Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Occultation of a compact radio source by Venus

The position of Venus in the radio reference frame was measured on the basis of an observation of an occultation of the compact radio source P0507 + 17 by Venus on July 19, 1988. By comparing model light curves to the observed light curves for both ingress and egress, the frame-tie offsets Delta(lambda) and Delta(beta) (ecliptic longitude and latitude) were determined. The solution for both Delta(lambda) and Delta(beta) gave results consistent with zero offsets, but with an error of about 0.2 arcsec. The egress light curve alone yielded higher accuracy for a linear combination of Delta(lambda) and Delta(beta): Delta(lambda) + 0.51 Delta(beta) = 0.026 +/-0.04 arcsec.

Linfield, R. P.↗

The calculation of take-off run

A comparatively simple method of calculating length of take-off run is developed from the assumption of a linear variation in net accelerating force with air speed and it is shown that the error involved is negligible.

Diehl, Walter S↗

Derivation of terrain slope from SAR interferometric phase gradient

The relationship between the gradient of the interferometric phase and the terrain slope, which, it is thought, would allow a derivation of the terrain slopes without phase unwrapping, is presented. A linear relationship between the interferometric phase gradient and the terrain slopes was found. A quantitative error analysis showed that only very small errors are introduced by these approximations for orbital Synthetic Aperture Radar (SAR) geometries. An example of a slope map for repeat pass interferometry from ERS-1 SAR data is given. A number of direct and indirect applications of the terrain slope are indicated: erosion and avalanche hazard studies, radiometric calibration of SAR data, and normalization of the interferometric correlation coefficient.

Wegmueller, Urs↗

Control of flexible structures with distributed sensing and processing

Technology is being developed to process signals from distributed sensors using distributed computations. These distributed sensors provide a new feedback capability for vibration control that has not been exploited. Additionally, the sensors proposed are of an optical and distributed nature and could be employed with known techniques of distributed optical computation (Fourier optics, etc.) to accomplish the control system functions of filtering and regulation in a distributed computer. This paper extends the traditional digital, optimal estimation and control theory to include distributed sensing and processing for this application. The design model assumes a finite number of modes which make it amenable to empirical determination of the design model via familiar modal-test techniques. The sensors are assumed to be distributed, but a finite number of point actuators are used. The design process is illustrated by application to a Euler beam. A simulation of the beam is used to design an optimal vibration control system that uses a distributed deflection sensor and nine linear force actuators. Simulations are also used to study the influence of design and processing errors on the performance.

Ghosh, Dave↗

Recalculation of the isotropic H functions

The isotropic H functions defined in radiative transfer theory by Chandrasekhar (1960) have been numerically recalculated for a larger number of single scattering albedo (w) values. The obtained H functions should be accurate to five decimal places at least. The H function values become highly nonlinear as w approaches 1, where calculations were performed with many more points than in Chandrasekhar (1960). A simple linear interpolation of Chandrasekhar's H function table could result in as much as 8% error in the H function values and 16% in the H(exp 2) values that appear in multiple scattering terms such as in Hapke (1981). On the other hand, Hapke's approximations (1981, 1993) give H values within 4.1% and 0.8% error, respectively.

Hiroi, Takahiro↗

Integrated Power and Attitude Control for a Spacecraft with Flywheels and Control Moment Gyroscopes

A law is designed for simultaneous control of the orientation of an Earth-pointing spacecraft, the energy stored by counter-rotating flywheels, and the angular momentum of the flywheels and control moment gyroscopes used together as all integrated set of actuators for attitude control. General. nonlinear equations of motion are presented in vector-dyadic form, and used to obtain approximate expressions which are then linearized in preparation for design of control laws that include feedback of flywheel kinetic energy error as it means of compensating for damping exerted by rotor bearings. Two flywheel 'steering laws' are developed such that torque commanded by all attitude control law is achieved while energy is stored or discharged at the required rate. Using the International Space Station as an example, numerical simulations are performed to demonstrate control about a torque equilibrium attitude and illustrate the benefits of kinetic energy error feedback.

Roithmayr, Carlos M.↗

Dynamics and Control of Attitude, Power, and Momentum for a Spacecraft Using Flywheels and Control Moment Gyroscopes

Several laws are designed for simultaneous control of the orientation of an Earth-pointing spacecraft, the energy stored by counter-rotating flywheels, and the angular momentum of the flywheels and control moment gyroscopes used together as an integrated set of actuators for attitude control. General, nonlinear equations of motion are presented in vector-dyadic form, and used to obtain approximate expressions which are then linearized in preparation for design of control laws that include feedback of flywheel kinetic energy error as a means of compensating for damping exerted by rotor bearings. Two flywheel steering laws are developed such that torque commanded by an attitude control law is achieved while energy is stored or discharged at the required rate. Using the International Space Station as an example, numerical simulations are performed to demonstrate control about a torque equilibrium attitude, and illustrate the benefits of kinetic energy error feedback. Control laws for attitude hold are also developed, and used to show the amount of propellant that can be saved when flywheels assist the CMGs. Nonlinear control laws for large-angle slew maneuvers perform well, but excessive momentum is required to reorient a vehicle like the International Space Station.

Roithmayr, Carlos M.↗

Multipath calibration in GPS pseudorange measurements

Novel techniques are disclosed for eliminating multipath errors, including mean bias errors, in pseudorange measurements made by conventional global positioning system receivers. By correlating the multipath signals of different satellites at their cross-over points in the sky, multipath mean bias errors are effectively eliminated. By then taking advantage of the geometrical dependence of multipath, a linear combination of spherical harmonics are fit to the satellite multipath data to create a hemispherical model of the multipath. This calibration model can then be used to compensate for multipath in subsequent measurements and thereby obtain GPS positioning to centimeter accuracy.

Kee, Changdon↗

NASA's CLARREO Pathfinder Mission: The Reflected Solar’s First SITSat

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder mission will take reflected solar (RS) highly accurate measurements needed to monitor Earth’s climate and will be the first RS SI-traceable Satellite Sensor (SITSat). The mission includes a RS spectrometer that will be installed on the International Space Station (ISS) and take measurements for at least one year. CLARREO Pathfinder (CPF) will use on-orbit calibration to achieve an unprecedented high accuracy with SI-traceability and the inter-calibration of other on-orbit instruments. The spectrometer is based on the HyperSpectral Imager for Climate Science (HySICS) instrument developed by the University of Colorado/Laboratory for Atmospheric and Space Physics of Boulder, CO, USA. HySICS is being designed to have a radiometric uncertainty of 0.3% (1-sigma), a five to ten times improvement over existing spaceflight RS instruments. High accuracy SI-traceable measurements such as these are critical to develop long-term climate-quality data sets. Additionally, by measuring spectral reflectance with high accuracy the CPF instrument will serve as an on-orbit intercalibration radiometric reference for operational Earth-viewing sensors, such as the Clouds and Earth’s Radiant Energy System (CERES) broadband shortwave instrument and the Visible/Infrared Imaging Radiometer Suite (VIIRS). Two-axis pointing, a spectral range from 350 nm to 2300 nm, and a spectral resolution ≤6 nm enable CPF to provide nearly coincident temporal, spatial, angular, and spectral matching of intercalibration targets, with sampling sufficient to reduce random errors. The intercalibration method will refine knowledge of target sensors’ effective offsets, gain, non-linearity, spectral response, and polarization sensitivity (as is relevant). Calibrated reflectance and reflected radiance spectra will be distributed to the scientific community through a NASA Distributed Active Archive Center (DAAC). We will present an overview of the CLARREO Pathfinder mission, its anticipated impact on monitoring climate variability, and the novel CPF direct intercalibration approach.

climate↗

A line-source method for aligning on-board and other pinhole SPECT systems

Purpose: In order to achieve functional and molecular imaging as patients are in position for radiation therapy, a robotic multipinhole SPECT system is being developed. Alignment of the SPECT system—to the linear accelerator (LINAC) coordinate frame and to the coordinate frames of other on-board imaging systems such as cone-beam CT (CBCT)—is essential for target localization and image reconstruction. An alignment method that utilizes line sources and one pinhole projection is proposed and investigated to achieve this goal. Potentially, this method could also be applied to the calibration of the other pinhole SPECT systems.Methods: An alignment model consisting of multiple alignment parameters was developed which maps line sources in three-dimensional (3D) space to their two-dimensional (2D) projections on the SPECT detector. In a computer-simulation study, 3D coordinates of line-sources were defined in a reference room coordinate frame, such as the LINAC coordinate frame. Corresponding 2D line-source projections were generated by computer simulation that included SPECT blurring and noise effects. The Radon transform was utilized to detect angles (α) and offsets (ρ) of the line-source projections. Alignment parameters were then estimated by a nonlinear least squares method, based on the α and ρ values and the alignment model. Alignment performance was evaluated as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise, and acquisition geometry. Experimental evaluations were performed using a physical line-source phantom and a pinhole-collimated gamma camera attached to a robot.Results: In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, six alignment parameters (three translational and three rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distribution-Agnostic Stochastic Optimal Power Flow for Distribution Grids

This paper outlines a data-driven, distributionally robust approach to solve chance-constrained AC optimal power flow problems in distribution networks. Uncertain forecasts for loads and power generated by photovoltaic (PV) systems are considered, with the goal of minimizing PV curtailment while meeting power flow and voltage regulation constraints. A data- driven approach is utilized to develop a distributionally robust conservative convex approximation of the chance-constraints; particularly, the mean and covariance matrix of the forecast errors are updated online, and leveraged to enforce voltage regulation with predetermined probability via Chebyshev-based bounds. By combining an accurate linear approximation of the AC power flow equations with the distributionally robust chance constraint reformulation, the resulting optimization problem becomes convex and computationally tractable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tail Biting Trellis Representation of Codes: Decoding and Construction

This paper presents two new iterative algorithms for decoding linear codes based on their tail biting trellises, one is unidirectional and the other is bidirectional. Both algorithms are computationally efficient and achieves virtually optimum error performance with a small number of decoding iterations. They outperform all the previous suboptimal decoding algorithms. The bidirectional algorithm also reduces decoding delay. Also presented in the paper is a method for constructing tail biting trellises for linear block codes.

Shao. Rose Y.↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.

ASTROMETRY↗

LCLS X-ray mirror measurements using a large aperture visible light interferometer

Synchrotron or FEL X-ray mirrors are required to deliver an X-ray beam from its source to an experiment location, without contributing significantly to wave front distortion. Accurate mirror figure measurements are required prior to installation to meet this intent. This paper describes how a 300 mm aperture phasing interferometer was calibrated to <1 nm absolute accuracy and used to mount and measure 450 mm long flats for the Linear Coherent Light Source (LCLS) at Stanford Linear Accelerator Center. Measuring focus mirrors with an interferometer requires additional calibration, because high fringe density introduces systematic errors from the interferometer's imaging optics. This paper describes how these errors can be measured and corrected. The calibration approaches described here apply equally well to interferometers larger than 300 mm aperture, which are becoming more common in optics laboratories. The objective of this effort was to install LCLS flats with < 10 nm of spherical curvature, and < 2 nm rms a-sphere. The objective was met by measuring the mirrors after fabrication, coating and mounting, using a 300 mm aperture phasing interferometer calibrated to an accuracy < 1 nm. The key to calibrating the interferometer accurately was to sample the error using independent geometries that are available. The results of those measurements helped identify and reduce calibration error sources. The approach used to measure flats applies equally well to focus mirrors, provided an additional calibration is performed to measure the error introduced by fringe density. This calibration has been performed on the 300 mm aperture interferometer, and the measurement correction was evaluated for a typical focus mirror. The 300 mm aperture limitation requires stitching figure measurements together for many X-ray mirrors of interest, introducing another possible error source. Stitching is eliminated by applying the calibrations described above to larger aperture instruments. The authors are presently extending this work to a 600 mm instrument. Instruments with 900 mm aperture are now becoming available, which would accommodate the largest mirrors of interest.

43 PARTICLE ACCELERATORS↗

An asymptotically compatible treatment of traction loading in linearly elastic peridynamic fracture

Meshfree discretizations of state-based peridynamic models are attractive due to their ability to naturally describe fracture of general materials. However, two factors conspire to prevent meshfree discretizations of state-based peridynamics from converging to corresponding local solutions as resolution is increased: quadrature error prevents an accurate prediction of bulk mechanics, and the lack of an explicit boundary representation presents challenges when applying traction loads. Herein, we develop a reformulation of the linear peridynamic solid (LPS) model to address these shortcomings, using improved meshfree quadrature, a reformulation of the nonlocal dilatation, and a consistent handling of the nonlocal traction condition to construct a model with rigorous accuracy guarantees. In particular, these improvements are designed to enforce discrete consistency in the presence of evolving fractures, whose a priori unknown location render consistent treatment difficult. In the absence of fracture, when a corresponding classical continuum mechanics model exists, our improvements provide asymptotically compatible convergence to corresponding local solutions, eliminating surface effects and issues with traction loading which have historically plagued peridynamic discretizations. When fracture occurs, our formulation automatically provides a sharp representation of the fracture surface by breaking bonds, avoiding the loss of mass. We provide rigorous error analysis and demonstrate convergence for a number of benchmarks, including manufactured solutions, free-surface, nonhomogeneous traction loading, and composite material problems. Finally, we validate simulations of brittle fracture against a recent experiment of dynamic crack branching in soda-lime glass, providing evidence that the scheme yields accurate predictions for practical engineering problems.

42 ENGINEERING↗

Optimization-based, property-preserving algorithm for passive tracer transport

Here we present a new optimization-based property-preserving algorithm for passive tracer transport. The algorithm utilizes a semi-Lagrangian approach based on incremental remapping of the mass and the total tracer. However, unlike traditional semi-Lagrangian schemes, which remap the density and the tracer mixing ratio through monotone reconstruction or flux correction, we utilize an optimization-based remapping that enforces conservation and local bounds as optimization constraints. In so doing we separate accuracy considerations from preservation of physical properties to obtain a conservative, second-order accurate transport scheme that also has a notion of optimality. Moreover, we prove that the optimization-based algorithm preserves linear relationships between tracer mixing ratios. We illustrate the properties of the new algorithm using a series of standard tracer transport test problems in a plane and on a sphere.

97 MATHEMATICS AND COMPUTING↗