Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

W-Band InP Wideband MMIC LNA with 30K Noise Temperature

This paper describe a millimeter wave low noise amplifier with extraordinary low noise, low consumption, and wide frequency range. These results are achieved utilizing state-of-the-art InP HEMT transistors coupled with CPW circuit design. The paper describes the transistor models, modeled and measured on-wafer and in-module results at both 300K am 24K operating temperatures for many samples of the device.

Weinreb, S.↗

Ultra Stable Microwave Radiometers for Future Sea Surface Salinity Missions

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius will measure global sea surface salinity with 100-km spatial resolution every 8 days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than 0.1 K over 8 days. This three-year research program on ultra stable radiometers has addressed the radiometer requirements and configuration necessary to achieve this objective for Aquarius and future ocean salinity missions. The system configuration and component performance have been evaluated with radiometer testbeds at both JPL and GSFC. The research has addressed several areas including component characterization as a function of temperature, a procedure for the measurement and correction for radiometer system non-linearity, noise diode calibration versus temperature, low noise amplifier performance over voltage, and temperature control requirements to achieve the required stability. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This report also presents the results of the radiometer test program, a detailed radiometer noise model, and details of the operational switching sequence optimization that can be used to achieve the low noise and stability requirements. Many of the results of this research have been incorporated into the Aquarius radiometer design and will allow this instrument to achieve its goals.

sea surface salinity↗

500 MW X-Band RF System of a 0.25 GeV Electron LINAC for Advanced Compton Scattering Source Application

A Mono-Energetic Gamma-Ray (MEGa-Ray) Compton scattering light source is being developed at LLNL in collaboration with the SLAC National Accelerator Laboratory. The electron beam for the Compton scattering interaction will be generated by a X-band RF gun and a X-band LINAC at the frequency of 11.424 GHz. High power RF in excess of 500 MW is needed to accelerate the electrons to energy of 250 MeV or greater for the interaction. Two high power klystron amplifiers, each capable of generating 50 MW, 1.5 msec pulses, will be the main high power RF sources for the system. These klystrons will be powered by state of the art solid-state high voltage modulators. A RF pulse compressor, similar to the SLED II pulse compressor, will compress the klystron output pulse with a power gain factor of five. For compactness consideration, we are looking at a folded waveguide setup. This will give us 500 MW at output of the compressor. The compressed pulse will then be distributed to the RF gun and to six traveling wave accelerator sections. Phase and amplitude control are located at the RF gun input and additional control points along the LINAC to allow for parameter control during operation. This high power RF system is being designed and constructed. In this paper, we will present the design, layout, and status of this RF system.

43 PARTICLE ACCELERATORS↗

On forced RF generation of CW magnetrons for SRF accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost of RF power per Watt than used traditionally klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain to start up reliably with self-excitation even if the tube is powered by a DC power supply. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a signal PLock ≤ -20 dB or less then of the magnetron power PMag. Then the magnetron generates the injection locked oscillations and generates noise. This may preclude use of standard CW magnetrons in some SRF accelerators. We developed briefly described below a mode for forced coherent RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

Kazakevich, G.↗

Status of the microwave power transmission components for the solar power satellite

During the 1970-1980 time period a substantial advance has been made in developing all portions of a microwave power transmission system for the solar power satellite (SPS). The most recent advances pertain to the transmitting portion of the system in the satellite and are based upon experimental observations of the use of the magnetron combined with a passive directional device to convert it into a highly efficient directional amplifier with excellent low-noise properties and potentially very long life. The ability of its microwave output to track a phase reference makes it possible to combine it with many other radiating units to provide a highly coherent microwave beam. The ability of its output to track an amplitude reference while operating from a dc power source with varying voltage makes it possible to eliminate most of the power conditioning equipment that would otherwise be necessary.

Brown, W. C.↗

Application of MMIC modules in future multiple beam satellite antenna systems

Multiple beam antenna systems for advanced communication satellites operating in the 30/20 GHz frequency bands (30 GHz uplink, 20 GHz downlink) were developed. Up to twenty 0.3 deg HPBW fixed spot beams and six 0.3 deg HPBW scanning spot beams will be required. Array-fed dual reflector antenna systems in which monolithic microwave integrated circuit (MMIC) phase shift and amplifier modules are used with each radiating element of the feed array for beam pointing and power gain were developed. The feasibility of distributed power amplification and beam pointing with MMIC modules in the elements of an array and to develop a data base for future development were demonstrated. The technical discussion centers around the potential advantages of ""monolithic'' antennas for specific applications as compared to systems using high powered TWT's. These include: reduced losses in the beam forming network; advantage of space combining and graceful degradation; dynamic control of beam pointing and illumination contour; and possibilities for cost and weight reduction.

Smetana, J.↗

An active radar calibration target

An active radar calibrator (ARC), consisting of a receive antenna and a transmit antenna with an RF amplifier in between, is proposed as a tool for conducting high-precision calibration measurements of radar systems. The ARC can be designed to have a large radar cross-section with a broad pattern. Its major advantages over passive reflectors are its small physical size and its suitability for calibrating radars operating in a cross-polarized antenna configuration.

Brunfeldt, D. R.↗

Force analysis of magnetic bearings with power-saving controls

Most magnetic bearing control schemes use a bias current with a superimposed control current to linearize the relationship between the control current and the force it delivers. For most operating conditions, the existence of the bias current requires more power than alternative methods that do not use conventional bias. Two such methods are examined which diminish or eliminate bias current. In the typical bias control scheme it is found that for a harmonic control force command into a voltage limited transconductance amplifier, the desired force output is obtained only up to certain combinations of force amplitude and frequency. Above these values, the force amplitude is reduced and a phase lag occurs. The power saving alternative control schemes typically exhibit such deficiencies at even lower command frequencies and amplitudes. To assess the severity of these effects, a time history analysis of the force output is performed for the bias method and the alternative methods. Results of the analysis show that the alternative approaches may be viable. The various control methods examined were mathematically modeled using nondimensionalized variables to facilitate comparison of the various methods.

Johnson, Dexter↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗

Effect of Space Vehicle Structure Vibration on Control Moment Gyroscope Dynamics

Control Moment Gyroscopes (CMGs) are used for non-propulsive attitude control of satellites and space stations, including the International Space Station (ISS). CMGs could be essential for future long duration space missions due to the fact that they help to save propellant. CMGs were successfully tested on the ground for many years, and have been successfully used on satellites. However, operations have shown that the CMG service life on the ISS is significantly shorter than predicted. Since the dynamic environment of the ISS differs greatly from the nominal environment of satellites, it was important to analyze how operations specific to the station (dockings and undockings, huge solar array motion, crew exercising, robotic operations, etc) can affect the CMG performance. This task became even more important since the first CMG failure onboard the ISS. The CMG failure resulted in the limitation of the attitude control capabilities, more propellant consumption, and additional operational issues. Therefore, the goal of this work was to find out how the vibrations of a space vehicle structure, caused by a variety of onboard operations, can affect the CMG dynamics and performance. The equations of CMG motion were derived and analyzed for the case when the gyro foundation can vibrate in any direction. The analysis was performed for unbalanced CMG gimbals to match the CMG configuration on ISS. The analysis showed that vehicle structure vibrations can amplify and significantly change the CMG motion if the gyro gimbals are unbalanced in flight. The resonance frequencies were found. It was shown that the resonance effect depends on the magnitude of gimbal imbalance, on the direction of a structure vibration, and on gimbal bearing friction. Computer modeling results of CMG dynamics affected by the external vibration are presented. The results can explain some of the CMG vibration telemetry observed on ISS. This work shows that balancing the CMG gimbals decreases the effect of vehicle structure vibration on CMGs. Additionally, the effect of external vibrations may also be decreased by increasing the gimbal bearing friction. With the suggested modifications there may be no need to lower the gimbal rates below the nominal design requirements as it is currently done on ISS. The conclusions of this work

Dobrinskaya, Tatiana↗

Progress of 2.05 uM Fiber Laser Development for A Martian Co2 Dial

We have proposed a new concept for differential absorption lidar (DIAL) operating in the 2050 nm CO 2 absorption band for atmospheric CO 2 and pressure observations on Mars. This concept has earned us funding from NASA's PICASSO Program to advance 2050 nm fiber laser technology for future space applications. The laser design is an all-fiber master oscillator and power amplifier (MOPA) system. The master oscillator with pulse shaping and several stages of fiber preamplifiers has been built. Preliminary tests show the output pulse energy can reach 1 mJ, meeting our baseline goal. However, the current power amplifier design has an issue with undesired parasitic lasing at a different frequency, which exhausts pump energy and limits the laser energy. We have modified the power amplifier design to suppress parasitic lasing, and higher laser power energy is expected. To achieve high measurement accuracy, the laser frequency must be stabilized. A fraction of the master oscillator is split to lock the laser frequency to the center of the selected absorption line. The laser can then be shifted to a frequency far from the absorption line center, where extinction due to CO 2 and other trace gases is minimal, serving as the offline reference. The online wavelength is optimized at 2050.44156 nm, ensuring a CO 2 absorption optical depth (AOD) of approximately 1.1 at 3 km, which maximizes the signal-to-noise ratio (SNR) for measurements in the lower Martian atmosphere. At the conference, we will provide more details about this project and report on the progress of instrument development.

DIAL↗

High count rate thermal neutron detectors and electronics

Improved, high count rate thermal neutron counters and electronics enabling new, higher measurement capabilities are disclosed. Next generation 3He and 10B tubes may include an electronics package capable of operating at higher count rates and in higher gamma fields and providing more efficient use of 3He gas. Conventional detector systems may also be upgraded, providing a possible solution to measure spent nuclear fuel with high neutron efficiency previously not possible in 235U fission counter systems. Switching the number of tubes per amplifier allows use of the measured nuclear material for a calibration standard for dead time correction, increasing accuracy of neutron measurements systems. An optimized detector geometry and advanced electronics with double pulse filtering and a dual channel readout may be provided. A bipolar shaper may improve dead time, provide efficient detector use, reduce double pulsing, facilitate high count rate measurements, and allow remote threshold setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation of high-harmonic fast-wave propagation in the scrape-off layer of NSTX-U as a geometrically bounded-waveguide mode

This paper revisits the onset of high-harmonic fast-wave (HHFW) propagation in the scrape-off layer (SOL) plasma of the NSTX/NSTX-U spherical tokamak, motivated by past HHFW heating and current drive experiments and modelling. Previously, the fast-wave propagation in the SOL was correlated with the opening (suppression) of the fast-wave right-hand cutoff layer in front of the antenna. In this work, the SOL propagation is interpreted as a geometric waveguide mode guided by the SOL geometry, whose radial width can be comparable to the wave’s perpendicular wavelength in the HHFW regime. A two-dimensional circular model is first employed using full-wave solvers to characterise the poloidal eigenmode structures and to clarify their relationship to annulus resonance. By progressively adding a tokamak-like magnetic-field configuration, starting from a uniform axial field, the effects of magnetic-field gradients and pitch on the SOL waveguide mode are characterised. The poloidal mode numbers supported by the SOL plasma agree well with analytic estimates, indicating that an anisotropic plasma in a bounded geometry selectively supports and amplifies the resonant poloidal mode number. Additionally, two-dimensional axisymmetric NSTX-U simulations demonstrate that the SOL eigenmode features identified in the circular model persist in the experimentally relevant configurations. A control approach based on lengthening the wave perpendicular wavelength relative to the SOL width, including a higher magnetic (B)-field operation, is discussed. The analysis here shows the key role of a bounded geometry in interpreting HHFW eigenmode coupling and propagation in the NSTX-U SOL plasma.

plasma heating↗

Long-term calibration and validation of stability of the Auger Engineering Radio Array using the diffuse Galactic radio emission

The Auger Engineering Radio Array (AERA) measures radio emission from high-energy extensive air showers. Consisting of 153 autonomous radio-detector stations spread over 17 km^2, it detects radio waves in the frequency range of 30 to 80 MHz. Accurate characterization of the detector response is crucial for proper interpretation of the collected data. Previously, this was achieved through laboratory measurements of the analog chain and simulations and measurements of the antenna's directional response. In this paper, we perform an absolute calibration using the continuously monitored sidereal modulation of the diffuse Galactic radio emission. Calibration is done by comparing the average frequency spectra recorded by the stations with predictions from seven different models of the full radio sky, accounting for the system response, which includes the antenna, filters, and amplifiers. The analysis of the calibration constants over a period of seven years shows no relevant and no significant ageing effect in the AERA antennas. This result confirms the long-term stability of the detector stations and demonstrates the possibility for a radio detector to effectively monitor ageing effects of other detectors operating over extended periods.

Antennas↗

Broadband coplanar-waveguide-based impedance-transformed Josephson parametric amplifier

Quantum-limited Josephson parametric amplifiers play a pivotal role in advancing the field of circuit quantum electrodynamics by enabling the fast and high-fidelity measurement of weak microwave signals. Therefore, it is necessary to develop robust parametric amplifiers with low noise, broad bandwidth, and reduced design complexity for microwave detection. However, current broadband parametric amplifiers either have degraded noise performance or rely on complex designs. Here, we present a device based on the broadband impedance-transformed Josephson parametric amplifier that integrates a hornlike coplanar waveguide transmission line, which significantly decreases the design and fabrication complexity while keeping comparable performance. The device shows an instantaneous bandwidth of 700 (200) MHz for 15 (20) dB gain with an average input saturation power of − 110 dBm and near quantum-limited added noise. The operating frequency can be tuned over 1.4 GHz using an external flux bias. We further demonstrate the negligible backaction from our device on a transmon qubit. The amplification performance and simplicity of our device promise its wide adaptation in quantum metrology, quantum communication, and quantum information processing. Published by the American Physical Society 2024

Qing, Bingcheng (ORCID:0000000345227017)↗

Integrator Circuitry for Single Channel Radiation Detector

Input circuitry is provided for a high voltage operated radiation detector to receive pulses from the detector having a rise time in the range of from about one nanosecond to about ten nanoseconds. An integrator circuit, which utilizes current feedback, receives the incoming charge from the radiation detector and creates voltage by integrating across a small capacitor. The integrator utilizes an amplifier which closely follows the voltage across the capacitor to produce an integrator output pulse with a peak value which may be used to determine the energy which produced the pulse. The pulse width of the output is stretched to approximately 50 to 300 nanoseconds for use by subsequent circuits which may then use amplifiers with lower slew rates.

Holland, Samuel D.↗

Measurements by a Vector Network Analyzer at 325 to 508 GHz

Recent experiments were performed in which return loss and insertion loss of waveguide test assemblies in the frequency range from 325 to 508 GHz were measured by use of a swept-frequency two-port vector network analyzer (VNA) test set. The experiments were part of a continuing effort to develop means of characterizing passive and active electronic components and systems operating at ever increasing frequencies. The waveguide test assemblies comprised WR-2.2 end sections collinear with WR-3.3 middle sections. The test set, assembled from commercially available components, included a 50-GHz VNA scattering- parameter test set and external signal synthesizers, augmented with recently developed frequency extenders, and further augmented with attenuators and amplifiers as needed to adjust radiofrequency and intermediate-frequency power levels between the aforementioned components. The tests included line-reflect-line calibration procedures, using WR-2.2 waveguide shims as the "line" standards and waveguide flange short circuits as the "reflect" standards. Calibrated dynamic ranges somewhat greater than about 20 dB for return loss and 35 dB for insertion loss were achieved. The measurement data of the test assemblies were found to substantially agree with results of computational simulations.

Fung, King Man↗

Multi-Band and Multi-Function Reconfigurable Gallium Nitride Based Fully Solid-State Microwave Power Module for Cognitive Radio/Radar Platforms

This paper presents as a proof-of-concept (POC) the design, integration, and performance of a novel reconfigurable S-/X-band Gallium Nitride (GaN) based fully solid-state microwave power module (SSMPM) for the role as the transmit module in a cognitive radio (CR). The SSMPM synergistically integrates multiple amplifiers through diplexing and high power switches to enable a single SSMPM capable of functioning as both S-/X-band amplifiers for telemetry, tracking, and command (TT&C), telecommunications, and science data downlink or as X-band radar for proximity sensing onboard a planetary exploration spacecraft. Integration of an electric field shaping field plate (FP) onto the GaN high electron mobility transistors (HEMTs) in this SSMPM provides increased performance and reliability for operation in the harsh conditions of space. This SSMPM is capable of delivering saturated power (Psat) of 39 dBm (8 W continuous wave (CW)) at S-band, P(sub sat) of 43 dBm (20 W CW) at X-band, and P(sub sat) of >50 dBm (>100 W Pulsed) at X-band.

Simons, Rainee N.↗