Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Sparse non-Markovian Noise Modeling of Transmon-Based Multi-Qubit Operations

The influence of noise on quantum dynamics is one of the main factors preventing current quantum processors from performing accurate quantum computations. Sufficient noise characterization and modeling can provide key insights into the effect of noise on quantum algorithms and inform the design of targeted error protection protocols. However, constructing effective noise models that are sparse in model parameters, yet predictive can be challenging. In this work, we present an approach for effective noise modeling of multi-qubit operations on transmon-based devices. Through a comprehensive characterization of seven devices offered by the IBM Quantum Platform, we show that the model can capture and predict a wide range of single- and two-qubit behaviors, including non-Markovian effects resulting from spatiotemporally correlated noise sources. The model’s predictive power is further highlighted through multi-qubit dynamical decoupling demonstrations and an implementation of the variational quantum eigensolver. As a training proxy for the hardware, we show that the model can predict expectation values within a relative error of 0.5%; this is a sevenfold improvement over default hardware noise models. Through these demonstrations, we highlight key error sources in superconducting qubits and illustrate the utility of reduced noise models for predicting hardware dynamics.

open quantum systems & decoherence↗

Evaluation of the Rapid Refresh Numerical Weather Prediction Model over Arctic Alaska

Abstract Despite a need for accurate weather forecasts for societal and economic interests in the U.S. Arctic, thorough evaluations of operational numerical weather prediction in the region have been limited. In particular, the Rapid Refresh Model (RAP), which plays a key role in short-term forecasting and decision-making, has seen very limited assessment in northern Alaska, with most evaluation efforts focused on lower latitudes. In the present study, we verify forecasts from version 4 of the RAP against radiosonde, surface meteorological, and radiative flux observations from two Arctic sites on the northern Alaskan coastline, with a focus on boundary layer thermodynamic and dynamic biases, model representation of surface inversions, and cloud characteristics. We find persistent seasonal thermodynamic biases near the surface that vary with wind direction, and may be related to the RAP’s handling of sea ice and ocean interactions. These biases seem to have diminished in the latest version of the RAP (version 5), which includes refined handling of sea ice, among other improvements. In addition, we find that despite capturing boundary layer temperature profiles well overall, the RAP struggles to consistently represent strong, shallow surface inversions. Further, while the RAP seems to forecast the presence of clouds accurately in most cases, there are errors in the simulated characteristics of these clouds, which we hypothesize may be related to the RAP’s treatment of mixed-phase clouds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Optimal Input Design and Model Selection for Communication Channels

In this paper, the optimal model (structure) selection and input design which minimize the worst case identification error for communication systems are provided. The problem is formulated using metric complexity theory in a Hilbert space setting. It is pointed out that model selection and input design can be handled independently. Kolmogorov n-width is used to characterize the representation error introduced by model selection, while Gel fand and Time n-widths are used to represent the inherent error introduced by input design. After the model is selected, an optimal input which minimizes the worst case identification error is shown to exist. In particular, it is proven that the optimal model for reducing the representation error is a Finite Impulse Response (FIR) model, and the optimal input is an impulse at the start of the observation interval. FIR models are widely popular in communication systems, such as, in Orthogonal Frequency Division Multiplexing (OFDM) systems.

fast identification↗

An Empirical Model for Energy Storage Systems

Improved models of energy storage systems are needed to enable the electric grid’s adaptation to increasing penetration of renewables. This paper develops a generic empirical model of energy storage system performance agnostic of type, chemistry, design or scale. Parameters for this model are calculated using test procedures adapted from the US DOE Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage. We then assess the accuracy of this model for predicting the performance of the TransPower GridSaver – a 1 MW rated lithium-ion battery system that underwent laboratory experimentation and analysis. The developed model predicts a range of energy storage system performance based on the uncertainty of estimated model parameters. Finally, this model can be used to better understand the integration and coordination of energy storage on the electric grid.

25 ENERGY STORAGE↗

Sampling Low-Dimensional Markovian Dynamics for Preasymptotically Recovering Reduced Models from Data with Operator Inference

This work introduces a method for learning low-dimensional models from data of high-dimensional black-box dynamical systems. The novelty is that the learned models are exactly the reduced models that are traditionally constructed with classical projection-based model reduction techniques. Thus, the proposed approach learns models that are guaranteed to have the well-studied properties of reduced models known from model reduction, without requiring full knowledge of the governing equations and without requiring the operators of the high-dimensional systems. The key ingredient is a new data sampling scheme to obtain re-projected trajectories of high-dimensional systems that correspond to Markovian dynamics in low-dimensional subspaces. The exact recovery of reduced models from these re-projected trajectories is guaranteed pre-asymptotically under certain conditions for finite amounts of data and for a large class of systems with polynomial nonlinear terms. Numerical results demonstrate that the low-dimensional models learned with the proposed approach match reduced models from traditional model reduction up to numerical errors in practice. In conclusion, the numerical results further indicate that low-dimensional models fitted to re-projected trajectories are predictive even in situations where models fitted to trajectories without re-projection are inaccurate and unstable.

97 MATHEMATICS AND COMPUTING↗

Residual Stresses and Plastic Deformation in Self-Pierce Riveting of Dissimilar Aluminum-to-Magnesium Alloys

In this study, the complex relationship between deformation history and residual stresses in a magnesium-to-aluminum self-pierce riveted (SPR) joint is elucidated using numerical and experimental approaches. Non-linear finite element (FE) simulations incorporating strain rate and temperature effects were performed to model the deformation in the SPR process. In order to accurately capture the deformation, a stress triaxiality-based damage material model was employed to capture the sheet piercing from the rivet. Strong visual comparison between the physical cross-section of the SPR joint and the simulation was achieved. To aid in understanding of the role of deformation in the riveting process and to validate the modeling approach, several experimental measurements were conducted. To quantify the plastic deformation from the piercing of the rivet, micro hardness mapping was performed on a cross-section of the SPR joint. The FE model showed very strong correlation to the experimental hardness mapping results suggesting the nonlinear model captured the plastic deformation with high accuracy. To measure the elastic residual stresses in the SPR joint, neutron and x-ray diffraction mapping techniques were conducted and in general, the FE model correlated well to the trends and magnitudes of the elastic stresses. While some error occurred in between the model and the neutron and x-ray diffraction results, the numerical approach developed in this study shows potential as a tool for understanding SPR behavior as well as optimizing the process parameters.

36 MATERIALS SCIENCE↗

Uncertainty quantification and error analysis

UQ studies all sources of error and uncertainty, including: systematic and stochastic measurement error; ignorance; limitations of theoretical models; limitations of numerical representations of those models; limitations on the accuracy and reliability of computations, approximations, and algorithms; and human error. A more precise definition for UQ is suggested below.

99 GENERAL AND MISCELLANEOUS↗

Astrometric Calibration and Performance of the Dark Energy Camera

We characterize the ability of the Dark Energy Camera (DECam) to perform relative astrometry across its 500 Mpix, 3 $deg^2$ science field of view, and across 4 years of operation. This is done using internal comparisons of $~ 4 x 10^7$ measurements of high-S/N stellar images obtained in repeat visits to fields of moderate stellar density, with the telescope dithered to move the sources around the array. An empirical astrometric model includes terms for: optical distortions; stray electric fields in the CCD detectors; chromatic terms in the instrumental and atmospheric optics; shifts in CCD relative positions of up to $\approx 10 \mu m$ when the DECam temperature cycles; and low-order distortions to each exposure from changes in atmospheric refraction and telescope alignment. Errors in this astrometric model are dominated by stochastic variations with typical amplitudes of 10-30 mas (in a 30 s exposure) and $5^{\prime}-10^{\prime}$ arcmin coherence length, plausibly attributed to Kolmogorov-spectrum atmospheric turbulence. The size of these atmospheric distortions is not closely related to the seeing. Given an astrometric reference catalog at density $\approx 0.7$ $arcmin^{-2}$, e.g. from Gaia, the typical atmospheric distortions can be interpolated to $\approx$ 7 mas RMS accuracy (for 30 s exposures) with $1^{\prime}$ arcmin coherence length for residual errors. Remaining detectable error contributors are 2-4 mas RMS from unmodelled stray electric fields in the devices, and another 2-4 mas RMS from focal plane shifts between camera thermal cycles. Thus the astrometric solution for a single DECam exposure is accurate to 3-6 mas ( $\approx$ 0.02 pixels, or $\approx$ 300 nm) on the focal plane, plus the stochastic atmospheric distortion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-69: Correction Model of NIPAM Gel and Presage for Electron and Proton PDD Measurement

Purpose: The current standard equipment for proton PDD measurement is multilayer-parallel-ion-chamber. Disadvantage of multilayer-parallel-ion-chamber is expensive and complexity manipulation. NIPAM-gel and Presage are options for PDD measurement. Due to different stopping power, the result of NIPAM-gel and Presage need to be corrected. This study aims to create a correction model for NIPAM-gel and Presage PDD measurement. Methods: Standard water based PDD profiles of electron 6MeV, 12MeV, and proton 90MeV were acquired. Electron PDD profile after 1cm thickness of NIPAM-gel added on the top of water was measured. Electron PDD profile with extra 1cm thickness of solid water, PTW RW3, was measured. The distance shift among standard PDD, NIPAM-gel PDD, and solid water PDD at R50% was compared and water equivalent thickness correction factor (WET) was calculated. Similar process was repeated. WETs for electron with Presage, proton with NIPAM-gel, and proton with Presage were calculated. PDD profiles of electron and proton with NIPAM-gel and Presage columns were corrected with each WET. The corrected profiles were compared with standard profiles. Results: WET for electron 12MeV with NIPAM-gel was 1.135, and 1.034 for electron 12Mev with Presage. After correction, PDD profile matched to the standard profile at the fall-off range well. The difference at R50% was 0.26mm shallower and 0.39mm deeper. The same WET was used to correct electron 6MeV profile. Energy independence of electron WET was observed. The difference at R50% was 0.17mm deeper for NIPAM-gel and 0.54mm deeper for Presage. WET for proton 90MeV with NIPAM-gel was 1.056. The difference at R50% was 0.37 deeper. Quenching effect at Bragg peak was revealed. The underestimated dose percentage at Bragg peak was 27%. Conclusion: This correction model can be used to modify PDD profile with depth error within 1mm. With this correction model, NIPAM-gel and Presage can be practical at PDD profile measurement.

60 APPLIED LIFE SCIENCES↗

PERIOD ERROR ESTIMATION FOR THE KEPLER ECLIPSING BINARY CATALOG

The Kepler Eclipsing Binary Catalog (KEBC) describes 2165 eclipsing binaries identified in the 115 deg{sup 2} Kepler Field based on observations from Kepler quarters Q0, Q1, and Q2. The periods in the KEBC are given in units of days out to six decimal places but no period errors are provided. We present the PEC (Period Error Calculator) algorithm, which can be used to estimate the period errors of strictly periodic variables observed by the Kepler Mission. The PEC algorithm is based on propagation of error theory and assumes that observation of every light curve peak/minimum in a long time-series observation can be unambiguously identified. The PEC algorithm can be efficiently programmed using just a few lines of C computer language code. The PEC algorithm was used to develop a simple model that provides period error estimates for eclipsing binaries in the KEBC with periods less than 62.5 days: log {sigma}{sub P} Almost-Equal-To - 5.8908 + 1.4425(1 + log P), where P is the period of an eclipsing binary in the KEBC in units of days. KEBC systems with periods {>=}62.5 days have KEBC period errors of {approx}0.0144 days. Periods and period errors of seven eclipsing binary systems in the KEBC were measured using the NASA Exoplanet Archive Periodogram Service and compared to period errors estimated using the PEC algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

Data & model conditioning for multivariate systematic uncertainty in model calibration, validation, and extrapolation.

This paper discusses implications and appropriate treatment of systematic uncertainty in experiments and modeling. Systematic uncertainty exists when experimental conditions, and/or measurement bias errors, and/or bias contributed by post-processing the data, are constant over the set of experiments but the particular values of the conditions and/or biases are unknown to within some specified uncertainty. Systematic uncertainties in experiments do not automatically show up in the output data, unlike random uncertainty which is revealed when multiple experiments are performed. Therefore, the output data must be properly 'conditioned' to reflect important sources of systematic uncertainty in the experiments. In industrial scale experiments the systematic uncertainty in experimental conditions (especially boundary conditions) is often large enough that the inference error on how the experimental system maps inputs to outputs is often quite substantial. Any such inference error and uncertainty thereof also has implications in model validation and calibration/conditioning; ignoring systematic uncertainty in experiments can lead to 'Type X' error in these procedures. Apart from any considerations of modeling and simulation, reporting of uncertainty associated with experimental results should include the effects of any significant systematic uncertainties in the experiments. This paper describes and illustrates the treatment of multivariate systematic uncertainties of interval and/or probabilistic natures, and combined cases. The paper also outlines a practical and versatile 'real-space' framework and methodology within which experimental and modeling uncertainties (correlated and uncorrelated, systematic and random, aleatory and epistemic) are treated to mitigate risk in model validation, calibration/conditioning, hierarchical modeling, and extrapolative prediction.

97 MATHEMATICS AND COMPUTING↗

MO-FG-303-03: Demonstration of Universal Knowledge-Based 3D Dose Prediction

Purpose: To demonstrate a knowledge-based 3D dose prediction methodology that can accurately predict achievable radiotherapy distributions. Methods: Using previously treated plans as input, an artificial neural network (ANN) was trained to predict 3D dose distributions based on 14 patient-specific anatomical parameters including the distance (r) to planning target volume (PTV) boundary, organ-at-risk (OAR) boundary distances, and angular position ( θ,φ). 23 prostate and 49 stereotactic radiosurgery (SRS) cases with ≥1 nearby OARs were studied. All were planned with volumetric-modulated arc therapy (VMAT) to prescription doses of 81Gy for prostate and 12–30Gy for SRS. Site-specific ANNs were trained using all prostate 23 plans and using a 24 randomly-selected subset for the SRS model. The remaining 25 SRS plans were used to validate the model. To quantify predictive accuracy, the dose difference between the clinical plan and prediction were calculated on a voxel-by-voxel basis δD(r,θ,φ)=Dclin(r,θ,φ)-Dpred(r, θ,φ). Grouping voxels by boundary distance, the mean <δ Dr>=(1/N)Σ -θ,φ D(r,θ,φ) and inter-quartile range (IQR) quantified the accuracy of this method for deriving DVH estimations. The standard deviation (σ) of δ D quantified the 3D dose prediction error on a voxel-by-voxel basis. Results: The ANNs were highly accurate in predictive ability for both prostate and SRS plans. For prostate, <δDr> ranged from −0.8% to +0.6% (max IQR=3.8%) over r=0–32mm, while 3D dose prediction accuracy averaged from σ=5–8% across the same range. For SRS, from r=0–34mm the training set <δDr> ranged from −3.7% to +1.5% (max IQR=4.4%) while the validation set <δDr> ranged from −2.2% to +5.8% (max IQR=5.3%). 3D dose prediction accuracy averaged σ=2.5% for the training set and σ=4.0% over the same interval. Conclusion: The study demonstrates this technique’s ability to predict achievable 3D dose distributions for VMAT SRS and prostate. Future investigations will attempt to separate and quantify modeling error and plan quality variations in the statistical noise. Research funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 33: The Influence of a Modeled Treatment Couch on Dose Distributions During IMRT and RapidArc Treatment Delivery

Treatment couches have been known to perturb dose delivery in patients. This effect is most pronounced in techniques such as IMRT and RapidArc. Although modern treatment planning systems (TPS) include data for a “default” treatment couch, actual couches are not manufactured identically. Thus, variations in their Hounsfield Unit (HU) values may exist. This study demonstrates a practical and simple method of acquiring reliable HU data for any treatment couch. We also investigate the effects of both the default and modeled treatment couches on absorbed dose. Experimental verifications show that by neglecting to incorporate the treatment couch in the TPS, dose differences of up to 9.5% and 7.3% were present for 4 MV and 10 MV photon beams, respectively. Furthermore, a clinical study based on a cohort of 20 RapidArc and IMRT (brain, pelvis and abdominal) cases is performed. 2D dose distributions show that without the couch in the planning phase, differences ≤ 4.6% and 5.9% for RapidArc and IMRT cases are present for the same cases that the default couch was added to. Additionally, in comparison to the default couch, employing the modeled couch in the calculation process influences dose distributions by ≤ 2.7% and 8% for RapidArc and IMRT cases, respectively. This result was found to be site specific; where an accurate couch proves to be preferable for IMRT brain plans. As such, adding the couch during dose calculation decreases dose calculation errors, and a precisely modeled treatment couch offers higher dose delivery accuracy for brain treatment using IMRT.

60 APPLIED LIFE SCIENCES↗

IMAGING AND MODELING RAPIDLY ROTATING STARS: {alpha} CEPHEI AND {alpha} OPHIUCHI

We present submilliarcsecond resolution imaging and modeling of two nearby rapid rotators {alpha} Cephei and {alpha} Ophiuchi, obtained with the CHARA array-the largest optical/IR interferometer in the world. Incorporating a gravity-darkening model, we are able to determine the inclination, the polar and equatorial radius and temperature, as well as the fractional rotation speed of the two stars with unprecedented precision. The polar and equatorial regions of the two stars have {approx}2000 K temperature gradient, causing their apparent temperatures and luminosities to be dependent on their viewing angles. Our modeling allow us to determine the true effective temperatures and luminosities of {alpha} Cep and {alpha} Oph, permitting us to investigate their true locations on the H-R diagram. These properties in turn give us estimates of the masses and ages of the two stars within a few percent of error using stellar evolution models. Also, based on our gravity-darkening modeling, we propose a new method to estimate the masses of single stars in a more direct way through Vsin i measurements and precise geometrical constraint. Lastly, we investigate the degeneracy between the inclination and the gravity-darkening coefficient, which especially affects the modeling of {alpha} Oph. Although incorporating Vsin i has lifted the degeneracy to some extent, higher-resolution observations are still needed to further constrain the parameters independently.

99 GENERAL AND MISCELLANEOUS↗

The Atacama Cosmology Telescope: DR6 constraints on extended cosmological models

We use new cosmic microwave background (CMB) primary temperature and polarization anisotropy measurements from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) to test foundational assumptions of the standard cosmological model, ΛCDM, and set constraints on extensions to it. We derive constraints from the ACT DR6 power spectra alone, as well as in combination with legacy data from the Planck mission. To break geometric degeneracies, we include ACT and Planck CMB lensing data and baryon acoustic oscillation data from DESI Year-1. To test the dependence of our results on non-ACT data, we also explore combinations replacing Planck with WMAP and DESI with BOSS, and further add supernovae measurements from Pantheon+ for models that affect the late-time expansion history. We verify the near-scale-invariance (running of the spectral index dn s /d ln k = 0.0062 ± 0.0052) and adiabaticity of the primordial perturbations. Neutrino properties are consistent with Standard Model predictions: we find no evidence for new light, relativistic species that are free-streaming (N eff = 2.86 ± 0.13, which combined with astrophysical measurements of primordial helium and deuterium abundances becomes N eff = 2.89 ± 0.11), for non-zero neutrino masses (∑m ν < 0.089 eV at 95% CL), or for neutrino self-interactions. We also find no evidence for self-interacting dark radiation (N idr < 0.134), or for early-universe variation of fundamental constants, including the fine-structure constant (α EM /α EM,0 = 1.0043 ± 0.0017) and the electron mass (m e /m e,0 = 1.0063 ± 0.0056). Our data are consistent with standard big bang nucleosynthesis (we find Y p = 0.2312 ± 0.0092), the COBE/FIRAS-inferred CMB temperature (we find T CMB = 2.698 ± 0.016 K), a dark matter component that is collisionless and with only a small fraction allowed as axion-like particles, a cosmological constant (w = -0.986 ± 0.025), and the late-time growth rate predicted by general relativity (γ = 0.663 ± 0.052). We find no statistically significant preference for a departure from the baseline ΛCDM model. In fits to models invoking early dark energy, primordial magnetic fields, or an arbitrary modified recombination history, we find H 0 = 69.9 +0.8 -1.5 , 69.1 ± 0.5, or 69.6 ± 1.0 km/s/Mpc, respectively; using BOSS instead of DESI BAO data reduces the central values of these constraints by 1–1.5 km/s/Mpc while only slightly increasing the error bars. In general, models introduced to increase the Hubble constant or to decrease the amplitude of density fluctuations inferred from the primary CMB are not favored over ΛCDM by our data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Efficient Electrochemical Tanks-in-Series Model for Lithium Sulfur Batteries

This article applies and efficiently implements the Tanks-in-Series methodology ( J. Electrochem. Soc. , 167 , 013534 (2020)) to generate a computationally efficient electrochemical model for Lithium-Sulfur batteries. The original Tank model approach for Lithium-ion batteries is modified to account for porosity changes with time. In addition, an exponential scaling method is introduced that enables efficient simulation of the model equations to address the wide range of time constants present for different reactions in the Lithium-Sulfur system. The Tank Model achieves acceptable voltage error even for transport-limited discharged conditions. Predictions of internal electrochemical variables are examined, and electrochemical implications of the approximations discussed. This suggests significant potential for real-time applications such as optimal charging, cell-balancing, and estimation, and represents a step forward in efforts to incorporate detailed electrochemical models in advanced Battery Management Systems for Lithium-Sulfur batteries.

Parke, Caitlin D. (ORCID:0000000177324044)↗

Radiatively important parameters best estimate (RIPBE) value-added product (VAP)

Currently, to calculate radiative heating rate profiles for the Broadband Heating Rate Profile (BBHRP) product, radiatively important parameters (water vapor, ozone, surface albedo, aerosol properties, and cloud properties) from multiple VAPs and datastreams are combined into input text files that are then used to run the RRTM radiative transfer codes. These input parameters have different temporal and spatial scales and are difficult to extract from the text files to be used for other purposes such as running other radiative transfer codes, analyzing results, or error tracking. The purpose of the Radiatively Important Parameters Best Estimate (RIPBE) VAP is to improve this process by creating a clearly identified set of inputs for BBHRP (and other radiation codes) on a uniform vertical and temporal grid. This process will decouple the input/output portion of the BBHRP from the core physics (the RRTM radiative transfer model) and will add error tracking and version information to the input data set. Critical parameters (which must exist for the radiation code to be run) will be designated; for other parameters, climatological or fixed values will be used when the preferred values are missing. This should increase the number of cases for which radiative transfer calculations can be run. In all cases, flags will clearly identify the source for each parameter. RIPBE will serve multiple functions: (1) it will provide a clearly identifiable set of inputs for BBHRP, (2) it will facilitate the use of BBHRP as a retrieval and radiation code development testbed by providing a vehicle for easily extracting and swapping input parameters needed to conduct radiative transfer calculations, and (3) it will be a complement to the Climate Modeling Best Estimate (CMBE) VAP and will provide a significantly expanded set of parameters for model evaluation in a showcase data set form. At the ASR meeting, we will present examples and evaluation of the initial RIPBE dataset at SGP.

54 ENVIRONMENTAL SCIENCES↗