Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Children's exposure to indoor air in urban nurseries-part I: CO{sub 2} and comfort assessment

Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study “Children's exposure to indoor air in urban nurseries”, aimed to: i) evaluate nurseries’ indoor concentrations of carbon dioxide (CO{sub 2}), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters–temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO{sub 2} concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. - Highlights: • High occupation and poor ventilation were main determinants of IAQ in nurseries. • T and RH indoor values found in nurseries are likely to cause thermal discomfort. • Building characteristics and an inadequate ventilation determined T and RH values. • High CO{sub 2} concentrations found could indicate accumulation of other air pollutants.

54 ENVIRONMENTAL SCIENCES↗

Applicability of aquifer impact models to support decisions at CO 2 sequestration sites

The National Risk Assessment Partnership has developed a suite of tools to assess and manage risk at CO 2 sequestration sites. This capability includes polynomial or look-up table based reduced-order models (ROMs) that predict the impact of CO 2 and brine leaks on overlying aquifers. The development of these computationally-efficient models and the underlying reactive transport simulations they emulate has been documented elsewhere (Carroll et al., 2014a; Carroll et al., 2014b; Dai et al., 2014 ; Keating et al., 2016). Here in this paper, we seek to demonstrate applicability of ROM-based analysis by considering what types of decisions and aquifer types would benefit from the ROM analysis. We present four hypothetical examples where applying ROMs, in ensemble mode, could support decisions during a geologic CO 2 sequestration project. These decisions pertain to site selection, site characterization, monitoring network evaluation, and health impacts. In all cases, we consider potential brine/CO 2 leak rates at the base of the aquifer to be uncertain. We show that derived probabilities provide information relevant to the decision at hand. Although the ROMs were developed using site-specific data from two aquifers (High Plains and Edwards), the models accept aquifer characteristics as variable inputs and so they may have more broad applicability. We conclude that pH and TDS predictions are the most transferable to other aquifers based on the analysis of the nine water quality metrics (pH, TDS, 4 trace metals, 3 organic compounds). Guidelines are presented for determining the aquifer types for which the ROMs should be applicable.

54 ENVIRONMENTAL SCIENCES↗

Optimization of adsorption processes for climate control and thermal energy storage

Adsorption based heat-pumps have received significant interest owing to their promise of higher efficiencies and energy savings when coupled with waste heat and solar energy compared to conventional heating and cooling systems. While adsorption systems have been widely studied through computational analysis and experiments, general design guidelines to enhance their overall performance have not been proposed. In this work, we identified conditions suitable for the maximum utilization of the adsorbent to enhance the performance of both intermittent as well as continuously operating adsorption systems. A detailed computational model was developed based on a general framework governing adsorption dynamics in a single adsorption layer and pellet. We then validated the computational analysis using experiments with a model system of zeolite 13X-water for different operating conditions. A dimensional analysis was subsequently carried out to optimize adsorption performance for any desired operating condition, which is determined by the choice of adsorbent-vapor pair, adsorption duration, operational pressure, intercrystalline porosity, adsorbent crystal size, and intracrystalline vapor diffusivity. The scaling analysis identifies the critical dimensionless parameters and provides a simple guideline to determine the most suitable geometry for the adsorbent particles. Based on this selection criterion, the computational model was used to demonstrate maximum utilization of the adsorbent for any given operational condition. By considering a wide range of parametric variations for performance optimization, these results offer important insights for designing adsorption beds for heating and cooling systems. (C) 2014 Elsevier Ltd. All rights reserved.

Narayanan, S↗

A Cone Beam CT-Based Study for Clinical Target Definition Using Pelvic Anatomy During Postprostatectomy Radiotherapy

Purpose: There are no accepted guidelines for target volume definition for online image-guided radiation therapy (IGRT) after radical prostatectomy (RP). This study used cone beam CT (CBCT) imaging to generate information for use in post-RP IGRT. Methods and Materials: The pelvic anatomy of 10 prostate cancer patients undergoing post-RP radiation therapy (RT) to 68.4 Gy was studied using CBCT images obtained immediately before treatment. Contoured bladder and rectal volumes on CBCT images were compared with planning CT (CT{sub ref}) volumes from seminal vesicle stump (SVS) to bladder-urethral junction. This region was chosen to approximate the prostatic fossa (PF) during a course of post-RP RT. Anterior and posterior planning target volume margins were calculated using ICRU report 71 guidelines, accounting for systematic and random error based on bladder and rectal motion, respectively. Results: A total of 176 CBCT study sets obtained 2 to 5 times weekly were analyzed. The rectal and bladder borders were reliably identified in 166 of 176 (94%) of CBCT images. Relative to CT{sub ref}, mean posterior bladder wall position was anterior by 0.1 to 1.5 mm, and mean anterior rectum wall position was posterior by 1.6 to 2.7 mm. Calculated anterior margin as derived from bladder motion ranged from 5.9 to 7.1 mm. Calculated posterior margin as derived from rectal motion ranged from 8.6 to 10.2 mm. Conclusions: Normal tissue anatomy was definable by CBCT imaging throughout the course of post-RP RT, and the interfraction anteroposterior motion of the bladder and rectum was studied. This information should be considered in devising post-RP RT techniques using image guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Method for Evaluating Quality Assurance Needs in Radiation Therapy

The increasing complexity of modern radiation therapy planning and delivery techniques challenges traditional prescriptive quality control and quality assurance programs that ensure safety and reliability of treatment planning and delivery systems under all clinical scenarios. Until now quality management (QM) guidelines published by concerned organizations (e.g., American Association of Physicists in Medicine [AAPM], European Society for Therapeutic Radiology and Oncology [ESTRO], International Atomic Energy Agency [IAEA]) have focused on monitoring functional performance of radiotherapy equipment by measurable parameters, with tolerances set at strict but achievable values. In the modern environment, however, the number and sophistication of possible tests and measurements have increased dramatically. There is a need to prioritize QM activities in a way that will strike a balance between being reasonably achievable and optimally beneficial to patients. A systematic understanding of possible errors over the course of a radiation therapy treatment and the potential clinical impact of each is needed to direct limited resources in such a way to produce maximal benefit to the quality of patient care. Task Group 100 of the AAPM has taken a broad view of these issues and is developing a framework for designing QM activities, and hence allocating resources, based on estimates of clinical outcome, risk assessment, and failure modes. The report will provide guidelines on risk assessment approaches with emphasis on failure mode and effect analysis (FMEA) and an achievable QM program based on risk analysis. Examples of FMEA to intensity-modulated radiation therapy and high-dose-rate brachytherapy are presented. Recommendations on how to apply this new approach to individual clinics and further research and development will also be discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Postmastectomy Radiotherapy in Older Women

Purpose: Clinical trials and guidelines published between 1997 and 2001 concluded that postmastectomy radiotherapy (PMRT) improves overall survival for women with high-risk breast cancer. However, the effect of these findings on current practice is not known. Using the Surveillance, Epidemiology, and End Results-Medicare cohort, we sought to characterize the adoption of PMRT from 1992 to 2002 and identify risk factors for PMRT omission among high-risk older patients. Methods and Materials: We identified 28,973 women aged {>=}66 years who had been treated with mastectomy for invasive breast cancer between 1992 and 2002. Trends in the adoption of PMRT for low- (T1-T2N0), intermediate- (T1-T2N1), and high- (T3-T4 and/or N2-N3) risk patients were characterized using a Monte Carlo permutation algorithm. Multivariate logistic regression identified the risk factors for PMRT omission and calculated the adjusted use rates. Results: Postmastectomy radiotherapy use increased gradually and consistently for low-risk (+2.16%/y) and intermediate-risk (+7.20%/y) patients throughout the study interval. In contrast, PMRT use for high-risk patients increased sharply between 1996 and 1997 (+30.99%/y), but subsequently stabilized. Between 1998 and 2002, only 53% of high-risk patients received PMRT. The risk factors for PMRT omission included advanced age, moderate to severe comorbidity, smaller tumor size, fewer positive lymph nodes, and geographic region, with adjusted use rates ranging from 63.5% in San Francisco to 44.9% in Connecticut. Conclusion: Among the high-risk patients, PMRT use increased sharply in 1997 after the initial clinical trial publication. Despite subsequent guidelines recommending the use of PMRT, no further increase in PMRT use has occurred, and nearly 50% of high-risk patients still do not receive PMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Accelerated Partial Breast Patient Alignment and Treatment With Helical Tomotherapy Unit

Purpose: To determine the precision of megavoltage computed tomography (MVCT)-based alignment of the seroma cavity for patients undergoing partial breast irradiation; and to determine whether accelerated partial breast irradiation (APBI) plans can be generated for TomoTherapy deliveries that meet the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol guidelines for target coverage and normal tissue dose limitations. Methods and Materials: We obtained 50 MVCT images from 10 patients. An interuser study was designed to assess the alignment precision. Using a standard helical and a fixed beam prototype ('topotherapy') optimizer, two APBI plans for each patient were developed. Results: The precision of the MVCT-based seroma cavity alignment was better than 2 mm if averaged over the patient population. Both treatment techniques could be used to generate acceptable APBI plans for patients that fulfilled the recommended NSABP B-39/RTOG-0413 selection criteria. For plans of comparable treatment time, the conformation of the prescription dose to the target was greater for helical deliveries, while the ipsilateral lung dose was significantly reduced for the topotherapy plans. Conclusions: The inherent volumetric imaging capabilities of a TomoTherapy Hi-Art unit allow for alignment of patients undergoing partial breast irradiation that is determined from the visibility of the seroma cavity on the MVCT image. The precision of the MVCT-based alignment was better than 2 mm ({+-} standard deviation) when averaged over the patient population. Using the NSABP B-39/RTOG-0413 guidelines, acceptable APBI treatment plans can be generated using helical- or topotherapy-based delivery techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Designing Targets for Elective Nodal Irradiation in Lung Cancer Radiotherapy: A Planning Study

Purpose: To assess doses received by mediastinal and hilar lymph node stations (LNS) delineated according to published recommendations when 'standard' two-dimensional (2D) elective fields are applied and to assess doses to critical structures when fields are designed using 2D and three-dimensional (3D) treatment planning for elective irradiation. Methods and Materials: LNS were delineated on axial CT scans according to existing recommendations. For each case and tumor location, 2D anteroposterior-posteroanterior (AP-PA) elective fields were applied using the AP-PA CT topograms. From the 2D portal fields, 3D dose distributions were then calculated to particular LNS. Next, 3D plans were prepared for elective nodal irradiation for tumors of different lobes. Doses for critical structures were compared for 2D and 3D plans. Results: LNS 1/2R, 1/2L, 3A, 3P, 5, 6, and 8 were not adequately covered in a substantial part of plans by standard 2D portals when guidelines for delineation were strictly followed. The magnitude of the lack of coverage increased with margin application. There was a trend for a higher yet probably still safe dose delivered to lung for 3D plans compared with 2D plans with a prescription dose of 45 Gy. Conclusions: 2D fields did not entirely cover LNS delineated according to the recommendations for 3D techniques. A strict adherence to these guidelines may lead to larger portals than traditionally constructed using 2D methods. Some modifications for clinical implementation are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elective Clinical Target Volumes for Conformal Therapy in Anorectal Cancer: A Radiation Therapy Oncology Group Consensus Panel Contouring Atlas

Purpose: To develop a Radiation Therapy Oncology Group (RTOG) atlas of the elective clinical target volume (CTV) definitions to be used for planning pelvic intensity-modulated radiotherapy (IMRT) for anal and rectal cancers. Methods and Materials: The Gastrointestinal Committee of the RTOG established a task group (the nine physician co-authors) to develop this atlas. They responded to a questionnaire concerning three elective CTVs (CTVA: internal iliac, presacral, and perirectal nodal regions for both anal and rectal case planning; CTVB: external iliac nodal region for anal case planning and for selected rectal cases; CTVC: inguinal nodal region for anal case planning and for select rectal cases), and to outline these areas on individual computed tomographic images. The imaging files were shared via the Advanced Technology Consortium. A program developed by one of the co-authors (I.E.N.) used binomial maximum-likelihood estimates to generate a 95% group consensus contour. The computer-estimated consensus contours were then reviewed by the group and modified to provide a final contouring consensus atlas. Results: The panel achieved consensus CTV definitions to be used as guidelines for the adjuvant therapy of rectal cancer and definitive therapy for anal cancer. The most important difference from similar atlases for gynecologic or genitourinary cancer is mesorectal coverage. Detailed target volume contouring guidelines and images are discussed. Conclusion: This report serves as a template for the definition of the elective CTVs to be used in IMRT planning for anal and rectal cancers, as part of prospective RTOG trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Larynx Preservation Clinical Trial Design: Key Issues and Recommendations-A Consensus Panel Summary

Purpose: To develop guidelines for the conduct of Phase III clinical trials of larynx preservation in patients with locally advanced laryngeal and hypopharyngeal cancer. Methods and Materials: A multidisciplinary international consensus panel developed recommendations after reviewing results from completed Phase III randomized trials, meta-analyses, and published clinical reports with updates available through November, 2007. The guidelines were reviewed and approved by the panel. Results: According to the recommendations, the trial population should include patients with T2 or T3 laryngeal or hypopharyngeal squamous cell carcinoma not considered for partial laryngectomy and exclude those with laryngeal dysfunction or age greater than 70 years. Functional assessments should include speech and swallowing. Voice should be routinely assessed with a simple, validated instrument. The primary endpoint should capture survival and function. The panel created a new endpoint: laryngo-esophageal dysfunction-free survival. Events are death, local relapse, total or partial laryngectomy, tracheotomy at 2 years or later, or feeding tube at 2 years or later. Recommended secondary endpoints are overall survival, progression-free survival, locoregional control, time to tracheotomy, time to laryngectomy, time to discontinuation of feeding tube, and quality of life/patient-reported outcomes. Correlative biomarker studies for near-term trials should include estimated glomerular filtration rate, excision repair cross-complementary-1 gene, E-cadherin and {beta}-catenin, epiregulin and amphiregulin, and TP53 mutation. Conclusions: Revised trial designs in several key areas are needed to advance the study of larynx preservation. With consistent methodologies, clinical trials can more effectively evaluate and quantify the therapeutic benefit of novel treatment options for patients with locally advanced laryngeal and hypopharyngeal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Helical Tomotherapy for Partial-Breast Irradiation of Prone-Positioned Patients

Purpose: To investigate whether helical tomotherapy can provide conformal, uniform target-dose coverage for partial-breast irradiation (PBI) of patients positioned prone while achieving organ-at-risk sparing compliant with National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 guidelines; and to report our initial experience with the delivery of prone-breast PBI treatments using tomotherapy. Methods and Materials: For our pilot study, we generated helical tomotherapy plans upon the images of 10 prone-positioned patients previously treated using conventional techniques. We also generated plans for 4 left-breast prone-positioned PBI patients who were treated using helical tomotherapy, and recalculated the planned sinograms upon the pretreatment megavoltage computed tomographic images. Of the planning target volume (PTV), 95% was prescribed to receive 38.5 Gy, administered twice daily for 5 days. Results: For our pilot study, on average the maximum point dose to the PTV was 41.3 Gy, and 99% or more of the PTV received 90% or more of the prescribed dose. RTOG 0413 dose-volume histogram objectives were fulfilled for all organs at risk except the contralateral breast, which received a maximum point dose as high as 3.2 Gy in 1 case. For the prospective prone-positioned tomotherapy PBI plans, all objectives were met except the contralateral-breast maximum dose, which was 3.7 Gy on average. Dose calculation using the planned sinogram upon the pretreatment megavoltage computed tomographic images indicated consistency with the planned dose distributions. Conclusions: Helical tomotherapy can provide conformal and uniform target-dose coverage simultaneous with adequate sparing of critical structures; in this study only the contralateral breast dose exceeded RTOG 0413 guidelines. Dosimetric results for our 4 prospective patient cases were consistent with those for our 10-case pilot study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver Variation of Clinical Target Volume Delineation in Gastric Cancer

Purpose: To evaluate interobserver variability in clinical target volume (CTV) delineation in gastric cancer performed with the help of a delineation guide. Patients and Methods: Ten radiotherapy centers that participate in the CRITICS Phase III trial were provided with a delineation atlas, preoperative CT scans, a postoperative planning CT scan, and clinical information for a gastric cancer case and were asked to construct a CTV and create a dosimetric plan according to departmental policy. Results: The volumes of the CTVs and planning target volumes (PTVs) differed greatly, with a mean (SD) CTV volume of 392 (176) cm{sup 3} (range, 240-821cm{sup 3}) and PTV volume of 915 (312) cm{sup 3} (range, 634-1677cm{sup 3}). The overlapping volume was 376cm{sup 3} for the CTV and 890cm{sup 3} for the PTV. The greatest differences in the CTV were seen at the cranial and caudal parts. After planning, dose coverage of the overlapping PTV volume showed less variability than the CTV. Conclusion: In this series of 10 plans, variability of the CTV in postoperative chemoradiotherapy for gastric cancer is large. Strict and clear delineation guidelines should be provided, especially in Phase III multicenter studies. Adaptations of these guidelines should be evaluated in clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Segmentectomy: A Novel Approach to Increase Safety and Efficacy of Radioembolization

Purpose: To describe a technique of segmental radioembolization for the treatment of patients with unresectable hepatocellular carcinoma (HCC). Radiation segmentectomy was defined as radioembolization of two or fewer hepatic segments. We sought to (1) calculate dose when activity is delivered segmentally assuming uniform and nonuniform distribution and, (2) determine safety and efficacy of this novel technique. Methods and Materials: A total of 84 patients with HCC who were treated with {sup 90}Y radioembolization using a segmental approach were included in this analysis. The dose delivered to the segment was calculated assuming uniform and nonuniform microsphere distribution within the treatment volume. To calculate dose assuming nonuniform distribution, a tumor hypervascularity ratio was assigned. Posttreatment response (using size and necrosis guidelines), toxicity, time to progression, and survival were determined. Results: The median treatment volume was 110 cm{sup 3}. The median radiation-naive liver volume was 1403 cm{sup 3}. The median dose delivered to the segment(s) assuming uniform distribution was 521 Gy. Taking into account tumor hypervascularity (nonuniform distribution), the median dose delivered to the tumor and normal infused hepatic volume was 1214 Gy and 210 Gy, respectively. Response by size and necrosis guidelines was seen in 59% and 81% of patients. Grade 3/4 biochemical toxicities were observed in 8 patients (9%). Median time to progression was 13.6 months (95% confidence interval, 9.3-18.7 months); median survival was 26.9 months (95% confidence interval, 20.5-30.2 months). Conclusions: Radiation segmentectomy is a safe and efficacious method of selectively delivering high dose to the tumor with minimal exposure of normal parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevalence and Treatment Management of Oropharyngeal Candidiasis in Cancer Patients: Results of the French Candidoscope Study

Purpose: The aim of this pharmaco-epidemiological study was to evaluate the prevalence of oropharyngeal candidiasis (OPC) in cancer patients treated with chemotherapy and/or radiotherapy. Methods and Materials: Signs and symptoms of OPC were noted for all patients. Antifungal therapeutic management was recorded in OPC patients. Patients receiving local antifungal treatments were monitored until the end of treatment. Results: Enrolled in the study were 2,042 patients with solid tumor and/or lymphoma treated with chemotherapy and/or another systemic cancer treatment and/or radiotherapy. The overall prevalence of OPC was 9.6% (95% confidence interval, 8.4%-11.0%]in this population. It was most frequent in patients treated with combined chemoradiotherapy (22.0%) or with more than two cytotoxic agents (16.9%). Local antifungal treatments were prescribed in 75.0% of OPC patients as recommended by guidelines. The compliance to treatment was higher in patients receiving once-daily miconazole mucoadhesive buccal tablet (MBT; 88.2%) than in those treated with several daily mouthwashes of amphotericin B (40%) or nystatin (18.8%). Conclusion: OPC prevalence in treated cancer patients was high. Local treatments were usually prescribed as per guidelines. Compliance to local treatments was better with once-daily drugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating the RTOG-Endorsed Brachial Plexus Contouring Atlas: An Evaluation of Reproducibility Among Patients Treated by Intensity-Modulated Radiotherapy for Head-and-Neck Cancer

Purpose: To evaluate interobserver variability for contouring the brachial plexus as an organ-at-risk (OAR) and to analyze its potential dosimetric consequences in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: Using the Radiation Therapy Oncology Group (RTOG)-endorsed brachial plexus contouring atlas, three radiation oncologists independently delineated the OAR on treatment planning computed-tomography (CT) axial scans from 5 representative patients undergoing IMRT to a prescribed dose of 70 Gy for head-and-neck cancer. Dose-volume histograms for the brachial plexus were calculated, and interobserver differences were quantified by comparing various dosimetric statistics. Qualitative analysis was performed by visually assessing the overlapping contours on a single beam's eye view. Results: Brachial plexus volumes for the 5 patients across observers were 26 cc (18-35 cc), 25 cc (21-30 cc), 29 cc (28-32 cc), 29 cc (23-38 cc), and 29 cc (23-34 cc). On qualitative analysis, minimal variability existed except at the inferolateral portion of the OAR, where slight discrepancies were noted among the physicians. Maximum doses to the brachial plexus ranged from 71.6 to 72.6 Gy, 75.2 to 75.8 Gy, 69.1 to 71.0 Gy, 76.4 to 76.9 Gy, and 70.6 to 71.4 Gy. Respective volumes receiving doses greater than 60 Gy (V60) were 8.6 to 10.9 cc, 6.2 to 8.1 cc, 8.2 to 11.6 cc, 8.3 to 10.5 cc, and 5.6 to 9.8 cc. Conclusion: The RTOG-endorsed brachial plexus atlas provides a consistent set of guidelines for contouring this OAR with essentially no learning curve. Adoption of these contouring guidelines in the clinical setting is encouraged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Gleason Grade 4 Impact on Biochemical Recurrence After Permanent Interstitial Brachytherapy in Japanese Patients With Low- or Intermediate-Risk Prostate Cancer

Purpose: To reveal a predictive factor for biochemical recurrence (BCR) after permanent prostate brachytherapy (PPB) using iodine-125 seed implantation in patients with localized prostate cancer classified as low or intermediate risk based on National Comprehensive Cancer Network (NCCN) guidelines. Methods and Materials: From January 2004 to December 2009, 414 consecutive Japanese patients with clinically localized prostate cancer classified as low or intermediate risk based on the NCCN guidelines were treated with PPB. The clinical factors including pathological data reviewed by a central pathologist and follow-up data were prospectively collected. Kaplan-Meier and Cox regression analyses were used to assess the factors associated with BCR. Results: Median follow-up was 36.5 months. The 2-, 3-, 4-, and 5-year BCR-free rates using the Phoenix definition were 98.3%, 96.0%, 91.6%, and 87.0%, respectively. On univariate analysis, the Gleason score, especially primary Gleason grade 4 in biopsy specimens, was a strong predicting factor (p < 0.0001), while age, initial prostate-specific antigen (PSA) level, T stage, and minimal dose delivered to 90% of the prostate volume (D90) were insignificant. Multivariate analysis indicated that a primary Gleason grade 4 was the most powerful prognostic factor associated with BCR (hazard ratio = 6.576, 95% confidence interval, 2.597-16.468, p < 0.0001). Conclusions: A primary Gleason grade 4 carried a worse BCR prognosis than the primary grade 3 in patients treated with PPB. Therefore, the indication for PPB in patients with a Gleason sum of 4 + 3 deserves careful and thoughtful consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Treatment Planning and Acute Toxicity Comparison of Two Pelvic Nodal Volume Delineation Techniques and Delivery Comparison of Intensity-Modulated Radiotherapy Versus Volumetric Modulated Arc Therapy for Hypofractionated High-Risk Prostate Cancer Radiotherapy

Purpose: To perform a comparison of two pelvic lymph node volume delineation strategies used in intensity-modulated radiotherapy (IMRT) for high risk prostate cancer and to determine the role of volumetric modulated arc therapy (VMAT). Methods and Materials: Eighteen consecutive patients accrued to an ongoing clinical trial were identified according to either the nodal contouring strategy as described based on lymphotropic nanoparticle-enhanced magnetic resonance imaging technology (9 patients) or the current Radiation Therapy Oncology Group (RTOG) consensus guidelines (9 patients). Radiation consisted of 45 Gy to prostate, seminal vesicles, and lymph nodes, with a simultaneous integrated boost to the prostate alone, to a total dose of 67.5 Gy delivered in 25 fractions. Prospective acute genitourinary and gastrointestinal toxicities were compared at baseline, during radiotherapy, and 3 months after radiotherapy. Each patient was retrospectively replanned using the opposite method of nodal contouring, and plans were normalized for dosimetric comparison. VMAT plans were also generated according to the RTOG method for comparison. Results: RTOG plans resulted in a significantly lower rate of genitourinary frequency 3 months after treatment. The dosimetric comparison showed that the RTOG plans resulted in both favorable planning target volume (PTV) coverage and lower organs at risk (OARs) and integral (ID) doses. VMAT required two to three arcs to achieve adequate treatment plans, we did not observe consistent dosimetric benefits to either the PTV or the OARs, and a higher ID was observed. However, treatment times were significantly shorter with VMAT. Conclusion: The RTOG guidelines for pelvic nodal volume delineation results in favorable dosimetry and acceptable acute toxicities for both the target and OARs. We are unable to conclude that VMAT provides a benefit compared with IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardizing Naming Conventions in Radiation Oncology

Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. Conclusions: Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).

62 RADIOLOGY AND NUCLEAR MEDICINE↗