The puff model has additions for vorticity, turbulence, virtual mass, drag, and entrainment. The particle model leads to direct interfacing between IAT and the long-term transport code HYSPLIT. Previously, particle locations were given a pattern based on IAT's puff trajectory with no particle simulation. Now, particles are explicitly simulated, and 3-D spatial distributions of particles are output based on final positions. Ballistic particles are thrown outward at high velocity from explosive events and tend to hit the ground before the end of the simulation. Non-ballistic particles tend to get pulled into the rising puff s ring of vorticity with some escaping to ambient conditions as buoyant energy dissipates. A new model verification and validation effort was made for the new plume model. The Wallops Island Solid Rocket Propellant (SRP) fire plume was extracted to a 3-D transient dataset. After calibration, the model performs better than previous single puff attempts. Even so, error levels in the process used to estimate location and ambient weather conditions approach 30%. This leads to the conclusion that unplanned photogrammetry evaluations of the IAT model are useful but not sufficiently accurate to quantify model parameters. Like previous attempts, the vertical motion entrainment parameters come out much too high in comparison to values for other studies in the literature. It is suspected that a new model of shear entrainment would alleviate this problem. Unfortunately, IAT already has more calibration parameters than the data comparisons thus far can resolve with statistical certainty. This underscores the need to verify and validate the IAT model using detailed CFD studies that allow ideal statistical comparison with the IAT model for hundreds of cases. Even so, validation by comparison to carefully planned experiments (i.e. with acceptable error levels) is also necessary because the dynamics of entrainment are at a sub-grid level for CFD. Though better validation and verification are most important, many new enhancements are still envisioned for future IAT development. These include particle rain out due to condensation and agglomeration of water, direct connection to the North American Mesoscale (NAM) weather dataset, dynamic weather conditions, including ambient particle entrainment into the puff, and detrainment at the puff to ambient mixing interface. In general, including detailed aerosol dynamics is the greatest coming challenge which will require an entire new sub-model in IAT. This is very important if contaminant particles change in such a way that they increase or decrease in their potential harm to the environment.

54 ENVIRONMENTAL SCIENCES↗

Modeling the Progenitor Stars of Observed Type IIP Supernovae

Abstract Type IIP supernovae (SNe IIP) are thought to originate from the explosion of massive stars >10M ⊙ . Their luminosity is primarily powered by the explosion energy and the radioactive decay energy of 56 Co, with the photosphere location regulated by hydrogen recombination. However, the physical connections between SNe IIP and their progenitor stars remain unclear. This paper presents a comprehensive study of SNe IIP and their progenitor stars by using the one-dimensional stellar evolution code,MESA. Our model grids consider the effects of stellar metallicity, mass, and rotation in the evolution of massive stars, as well as the explosion energy and 56 Ni production in modeling supernovae. To elucidate the observed SNe IIP and their origins, we compare their light curves (LCs) with our models. Furthermore, we investigate the impact of stellar parameters on LCs by considering stellar mass, metallicity, rotation, explosion energy, and 56 Ni production. We find that more massive stars exhibit longer plateaus due to increased photon diffusion time caused by massive ejecta. Higher metallicity leads to increased opacity and mass loss of progenitor stars. Rapid rotation affects internal stellar structures, enhancing convective mixing and mass loss, potentially affecting the plateau’s brightness and duration. Higher explosion energy results in brighter but shorter plateaus due to faster-moving ejecta. 56 Ni mass affects late-time luminosity and plateau duration, with larger masses leading to slower declines.

Astronomy & Astrophysics↗

Digital twin advanced distribution management systems (ADMS) and methods

Advanced Distribution Management Systems not generally optimize over the entire feeder because there are few high-fidelity distribution circuit models and real-time distribution-connected sensors are rare. The limited observability at the distribution level makes it difficult to globally optimize distribution operations and issue control setpoints to power systems equipment or Distributed Energy Resources (DER) to perform grid-support services. For example, setpoints can be issued to DER based on results from an optimization module that incorporates a static or time-series feeder simulation. Feeder simulation initial conditions are populated with photovoltaic (PV) and load forecasts, state estimation results, and/or digital twin measurements or state output. The real-time (RT) digital twin runs a model of the feeder to generate state estimation pseudo-measurements since there are limited live feeder measurements.

Johnson, Jay Tillay↗

Spatially resolved land and grid model of carbon neutrality in China

China has committed to achieve net carbon neutrality by 2060 to combat global climate change, which will require unprecedented deployment of negative emissions technologies, renewable energies (RE), and complementary infrastructure. At terawatt-scale deployment, land use limitations interact with operational and economic features of power systems. To address this, we developed a spatially resolved resource assessment and power systems planning optimization that models a full year of power system operations, sub-provincial RE siting criteria, and transmission connections. Our modeling results show that wind and solar must be expanded to 2,000 to 3,900 GW each, with one plausible pathway leading to 300 GW/yr combined annual additions in 2046 to 2060, a three-fold increase from today. Over 80% of solar and 55% of wind is constructed within 100 km of major load centers when accounting for current policies regarding land use. Large-scale low-carbon systems must balance key trade-offs in land use, RE resource quality, grid integration, and costs. Under more restrictive RE siting policies, at least 740 GW of distributed solar would become economically feasible in regions with high demand, where utility-scale deployment is limited by competition with agricultural land. Effective planning and policy formulation are necessary to achieve China’s climate goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Integrating High Penetrations of PV into Southern California

California regulators recently approved a plan proposed by Southern California Edison (SCE) to install 500 MW of distributed photovoltaic (PV) energy in its utility service territory over the next 5 years. The installations will include 250 MW of utility-owned solar and 250 MW of independently owned solar. SCE expects that the majority of these systems will be commercial-scale rooftop PV systems connected at various points in the distribution system. Each of the SCE rooftop PV systems will typically have a rating of 1-3 MW. To understand the impact of high-penetration PV on the distribution grid, the National Renewable Energy Laboratory (NREL) and SCE brought together a team of experts in resource assessment, distribution modeling, and planning to help analyze the impacts of adding high penetration of PV into the distribution system. Through modeling and simulation, laboratory testing, and field demonstrations, the team will address the issues identified in the analysis by fully examining the challenges, developing solutions, and transitioning those solutions to the field for large-scale deployment. This paper gives an update on the project and discusses technical results of integrating a large number of distributed PV systems into the grid.

14 SOLAR ENERGY↗

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

Completing the Circuit: Workforce Development for Advanced Building Construction and Grid-Interactive Efficient Buildings

This paper will present key findings from a future-oriented qualitative study investigating likely futures for the next 5-10 years in the architecture, engineering, construction, and operations industry. This research offers an original contribution to the buildings industry by articulating an actionable framework to more effectively build connections between built environment fields. Whereas the ideal of interdisciplinary, research driven practice underlies the approach to pedagogy at many schools of architecture, innovation in the profession, such as the integrated design process, has been limited. This project applies Legitimation Code Theory (LCT) to the analysis of data gathered from interviews and a review of industry reports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a networked hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAr regulation technologies as an example to illustrate system setups, communication requirements among different HIL simulation systems, and system connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

Xie, Fuhong↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

A DUAL-BAND MILLIMETER-WAVE KINETIC INDUCTANCE CAMERA FOR THE IRAM 30 m TELESCOPE

The Neel IRAM KIDs Array (NIKA) is a fully integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. The instrument includes dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz. The imaging sensors consist of two spatially separated arrays of KIDs. The first array, mounted on the 150 GHz branch, is composed of 144 lumped-element KIDs. The second array (220 GHz) consists of 256 antenna-coupled KIDs. Each of the arrays is sensitive to a single polarization; the band splitting is achieved by using a grid polarizer. The optics and sensors are mounted in a custom dilution cryostat, with an operating temperature of {approx}70 mK. Electronic readout is realized using frequency multiplexing and a transmission line geometry consisting of a coaxial cable connected in series with the sensor array and a low-noise 4 K amplifier. The dual-band NIKA was successfully tested in 2010 October at the Institute for Millimetric Radio Astronomy (IRAM) 30 m telescope at Pico Veleta, Spain, performing in-line with laboratory predictions. An optical NEP was then calculated to be around 2 x 10{sup -16} W Hz{sup -1/2} (at 1 Hz) while under a background loading of approximately 4 pW pixel{sup -1}. This improvement in comparison with a preliminary run (2009) verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically relevant faint and extended objects were then imaged including the Galactic Center SgrB2 (FIR1), the radio galaxy Cygnus A, and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗