Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

The Autonomic Symptom Profile: a new instrument to assess autonomic symptoms

OBJECTIVE: To develop a new specific instrument called the Autonomic Symptom Profile to measure autonomic symptoms and test its validity. BACKGROUND: Measuring symptoms is important in the evaluation of quality of life outcomes. There is no validated, self-completed questionnaire on the symptoms of patients with autonomic disorders. METHODS: The questionnaire is 169 items concerning different aspects of autonomic symptoms. The Composite Autonomic Symptom Scale (COMPASS) with item-weighting was established; higher scores indicate more or worse symptoms. Autonomic function tests were performed to generate the Composite Autonomic Scoring Scale (CASS) and to quantify autonomic deficits. We compared the results of the COMPASS with the CASS derived from the Autonomic Reflex Screen to evaluate validity. RESULTS: The instrument was tested in 41 healthy controls (mean age 46.6 years), 33 patients with nonautonomic peripheral neuropathies (mean age 59.5 years), and 39 patients with autonomic failure (mean age 61.1 years). COMPASS scores correlated well with the CASS, demonstrating an acceptable level of content and criterion validity. The mean (+/-SD) overall COMPASS score was 9.8 (+/-9) in controls, 25.9 (+/-17.9) in the patients with nonautonomic peripheral neuropathies, and 52.3 (+/-24.2) in the autonomic failure group. Scores of symptoms of orthostatic intolerance and secretomotor dysfunction best predicted the CASS on multiple stepwise regression analysis. CONCLUSIONS: We describe a questionnaire that measures autonomic symptoms and present evidence for its validity. The instrument shows promise in assessing autonomic symptoms in clinical trials and epidemiologic studies.

NASA Discipline Cardiopulmonary↗

Determination of balloon gas mass and revised estimates of drag and virtual mass coefficients

In support of the NASA Balloon Program, small-scale balloons were flown with varying lifting gas and total system mass. Instrument packages were developed to measure and record acceleration and temperature data during these tests. Top fitting and instrument payload accelerations were measured from launch to steady state ascent and through ballast drop transients. The development of the small lightweight self-powered Stowaway Special instrument packages is discussed along with mathematical models developed to determine gas mass, drag and virtual mass coefficients.

Robbins, E.↗

Active cavity radiometer type IV

A new cavity pyrheliometer, the active cavity radiometer type IV (ACR IV), has been developed for the measurement of total solar optical irradiance. Analysis predicts its ability to measure at the solar constant level with 0.1% uncertainty in SI units. In comparison tests ACR IVs have consistently demonstrated 0.3% higher results than the World Radiometric Reference scale. A prototype has been tested, and a flight instrument has been developed and flown in a sounding rocket experiment to determine the solar constant. ACR IV instrumentation is being developed for flight experiments on the Spacelab I and Solar Maximum missions to monitor the total solar output of optical radiation as part of a long-term program to detect variations of climatological significance.

Willson, R. C.↗

Design for a Unitary Graphite Composite Instrument Boom

This paper describes development of a Unitary graphite composite instrument boom that incorporates carpenter-tape like hinges for stowage. While light and stiff, graphite composite is not ordinarily thought of as a flexible material. This design has taken advantage of the stiffness of the composite in tubular geometry, yet leveraged its thin- section behavior to place flexibility at the required locations. Key is the proprietary layup, which results in a tough yet flexible hinge capable of rotating over 90 degrees in each direction. When the boom deploys, there is enough torque to overcome parasitic resistance from harness, etc. It will snap to the fully extended, rigid shape. The design has addressed materials issues such as out-of-plane bending, edge cracking, and interlaminar ply separation.

Alexander, Wes↗

SPICE: An innovative, flexible instrument concept

Studies and plans for orbital capture of cosmic dust and interplanetary dust particles (IDP's) looked very bright with the advent of space station Freedom (SSF) and formal selection of Cosmic Dust Collection Facility (CDCF) as an attached payload in 1990. Unfortunately it has been downhill since its selection, culminating in CDCF being dropped as attached payload in the SSF redesign process this year. This action was without any input from the science or cosmic dust communities. The Exobiology Intact Capture Experiment (Exo-ICE) as an experiment on CDCF was also lost. Without CDCF, no facility-class instrument for cosmic dust studies is available or planned. When CDCF (and Exo-ICE) was selected as a SSF attached payload, an exercise called the small particle intact capture experiment (SPICE) was started for Exo-ICE to develop an understanding and early testing of the necessary expertise and technology for intact capture of cosmic dust and IDP's. This SPICE activity looks to fly small, meter square or less, collection area experiments on early orbital platforms of opportunity such as EURECA, MIR, WESTAR, and others, including the shuttle. The SPICE activity has focused on developing techniques and instrument concepts to capture particles intact and without inadvertent contamination. It began with a survey and screening of available capture media concepts and then focused on the development of a capture medium that can meet these requirements. Evaluation and development of the chosen capture medium, aerogel (a silicon oxide gel), has so far lived up to the expectations of meeting the requirements and is highlighted in a companion paper at this workshop. Others such as McDonnell's Timeband Capture Cell Experiment (TICCE) on EuReCa and Tsuo's GAS-CAN lid experiments on STS 47 and 57 have flown aerogel, but without addressing the contamination issue/requirement, especially regarding organics. Horz, Zolenskym and others have studied and have also been advocates for its development. The SPICE instrument's experiment design builds on the knowledge gained from these efforts to meet the intact capture, noncontamination requirements. An overview of a possible SPICE experimental instrument concept using the MIR space station as a host platform for cosmic dust collection is provided in this paper. The SPICE concept is nonplatform-specified and can fly on any platform that provides a mode for experiment recovery.

Nishioka, Kenji↗

Spaceborne radar

The spaceborne radar panel considered how radar could be used to measure precipitation from satellites. The emphasis was on how radar could be used with radiometry (at microwave, visible (VIS), and infrared (IR) wavelengths) to reduce the uncertainties of measuring precipitation with radiometry alone. In addition, the fundamental electromagnetic interactions involved in the measurements were discussed to determine the key work areas for research and development to produce effective instruments. Various approaches to implementing radar systems on satellites were considered for both shared and dedicated instruments. Finally, a research and development strategy was proposed for establishing the parametric relations and retrieval algorithms required for extracting precipitation information from the radar and associated radiometric data.

Moore, R. K.↗

Estimation of errors in the TOMS total ozone measurement during the Antarctica ozone campaign of August/September 1987

The Total Ozone Mapping Spectrometer (TOMS) instrument on the Nimbus-7 satellite provides the primary source of total ozone data for the study of total ozone in the polar regions of the earth. There are two types of instrument related errors: a slowly developing drift in the instrument calibration since the launch of the instrument in October 1978 and an increase in the measurement noise beginning April, 1984. It is estimated that by October 1987, the accumulated error in the TOMS total ozone measurement due to instrument drift is about 6 m-atm-cm. The sign of the error is such that the TOMS is slightly overpredicting the long-term decrease of the Antarctica ozone. The increase in the measurement noise is more difficult to quantify, affecting some measurements by as much as 10 D.U. and others not at all. A detailed analysis of this error and its potential impact on the studies of total ozone from TOMS will be provided. There are three categories of algorithmic errors: (1) error due the unusual shape of the ozone profile in the ozone hole; (2) error caused by very low atmospheric temperatures in the ozone hole affecting the ozone absorption cross-sections at the TOMS wavelengths; and (3) errors resulting from occasionally thick stratospheric clouds that sometimes reach to 20 km in the ozone hole.

Bhartia, P. K.↗

Frequency Domain Functional Near-Infrared Spectrometer (fNIRS) for Crew State Monitoring

A frequency domain functional near-infrared spectrometer (fNIRS) and accompanying software have been developed by the NASA Glenn Research Center as part of the Airspace Operations and Safety Program (AOSP) Technologies for Airplane State Awareness (TASA)—SE211 Crew State Monitoring (CSM) Project. The goal of CSM was to develop a suite of instruments to measure the cognitive state of operators while performing operational activities. The fNIRS was one of the instruments intended for the CSM, developed to measure changes in oxygen levels in the brain noninvasively.

Jeffrey R Mackey↗

Elastic wave analyzer for icy sub-surfaces (EWAIS) in the solar system

The sub-surface structures of water-bearing icy worlds (e.g., Europa, Enceladus, and Titan) and the structures of icy regions on Mars contain critical information about their origin and evolution. These bodies have been identified as high-priority targets in the NRC Planetary Science Decadal Survey, which noted a lack of technology readiness as one impediment to related missions. An Elastic Wave Analyzer for Icy Sub-surfaces (EWAIS) instrument is being developed to acquire data that can provide answers to fundamental science questions related to these bodies. The EWAIS instrument generates and receives elastic waves using an array of piezoelectric transducers capable of operating at temperatures as low as 30K. A developed breadboard acquires reflected signals from discontinuities in the traveled materials’ impedance (the product of wave velocity and density) along the wave path. Analysis of the acquired data can be used to determine the elastic properties, presence of cracks, locations of cavities and other discontinuities, as well as the thicknesses of ice and liquid layers. The EWAIS instrument is being developed with a novel dual-frequency transmitter array that will enable reaching distances of kilometers through ice, as well as resolving smaller acoustic reflectors nearer the EWAIS instrument. The selected dual frequencies correspond to two depth ranges that can be analyzed, with resolutions of tens of centimeters in the region of tens to hundreds of meters and tens of meters on the kilometers scale, respectively. The EWAIS will be applicable for operation from any in-situ platform, including surface assets (e.g., lander and rover) and sub-surface assets (e.g., melting probes).

Bar-Cohen, Y.↗

Wall shear stress measurements using a new transducer

A new instrument has been developed for direct measurement of wall shear stress. This instrument is simple and symmetric in design with small moving mass and no internal friction. Features employed in the design of this instrument eliminate most of the difficulties associated with the traditional floating element balances. Vibration problems associated with the floating element skin friction balances have been found to be minimized by the design features and optional damping provided. The unique design of this instrument eliminates or reduces the errors associated with conventional floating-element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Measurement made in three different tunnels show good agreement with theory and data obtained by the floating element devices.

Vakili, A. D.↗

Ka-band MMIC microstrip array for high rate communications

In a recent technology assessment of alternative communication systems for the space exploration initiative (SEI), Ka-band (18 to 40 GHz) communication technology was identified to meet the mission requirements of telecommunication, navigation, and information management. Compared to the lower frequency bands, Ka-band antennas offer higher gain and broader bandwidths; thus, they are more suitable for high data rate communications. Over the years, NASA has played an important role in monolithic microwave integrated circuit (MMIC) phased array technology development, and currently, has an ongoing contract with Texas Instrument (TI) to develop a modular Ka-band MMIC microstrip subarray (NAS3-25718). The TI contract emphasizes MMIC integration technology development and stipulates using existing MMIC devices to minimize the array development cost. The objective of this paper is to present array component technologies and integration techniques used to construct the subarray modules.

Lee, R. Q.↗

Ka-band MMIC microstrip array for high rate communications

In a recent technology assessment of alternative communication systems for the space exploration initiative (SEI), Ka-band (18 to 40 GHz) communication technology was identified to meet the mission requirements of telecommunication, navigation, and information management. Compared to the lower frequency bands, Ka-band antennas offer higher gain and broader bandwidths; thus, they are more suitable for high data rate communications. Over the years, NASA has played an important role in monolithic microwave integrated circuit (MMIC) phased array technology development, and currently, has an ongoing contract with Texas Instrument (TI) to develop a modular Ka-band MMIC microstrip subarray (NAS3-25718). The TI contract emphasizes MMIC integration technology development and stipulates using existing MMIC devices to minimize the array development cost. The objective of this paper is to present array component technologies and integration techniques used to construct the subarray modules.

Lee, R. Q.↗

Using Model-Based Reasoning for Autonomous Instrument Operation

Multiprobe missions are an important part of NASA's future: Cluster, Magnetospheric Multi Scale, Global Electrodynamics and Magnetospheric Constellation are representatives from the Sun-Earth Connections Theme. To make such missions robust, reliable, and affordable, ideally the many spacecraft of a constellation must be at least as easy to operate as one spacecraft is today. To support this need for scalability, science instrumentation must become increasingly easy to operate, even as this same instrumentation becomes more capable and advanced. Communication and control resources will be at a premium for future instruments. Many missions will be out of contact with ground operators for extended periods either to reduce operations cost or because of orbits that limit communication to weekly perigee transits. Autonomous capability is necessary if such missions are to effectively achieve their operational objectives. An autonomous system is one that acts given its situation in a mission appropriate manner without external direction to achieve mission goals. To achieve this capability autonomy must be built into the system through judicious design or through a built-in intelligence that recognizes system state and manages system response. To recognize desired or undesired system states, the system must have an implicit or explicit understanding of its expected states given its history and self observations. The systems we are concerned with, science instruments, can have stringent requirements for system state knowledge in addition to requirements driven by health and safety concerns. Without accurate knowledge of the system state, the usefulness of the science instrument may be severely limited. At the same time, health and safety concerns often lead to overly conservative instrument operations further reducing the effectiveness of the instrument. These requirements, coupled with overall mission requirements including lack of communication opportunities and tolerance of environmental hazards, frame the problem of constructing autonomous science instruments. we are developing a model of the Low Energy Neutral Atom instrument (LENA) that is currently flying on board the Imager for Magnetosphere-to-Aurora Global Exploration (IMAGE) spacecraft. LENA is a particle detector that uses high voltage electrostatic optics and time-of-flight mass spectrometry to image neutral atom emissions from the denser regions of the Earth's magnetosphere. As with most spacecraft borne science instruments, phenomena in addition to neutral atoms are detected by LENA. Solar radiation and energetic particles from Earth's radiation belts are of particular concern because they may help generate currents that may compromise LENA's long term performance. An explicit model of the instrument response has been constructed and is currently in use on board IMAGE to dynamically adapt LENA to the presence or absence of energetic background radiations. The components of LENA are common in space science instrumentation, and lessons learned by modelling this system may be applied to other instruments. This work demonstrates that a model-based approach can be used to enhance science instrument effectiveness. Our future work involves the extension of these methods to cover more aspects of LENA operation and the generalization to other space science instrumentation.

Johnson, Mike↗

Testing of the Piezo-Actuators at High Dynamic Rate Operational Conditions

Reliability of the piezo-actuators deployed in SRF cavity tuners operated at high dynamic voltage range rate conditions can lead to a significant impact on the overall performance of the SRF linacs. We tested at FNAL piezoactuators P-844K075 that were developed at Physik Instrumente (PI) for LCLSII project. Although these actuators were developed for a CW linac we tested them at high dynamic rate inside a cryogenic/insulated vacuum environment. Results of the tests will be presented. Different modes of the piezo-actuators failure will be discussed.

43 PARTICLE ACCELERATORS↗

A Low Cost Thermal Control Method for Testing in a Mars Environment

Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.

MOMA↗

Research pressure instrumentation for NASA Space Shuttle main engine, modification no. 5

Research concerning the development of pressure instrumentation for the space shuttle main engine is reported. The following specific topics were addressed: (1) transducer design and materials, (2) silicon piezoresistor characterization at cryogenic temperatures, (3) chip mounting characterization, and (4) frequency response optimization.

Anderson, P. J.↗