1,359 records · Page 73

Prioritizing Uncertainties in Hydrogen Contribution to Risk in Post-Crash Outcomes for Rail

This report presents analysis from Sandia National Laboratories predicting contributions to risk associated with the use of hydrogen technology for rail. Event sequence diagrams are used to describe possible accident scenarios and progressions. Initiating event frequencies and branch event probabilities for each scenario are quantified with uncertainty using distributions fit to Federal Railroad Administration and U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration data on applicable accidents from 2000 to 2020. Uncertainty is propagated through the event sequence diagram to estimate the frequency and conditional probability of accident end states. The analysis identifies four scenarios with significant contributions to risk from hydrogen that are predicted to occur relatively frequently, which may inform priorities for reducing uncertainty. These scenarios are 1) overpressure events resulting from collisions with hydrogen release due to mechanical damage and delayed ignition, 2) jet fire events resulting from collisions with hydrogen release due to mechanical damage and immediate ignition, 3) jet fires resulting from fire or explosion initiating events involving the hydrogen tank and correct operation of the thermally-activated pressure relief device (TPRD) subsequent to the thermal insult, and 4) pressure burst resulting from fire or explosion initiating events involving the hydrogen tank and failure of the TPRD. Delayed and immediate hydrogen ignition probabilities are identified as being highly uncertain and potential candidates for reducing conservatism in the predicted frequencies for these two scenarios.

08 HYDROGEN

MARVEL Reactor Digital Engineering Developments

The MARVEL reactor project has served to introduce a new generation of engineers to the processes required to transform a reactor design from simply an idea on paper into what will be an approved, constructed, and operational nuclear power system. Much as there have been advances in materials, analysis, and evaluation methodologies over the 50 years since the last reactor was built at INL, so too has the technology for managing the engineering process itself advanced. Digital Engineering tools and methods provide improved coordination between previously siloed engineering disciplines, reduced burdens of non-value-added data transcription processes and bring forward insights and improvements that might otherwise fall later in the design stage, where changes are much more costly. While the tools and techniques to support the full digital engineering vision are not yet complete, the MARVEL design processes provide valuable demonstrations and validations of key aspects and illuminate further areas for implementation by subsequent projects.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

The Operational NASA Anomaly Gas Analyzer and Exploration Follow-Ons

The NASA Anomaly Gas Analyzer (AGA) is the culmination of nearly ten years of advancement of core technology originally developed by Vista Photonics through the Small Business Innovation Research (SBIR) program and expanded using NASA program funding. The AGA is a portable, battery operated, optical gas detection instrument for continuous monitoring of H 2 O, CO 2 , O 2 , CO, NH 3 , HCN, HF, HCl in the spacecraft environment. Real time, in-situ monitored, gas concentrations are communicated at 1 Hz through a built-in display on-orbit and additionally through a serial interface on the ground. The instruments function over the typical range of temperatures and pressures required for the spacecraft environment. A ten-year operational life is targeted. Seven AGA instruments are currently deployed on the International Space Station and two Orion-specific units are manifested for Artemis 2. A variation of the operational AGA is under development for lunar Human Landing Systems. A wider calibrated operating pressure envelope is required in this application. Otherwise, the instruments straightforwardly address lessons learned from the original AGA by improving aspects of thermal control, ruggedness, and ease-of-use. A subset of AGA-developed sensed gases (H 2 O, CO 2 , O 2 ) is the subject of the Primary Constituent Monitor (PCM) development for the Habitation and Logistics Outpost (HALO) destined for lunar orbit. Two PCMs will be installed in HALO as part of the environmental control loop where they will interface with vehicle power and communications. While the basic sensor techniques are unchanged from the AGA, these instruments have been radiation hardened to survive for many years in the harsh target environment. Current development status for these instruments will be presented along with recent developments of a naval submarine variant.

Air Monitoring

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Depletion benchmark for a high-assay low-enriched uranium fuel experiment in the advanced test reactor

Reactor physics depletion benchmarks for high-assay low-enriched uranium (HALEU) fuel are limited in number. In particular, there is limited data for HALEU benchmarks for U-10Mo (uranium-10% molybdenum) plate fuel that is being developed for use in the United States’ high performance research reactors including the Advanced Test Reactor (ATR), Advanced Test Reactor Critical Facility (ATR-C), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), University of Missouri Research Reactor (MURR), National Bureau of Standards Reactor (NBSR). These six reactors currently operate with highly enriched uranium dispersed fuel in an aluminum matrix. In support of conversion to a HALEU fuel, qualification of U-10Mo formed into a monolithic foil is being performed. Fuel qualification involves irradiating fuel specimens in the ATR. The irradiation tests provide an opportunity to benchmark depletion capabilities of reactor physics codes in support of the ATR operation, as well as develop benchmarks that can be used by other institutions to benchmark other reactor physics codes. This paper documents the development of a benchmark model of the irradiation of the ATR Full-size plate In center flux trap Position 7 (AFIP-7) experiment using the depletion codes MC21 and Advanced Dimensional Depletion for Engineering of Reactors (ADDER).

Nielsen, Joseph W. [Idaho National Laboratory (INL

Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality

Highly Porous Polyimide Gel for Use as Battery Separator with Room Temperature Ionic Liquid Electrolytes

Advanced aerospace vehicular concepts require advances in many existing technologies, including space power and energy storage systems. Batteries represent one of the major areas in need of improvement, both in terms of energy density and safety, with growing concerns over the fire safety of commercial lithium-ion batteries. This has prompted efforts to develop nonflammable battery components, namely the electrolyte and separator. Existing commercial lithium-ion batteries utilize polyolefin microporous membranes as separators with an electrolyte consisting of a lithium salt dissolved in a mixture of cyclic carbonate solvents. This separator/electrolyte combination has ionic conductivities in the range of 10 −2 to 10 −3 S/cm. However, the cyclic carbonate solvents are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative. They offer good ionic conductivities and are inherently nonvolatile and nonflammable, giving them a safety advantage. However, many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Alternative separator materials, such as polyimides, are non-flammable and are capable of accepting RTILs into their structure. Polyimide gels, with a composition of 4,4′-oxydianiline, 3,3′,4,4′-tetracarboxylic dianhydride and cross-linked with Desmodur N3300A, possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85% porosity) for lithium-ion transport and conduction, as well as good mechanical properties. Furthermore, these polyimide gels are compatible with selected imidazolium-based RTILs. Nonflammable separator/electrolyte systems with room-temperature conductivities in the range of 10 −3 S/cm have been evaluated. It has been demonstrated that 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was the most promising among six RTILs screened, in terms of both ionic conductivity and constant current cycling.

Polyimide

Physics-Guided Deep Learning for Complex System Health Management and Decision Making

The landscape of complex engineered systems is rapidly evolving, from smart manufacturing facilities to next-generation transportation vehicles. As these systems become increasingly sophisticated and interconnected, the need for advanced health management systems grows ever more critical. These systems must go beyond simple monitoring, actively predicting potential failures before they occur. This paradigm shift from fixed maintenance schedules to condition-based predictions is key to optimizing system performance, enhancing safety, and paving the way for autonomous decision-making across various industries. Whether in industrial processes, energy systems, or advanced transportation, the ability to anticipate and prevent failures is becoming a cornerstone of operational excellence. To accurately predict the future health of any complex system, knowledge of its current health state and future operational conditions is essential. Recent advancements in data-driven algorithms have generated growing interest in artificial intelligence for industrial applications. However, the limitations of pure data-driven methods, particularly in industries where data acquisition is costly and limited, have become apparent. This has led to a focus on blending physics with data-driven algorithms, mitigating the drawbacks of both approaches while emphasizing their respective advantages. This research proposes a novel framework for integrating physics-based performance models with deep learning algorithms for the prognostics of complex safety-critical systems. In this approach, physics-based models serve as a blueprint, capturing fundamental system behaviors, while deep learning algorithms, leveraging real-world sensor data, fill in gaps and identify subtle patterns indicative of potential problems. This hybrid methodology, utilizing techniques such as Physics-Informed Neural Networks (PINNs), offers a powerful solution for predicting system health. By fusing domain knowledge with data-driven insights, this approach promises more accurate, adaptable, and reliable models for health prediction. The resulting framework is versatile, applicable across various sectors including aerospace, manufacturing, and energy systems, ultimately contributing to safer, more efficient operations in our increasingly complex technological landscape.

Diagnostics

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer

The SPT-deep Cluster Catalog: Sunyaev–Zel’dovich Selected Clusters from Combined SPT-3G and SPTpol Measurements over 100 Square Degrees

We present a catalog of 500 galaxy cluster candidates in the SPT-Deep field: a 100 deg$^{2}$ field that combines data from the SPT-3G and SPTpol surveys to reach noise levels of 3.0, 2.2, and 9.0 μK-arcmin at 95, 150, and 220 GHz, respectively. Candidates are selected via the thermal Sunyaev–Zel’dovich (SZ) effect with a minimum significance of ξ = 4.0, resulting in a catalog of purity ∼89%. Optical data from the Dark Energy Survey and infrared data from the Spitzer Space Telescope are used to confirm 442 cluster candidates. The clusters span 0.12 < z ≲ 1.8 and 1.0 × 10$^{14}$M$_{⊙}$/h$_{70}$ < M$_{500c}$ < 8.7 × 10$^{14}$M$_{⊙}$/h$_{70}$. The sample’s median redshift is 0.74, and the median mass is 1.7 × 10$^{14}$M$_{⊙}$/h$_{70}$; these are the lowest median mass and highest median redshift of any SZ-selected sample to date. We assess the effect of infrared emission from cluster member galaxies on cluster selection by performing a joint fit to the infrared dust and tSZ signals by combining measurements from SPT and overlapping submillimeter data from Herschel/SPIRE. We find that at high redshift (z > 1), the tSZ signal is reduced by $17.9_{−3.2}^{+3.8}$%$(3.8_{−0.7}^{+0.9}$%$)$ at 150 GHz (95 GHz) due to dust contamination. We repeat our cluster finding method on dust-nulled SPT maps and find the resulting catalog is consistent with the nominal SPT-Deep catalog, suggesting dust contamination does not significantly impact the SPT-Deep selection function; we attribute this lack of bias to the inclusion of the SPT 220 GHz band.

79 ASTRONOMY AND ASTROPHYSICS

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Maximizing dynamic range and performance of anatase TiO 2 ECRAM through structure and programming

Here, in this study, we investigate the structure-dependent modulation characteristics of all-solid-state three-terminal electrochemical random-access memory (ECRAM) based on an anatase Li x TiO 2 channel. By directly comparing “asymmetric” and “symmetric” ECRAM device architectures, we reveal significant insight into the impact of a non-zero gate-drain open-circuit voltage and its influence on voltage vs. current-controlled gating. We also explore the impact of potentiation/depression write parameters on the symmetry, linearity, and dynamic range of the device response. Together, initial results from optimizing structure and programming approaches yielded unprecedented G max /G min ratios of >1,000 for ECRAM and hundreds of tunable memory states with excellent linearity and symmetry. Simulations based on these ECRAM devices further illustrate the promise of this analog memory technology, achieving near 2% classification error in the MNIST digit recognition benchmark for a range of training parameters compared to a theoretical best of 1.66% and outperforming other device models extracted from the literature.

AIHWKit

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell