Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A Test of ASTM Methods E1245-03 and E562-11 in Calculating the Volume Fraction of Carbides in a U-10Mo Foil

Volume fraction measurements of carbides in DU-10Mo castings and foils were performed as part of a round robin study aimed at ensuring characterization efforts by multiple laboratories were yielding consistent results. Three of the four labs employed an automatic image analysis method to determine volume fraction of carbides in the metal and reported results around 2%. The other laboratory used a grid intercept count method and reported a fraction percentage of above 5%, about 3% higher than the other labs. At LANL, the method ASTM E1245-03, Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis was employed with a result of 2.02 ± .26%. There was a need to resolve the large discrepancy in volume fraction measurements reported from the round robin participant that used the grid intercept method. To do this, the grid intercept method outlined in ASTM E562-11, Determining Volume Fraction by Systematic Manual Point Count was also performed on the exact set of micrographs already analyzed by image analysis software at LANL. Calculations carried out following the manual point count method reported a percentage of 2.2 ± .6% similar to the result yielded by the automated image analysis method. Explanations for discrepancies in the results of the two methods are proposed.

36 MATERIALS SCIENCE↗

Initial Development of an Improved Creep-Fatigue Design Method that Avoids the Separate Evaluation of Creep and Fatigue Damage and Eliminates the Requirement for Stress Classification

This report describes a method for capturing the effect of strain range, temperature, hold time, and elastic follow up on the cyclic life of a material undergoing uniaxial load. Developing design correlations of this type requires methods for extrapolating experimental data as a function of hold time and follow up factor. Various extrapolation methods are developed and discussed here and recommendations are developed for the final approaches to be adopted for design use. The report also describes comparisons between the new creep-fatigue design method, described here, and current creep-fatigue design methods in the ASME Boiler and Pressure Vessel Code and associated nuclear Code Cases. These comparisons demonstrate several advantages of the new method: it is easier to execute and is less over conservative than many current approaches. This report, along with a companion on extending these results to multiaxial load and on combining load cycles, represents the accumulation of several years of work on the development of this new approach to creep-fatigue design, combining an elastic perfectly plastic analysis method with simplified model tests measuring the effect of elastic follow up on creep-fatigue cyclic life. The conclusions to this report describe a path forward to developing the required design data for high temperature advanced reactor structural materials and guiding the adoption of the new method in the ASME Boiler and Pressure Vessel Code and related standards.

36 MATERIALS SCIENCE↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An efficient method to estimate the probability density of seismic Green's functions

We present a computationally efficient method to approximate the probability distribution of seismic Green's functions given the uncertainty of an Earth model. The method is based on the Karhunen-Loève (KL) theorem and an approximation of the Green's function (or seismogram) covariance. Using Monte Carlo (MC) simulations as a control case, we demonstrate that our KL-based method can accurately reproduce a probability distribution of seismograms that results from an uncertain Earth model for a MC-derived seismogram covariance. We then describe a method to estimate the covariance of the seismograms resulting from those Earth models that is not based on MC simulations. We use the estimated Green's function covariance in conjunction with our KL-based method to produce a Green's function probability distribution, and compare that distribution to a Green's function probability distribution produced using a MC finite difference method. We find that the Green's function probability distribution approximated using our KL-based method generally mimics that produced using the MC simulations, especially for direct-arriving body waves. However the accuracy of the KL-based method generally decreases for later times in the simulated Green's function distribution.

58 GEOSCIENCES↗

Harnessing Condorcet Methods to Improve Decision-making Based on Ranked Data

Decision-makers must often choose between multiple alternatives based on their relative merits across a variety of criteria. These multiple-criteria decision-making (MCDM) problems must be approached in an objective, measurable, and transparent fashion to obtain well-supported outcomes. The challenge of using sets of ranked data to identify the optimal choice is not unlike the challenge of using ranked ballots to identify the winner of an election in a preference voting system. As such, the methods of rank aggregation used in elections can be applied to help resolve MCDM problems. Previous research into the design of elections and ballots has yielded many algorithms with well-understood properties. A subset of these, called Condorcet methods, reliably identify the “Condorcet winner,” if it exists, giving the result that would defeat any other in a pairwise comparison. That, in addition to several other desirable qualities, makes Condorcet methods like the Schulze method, Ranked Pairs, and Copeland’s method, effective and scalable means for tackling MCDM problems. These rank aggregation methods have been implemented in JavaScript functions for incorporation into a web-based MCDM decision tool. These algorithms can be applied in a wide variety of contexts (for example, determining the “best” environmental remediation method or selecting a subcontractor) to facilitate effective decision-making. The performance of the JavaScript Condorcet prototype tool was compared across the implemented algorithms and with both a non-Condorcet rank aggregation method as well as an implementation of the Simple Multi-Attribute Rating Technique (SMART) algorithm.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exnihilo Transport Methods Manuals Revision 0

Exnihilo is a transport code system that contains both deterministic and stochastic (Monte Carlo) solvers. The deterministic solvers are contained in the Denovo package while the Monte Carlo solvers are implemented in the Shift package. This document explains the mathematical and numerical methods employed within Exnihilo. It is not a users guide, nor is it a code developer's manual. Naturally, there is cross-over between the code implementation and mathematical description of any given method, and these are included for the purpose of greater understanding where appropriate. The purpose of this document is to formally describe the equations that are solved by the various packages inside of Exnihilo. In general, linkages are not made between a given numerical method and the Exnihilo code base. This is largely due to the fact that the Exnihilo code base changes far more rapidly than the actual methods that it is solving. Thus, this documentation would go rapidly out of date if cross-references were made between the methods and the code that implements them. Instead, developers are encouraged to look at the Doxygen-produced code documentation that explains what each translation unit in the code is doing. Where necessary we will make distinctions between methods that are implemented in Exnihilo and methods that are documented to provide better understanding of the broader field and provide context for the chosen methods in Exnihilo.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Assessment of Bacterial Inoculant Delivery Methods for Cereal Crops

Despite growing evidence that plant growth-promoting bacteria can be used to improve crop vigor, a comparison of the different methods of delivery to determine which is optimal has not been published. An optimal inoculation method ensures that the inoculant colonizes the host plant so that its potential for plant growth-promotion is fully evaluated. The objective of this study was to compare the efficacy of three seed coating methods, seedling priming, and soil drench for delivering three bacterial inoculants to the sorghum rhizosphere and root endosphere. The methods were compared across multiple time points under axenic conditions and colonization efficiency was determined by quantitative polymerase chain reaction (qPCR). Two seed coating methods were also assessed in the field to test the reproducibility of the greenhouse results under non-sterile conditions. In the greenhouse seed coating methods were more successful in delivering the Gram-positive inoculant (Terrabacter sp.) while better colonization from the Gram-negative bacteria (Chitinophaga pinensis and Caulobacter rhizosphaerae) was observed with seedling priming and soil drench. This suggested that Gram-positive bacteria may be more suitable for the seed coating methods possibly because of their thick peptidoglycan cell wall. We also demonstrated that prolonged seed coating for 12 h could effectively enhance the colonization of C. pinensis, an endophytic bacterium, but not the rhizosphere colonizing C. rhizosphaerae. In the field only a small amount of inoculant was detected in the rhizosphere. This comparison demonstrates the importance of using the appropriate inoculation method for testing different types of bacteria for their plant growth-promotion potential.

Terrabacter↗

Enhanced Co-Expression Extrapolation (COXEN) Gene Selection Method for Building Anti-Cancer Drug Response Prediction Models

The co-expression extrapolation (COXEN) method has been successfully used in multiple studies to select genes for predicting the response of tumor cells to a specific drug treatment. Here, we enhance the COXEN method to select genes that are predictive of the efficacies of multiple drugs for building general drug response prediction models that are not specific to a particular drug. The enhanced COXEN method first ranks the genes according to their prediction power for each individual drug and then takes a union of top predictive genes of all the drugs, among which the algorithm further selects genes whose co-expression patterns are well preserved between cancer cases for building prediction models. We apply the proposed method on benchmark in vitro drug screening datasets and compare the performance of prediction models built based on the genes selected by the enhanced COXEN method to that of models built on genes selected by the original COXEN method and randomly picked genes. Models built with the enhanced COXEN method always present a statistically significantly improved prediction performance (adjusted p-value ≤ 0.05). Our results demonstrate the enhanced COXEN method can dramatically increase the power of gene expression data for predicting drug response.

60 APPLIED LIFE SCIENCES↗

A new method for inferring city emissions and lifetimes of nitrogen oxides from high-resolution nitrogen dioxide observations: a model study

We present a new method to infer emissions and lifetimes of nitrogen oxides (NO x ) based on tropospheric nitrogen dioxide (NO 2 ) observations together with reanalysis wind fields for cities located in polluted backgrounds. Since the accuracy of the method is difficult to assess due to lack of “true values” that can be used as a benchmark, we apply the method to synthetic NO 2 observations derived from the NASA-Unified Weather Research and Forecasting (NU-WRF) model at a high horizontal spatial resolution of 4 km × 4 km for cities over the continental United States. We compare the inferred emissions and lifetimes with the values given by the NU-WRF model to evaluate the method. The method is applicable to 26 US cities. The derived results are generally in good agreement with the values given by the model, with the relative differences of 2 % ± 17 % (mean ± standard deviation) and 15 % ± 25 % for lifetimes and emissions, respectively. Our investigation suggests that the use of wind data prior to the satellite overpass time improves the performance of the method. The correlation coefficients between inferred and NU-WRF lifetimes increase from 0.56 to 0.79 and for emissions increase from 0.88 to 0.96 when comparing results based on wind fields sampled simultaneously with satellite observations and averaged over 9 h data prior to satellite observations, respectively. We estimate that uncertainties in NO x lifetime and emissions arising from the method are approximately 15 % and 20 %, respectively, for typical (US) cities. The total uncertainties reach up to 43% (lifetimes) and 45% (emissions) by considering the additional uncertainties associated with satellite NO 2 observations and wind data. We expect this new method to be applicable to NO 2 observations from the TROPOspheric Monitoring Instrument (TROPOMI) and geostationary satellites, such as Geostationary Environment Monitoring Spectrometer (GEMS) or the Tropospheric Emissions: Monitoring Pollution (TEMPO) instrument, to estimate urban NO x emissions and lifetimes globally.

54 ENVIRONMENTAL SCIENCES↗

Method for producing smooth inner surfaces

The invention provides a method for preparing superconducting cavities, the method comprising causing polishing media to tumble by centrifugal barrel polishing within the cavities for a time sufficient to attain a surface smoothness of less than 15 nm root mean square roughness over approximately a 1 mm.sup.2 scan area. The method also provides for a method for preparing superconducting cavities, the method comprising causing polishing media bound to a carrier to tumble within the cavities. The method also provides for a method for preparing superconducting cavities, the method comprising causing polishing media in a slurry to tumble within the cavities.

36 MATERIALS SCIENCE↗

Standard Analytical Methods for Pyrolysis Bio-Oils

There has been significant recent interest in the production of renewable fuels and chemicals from biomass and waste feedstocks. Pyrolysis pathways produce a liquid bio-oil product, which must be processed further, or upgraded, to yield fuel or chemical products. Bio-oils are very complex and often unstable samples, and research and development on upgrading processes needs reliable analytical information. In particular, chemical characterization techniques are needed to quantify both functional groups and individual compounds present in bio-oils. Reliable analytics are also needed to enable the bioenergy industry, as industrial facilities often have different analytical needs and capabilities than research facilities. In this presentation, we will discuss the development of a suite of standard analytical methods for pyrolysis bio-oils. Analytical methods to be discussed include: Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in bio-oils; Accelerated Aging of Fast Pyrolysis Bio-oil using Carbonyl Titration; Determination of Water Content in Bio-oils by Volumetric Karl Fischer Titration; Determination of Carbon Functional Groups; Elemental Analysis of Bio-oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) - Na, K, Mg, Ca, S, P, and Fe; Determination of Phenolic Groups in Bio-oils using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader; Corrosivity of Bio-oils: Screening Test using Metal Leaching; Determination of Biogenic Content by 14C Measurement using Liquid Scintillation Counter. These new analytical methods are publicly available as Laboratory Analytical Procedures (https://www.nrel.gov/bioenergy/bio-oil-analysis.html), along with previously developed standard methods: GC-MS, Acid Titration, Carbonyl Titration, and 31P NMR. Additionally, the development of diffusion ordered NMR for characterization of bio-oil molecular weight will be discussed. Collectively, this suite of analytical methods represents the most comprehensive set of standard methods available for pyrolysis bio-oils. These standard methods are commonly used by the bioenergy community, and provide reliable information that enables research, scaleup, and industrial processing of biomass to produce renewable fuels and chemicals.

analytical↗

Critical node treatment in the analytic function expansion method for Pin Power Reconstruction

Pin Power Reconstruction (PPR) was implemented in PARCS using the eight term analytic function expansion method (AFEN). This method has been demonstrated to be both accurate and efficient. However, similar to all the methods involving analytic functions, such as the analytic node method (ANM) and AFEN for nodal solution, the use of AFEN for PPR also has potential numerical issue with critical nodes. The conventional analytic functions are trigonometric or hyperbolic sine or cosine functions with an angular frequency proportional to buckling. For a critic al node the buckling is zero and the sine functions becomes zero, and the cosine function become unity. In this case, the eight terms of the analytic functions are no longer distinguishable from ea ch other which makes their corresponding coefficients can no longer be determined uniquely. The mode flux distribution of critical node can be linear while the conventional analytic functions can only express a uniform distribution. If there is critical or near critical node in a plane, the reconstructed pin power distribution is often be shown negative or very large values using the conventional method. In this paper, we propose a new method to avoid the numerical problem wit h critical nodes which uses modified trigonometric or hyperbolic sine functions which are the ratio of trigonometric or hyperbolic sine and its angular frequency. If there are no critical or near critical nodes present, the new pin power reconstruction method with modified analytic functions are equivalent to the conventional analytic functions. The new method is demonstrated using the L336C5 benchmark problem. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Uranium Measurements in Water by Various Methods - 13571

In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will indicate which test method is the most accurate and most cost effective. This paper provides a benefit to Formerly Utilized Sites Remedial Action Program (FUSRAP) and other Department of Defense (DOD) programs that may be performing uranium measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Gamma Attenuation Methods Utilized for Waste Characterization of UO{sub 2}F{sub 2}-Bearing Materials at the Paducah GDP - 17327

The Paducah Gaseous Diffusion Plant (PGDP) is currently under deactivation with demolition in the decades to follow. UO{sub 2}F{sub 2}-bearing waste is generated at PGDP by UF{sub 6} hydrolysing to materials such as pipes, valves, PPE, etc. when UF{sub 6} is exposed to humid air. In addition, Al{sub 2}O{sub 3} and NaF trap materials contain significant amounts of Uranium. The UO{sub 2}F{sub 2} deposits within the generated waste can be of sub-gram levels to several hundreds of localized grams and are much denser than the surrounding interfering matrix materials and may be of very complex geometric and chemical forms such as with the Al{sub 2}O{sub 3} and NaF trap materials. The main objective is to characterize the fissile (U-235) content of the UO{sub 2}F{sub 2}-bearing waste so as to meet the Data Quality Objectives (DQO) for proper disposal. If a waste container cannot meet the DQO then it must be subjected to costly remediation, repackaging and re-characterization processes. We have developed, at PGDP, several novel model-based methods and techniques that vastly improve the standard gamma attenuation correction methods and do not require Working Reference Materials (WRM) for calibration. These new methods involve rotating and non-rotating 18.9 liter (5 U.S. gallon) waste containers with and without a transmission modality. A new model-based variant of differential attenuation has been developed that provides a high-quality self-absorption correction that does not require knowledge of the Uranium enrichment or isotopic ratios. For more challenging waste containers, a method using multi-view (non-rotating) 18.9 liter waste containers has been considered using a recently developed Advanced ISOCS{sup C} Uncertainty Estimator (AIUE) package. The new methods suffice to significantly improve accuracy and precision and to lower the Total Measurement Uncertainty (TMU) leading to satisfactory DQO's that were not previously achievable using the standard gamma attenuation correction methods. In this paper we present real 18.9 liter waste container and Working Reference Material (WRM) data subjected to the new methods and compared to standard methods depicting the significant improvement in the DQO that is realized. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deterministic-Monte Carlo Hybrid Methods for Eigenvalue Sensitivity Coefficient Calculations

The TSUNAMI suite within the SCALE code package includes several methods for generating sensitivity data, including multigroup (MG) and continuous-energy (CE) capabilities. For generating sensitivities with CE data, three methods are available in SCALE 6.3.0: (1) the iterated fission probability (IFP) method with the KENO Monte Carlo transport solver, (2) IFP with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance Characterization (CLUTCH) with the KENO Monte Carlo transport solver. Currently, it is difficult to generate accurate sensitivities with large reflectors when using the CLUTCH method, specifically with fissionable and hydrogenous materials. To address this issue, the work presented herein examines a methodology to calculate the adjoint flux externally with the 3D deterministic SN transport code DENOVO in SCALE; the result is then read directly into the CLUTCH-TSUNAMI sequence. This hybridization method replaces the Monte Carlo F*(r) calculation in CLUTCH while still utilizing the forward calculation. The critical benchmark HEU-MET-FAST-028-001 is used to generate sensitivities based on the inability of CLUTCH to generate accurate sensitivities. Results from the hybrid method appear to generate sensitivity values that are in excellent agreement with direct perturbations. Although further testing is needed, the method provides promising results for the development and utility of a hybrid method for use in TSUNAMI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Parallel Reconstructed Discontinuous Galerkin Method for the Compressible Flows on Aritrary Grids

A reconstruction-based discontinuous Galerkin method is presented for the solution of the compressible Navier-Stokes equations on arbitrary grids. In this method, an in-cell reconstruction is used to obtain a higher-order polynomial representation of the underlying discontinuous Galerkin polynomial solution and an inter-cell reconstruction is used to obtain a continuous polynomial solution on the union of two neighboring, interface-sharing cells. The in-cell reconstruction is designed to enhance the accuracy of the discontinuous Galerkin method by increasing the order of the underlying polynomial solution. The inter-cell reconstruction is devised to remove an interface discontinuity of the solution and its derivatives and thus to provide a simple, accurate, consistent, and robust approximation to the viscous and heat fluxes in the Navier-Stokes equations. A parallel strategy is also devised for the resulting reconstruction discontinuous Galerkin method, which is based on domain partitioning and Single Program Multiple Data (SPMD) parallel programming model. The RDG method is used to compute a variety of compressible flow problems on arbitrary meshes to demonstrate its accuracy, efficiency, robustness, and versatility. The numerical results demonstrate that this RDG method is third-order accurate at a cost slightly higher than its underlying second-order DG method, at the same time providing a better performance than the third order DG method, in terms of both computing costs and storage requirements.

97 MATHEMATICS AND COMPUTING↗