Magnetron R&D toward the Amplitude Modulation Control for SRF Accelerator

The scheme of using a high efficiency magnetron to drive a superconducting radio frequency (SRF) accelerator cavity needs not only the injection phase locking but also the amplitude modulation to compensate the cavity's microphomics caused cavity voltage change and the beam loading variation. To be able to do a fast and efficient modulation, the magnetron's magnetic field has to be trimmed by an external coil to compensate the frequency pushing effect due to the anode current change [1]. A low eddy current magnetron body has been designed and built [2]. This paper will present the analytical prediction, simulation and experimental results on the 2.45 GHz magnetron test stand with the modulation frequency up to 1 kHz. In addition, the progresses on the injection lock to a copper cavity, new 1497 MHz magnetron prototype, 13 kW high power magnetron test stand development and newly built low level RF (LLRF) controller for the amplitude modulation will be reported.

Rimmer, Robert A.↗

Impact of Synthetic Parameters on Structure and Electrochemistry of High-Entropy Layered Oxide LiNi 0.2 Co 0.2 Mn 0.2 Al 0.2 Fe 0.2 O 2

Here, this study explored a high-entropy layered oxide (HELO), LiNi 0.2 Co 0.2 Mn 0.2 Al 0.2 Fe 0.2 O 2 , prepared by coprecipitation followed by heat treatment. Coprecipitation yielded a kinetically favored product, and the subsequent heat treatment under various temperatures and times allowed tuning the material toward more thermodynamically favored structures. Refinement of X-ray powder diffraction (XRD) revealed that after 450 °C treatment, ~12% of the Ni 2+ in the structure was located within the lithium cation layer. After heat treatment at 600, 700, and 800 °C, there was a continued decrease of Ni 2+ in the lithium cation layer to 9.3, 6.3, and 3.7%, respectively. Longer heat treatment times at 800 °C decreased the level to 2.5%. Electrochemical behavior was evaluated by cyclic voltammetry, galvanostatic cycling, rate capability testing, and electrochemical impedance spectroscopy, where increased loaded voltage, functional capacity, rate capability, and decreased impedance were observed for samples treated at higher temperatures with lower cation mixing. X-ray absorption near edge spectroscopy (XANES) data indicated that the redox activity of Ni and Co was dominant in the electrochemistry, while the participation of Mn or Fe was minimal. The level of Ni oxidation state change between charge and discharge related to the heat treatment temperature where the samples with high cation mixing showed lower capacity consistent with some Ni 3+ in the transition metal layer inaccessible for electron transfer. Longer heat treatment times at 800 °C did not continue to provide a benefit in electrochemical function even with some additional reduction in cation mixing.

25 ENERGY STORAGE↗

Propellant production on Mars - Single cell oxygen production test bed

A study focusing on oxygen production using resources indigenous to Mars is presented. A bank of solid zirconia electrolytic cells that will electrochemically separate oxygen from a high temperature stream of carbon dioxide is at the center of the oxygen production system. The experimental data are discussed with attention given to the cell operating temperature, the carbon dioxide flow rate, and the voltage applied across the cell.

Colvin, James↗

Reliability Evaluation of Base-Metal-Electrode (BME) Multilayer Ceramic Capacitors for Space Applications

This paper reports reliability evaluation of BME ceramic capacitors for possible high reliability space-level applications. The study is focused on the construction and microstructure of BME capacitors and their impacts on the capacitor life reliability. First, the examinations of the construction and microstructure of commercial-off-the-shelf (COTS) BME capacitors show great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and approximately 0.5 micrometers, which is much less than that of most PME capacitors. The primary reasons that a BME capacitor can be fabricated with more internal electrode layers and less dielectric layer thickness is that it has a fine-grained microstructure and does not shrink much during ceramic sintering. This results in the BME capacitors a very high volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT) and regular life testing as per MIL-PRF-123. Most BME capacitors were found to fail· with an early dielectric wearout, followed by a rapid wearout failure mode during the HALT test. When most of the early wearout failures were removed, BME capacitors exhibited a minimum mean time-to-failure of more than 10(exp 5) years. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically between 10 and 20. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. Since BME capacitors have a much smaller grain size than PME capacitors, it is reasonable to predict that BME capacitors with thinner dielectric layers may have an equivalent life expectancy to that of PME capacitors with thicker dielectric layers.

Liu, David (Donghang)↗

Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered on PMOS transistors of different widths, W{sub NARROW} = 0.24 μm and W{sub WIDE} = 10 μm. The devices are irradiated using 10 keV X-rays at several total dose steps up to 3 MGy. On the one hand, negative threshold voltage shifts of more than 3.3 V are extracted after 3 MGy on narrow transistors. Even very high, this voltage shift is consistent with RINCE in narrow open layout transistors. On the other hand, voltage shifts greater than 2.5 V are extracted on wide transistors. Obviously, this result should not be associated neither to positive charge trapping in the thin gate oxide nor to any RINCE in this very wide transistor geometry. NMOS and PMOS transistors exhibit a clear asymmetrical behaviour. But contrary to what is commonly observed at 'low' TID range, the PMOS transistor is here more impacted than the NMOS one. The final paper will thus provide an extensive study of these phenomena using other device designs and geometries tested with dedicated TID experiments to discuss whether or not this effect revealed at very high TID, i.e. several MGy, may be attributed to an enhanced high-TID induced charge trapping mechanism in thin gate oxides. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exceptional energy and new insight with a sodium–selenium battery based on a carbon nanosheet cathode and a pseudographite anode

We created a unique sodium ion battery (NIB, SIB) cathode based on selenium in cellulose-derived carbon nanosheets (CCNs), termed Se-CCN. The elastically compliant two-dimensional CCN host incorporates a high mass loading of amorphous Se (53 wt%), which is primarily impregnated into 1 cm 3 g -1 nanopores. The results in facile sodiation kinetics due to short solid-state diffusion distances and a large charge transfer area of the nanosheets were established. The architecture also leads to an intrinsic resistance to polyselenide shuttle and to disintegration/coarsening. As a Na half-cell, the Se-CCN cathode delivers a reversible capacity of 613 mA h g -1 with 88% retention over 500 cycles. The exceptional stability is achieved by using a standard electrolyte (1 M NaClO4 EC-DMC) without secondary additives or high salt concentrations. The rate capability is also superb, achieving 300 mA h g -1 at 10C. Compared to recent state-of-the-art literature, the Se-CCN is the most cyclically stable and offers the highest rate performance. As a Se–Na battery, the system achieves 992 W h kg -1 at 68 W kg -1 and 384 W h kg -1 at 10144 W kg -1 (by active mass in a cathode). We are the first to fabricate and test a Se-based full NIB, which is based on Se-CCN coupled to a Na intercalating pseudographitic carbon (PGC) anode. It is demonstrated that the PGC anode increases its structural order in addition to dilating as a result of Na intercalation at voltages below 0.2 V vs. Na/Na+. The {110} Na reflections are distinctly absent from the XRD patterns of PGC sodiated down to 0.001 V, indicating that the Na metal pore filling is not significant for pseudographitic carbons. Lastly, the battery delivers highly promising Ragone chart characteristics, for example yielding 203 and 50 W h kg -1 at 70 and 14 000 W kg -1 (via total material mass in the anode and cathode).

25 ENERGY STORAGE↗

Performance of the first 150 mm diameter Cryogenic silicon ionization detectors with contact-free electrodes

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. Still larger individual detectors are being investigated to scale up the sensitive mass of future experiments. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and 33 mm thick with masses 1.7 and 2.2 times larger than those currently planned for SuperCDMS. These devices were operated with contact-free bias electrodes to minimize leakage currents which currently limit operation at high bias voltages. The results show promise for the use of such technologies in solid state cryogenic detectors.

150 mm↗

Entropy and crystal-facet modulation of P2-type layered cathodes for long-lasting sodium-based batteries

Abstract P2-type sodium manganese-rich layered oxides are promising cathode candidates for sodium-based batteries because of their appealing cost-effective and capacity features. However, the structural distortion and cationic rearrangement induced by irreversible phase transition and anionic redox reaction at high cell voltage (i.e., >4.0 V) cause sluggish Na-ion kinetics and severe capacity decay. To circumvent these issues, here, we report a strategy to develop P2-type layered cathodes via configurational entropy and ion-diffusion structural tuning. In situ synchrotron X-ray diffraction combined with electrochemical kinetic tests and microstructural characterizations reveal that the entropy-tuned Na 0.62 Mn 0.67 Ni 0.23 Cu 0.05 Mg 0.07 Ti 0.01 O 2 (CuMgTi-571) cathode possesses more {010} active facet, improved structural and thermal stability and faster anionic redox kinetics compared to Na 0.62 Mn 0.67 Ni 0.37 O 2 . When tested in combination with a Na metal anode and a non-aqueous NaClO 4 -based electrolyte solution in coin cell configuration, the CuMgTi-571-based positive electrode enables an 87% capacity retention after 500 cycles at 120 mA g −1 and about 75% capacity retention after 2000 cycles at 1.2 A g −1 .

25 ENERGY STORAGE↗

Electrochromic Window Demonstration at the John E. Moss Federal Building, 650 Capitol Mall, Sacramento, California

Dynamic windows have the potential to provide real-time optimization of perimeter zone energy use, peak demand, comfort, amenity, and cost criteria on a seasonal or even minute-to- minute basis in response to weather, occupant or regional grid demands. Electrochromic (EC) windows, a type of dynamic window, have the ability to adjust their tint dynamically in response to a small applied voltage. In previous studies, they have shown potential to reduce heating, ventilation and air conditioning (HVAC) energy consumption and increase occupant satisfaction. This technology is available in the U.S. as a commercial product from multiple vendors with high-capacity manufacturing facilities, and could be broadly deployed if successful in a pilot test. This Green Proving Ground (GPG) program study examines the energy and comfort performance of EC windows in south-facing perimeter zones of a typical U.S. General Services Administration GSA office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A 10.6 micron laser-receiver RF subsystem

One of the problems inherent in the use of optical communication systems is the exceedingly high Doppler shift which can be expected. With the recent development of stable, linear, octavebandwidth, voltage-tunable oscillators, this problem has been solved. A laboratory tracking receiver which is capable of tracking a 1-GHz frequency shift at rates up to 12 MHz/s with subsequent coherent data demodulation was designed and tested. This work demonstrates that the design and fabrication of an RF subsystem, utilizing coherent demodulation of data, for wideband communications systems is now both feasible and practical.

Santarpia, D. E.↗

Hot-spot heating susceptibility due to reverse bias operating conditions

Because of field experience (indicating that cell and module degradation could occur as a result of hot spot heating), a laboratory test was developed at JPL to determine hot spot susceptibility of modules. The initial hot spot testing work at JPL formed a foundation for the test development. Test parameters are selected as follows. For high shunt resistance cells, the applied back bias test current is set equal to the test cell current at maximum power. For low shunt resistance cells, the test current is set equal to the cell short circuit current. The shadow level is selected to conform to that which would lead to maximum back bias voltage under the appropriate test current level. The test voltage is determined by the bypass diode frequency. The test conditions are meant to simulate the thermal boundary conditions for 100 mW/sq cm, 40C ambient environment. The test lasts 100 hours. A key assumption made during the development of the test is that no current imbalance results from the connecting of multiparallel cell strings. Therefore, the test as originally developed was applicable for single string case only.

Gonzalez, C. C.↗

Parametric and cycle tests of a 40-AH bipolar nickel-hydrogen battery

The performance of a 12 V, 40 ampere-hour bipolar battery during various charge current, discharge current, temperature, and pressure operating conditions is investigated. The cell voltages, temperatures, ampere-hours, and watt-hours derived from the charge/discharge cycle tests are studied. Consideration is given to battery voltage and discharge capacity as a function of discharge current, the correlation between energy delivered on a discharge and battery temperature, battery voltage response to pulse discharges, and the voltage-temperature relationship. The data reveal that the bipolar Ni-H battery is applicable to high power systems.

Cataldo, R. L.↗

Lightning Protection

Lightning Technologies, Inc., Pittsfield, MA, - a spinoff company founded by president J. Anderson Plumer, a former NASA contractor employee who developed his expertise with General Electric Company's High Voltage Laboratory - was a key player in Langley Research Center's Storm Hazards Research Program. Lightning Technologies used its NASA acquired experience to develop protective measures for electronic systems and composite structures on aircraft, both of which are particularly susceptible to lightning damage. The company also provides protection design and verification testing services for complete aircraft systems or individual components. Most aircraft component manufacturers are among Lightning Technologies' clients.

Source record↗

Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

Spiljak, M.↗

Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders

The anomalies in the high voltage converter modulator (HVCM) remain a major down time for the spallation neutron source facility, that delivers the most intense neutron beam in the world for scientific materials research. In this work, we propose neural network architectures based on Recurrent AutoEncoders (RAE) to detect anomalies ahead of time in the power signals coming from the HVCM. Bi-directional gated recurrent unit, bi-directional long-short term memory (LSTM), and convolutional LSTM (ConvLSTM) are developed, trained, and tested using real experimental signals from the HVCM module. The results show a good performance of the proposed RAE models, achieving precision up to 91%, recall up to 88%, false omission rate as low as 20% (i.e. 80% of the anomalies were detected), and area under the ROC curve up to 0.9. The three RAE models provide very comparable performance, with LSTM showing slightly better performance than GRU and ConvLSTM. The RAE models are benchmarked against other anomaly detection methods, including isolation forest, support vector machine, local outlier factor, feedforward and convolutional autoencoders, and others; showing a better performance. Here, the results of this study demonstrate the promising potential of RAE in anomaly detection for real-world power systems, and for increasing the reliability of the HVCM modules in the spallation neutron source.

42 ENGINEERING↗

Graphene/semiconductor silicon modified BiFeO{sub 3}/indium tin oxide ferroelectric photovoltaic device for transparent self-powered windows

We report photovoltaic response of highly transparent graphene/BiFe{sub 0.95}Si{sub 0.05}O{sub 3} (BFSiO)/ITO/glass derived from bottom-up spin coating technique. The device exhibits short-circuit-current (I{sub SC} 0.75 mA) with 1000 fold upsurge and open-circuit-voltage (V{sub OC} ∼ 0.45 V) under standard AM 1.5 illumination through graphene. In combination, I{sub SC} of 0.63 mA and V{sub OC} of 0.35 V for same illumination through ITO, reveals the prospects of harvesting indoor light. Also, crystallographic structure, red shift in band gap, leakage behavior, and ferroelectric characteristics of BFSiO thin films are reported. Reproducible transient response of I{sub SC} and V{sub OC} with quick switching (<100 ms) for 20 consecutive cycles and stability (95%) over test period of 16 weeks signifies high endurance and retentivity, promising for building integrated self-powered windows.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Off state breakdown behavior of AlGaAs / InGaAs field plate pHEMTs

Off-state breakdown voltage, V{sub br}, is an important parameter determining the maximum power output of microwave Field Effect Transistors (FETs). In recent years, the use of field plates has been widely adopted to significantly increase V{sub br}. This important technological development has extended FET technologies into new areas requiring these higher voltages and power levels. Keeping with this goal, field plates were added to an existing AlGaAs / InGaAs pseudomorphic High Electron Mobility Transistor (pHEMT) process with the aim of determining the off-state breakdown mechanism and the dependency of V{sub br} on the field plate design. To find the mechanism responsible for breakdown, temperature dependent off-state breakdown measurements were conducted. It was found that at low current levels, the temperature dependence indicates thermionic field emission at the Schottky gate and at higher current levels, impact ionization is indicated. The combined results imply that impact ionization is ultimately the mechanism that is responsible for the breakdown in the tested transistors, but that it is preceded by thermionic field emission from the gate. To test the dependence of V{sub br} upon the field plate design, the field plate length and the etch depth through the highly-doped cap layer under the field plate were varied. Also, non-field plate devices were tested along side field plate transistors. It was found that the length of the etched region under the field plate is the dominant factor in determining the off-state breakdown of the more deeply etched devices. For less deeply etched devices, the length of the field plate is more influential. The influence of surface states between the highly doped cap layer and the passivation layer along the recess are believed to have a significant influence in the case of the more deeply etched examples. It is believed that these traps spread the electric field, thus raising the breakdown voltage. Three terminal breakdown voltages approaching 60V for the most deeply recessed devices are seen.

77 NANOSCIENCE AND NANOTECHNOLOGY↗